Access Water | Beyond Setpoints: Three Full-Scale Low DO Case Studies
lastID = -10128194
Skip to main content Skip to top navigation Skip to site search
Top of page
  • My citations options
    Web Back (from Web)
    Chicago Back (from Chicago)
    MLA Back (from MLA)
Close action menu

You need to login to use this feature.

Please wait a moment…
Please wait while we update your results...
Please wait a moment...
Loading icon
Description: Access Water
Context Menu
Description: Beyond Setpoints: Three Full-Scale Low DO Case Studies
Beyond Setpoints: Three Full-Scale Low DO Case Studies
  • Browse
  • Compilations
    • Compilations list
  • Subscriptions
Tools

Related contents

Loading related content

Workflow

No linked records yet

X
  • Current: 2026-09-25 14:53:09 Chris Lewis Continuous release
  • 2026-09-11 10:00:25 Adam Phillips
Description: Access Water
  • Browse
  • Compilations
  • Subscriptions
Log in
0
Accessibility Options

Base text size -

This is a sample piece of body text
Larger
Smaller
  • Shopping basket (0)
  • Accessibility options
  • Return to previous
Description: Beyond Setpoints: Three Full-Scale Low DO Case Studies
Beyond Setpoints: Three Full-Scale Low DO Case Studies

Beyond Setpoints: Three Full-Scale Low DO Case Studies

Beyond Setpoints: Three Full-Scale Low DO Case Studies

  • New
  • View
  • Details
  • Reader
  • Default
  • Share
  • Email
  • Facebook
  • Twitter
  • LinkedIn
  • New
  • View
  • Default view
  • Reader view
  • Data view
  • Details

This page cannot be printed from here

Please use the dedicated print option from the 'view' drop down menu located in the blue ribbon in the top, right section of the publication.

screenshot of print menu option

Description: Beyond Setpoints: Three Full-Scale Low DO Case Studies
Beyond Setpoints: Three Full-Scale Low DO Case Studies
Abstract
APPLICABILITY Aeration is the dominant energy consumer in biological nutrient removal systems, and conventional dissolved oxygen (DO) setpoints near 2 mg/L are commonly used to provide operational robustness. Interest in lower DO operation has rapidly increased to address several drivers, including: reduced energy costs, stringent nutrient limits, and optimized carbon addition. Although low DO operation (<1.0 mg/L) has demonstrated biological feasibility, full-scale adoption still faces practical implementation challenges. These include aeration system and control limitations, instrumentation performance at low DO, uncertainty related to sludge settleability, and reduced nitrification kinetics during cold-weather operation. Over the past two decades, low DO operation has progressed from theory and small pilot studies to full-scale demonstration and implementation. However, most recent conference presentations and publications continue to focus on theory, modeling, and kinetics, with limited attention to practical design and retrofit considerations for aeration hardware, instrumentation, and controls. As a result, there is little consolidated guidance on how to support low DO operation across different climates and drivers, including energy reduction, carbon efficiency, and more stringent nutrient limits. The objective of this work is to help address this gap through three full-scale case studies illustrating low DO implementation under real operating conditions. RESULTS AND OUTCOMES This presentation evaluates three full-scale facilities operating with low DO conditions. Two facilities are flow-through activated sludge systems- Avon Wastewater Treatment Facility (Avon) and Pomona Water Reclamation Plant (PWRP)- and one is a phased isolation ditch facility operated by Boxelder Sanitation District (BSD). Together, these facilities represent a range of process configurations, climates, aeration systems, instrumentation, and control approaches. Key facility characteristics are summarized in Table 1. At each facility, DO targets were reduced from typical operating DOs > 1.5 mg/L while maintaining stable performance. At PWRP, average DO was progressively lowered to an average of ~0.7 mg/L under highly diurnal loading conditions. Performance at PWRP reflects a highly instrumented system with multiple DO and ammonia probes, high blower turndown, and a responsive airflow control. Typical airflow control loop performance at PWRP demonstrates how instrumentation quality and airflow responsiveness enabled stable low DO operation under highly variable loading (Figure 1) At Avon, DO concentrations were reduced from ~2.0 mg/L to ~0.7 mg/L in 2025 using PID-based DO setpoint control, with short-term increases during the peak ski season to maintain winter nitrification capacity. Avon is also configured with external carbon addition to meet stringent nutrient limits, and operating data will be compared over the course of DO reduction. Physical system flexibility, including two droplegs per zone and a nested diffuser grid, supported improved air distribution at low airflow rates while maintaining adequate mixing (Figure 2). At BSD, operators reduced bulk DO to approximately 0.3 mg/L through time-based aeration sequencing and extended anoxic periods. All three facilities maintained compliance with effluent requirements during low DO operation. At PWRP, aeration energy was reduced by approximately 57% (Figure 3). At Avon, overall facility energy use decreased by approximately 33% compared to pre-upgrade baselines. At BSD, aeration energy was reduced by approximately 25% relative to 2016 baseline conditions. Using existing operating data and practical experience from full-scale facilities, this presentation will compare equipment selection across the three sites, including aeration hardware, blower configurations, airflow control components (valves and actuators), diffuser layouts, and instrumentation. The advantages and limitations of the different equipment and operational control strategies will also be evaluated. Results will be used to summarize how equipment selection, process configuration, and control approach influence stable low DO operation and utility outcomes, including aeration energy, external carbon use, and effluent nutrient performance. Aeration energy use will be quantified for each facility in terms of kWh/MG treated and compared to industry average values. RELEVANCE The presentation is relevant to design engineers planning low DO operations at new and existing facilities, aeration retrofits, or control system upgrades; operators managing diurnal and seasonal variability or exploring alternative operating modes; and utility managers evaluating energy reduction strategies, instrumentation, and reduced reliance on external chemicals. Attendees will gain practical insight into aeration system controllability, instrumentation performance requirements, and defining realistic, adaptive operating envelopes based on full-scale experience.
This paper was presented at WEFTEC 2026 in New Orleans, Louisiana.
Presentation time
09:00:00
09:30:00
Session time
8:30:00
10:00:00
SessionDesigning Flexible Aeration Systems for Low Dissolved Oxygen Strategies 
Session locationErnest N. Morial Convention Center
TopicEnergy Production, Conservation, and Management, Facility Operations and Maintenance, Municipal Wastewater Treatment Design, Nutrients
TopicEnergy Production, Conservation, and Management, Facility Operations and Maintenance, Municipal Wastewater Treatment Design, Nutrients
Author(s)
Beach, Natalie, Drescher, Timothy, Hibbard, Craig, Weiland, Thomas, Young, Michelle
Author(s)N. Beach1, T. Drescher2, C. Hibbard3, T. Weiland4, M. Young1
Author affiliation(s)Carollo Engineers, 1Eagle River Water and Sanitation District, 2Boxelder Sanitation District, 3LA County Sanitation District, 4Carollo Engineers, Inc., 1
SourceProceedings of the Water Environment Federation
Document typeConference Paper
PublisherWater Environment Federation
Print publication date Sep 2026
DOI10.2175/193864718825160359
Volume / Issue
Content sourceWEFTEC
Copyright2026
Word count9

Purchase price $11.50

Get access
Log in Purchase content Purchase subscription
You may already have access to this content if you have previously purchased this content or have a subscription.
Need to create an account?

You can purchase access to this content but you might want to consider a subscription for a wide variety of items at a substantial discount!

Purchase access to 'Beyond Setpoints: Three Full-Scale Low DO Case Studies'

Add to cart
Purchase a subscription to gain access to 18,000+ Proceeding Papers, 25+ Fact Sheets, 20+ Technical Reports, 50+ magazine articles and select Technical Publications' chapters.
Loading items
There are no items to display at the moment.
Something went wrong trying to load these items.
Description: Beyond Setpoints: Three Full-Scale Low DO Case Studies
Beyond Setpoints: Three Full-Scale Low DO Case Studies
Pricing
Non-member price: $11.50
Member price:
-10128194
Get access
-10128194
Log in Purchase content Purchase subscription
You may already have access to this content if you have previously purchased this content or have a subscription.
Need to create an account?

You can purchase access to this content but you might want to consider a subscription for a wide variety of items at a substantial discount!

Purchase access to 'Beyond Setpoints: Three Full-Scale Low DO Case Studies'

Add to cart
Purchase a subscription to gain access to 18,000+ Proceeding Papers, 25+ Fact Sheets, 20+ Technical Reports, 50+ magazine articles and select Technical Publications' chapters.

Details

Description: Beyond Setpoints: Three Full-Scale Low DO Case Studies
Beyond Setpoints: Three Full-Scale Low DO Case Studies
Abstract
APPLICABILITY Aeration is the dominant energy consumer in biological nutrient removal systems, and conventional dissolved oxygen (DO) setpoints near 2 mg/L are commonly used to provide operational robustness. Interest in lower DO operation has rapidly increased to address several drivers, including: reduced energy costs, stringent nutrient limits, and optimized carbon addition. Although low DO operation (<1.0 mg/L) has demonstrated biological feasibility, full-scale adoption still faces practical implementation challenges. These include aeration system and control limitations, instrumentation performance at low DO, uncertainty related to sludge settleability, and reduced nitrification kinetics during cold-weather operation. Over the past two decades, low DO operation has progressed from theory and small pilot studies to full-scale demonstration and implementation. However, most recent conference presentations and publications continue to focus on theory, modeling, and kinetics, with limited attention to practical design and retrofit considerations for aeration hardware, instrumentation, and controls. As a result, there is little consolidated guidance on how to support low DO operation across different climates and drivers, including energy reduction, carbon efficiency, and more stringent nutrient limits. The objective of this work is to help address this gap through three full-scale case studies illustrating low DO implementation under real operating conditions. RESULTS AND OUTCOMES This presentation evaluates three full-scale facilities operating with low DO conditions. Two facilities are flow-through activated sludge systems- Avon Wastewater Treatment Facility (Avon) and Pomona Water Reclamation Plant (PWRP)- and one is a phased isolation ditch facility operated by Boxelder Sanitation District (BSD). Together, these facilities represent a range of process configurations, climates, aeration systems, instrumentation, and control approaches. Key facility characteristics are summarized in Table 1. At each facility, DO targets were reduced from typical operating DOs > 1.5 mg/L while maintaining stable performance. At PWRP, average DO was progressively lowered to an average of ~0.7 mg/L under highly diurnal loading conditions. Performance at PWRP reflects a highly instrumented system with multiple DO and ammonia probes, high blower turndown, and a responsive airflow control. Typical airflow control loop performance at PWRP demonstrates how instrumentation quality and airflow responsiveness enabled stable low DO operation under highly variable loading (Figure 1) At Avon, DO concentrations were reduced from ~2.0 mg/L to ~0.7 mg/L in 2025 using PID-based DO setpoint control, with short-term increases during the peak ski season to maintain winter nitrification capacity. Avon is also configured with external carbon addition to meet stringent nutrient limits, and operating data will be compared over the course of DO reduction. Physical system flexibility, including two droplegs per zone and a nested diffuser grid, supported improved air distribution at low airflow rates while maintaining adequate mixing (Figure 2). At BSD, operators reduced bulk DO to approximately 0.3 mg/L through time-based aeration sequencing and extended anoxic periods. All three facilities maintained compliance with effluent requirements during low DO operation. At PWRP, aeration energy was reduced by approximately 57% (Figure 3). At Avon, overall facility energy use decreased by approximately 33% compared to pre-upgrade baselines. At BSD, aeration energy was reduced by approximately 25% relative to 2016 baseline conditions. Using existing operating data and practical experience from full-scale facilities, this presentation will compare equipment selection across the three sites, including aeration hardware, blower configurations, airflow control components (valves and actuators), diffuser layouts, and instrumentation. The advantages and limitations of the different equipment and operational control strategies will also be evaluated. Results will be used to summarize how equipment selection, process configuration, and control approach influence stable low DO operation and utility outcomes, including aeration energy, external carbon use, and effluent nutrient performance. Aeration energy use will be quantified for each facility in terms of kWh/MG treated and compared to industry average values. RELEVANCE The presentation is relevant to design engineers planning low DO operations at new and existing facilities, aeration retrofits, or control system upgrades; operators managing diurnal and seasonal variability or exploring alternative operating modes; and utility managers evaluating energy reduction strategies, instrumentation, and reduced reliance on external chemicals. Attendees will gain practical insight into aeration system controllability, instrumentation performance requirements, and defining realistic, adaptive operating envelopes based on full-scale experience.
This paper was presented at WEFTEC 2026 in New Orleans, Louisiana.
Presentation time
09:00:00
09:30:00
Session time
8:30:00
10:00:00
SessionDesigning Flexible Aeration Systems for Low Dissolved Oxygen Strategies 
Session locationErnest N. Morial Convention Center
TopicEnergy Production, Conservation, and Management, Facility Operations and Maintenance, Municipal Wastewater Treatment Design, Nutrients
TopicEnergy Production, Conservation, and Management, Facility Operations and Maintenance, Municipal Wastewater Treatment Design, Nutrients
Author(s)
Beach, Natalie, Drescher, Timothy, Hibbard, Craig, Weiland, Thomas, Young, Michelle
Author(s)N. Beach1, T. Drescher2, C. Hibbard3, T. Weiland4, M. Young1
Author affiliation(s)Carollo Engineers, 1Eagle River Water and Sanitation District, 2Boxelder Sanitation District, 3LA County Sanitation District, 4Carollo Engineers, Inc., 1
SourceProceedings of the Water Environment Federation
Document typeConference Paper
PublisherWater Environment Federation
Print publication date Sep 2026
DOI10.2175/193864718825160359
Volume / Issue
Content sourceWEFTEC
Copyright2026
Word count9

Actions, changes & tasks

Outstanding Actions

Add action for paragraph

Current Changes

Add signficant change

Current Tasks

Add risk task

Connect with us

Follow us on Facebook
Follow us on Twitter
Connect to us on LinkedIn
Subscribe on YouTube
Powered by Librios Ltd
Powered by Librios Ltd
Authors
Terms of Use
Policies
Help
Accessibility
Contact us
Copyright © 2026 by the Water Environment Federation
Loading items
There are no items to display at the moment.
Something went wrong trying to load these items.
Description: WWTF Digital Boot 180x150
WWTF Digital (180x150)
Created on Jul 02
Websitehttps:/­/­www.wef.org/­wwtf?utm_medium=WWTF&utm_source=AccessWater&utm_campaign=WWTF
180x150
Beach, Natalie. Beyond Setpoints: Three Full-Scale Low DO Case Studies. Water Environment Federation, 2026. Web. 9 Nov. 2026. <https://www.accesswater.org?id=-10128194CITANCHOR>.
Beach, Natalie. Beyond Setpoints: Three Full-Scale Low DO Case Studies. Water Environment Federation, 2026. Accessed November 9, 2026. https://www.accesswater.org/?id=-10128194CITANCHOR.
Beach, Natalie
Beyond Setpoints: Three Full-Scale Low DO Case Studies
Access Water
Water Environment Federation
September 29, 2026
November 9, 2026
https://www.accesswater.org/?id=-10128194CITANCHOR