lastID = -10091932
Skip to main content Skip to top navigation Skip to site search
Top of page
  • My citations options
    Web Back (from Web)
    Chicago Back (from Chicago)
    MLA Back (from MLA)
Close action menu

You need to login to use this feature.

Please wait a moment…
Please wait while we update your results...
Please wait a moment...
Description: Access Water
Context Menu
Description: Odors and Air Pollutants 2023 cover
Bakersfield's Odor Control Breakthrough: SulFeLox Saves Money, Improves Performance
  • Browse
  • Compilations
    • Compilations list
  • Subscriptions
Tools

Related contents

Loading related content

Workflow

No linked records yet

X
  • Current: 2023-05-12 15:50:58 Adam Phillips Release
  • 2023-05-03 11:33:08 Adam Phillips
Description: Access Water
  • Browse
  • Compilations
  • Subscriptions
Log in
0
Accessibility Options

Base text size -

This is a sample piece of body text
Larger
Smaller
  • Shopping basket (0)
  • Accessibility options
  • Return to previous
Description: Odors and Air Pollutants 2023 cover
Bakersfield's Odor Control Breakthrough: SulFeLox Saves Money, Improves Performance

Bakersfield's Odor Control Breakthrough: SulFeLox Saves Money, Improves Performance

Bakersfield's Odor Control Breakthrough: SulFeLox Saves Money, Improves Performance

  • New
  • View
  • Details
  • Reader
  • Default
  • Share
  • Email
  • Facebook
  • Twitter
  • LinkedIn
  • New
  • View
  • Default view
  • Reader view
  • Data view
  • Details

This page cannot be printed from here

Please use the dedicated print option from the 'view' drop down menu located in the blue ribbon in the top, right section of the publication.

screenshot of print menu option

Description: Odors and Air Pollutants 2023 cover
Bakersfield's Odor Control Breakthrough: SulFeLox Saves Money, Improves Performance
Abstract
Faced with increasing costs for controlling hydrogen sulfide in its wastewater collection system, the City of Bakersfield, California commissioned an evaluation of its odor control program in 2019. Among the consultant recommendations was to consider using a more efficient treatment (ferrous chloride) in place of certain of the existing Calcium Nitrate dosing stations where costs were constrained. A particular priority were those stations along the higher flow interceptor segment where chemical demands and community sensitivities were highest. An expected benefit of iron dosing is its durational control capability, which should translate into fewer dosing stations. Consequently, field testing was suggested to assess the cost-benefit. As siting dosing stations for ferrous chloride solutions can be limited (due to the corrosivity of the product), a low-hazard form of ferrous chloride, SulFeLox®, was used. The study was conducted from April to June, 2021, and consisted of 12 days monitoring of the baseline Calcium Nitrate scenario, followed by 60 days of SulFeLox dosing at different feed rates, and concluding with 14 days of no chemical dosing (i.e., the true baseline scenario). The interceptor selected for the test was a 10-mile (5-6 hour retention), 12 mgd trunkline leading to the City's Plant No. 3 (Figure 1). The particular segment of focus begins where the discharge from the Romero PS (S1) enters the interceptor and ends at the Buena Vista PS (S2) approximately 3 miles (2 hours) downstream. Controlling vapor-H2S levels at the Buena Vista PS was the primary measure of success. To assess the durational control aspects of each chemical, sampling was also performed another 3-4 miles downstream at the McCutcheon PS (S3) - just ahead of the treatment plant (S4). In this study, the SulFeLox dosing station replaced two Calcium Nitrate stations: 1) at the Romero site (S1), and 2) at the Buena Vista site (S2). With Calcium Nitrate dosing (310 gpd, combined, from the two sites), the peak vapor-H2S levels recorded at the four sampling sites averaged 3, 94, 595, and 100 ppm (Figure 2a). The liquid-phase sulfide levels were 0.0, 2.9, 6.6, and 3.5 mg/L, respectively. With SulFeLox dosing (120-210 gpd), the peak vapor-H2S levels recorded at the four sampling sites averaged 0, 30, 652, and 31 ppm (Figure 2b). The liquid-phase sulfide levels were 0.0, 1.4, 4.7, and 2.3 mg/L, respectively. Comparing the Calcium Nitrate and SulFeLox results shows 66-83% lower vapor-H2S peaks at the Buena Vista (S2) and treatment plant (S4) sites, with less benefit at the McCutcheon site (S3) where vapors are impacted by H2S by other flows into the station. (Figure 2c). Site 2 (Buena Vista PS) is located in a particularly sensitive area, and prior tests suggested upstream Calcium Nitrate feed rates would need to be 500 gpd (or more) to maintain vapor-H2S levels below 25 ppm. Figure 3 shows the vapor-H2S results in this test, where SulFeLox feed rates of 120-210 gpd achieved the compliance targets and provided H2S reductions of 84-95% (relative to 146 gpd Calcium Nitrate). On a performance basis, the field results confirmed the consultant recommendation that (for system-wide H2S control) iron dosing from one site could provide improved results relative to Calcium Nitrate dosing from two sites. SulFeLox feed rates were determined that provide interceptor-wide H2S control to 25 ppm and 10 ppm. However, a direct cost comparison between the two treatment chemistries is complicated given that system-wide H2S control could not be demonstrated with Calcium Nitrate (per the 500 gpd test in a prior study). This present study did show, however, that the cost to control to target H2S levels using SulFeLox was $600-1000 per day, where the recurring cost for Calcium Nitrate was $850-950 per day (to control to the higher level of 100-140 ppm H2S). Subsequent to this field test, the City continued to feed SulFeLox at S1 (Romero PS) and has since replaced seven other Calcium Nitrate sites with three SulFeLox sites, reducing the total number of chemical feed sites from nine to four. As a result of this work, the City is now spending approximately $660 k/yr for SulFeLox to meet its system-wide performance targets, where it was previously spending $990 k/yr (for Calcium Nitrate). Further, with now a year's experience with dosing iron into the collection system, the treatment plant has observed operational benefits, including the elimination of need for ferric chloride feed to the plant digesters. Early in 2022, the City entered into a five-year supply agreement for providing SulFeLox iron product and related services and equipment. Future work is planned to evaluate iron regeneration ahead of the treatment plant (at McCutcheon PS, S3), recognizing that this trunkline comprises 70% of total plant flow but 100% of influent iron. Oxidizing the spent iron (as FeS) to hydrous ferric oxide (using hydrogen peroxide) is expected to provide additional benefit to treatment plant operations. Figures 1. Schematic of interceptor segment tested 2. Summary of field test results: Calcium Nitrate and SulFeLox rate performance 3. Buena Vista PS: Response of vapor-H2S levels to chemical feed rates (at the upstream Romero PS). 4. Buena Vista PS: Dose-Response summary comparison of SulFeLox to Calcium Nitrate.
This paper was presented at the WEF Odors and Air Pollutants Conference, May 16-19, 2023.
SpeakerCollins, Michael
Presentation time
8:30:00
9:00:00
Session time
8:30:00
10:00:00
SessionJust When You Thought There Was Nothing New: Odor Innovation
Session number12
Session locationCharlotte Convention Center, Charlotte, North Carolina, USA
TopicInnovative Treatment Approaches
TopicInnovative Treatment Approaches
Author(s)
M. Collins
Author(s)M. Collins 1; P. Huhn 1; L. Nguyen 1; I. Watson 1; K. Peoples 2; B. Stevens 2
Author affiliation(s)USP Technologies1; City of Bakersfield, CA2
SourceProceedings of the Water Environment Federation
Document typeConference Paper
PublisherWater Environment Federation
Print publication date May 2023
DOI10.2175/193864718825158766
Volume / Issue
Content sourceOdors and Air Pollutants
Copyright2023
Word count10

Purchase price $11.50

Get access
Log in Purchase content Purchase subscription
You may already have access to this content if you have previously purchased this content or have a subscription.
Need to create an account?

You can purchase access to this content but you might want to consider a subscription for a wide variety of items at a substantial discount!

Purchase access to 'Bakersfield's Odor Control Breakthrough: SulFeLox Saves Money, Improves Performance'

Add to cart
Purchase a subscription to gain access to 18,000+ Proceeding Papers, 25+ Fact Sheets, 20+ Technical Reports, 50+ magazine articles and select Technical Publications' chapters.
Loading items
There are no items to display at the moment.
Something went wrong trying to load these items.
Description: Odors and Air Pollutants 2023 cover
Bakersfield's Odor Control Breakthrough: SulFeLox Saves Money, Improves Performance
Pricing
Non-member price: $11.50
Member price:
-10091932
Get access
-10091932
Log in Purchase content Purchase subscription
You may already have access to this content if you have previously purchased this content or have a subscription.
Need to create an account?

You can purchase access to this content but you might want to consider a subscription for a wide variety of items at a substantial discount!

Purchase access to 'Bakersfield's Odor Control Breakthrough: SulFeLox Saves Money, Improves Performance'

Add to cart
Purchase a subscription to gain access to 18,000+ Proceeding Papers, 25+ Fact Sheets, 20+ Technical Reports, 50+ magazine articles and select Technical Publications' chapters.

Details

Description: Odors and Air Pollutants 2023 cover
Bakersfield's Odor Control Breakthrough: SulFeLox Saves Money, Improves Performance
Abstract
Faced with increasing costs for controlling hydrogen sulfide in its wastewater collection system, the City of Bakersfield, California commissioned an evaluation of its odor control program in 2019. Among the consultant recommendations was to consider using a more efficient treatment (ferrous chloride) in place of certain of the existing Calcium Nitrate dosing stations where costs were constrained. A particular priority were those stations along the higher flow interceptor segment where chemical demands and community sensitivities were highest. An expected benefit of iron dosing is its durational control capability, which should translate into fewer dosing stations. Consequently, field testing was suggested to assess the cost-benefit. As siting dosing stations for ferrous chloride solutions can be limited (due to the corrosivity of the product), a low-hazard form of ferrous chloride, SulFeLox®, was used. The study was conducted from April to June, 2021, and consisted of 12 days monitoring of the baseline Calcium Nitrate scenario, followed by 60 days of SulFeLox dosing at different feed rates, and concluding with 14 days of no chemical dosing (i.e., the true baseline scenario). The interceptor selected for the test was a 10-mile (5-6 hour retention), 12 mgd trunkline leading to the City's Plant No. 3 (Figure 1). The particular segment of focus begins where the discharge from the Romero PS (S1) enters the interceptor and ends at the Buena Vista PS (S2) approximately 3 miles (2 hours) downstream. Controlling vapor-H2S levels at the Buena Vista PS was the primary measure of success. To assess the durational control aspects of each chemical, sampling was also performed another 3-4 miles downstream at the McCutcheon PS (S3) - just ahead of the treatment plant (S4). In this study, the SulFeLox dosing station replaced two Calcium Nitrate stations: 1) at the Romero site (S1), and 2) at the Buena Vista site (S2). With Calcium Nitrate dosing (310 gpd, combined, from the two sites), the peak vapor-H2S levels recorded at the four sampling sites averaged 3, 94, 595, and 100 ppm (Figure 2a). The liquid-phase sulfide levels were 0.0, 2.9, 6.6, and 3.5 mg/L, respectively. With SulFeLox dosing (120-210 gpd), the peak vapor-H2S levels recorded at the four sampling sites averaged 0, 30, 652, and 31 ppm (Figure 2b). The liquid-phase sulfide levels were 0.0, 1.4, 4.7, and 2.3 mg/L, respectively. Comparing the Calcium Nitrate and SulFeLox results shows 66-83% lower vapor-H2S peaks at the Buena Vista (S2) and treatment plant (S4) sites, with less benefit at the McCutcheon site (S3) where vapors are impacted by H2S by other flows into the station. (Figure 2c). Site 2 (Buena Vista PS) is located in a particularly sensitive area, and prior tests suggested upstream Calcium Nitrate feed rates would need to be 500 gpd (or more) to maintain vapor-H2S levels below 25 ppm. Figure 3 shows the vapor-H2S results in this test, where SulFeLox feed rates of 120-210 gpd achieved the compliance targets and provided H2S reductions of 84-95% (relative to 146 gpd Calcium Nitrate). On a performance basis, the field results confirmed the consultant recommendation that (for system-wide H2S control) iron dosing from one site could provide improved results relative to Calcium Nitrate dosing from two sites. SulFeLox feed rates were determined that provide interceptor-wide H2S control to 25 ppm and 10 ppm. However, a direct cost comparison between the two treatment chemistries is complicated given that system-wide H2S control could not be demonstrated with Calcium Nitrate (per the 500 gpd test in a prior study). This present study did show, however, that the cost to control to target H2S levels using SulFeLox was $600-1000 per day, where the recurring cost for Calcium Nitrate was $850-950 per day (to control to the higher level of 100-140 ppm H2S). Subsequent to this field test, the City continued to feed SulFeLox at S1 (Romero PS) and has since replaced seven other Calcium Nitrate sites with three SulFeLox sites, reducing the total number of chemical feed sites from nine to four. As a result of this work, the City is now spending approximately $660 k/yr for SulFeLox to meet its system-wide performance targets, where it was previously spending $990 k/yr (for Calcium Nitrate). Further, with now a year's experience with dosing iron into the collection system, the treatment plant has observed operational benefits, including the elimination of need for ferric chloride feed to the plant digesters. Early in 2022, the City entered into a five-year supply agreement for providing SulFeLox iron product and related services and equipment. Future work is planned to evaluate iron regeneration ahead of the treatment plant (at McCutcheon PS, S3), recognizing that this trunkline comprises 70% of total plant flow but 100% of influent iron. Oxidizing the spent iron (as FeS) to hydrous ferric oxide (using hydrogen peroxide) is expected to provide additional benefit to treatment plant operations. Figures 1. Schematic of interceptor segment tested 2. Summary of field test results: Calcium Nitrate and SulFeLox rate performance 3. Buena Vista PS: Response of vapor-H2S levels to chemical feed rates (at the upstream Romero PS). 4. Buena Vista PS: Dose-Response summary comparison of SulFeLox to Calcium Nitrate.
This paper was presented at the WEF Odors and Air Pollutants Conference, May 16-19, 2023.
SpeakerCollins, Michael
Presentation time
8:30:00
9:00:00
Session time
8:30:00
10:00:00
SessionJust When You Thought There Was Nothing New: Odor Innovation
Session number12
Session locationCharlotte Convention Center, Charlotte, North Carolina, USA
TopicInnovative Treatment Approaches
TopicInnovative Treatment Approaches
Author(s)
M. Collins
Author(s)M. Collins 1; P. Huhn 1; L. Nguyen 1; I. Watson 1; K. Peoples 2; B. Stevens 2
Author affiliation(s)USP Technologies1; City of Bakersfield, CA2
SourceProceedings of the Water Environment Federation
Document typeConference Paper
PublisherWater Environment Federation
Print publication date May 2023
DOI10.2175/193864718825158766
Volume / Issue
Content sourceOdors and Air Pollutants
Copyright2023
Word count10

Actions, changes & tasks

Outstanding Actions

Add action for paragraph

Current Changes

Add signficant change

Current Tasks

Add risk task

Connect with us

Follow us on Facebook
Follow us on Twitter
Connect to us on LinkedIn
Subscribe on YouTube
Powered by Librios Ltd
Powered by Librios Ltd
Authors
Terms of Use
Policies
Help
Accessibility
Contact us
Copyright © 2024 by the Water Environment Federation
Loading items
There are no items to display at the moment.
Something went wrong trying to load these items.
Description: WWTF Digital Boot 180x150
WWTF Digital (180x150)
Created on Jul 02
Websitehttps:/­/­www.wef.org/­wwtf?utm_medium=WWTF&utm_source=AccessWater&utm_campaign=WWTF
180x150
M. Collins. Bakersfield's Odor Control Breakthrough: SulFeLox Saves Money, Improves Performance. Water Environment Federation, 2023. Web. 4 Jul. 2025. <https://www.accesswater.org?id=-10091932CITANCHOR>.
M. Collins. Bakersfield's Odor Control Breakthrough: SulFeLox Saves Money, Improves Performance. Water Environment Federation, 2023. Accessed July 4, 2025. https://www.accesswater.org/?id=-10091932CITANCHOR.
M. Collins
Bakersfield's Odor Control Breakthrough: SulFeLox Saves Money, Improves Performance
Access Water
Water Environment Federation
May 19, 2023
July 4, 2025
https://www.accesswater.org/?id=-10091932CITANCHOR