lastID = -295578
Skip to main content Skip to top navigation Skip to site search
Top of page
  • My citations options
    Web Back (from Web)
    Chicago Back (from Chicago)
    MLA Back (from MLA)
Close action menu

You need to login to use this feature.

Please wait a moment…
Please wait while we update your results...
Please wait a moment...
Loading icon
Description: Access Water
Context Menu
Description: Book cover
Pilot Study for the Applicability of Biofilter Odor Control Technology for use at New York City Water Pollution Control Plants
  • Browse
  • Compilations
    • Compilations list
  • Subscriptions
Tools

Related contents

Loading related content

Workflow

No linked records yet

X
  • Current: 2020-03-27 00:03:29 Adam Phillips
  • 2020-02-01 02:58:23 Administrator
  • 2020-02-01 02:58:22 Administrator
Description: Access Water
  • Browse
  • Compilations
  • Subscriptions
Log in
0
Accessibility Options

Base text size -

This is a sample piece of body text
Larger
Smaller
  • Shopping basket (0)
  • Accessibility options
  • Return to previous
Description: Book cover
Pilot Study for the Applicability of Biofilter Odor Control Technology for use at New York City Water Pollution Control Plants

Pilot Study for the Applicability of Biofilter Odor Control Technology for use at New York City Water Pollution Control Plants

Pilot Study for the Applicability of Biofilter Odor Control Technology for use at New York City Water Pollution Control Plants

  • New
  • View
  • Details
  • Reader
  • Default
  • Share
  • Email
  • Facebook
  • Twitter
  • LinkedIn
  • New
  • View
  • Default view
  • Reader view
  • Data view
  • Details

This page cannot be printed from here

Please use the dedicated print option from the 'view' drop down menu located in the blue ribbon in the top, right section of the publication.

screenshot of print menu option

Description: Book cover
Pilot Study for the Applicability of Biofilter Odor Control Technology for use at New York City Water Pollution Control Plants
Abstract
Throughout the New York City Department of Environmental Protection (NYCDEP) wastewater treatment system, chemical scrubbers and/or carbon adsorption units have typically been used to treat odorous air emissions. Although these are adequate methods to remove Hydrogen Sulfide (H2S) and Volatile Organic Compound (VOC) constituents that compose malodorous emissions, the need for simpler, more economical, and environmentally-friendly technologies has come to light.Preceding major upgrades of the Jamaica Water Pollution Control Plant's odor control system scheduled to be implemented by 2012, NYCDEP has authorized this Pilot Program utilizing Biofilter technology at the Jamaica plant. The Jamaica Biofilter Pilot Program allows the opportunity to demonstrate the applicability of Biofilters within the rigid NYCDEP wastewater treatment system, proving their efficiency and cost effectiveness. Future odor control upgrades at Jamaica must provide sufficient treatment to maintain adherence to the New York State Department of Environmental Conservation's regulatory requirement of less than 10 ppb of H2S at the fenceline of the plant and also NYCDEP guidance that requires less than 1 ppb of H2S at sensitive receptors.Previous studies of H2S emissions at wastewater treatment plants has shown that the major source of H2S emissions in wastewater treatment is the effluent weir section of the of the primary clarifier tanks. This is due to the large concentration of reduced sulfur compounds produced within the sludge beds of the clarifier tanks that is then released as H2S when turbulence exposes the sulfur compounds to air allowing the gas to then escape. The outfall of the effluent weirs is the primary location of this release. For this Pilot Program, the effluent weir section of one primary settling tank at the Jamaica WPCP has been isolated, drawing the odorous air into the Biofilter unit. H2S levels under these tank covers were monitored in the fall of 2006 and have found an average concentration of 0.5 parts per million (ppm) and a peak concentration of 4.2 ppm H2S.Based on the amount of airflow expected from this weir section and the target removal efficiency, the Biofilter unit was sized at 600 cubic feet of organic media. This size unit provides approximately 60 seconds of Empty Bed Contact Time (EBCT). Based on previous studies, this retention time should allow for 99.5% removal efficiency of H2S plus substantial removal of VOC's as well although VOCs were not targeted for performance criteria.The Pilot was in operation for one year. As part of the sampling protocol, two rounds of testing were conducted: one in summer, one in winter. This sampling was conducted to verify that the biofilter has the ability to meet strict removal criteria for both hydrogen sulfide (H2S) and dilutions-to-threshold (D/t) of Total Odor. The criteria are as follows:Hydrogen sulfide: minimum 99.5% removal or 0.025 ppm H2S maximum outlet concentration.Total odor: D/t ≤ 350, or 350 ≤ D/t ≤ 500 with a neutral or positive hedonic tone.Sampling consisted of 2 days of H2S grab-samples, 7 days of continuous logging of inlet and outlet H2S and 2 days of bag sampling to be analyzed by an odor panel. All scheduled sampling events for the Jamaica Biofilter Pilot Project have concluded. The hydrogen sulfide removal efficiency met the 99.5% criterion for both grab samples and continuous monitoring. In addition, all outlet D/t were less than 350, also meeting the sampling criterion. Summarized results from both the summer and winter sampling events are delineated below.H2S removal efficiency was taken from the results of the 7-day continuous logging of the biofilter inlet and outlet. The averaged inlet concentrations and the averaged outlet concentrations over this period were used to determine the average removal efficiency. Total Odor analysis was provided by St. Croix Sensory of Minnesota.Summer Sampling Results:Average H2S Grab Sample Removal Efficiency – 99.73%Average H2S Continuous Sample Removal Efficiency – 99.72%Average Outlet Total Odor – 145 D/tWinter Sampling Results:Average H2S Grab Sample Removal Efficiency – 99.71%Average H2S Continuous Sample Removal Efficiency – 98.32%Average Outlet Total Odor – 127 D/tIt should be noted that for most of the sampling period, the outlet data logger did not record a detectable H2S concentration. The minimum threshold limit for the device is 0.01 ppm. Because of this, outlet concentrations that weren't detected were assumed to be 0.005 ppm (half the detection limit) to be conservative when calculating removal efficiency. The higher average inlet concentration during summer sampling (
Throughout the New York City Department of Environmental Protection (NYCDEP) wastewater treatment system, chemical scrubbers and/or carbon adsorption units have typically been used to treat odorous air emissions. Although these are adequate methods to remove Hydrogen Sulfide (H2S) and Volatile Organic Compound (VOC) constituents that compose malodorous emissions, the need for simpler, more...
Author(s)
Jane AtkinsonJonathan ThompsonJames G. MuellerJim Joyce
SourceProceedings of the Water Environment Federation
SubjectSession 4: Biological Odor Control
Document typeConference Paper
PublisherWater Environment Federation
Print publication date Jan, 2008
ISSN1938-6478
SICI1938-6478(20080101)2008:4L.247;1-
DOI10.2175/193864708788807736
Volume / Issue2008 / 4
Content sourceOdors and Air Pollutants Conference
First / last page(s)247 - 271
Copyright2008
Word count742

Purchase price $11.50

Get access
Log in Purchase content Purchase subscription
You may already have access to this content if you have previously purchased this content or have a subscription.
Need to create an account?

You can purchase access to this content but you might want to consider a subscription for a wide variety of items at a substantial discount!

Purchase access to 'Pilot Study for the Applicability of Biofilter Odor Control Technology for use at New York City Water Pollution Control Plants'

Add to cart
Purchase a subscription to gain access to 18,000+ Proceeding Papers, 25+ Fact Sheets, 20+ Technical Reports, 50+ magazine articles and select Technical Publications' chapters.
Loading items
There are no items to display at the moment.
Something went wrong trying to load these items.
Description: Book cover
Pilot Study for the Applicability of Biofilter Odor Control Technology for use at New York City Water Pollution Control Plants
Pricing
Non-member price: $11.50
Member price:
-295578
Get access
-295578
Log in Purchase content Purchase subscription
You may already have access to this content if you have previously purchased this content or have a subscription.
Need to create an account?

You can purchase access to this content but you might want to consider a subscription for a wide variety of items at a substantial discount!

Purchase access to 'Pilot Study for the Applicability of Biofilter Odor Control Technology for use at New York City Water Pollution Control Plants'

Add to cart
Purchase a subscription to gain access to 18,000+ Proceeding Papers, 25+ Fact Sheets, 20+ Technical Reports, 50+ magazine articles and select Technical Publications' chapters.

Details

Description: Book cover
Pilot Study for the Applicability of Biofilter Odor Control Technology for use at New York City Water Pollution Control Plants
Abstract
Throughout the New York City Department of Environmental Protection (NYCDEP) wastewater treatment system, chemical scrubbers and/or carbon adsorption units have typically been used to treat odorous air emissions. Although these are adequate methods to remove Hydrogen Sulfide (H2S) and Volatile Organic Compound (VOC) constituents that compose malodorous emissions, the need for simpler, more economical, and environmentally-friendly technologies has come to light.Preceding major upgrades of the Jamaica Water Pollution Control Plant's odor control system scheduled to be implemented by 2012, NYCDEP has authorized this Pilot Program utilizing Biofilter technology at the Jamaica plant. The Jamaica Biofilter Pilot Program allows the opportunity to demonstrate the applicability of Biofilters within the rigid NYCDEP wastewater treatment system, proving their efficiency and cost effectiveness. Future odor control upgrades at Jamaica must provide sufficient treatment to maintain adherence to the New York State Department of Environmental Conservation's regulatory requirement of less than 10 ppb of H2S at the fenceline of the plant and also NYCDEP guidance that requires less than 1 ppb of H2S at sensitive receptors.Previous studies of H2S emissions at wastewater treatment plants has shown that the major source of H2S emissions in wastewater treatment is the effluent weir section of the of the primary clarifier tanks. This is due to the large concentration of reduced sulfur compounds produced within the sludge beds of the clarifier tanks that is then released as H2S when turbulence exposes the sulfur compounds to air allowing the gas to then escape. The outfall of the effluent weirs is the primary location of this release. For this Pilot Program, the effluent weir section of one primary settling tank at the Jamaica WPCP has been isolated, drawing the odorous air into the Biofilter unit. H2S levels under these tank covers were monitored in the fall of 2006 and have found an average concentration of 0.5 parts per million (ppm) and a peak concentration of 4.2 ppm H2S.Based on the amount of airflow expected from this weir section and the target removal efficiency, the Biofilter unit was sized at 600 cubic feet of organic media. This size unit provides approximately 60 seconds of Empty Bed Contact Time (EBCT). Based on previous studies, this retention time should allow for 99.5% removal efficiency of H2S plus substantial removal of VOC's as well although VOCs were not targeted for performance criteria.The Pilot was in operation for one year. As part of the sampling protocol, two rounds of testing were conducted: one in summer, one in winter. This sampling was conducted to verify that the biofilter has the ability to meet strict removal criteria for both hydrogen sulfide (H2S) and dilutions-to-threshold (D/t) of Total Odor. The criteria are as follows:Hydrogen sulfide: minimum 99.5% removal or 0.025 ppm H2S maximum outlet concentration.Total odor: D/t ≤ 350, or 350 ≤ D/t ≤ 500 with a neutral or positive hedonic tone.Sampling consisted of 2 days of H2S grab-samples, 7 days of continuous logging of inlet and outlet H2S and 2 days of bag sampling to be analyzed by an odor panel. All scheduled sampling events for the Jamaica Biofilter Pilot Project have concluded. The hydrogen sulfide removal efficiency met the 99.5% criterion for both grab samples and continuous monitoring. In addition, all outlet D/t were less than 350, also meeting the sampling criterion. Summarized results from both the summer and winter sampling events are delineated below.H2S removal efficiency was taken from the results of the 7-day continuous logging of the biofilter inlet and outlet. The averaged inlet concentrations and the averaged outlet concentrations over this period were used to determine the average removal efficiency. Total Odor analysis was provided by St. Croix Sensory of Minnesota.Summer Sampling Results:Average H2S Grab Sample Removal Efficiency – 99.73%Average H2S Continuous Sample Removal Efficiency – 99.72%Average Outlet Total Odor – 145 D/tWinter Sampling Results:Average H2S Grab Sample Removal Efficiency – 99.71%Average H2S Continuous Sample Removal Efficiency – 98.32%Average Outlet Total Odor – 127 D/tIt should be noted that for most of the sampling period, the outlet data logger did not record a detectable H2S concentration. The minimum threshold limit for the device is 0.01 ppm. Because of this, outlet concentrations that weren't detected were assumed to be 0.005 ppm (half the detection limit) to be conservative when calculating removal efficiency. The higher average inlet concentration during summer sampling (
Throughout the New York City Department of Environmental Protection (NYCDEP) wastewater treatment system, chemical scrubbers and/or carbon adsorption units have typically been used to treat odorous air emissions. Although these are adequate methods to remove Hydrogen Sulfide (H2S) and Volatile Organic Compound (VOC) constituents that compose malodorous emissions, the need for simpler, more...
Author(s)
Jane AtkinsonJonathan ThompsonJames G. MuellerJim Joyce
SourceProceedings of the Water Environment Federation
SubjectSession 4: Biological Odor Control
Document typeConference Paper
PublisherWater Environment Federation
Print publication date Jan, 2008
ISSN1938-6478
SICI1938-6478(20080101)2008:4L.247;1-
DOI10.2175/193864708788807736
Volume / Issue2008 / 4
Content sourceOdors and Air Pollutants Conference
First / last page(s)247 - 271
Copyright2008
Word count742

Actions, changes & tasks

Outstanding Actions

Add action for paragraph

Current Changes

Add signficant change

Current Tasks

Add risk task

Connect with us

Follow us on Facebook
Follow us on Twitter
Connect to us on LinkedIn
Subscribe on YouTube
Powered by Librios Ltd
Powered by Librios Ltd
Authors
Terms of Use
Policies
Help
Accessibility
Contact us
Copyright © 2026 by the Water Environment Federation
Loading items
There are no items to display at the moment.
Something went wrong trying to load these items.
Description: WWTF Digital Boot 180x150
WWTF Digital (180x150)
Created on Jul 02
Websitehttps:/­/­www.wef.org/­wwtf?utm_medium=WWTF&utm_source=AccessWater&utm_campaign=WWTF
180x150
Jane Atkinson# Jonathan Thompson# James G. Mueller# Jim Joyce. Pilot Study for the Applicability of Biofilter Odor Control Technology for use at New York City Water Pollution Control Plants. Alexandria, VA 22314-1994, USA: Water Environment Federation, 2018. Web. 1 Apr. 2026. <https://www.accesswater.org?id=-295578CITANCHOR>.
Jane Atkinson# Jonathan Thompson# James G. Mueller# Jim Joyce. Pilot Study for the Applicability of Biofilter Odor Control Technology for use at New York City Water Pollution Control Plants. Alexandria, VA 22314-1994, USA: Water Environment Federation, 2018. Accessed April 1, 2026. https://www.accesswater.org/?id=-295578CITANCHOR.
Jane Atkinson# Jonathan Thompson# James G. Mueller# Jim Joyce
Pilot Study for the Applicability of Biofilter Odor Control Technology for use at New York City Water Pollution Control Plants
Access Water
Water Environment Federation
December 22, 2018
April 1, 2026
https://www.accesswater.org/?id=-295578CITANCHOR