lastID = -288882
Skip to main content Skip to top navigation Skip to site search
Top of page
  • My citations options
    Web Back (from Web)
    Chicago Back (from Chicago)
    MLA Back (from MLA)
Close action menu

You need to login to use this feature.

Please wait a moment…
Please wait while we update your results...
Please wait a moment...
Description: Access Water
Context Menu
Description: Book cover
HOW TO CONNECT A NEW SEWER LINE TO AN EXISTING 72-INCH SEWER WHILE FLOWING AT 2/3 FULL AND OVER 13 FPS
  • Browse
  • Compilations
    • Compilations list
  • Subscriptions
Tools

Related contents

Loading related content

Workflow

No linked records yet

X
  • Current: 2022-05-06 11:32:21 Adam Phillips
  • 2022-05-06 11:32:20 Adam Phillips
  • 2020-01-31 23:57:16 Administrator
  • 2020-01-31 23:57:15 Administrator
  • 2020-01-31 23:57:14 Administrator
Description: Access Water
  • Browse
  • Compilations
  • Subscriptions
Log in
0
Accessibility Options

Base text size -

This is a sample piece of body text
Larger
Smaller
  • Shopping basket (0)
  • Accessibility options
  • Return to previous
Description: Book cover
HOW TO CONNECT A NEW SEWER LINE TO AN EXISTING 72-INCH SEWER WHILE FLOWING AT 2/3 FULL AND OVER 13 FPS

HOW TO CONNECT A NEW SEWER LINE TO AN EXISTING 72-INCH SEWER WHILE FLOWING AT 2/3 FULL AND OVER 13 FPS

HOW TO CONNECT A NEW SEWER LINE TO AN EXISTING 72-INCH SEWER WHILE FLOWING AT 2/3 FULL AND OVER 13 FPS

  • New
  • View
  • Details
  • Reader
  • Default
  • Share
  • Email
  • Facebook
  • Twitter
  • LinkedIn
  • New
  • View
  • Default view
  • Reader view
  • Data view
  • Details

This page cannot be printed from here

Please use the dedicated print option from the 'view' drop down menu located in the blue ribbon in the top, right section of the publication.

screenshot of print menu option

Description: Book cover
HOW TO CONNECT A NEW SEWER LINE TO AN EXISTING 72-INCH SEWER WHILE FLOWING AT 2/3 FULL AND OVER 13 FPS
Abstract
The Rosewood Willoughby relief sewer project consisted of installing two miles of 45-inch sewer line to relieve a sewer line in Melrose Ave. that was flowing at 90% full. The new sewer line would intercept several sewers tributary to the Melrose sewer at the upstream end and discharge to the La Cienega San Fernando Valley Relief Sewer (LCSVRS) at the downstream end. The LCSVRS is 72-inch in diameter and is flowing at 2/3 full and at 13 fps.The flow in the LCSVRS was a changed condition to the contract. During design, the LCSVRS was gauged at less than 1/3 full at peak flow. Additional flows and a changed method of sewer operation caused a major change from the original concept and created a situation where the originally designed tie-in would not work.A change order was issued to the contractor modifying the method of the connection. The new method directed the contractor to excavate around the 72-inch pipe, support in place, form and build a cast in place concrete box around the pipe. A precast lined concrete insert, shaped like a half 72-inch pipe that would then serve as a continuation of the pipe was built. The idea was to saw-cut both ends of the pipe, lift the pipe, let the flow run in the box and then place the insert in the box. Once the insert was in the box, grout it securely and then place a precast cover on the new junction structure.The tie-in work happened over a 2-day period and was successful with minor delays. The actual tie-in was made at night. Odor controls, sewage spill mitigation, noise barriers and public relations efforts were put in place prior to the tie-in operation.The design of the junction structure has become the standard design for all major sewers where flow bypass is not an option. The method is cost effective, clean and minimally disruptive to nearby residents and businesses.
The Rosewood Willoughby relief sewer project consisted of installing two miles of 45-inch sewer line to relieve a sewer line in Melrose Ave. that was flowing at 90% full. The new sewer line would intercept several sewers tributary to the Melrose sewer at the upstream end and discharge to the La Cienega San Fernando Valley Relief Sewer (LCSVRS) at the downstream end. The LCSVRS is 72-inch in...
Author(s)
Samara Ali-AhmadKeith Hanks
SourceProceedings of the Water Environment Federation
SubjectSession 47 - Collection Systems Symposium: Can We Build It? Yes We Can!
Document typeConference Paper
PublisherWater Environment Federation
Print publication date Jan, 2002
ISSN1938-6478
SICI1938-6478(20020101)2002:13L.494;1-
DOI10.2175/193864702784163056
Volume / Issue2002 / 13
Content sourceWEFTEC
First / last page(s)494 - 504
Copyright2002
Word count340

Purchase price $11.50

Get access
Log in Purchase content Purchase subscription
You may already have access to this content if you have previously purchased this content or have a subscription.
Need to create an account?

You can purchase access to this content but you might want to consider a subscription for a wide variety of items at a substantial discount!

Purchase access to 'HOW TO CONNECT A NEW SEWER LINE TO AN EXISTING 72-INCH SEWER WHILE FLOWING AT 2/3 FULL AND OVER 13 FPS'

Add to cart
Purchase a subscription to gain access to 18,000+ Proceeding Papers, 25+ Fact Sheets, 20+ Technical Reports, 50+ magazine articles and select Technical Publications' chapters.
Loading items
There are no items to display at the moment.
Something went wrong trying to load these items.
Description: Book cover
HOW TO CONNECT A NEW SEWER LINE TO AN EXISTING 72-INCH SEWER WHILE FLOWING AT 2/3 FULL AND OVER 13 FPS
Pricing
Non-member price: $11.50
Member price:
-288882
Get access
-288882
Log in Purchase content Purchase subscription
You may already have access to this content if you have previously purchased this content or have a subscription.
Need to create an account?

You can purchase access to this content but you might want to consider a subscription for a wide variety of items at a substantial discount!

Purchase access to 'HOW TO CONNECT A NEW SEWER LINE TO AN EXISTING 72-INCH SEWER WHILE FLOWING AT 2/3 FULL AND OVER 13 FPS'

Add to cart
Purchase a subscription to gain access to 18,000+ Proceeding Papers, 25+ Fact Sheets, 20+ Technical Reports, 50+ magazine articles and select Technical Publications' chapters.

Details

Description: Book cover
HOW TO CONNECT A NEW SEWER LINE TO AN EXISTING 72-INCH SEWER WHILE FLOWING AT 2/3 FULL AND OVER 13 FPS
Abstract
The Rosewood Willoughby relief sewer project consisted of installing two miles of 45-inch sewer line to relieve a sewer line in Melrose Ave. that was flowing at 90% full. The new sewer line would intercept several sewers tributary to the Melrose sewer at the upstream end and discharge to the La Cienega San Fernando Valley Relief Sewer (LCSVRS) at the downstream end. The LCSVRS is 72-inch in diameter and is flowing at 2/3 full and at 13 fps.The flow in the LCSVRS was a changed condition to the contract. During design, the LCSVRS was gauged at less than 1/3 full at peak flow. Additional flows and a changed method of sewer operation caused a major change from the original concept and created a situation where the originally designed tie-in would not work.A change order was issued to the contractor modifying the method of the connection. The new method directed the contractor to excavate around the 72-inch pipe, support in place, form and build a cast in place concrete box around the pipe. A precast lined concrete insert, shaped like a half 72-inch pipe that would then serve as a continuation of the pipe was built. The idea was to saw-cut both ends of the pipe, lift the pipe, let the flow run in the box and then place the insert in the box. Once the insert was in the box, grout it securely and then place a precast cover on the new junction structure.The tie-in work happened over a 2-day period and was successful with minor delays. The actual tie-in was made at night. Odor controls, sewage spill mitigation, noise barriers and public relations efforts were put in place prior to the tie-in operation.The design of the junction structure has become the standard design for all major sewers where flow bypass is not an option. The method is cost effective, clean and minimally disruptive to nearby residents and businesses.
The Rosewood Willoughby relief sewer project consisted of installing two miles of 45-inch sewer line to relieve a sewer line in Melrose Ave. that was flowing at 90% full. The new sewer line would intercept several sewers tributary to the Melrose sewer at the upstream end and discharge to the La Cienega San Fernando Valley Relief Sewer (LCSVRS) at the downstream end. The LCSVRS is 72-inch in...
Author(s)
Samara Ali-AhmadKeith Hanks
SourceProceedings of the Water Environment Federation
SubjectSession 47 - Collection Systems Symposium: Can We Build It? Yes We Can!
Document typeConference Paper
PublisherWater Environment Federation
Print publication date Jan, 2002
ISSN1938-6478
SICI1938-6478(20020101)2002:13L.494;1-
DOI10.2175/193864702784163056
Volume / Issue2002 / 13
Content sourceWEFTEC
First / last page(s)494 - 504
Copyright2002
Word count340

Actions, changes & tasks

Outstanding Actions

Add action for paragraph

Current Changes

Add signficant change

Current Tasks

Add risk task

Connect with us

Follow us on Facebook
Follow us on Twitter
Connect to us on LinkedIn
Subscribe on YouTube
Powered by Librios Ltd
Powered by Librios Ltd
Authors
Terms of Use
Policies
Help
Accessibility
Contact us
Copyright © 2024 by the Water Environment Federation
Loading items
There are no items to display at the moment.
Something went wrong trying to load these items.
Description: WWTF Digital Boot 180x150
WWTF Digital (180x150)
Created on Jul 02
Websitehttps:/­/­www.wef.org/­wwtf?utm_medium=WWTF&utm_source=AccessWater&utm_campaign=WWTF
180x150
Samara Ali-Ahmad# Keith Hanks. HOW TO CONNECT A NEW SEWER LINE TO AN EXISTING 72-INCH SEWER WHILE FLOWING AT 2/3 FULL AND OVER 13 FPS. Alexandria, VA 22314-1994, USA: Water Environment Federation, 2018. Web. 8 Jun. 2025. <https://www.accesswater.org?id=-288882CITANCHOR>.
Samara Ali-Ahmad# Keith Hanks. HOW TO CONNECT A NEW SEWER LINE TO AN EXISTING 72-INCH SEWER WHILE FLOWING AT 2/3 FULL AND OVER 13 FPS. Alexandria, VA 22314-1994, USA: Water Environment Federation, 2018. Accessed June 8, 2025. https://www.accesswater.org/?id=-288882CITANCHOR.
Samara Ali-Ahmad# Keith Hanks
HOW TO CONNECT A NEW SEWER LINE TO AN EXISTING 72-INCH SEWER WHILE FLOWING AT 2/3 FULL AND OVER 13 FPS
Access Water
Water Environment Federation
December 22, 2018
June 8, 2025
https://www.accesswater.org/?id=-288882CITANCHOR