lastID = -282585
Skip to main content Skip to top navigation Skip to site search
Top of page
  • My citations options
    Web Back (from Web)
    Chicago Back (from Chicago)
    MLA Back (from MLA)
Close action menu

You need to login to use this feature.

Please wait a moment…
Please wait while we update your results...
Please wait a moment...
Loading icon
Description: Access Water
Context Menu
Description: Explaining Sources of Biosolids Odors at Wastewater Treatment Plant (WWTP) by...
Explaining Sources of Biosolids Odors at Wastewater Treatment Plant (WWTP) by Utilizing Real-Time Odor Monitoring System and Statistical Models
  • Browse
  • Compilations
    • Compilations list
  • Subscriptions
Tools

Related contents

Loading related content

Workflow

No linked records yet

X
  • Current: 2022-05-04 15:04:49 Adam Phillips
  • 2022-05-04 15:04:48 Adam Phillips
  • 2020-03-30 23:45:38 Adam Phillips
  • 2020-03-30 23:45:37 Adam Phillips
  • 2020-03-30 20:56:56 Adam Phillips
  • 2020-03-30 20:56:55 Adam Phillips
  • 2020-03-27 16:46:12 Katherine Saltzman
  • 2020-03-27 16:46:10 Katherine Saltzman
  • 2020-03-27 01:18:53 Adam Phillips
  • 2020-03-27 01:18:51 Adam Phillips
  • 2020-01-31 22:59:28 Administrator
  • 2020-01-31 22:59:27 Administrator
Description: Access Water
  • Browse
  • Compilations
  • Subscriptions
Log in
0
Accessibility Options

Base text size -

This is a sample piece of body text
Larger
Smaller
  • Shopping basket (0)
  • Accessibility options
  • Return to previous
Description: Explaining Sources of Biosolids Odors at Wastewater Treatment Plant (WWTP) by...
Explaining Sources of Biosolids Odors at Wastewater Treatment Plant (WWTP) by Utilizing Real-Time Odor Monitoring System and Statistical Models

Explaining Sources of Biosolids Odors at Wastewater Treatment Plant (WWTP) by Utilizing Real-Time Odor Monitoring System and Statistical Models

Explaining Sources of Biosolids Odors at Wastewater Treatment Plant (WWTP) by Utilizing Real-Time Odor Monitoring System and Statistical Models

  • New
  • View
  • Details
  • Reader
  • Default
  • Share
  • Email
  • Facebook
  • Twitter
  • LinkedIn
  • New
  • View
  • Default view
  • Reader view
  • Data view
  • Details

This page cannot be printed from here

Please use the dedicated print option from the 'view' drop down menu located in the blue ribbon in the top, right section of the publication.

screenshot of print menu option

Description: Explaining Sources of Biosolids Odors at Wastewater Treatment Plant (WWTP) by...
Explaining Sources of Biosolids Odors at Wastewater Treatment Plant (WWTP) by Utilizing Real-Time Odor Monitoring System and Statistical Models
Abstract
A real-time solids odor monitoring system provides an odor management feedback tool for both process control and a biosolids management program. Since higher odor levels means higher process costs, as well as greater potential for nuisance odors at land application sites, identifying the processes that contribute to these elevated levels is critical to responsible, economical, and efficient wastewater plant management and biosolids land application programs. Each year, DC Water’s 370 mgd plant applies biosolids to over 20,000 acres of agricultural land. Nuisance odors from recycling biosolids on land may drift into surrounding neighborhoods and motivate neighboring communities to enact legislation to ban land application. Therefore, the reduction of odor emissions from biosolids recycled on field sites is a major concern. Odors levels generated by dewatered solids and limed biosolids are measured by headspace monitoring devices in enclosed conveyance systems. Both total reduced sulfur compounds (TRS) and nitrogen (N)- containing compounds are measured with online electro-chemical sensors. The system correlates odorant levels of dewatered solids and biosolids and utilizes treatment process scenarios and various operational parameters throughout the wastewater treatment process. This study uses ordinary least squares (OLS) estimation and instrumental variable (IV) estimation to create explanatory models. Data analyses suggest that waste-activated percent solids (WAS %S) and dissolved-air flotation total solids (DAF TS) can contribute to mitigating TRS. However, all process variables at secondary sedimentation, which are gravity thickening percent solids (GT %S), gravity total solids (GT TS), and blend ratio, can contribute to increase TRS. The IV estimation indicates that % lime feeding, # centrifuges, cake percent solids (Cake %S), temperature at secondary effluent, and ambient temperature cannot directly explain TRS postlime, but they do explain TRS levels via post-lime temperature. Additionally, cationic polymer at the secondary and dewatering process coupled with post lime temperature can contribute to increase N-containing compounds at the lime addition process. The accumulated cationic polymer inside the sludge of secondary sedimentation can also contribute to high N-containing compounds downstream.
A real-time solids odor monitoring system provides an odor management feedback tool for both process control and a biosolids management program. Since higher odor levels means higher process costs, as well as greater potential for nuisance odors at land application sites, identifying the processes that contribute to these elevated levels is critical to responsible, economical, and efficient...
Author(s)
Ampun JanpengpenTortrakul YomnakMark RamirezChristopher PeotTawiwat Veeraklaew
SourceProceedings of the Water Environment Federation
Document typeConference Paper
PublisherWater Environment Federation
Print publication date May, 2014
ISSN1938-6478
DOI10.2175/193864714816196899
Volume / Issue2014 / 2
Content sourceResiduals and Biosolids Conference
Copyright2014
Word count344

Purchase price $11.50

Get access
Log in Purchase content Purchase subscription
You may already have access to this content if you have previously purchased this content or have a subscription.
Need to create an account?

You can purchase access to this content but you might want to consider a subscription for a wide variety of items at a substantial discount!

Purchase access to 'Explaining Sources of Biosolids Odors at Wastewater Treatment Plant (WWTP) by Utilizing Real-Time Odor Monitoring System and Statistical Models'

Add to cart
Purchase a subscription to gain access to 18,000+ Proceeding Papers, 25+ Fact Sheets, 20+ Technical Reports, 50+ magazine articles and select Technical Publications' chapters.
Loading items
There are no items to display at the moment.
Something went wrong trying to load these items.
Description: Explaining Sources of Biosolids Odors at Wastewater Treatment Plant (WWTP) by...
Explaining Sources of Biosolids Odors at Wastewater Treatment Plant (WWTP) by Utilizing Real-Time Odor Monitoring System and Statistical Models
Pricing
Non-member price: $11.50
Member price:
-282585
Get access
-282585
Log in Purchase content Purchase subscription
You may already have access to this content if you have previously purchased this content or have a subscription.
Need to create an account?

You can purchase access to this content but you might want to consider a subscription for a wide variety of items at a substantial discount!

Purchase access to 'Explaining Sources of Biosolids Odors at Wastewater Treatment Plant (WWTP) by Utilizing Real-Time Odor Monitoring System and Statistical Models'

Add to cart
Purchase a subscription to gain access to 18,000+ Proceeding Papers, 25+ Fact Sheets, 20+ Technical Reports, 50+ magazine articles and select Technical Publications' chapters.

Details

Description: Explaining Sources of Biosolids Odors at Wastewater Treatment Plant (WWTP) by...
Explaining Sources of Biosolids Odors at Wastewater Treatment Plant (WWTP) by Utilizing Real-Time Odor Monitoring System and Statistical Models
Abstract
A real-time solids odor monitoring system provides an odor management feedback tool for both process control and a biosolids management program. Since higher odor levels means higher process costs, as well as greater potential for nuisance odors at land application sites, identifying the processes that contribute to these elevated levels is critical to responsible, economical, and efficient wastewater plant management and biosolids land application programs. Each year, DC Water’s 370 mgd plant applies biosolids to over 20,000 acres of agricultural land. Nuisance odors from recycling biosolids on land may drift into surrounding neighborhoods and motivate neighboring communities to enact legislation to ban land application. Therefore, the reduction of odor emissions from biosolids recycled on field sites is a major concern. Odors levels generated by dewatered solids and limed biosolids are measured by headspace monitoring devices in enclosed conveyance systems. Both total reduced sulfur compounds (TRS) and nitrogen (N)- containing compounds are measured with online electro-chemical sensors. The system correlates odorant levels of dewatered solids and biosolids and utilizes treatment process scenarios and various operational parameters throughout the wastewater treatment process. This study uses ordinary least squares (OLS) estimation and instrumental variable (IV) estimation to create explanatory models. Data analyses suggest that waste-activated percent solids (WAS %S) and dissolved-air flotation total solids (DAF TS) can contribute to mitigating TRS. However, all process variables at secondary sedimentation, which are gravity thickening percent solids (GT %S), gravity total solids (GT TS), and blend ratio, can contribute to increase TRS. The IV estimation indicates that % lime feeding, # centrifuges, cake percent solids (Cake %S), temperature at secondary effluent, and ambient temperature cannot directly explain TRS postlime, but they do explain TRS levels via post-lime temperature. Additionally, cationic polymer at the secondary and dewatering process coupled with post lime temperature can contribute to increase N-containing compounds at the lime addition process. The accumulated cationic polymer inside the sludge of secondary sedimentation can also contribute to high N-containing compounds downstream.
A real-time solids odor monitoring system provides an odor management feedback tool for both process control and a biosolids management program. Since higher odor levels means higher process costs, as well as greater potential for nuisance odors at land application sites, identifying the processes that contribute to these elevated levels is critical to responsible, economical, and efficient...
Author(s)
Ampun JanpengpenTortrakul YomnakMark RamirezChristopher PeotTawiwat Veeraklaew
SourceProceedings of the Water Environment Federation
Document typeConference Paper
PublisherWater Environment Federation
Print publication date May, 2014
ISSN1938-6478
DOI10.2175/193864714816196899
Volume / Issue2014 / 2
Content sourceResiduals and Biosolids Conference
Copyright2014
Word count344

Actions, changes & tasks

Outstanding Actions

Add action for paragraph

Current Changes

Add signficant change

Current Tasks

Add risk task

Connect with us

Follow us on Facebook
Follow us on Twitter
Connect to us on LinkedIn
Subscribe on YouTube
Powered by Librios Ltd
Powered by Librios Ltd
Authors
Terms of Use
Policies
Help
Accessibility
Contact us
Copyright © 2026 by the Water Environment Federation
Loading items
There are no items to display at the moment.
Something went wrong trying to load these items.
Description: WWTF Digital Boot 180x150
WWTF Digital (180x150)
Created on Jul 02
Websitehttps:/­/­www.wef.org/­wwtf?utm_medium=WWTF&utm_source=AccessWater&utm_campaign=WWTF
180x150
Ampun Janpengpen# Tortrakul Yomnak# Mark Ramirez# Christopher Peot# Tawiwat Veeraklaew. Explaining Sources of Biosolids Odors at Wastewater Treatment Plant (WWTP) by Utilizing Real-Time Odor Monitoring System and Statistical Models. Alexandria, VA 22314-1994, USA: Water Environment Federation, 2018. Web. 1 Apr. 2026. <https://www.accesswater.org?id=-282585CITANCHOR>.
Ampun Janpengpen# Tortrakul Yomnak# Mark Ramirez# Christopher Peot# Tawiwat Veeraklaew. Explaining Sources of Biosolids Odors at Wastewater Treatment Plant (WWTP) by Utilizing Real-Time Odor Monitoring System and Statistical Models. Alexandria, VA 22314-1994, USA: Water Environment Federation, 2018. Accessed April 1, 2026. https://www.accesswater.org/?id=-282585CITANCHOR.
Ampun Janpengpen# Tortrakul Yomnak# Mark Ramirez# Christopher Peot# Tawiwat Veeraklaew
Explaining Sources of Biosolids Odors at Wastewater Treatment Plant (WWTP) by Utilizing Real-Time Odor Monitoring System and Statistical Models
Access Water
Water Environment Federation
December 22, 2018
April 1, 2026
https://www.accesswater.org/?id=-282585CITANCHOR