lastID = -281392
Skip to main content Skip to top navigation Skip to site search
Top of page
  • My citations options
    Web Back (from Web)
    Chicago Back (from Chicago)
    MLA Back (from MLA)
Close action menu

You need to login to use this feature.

Please wait a moment…
Please wait while we update your results...
Please wait a moment...
Description: Access Water
Context Menu
Description: W13-Proceedings
WERF INFR4R12-Sewer Lateral Electro Scan Field Verification Pilot
  • Browse
  • Compilations
    • Compilations list
  • Subscriptions
Tools

Related contents

Loading related content

Workflow

No linked records yet

X
  • Current: 2020-03-31 01:50:18 Adam Phillips
  • 2020-03-31 01:50:13 Adam Phillips
  • 2020-02-01 06:55:03 Administrator
  • 2020-02-01 06:55:02 Administrator
Description: Access Water
  • Browse
  • Compilations
  • Subscriptions
Log in
0
Accessibility Options

Base text size -

This is a sample piece of body text
Larger
Smaller
  • Shopping basket (0)
  • Accessibility options
  • Return to previous
Description: W13-Proceedings
WERF INFR4R12-Sewer Lateral Electro Scan Field Verification Pilot

WERF INFR4R12-Sewer Lateral Electro Scan Field Verification Pilot

WERF INFR4R12-Sewer Lateral Electro Scan Field Verification Pilot

  • New
  • View
  • Details
  • Reader
  • Default
  • Share
  • Email
  • Facebook
  • Twitter
  • LinkedIn
  • New
  • View
  • Default view
  • Reader view
  • Data view
  • Details

This page cannot be printed from here

Please use the dedicated print option from the 'view' drop down menu located in the blue ribbon in the top, right section of the publication.

screenshot of print menu option

Description: W13-Proceedings
WERF INFR4R12-Sewer Lateral Electro Scan Field Verification Pilot
Abstract
WERF selected a proposed research project to field test an emerging technology, called Electro Scan, which finds defects in laterals that potentially allow the infiltration of groundwater into the pipe. Electro Scan testing involves passing an electrical probe through a pipe filled with water. A defect is recorded when electricity, emitted by the probe, can pass through the pipe wall into the surrounding soil to complete an electrical circuit with a ground rod. The significance of the electrical signal suggests the significance of the infiltration defect. Over 100 laterals were tested in the City of Wauwatosa, Wisconsin, with funding by WERF and the Milwaukee Metropolitan Sewerage District (MMSD). These tests were compared to additional lateral tests, including internal television inspection, simulated rainfall infiltration rates, and water exfiltration rates. The paper provides a condensed version of the results. The complete testing results are available from the full WERF report.
WERF selected a proposed research project to field test an emerging technology, called Electro Scan, which finds defects in laterals that potentially allow the infiltration of groundwater into the pipe. Electro Scan testing involves passing an electrical probe through a pipe filled with water. A defect is recorded when electricity, emitted by the probe, can pass through the pipe wall into the...
Author(s)
Andy LukasJerome FlogelJulie McMullinAndrew PlierGary Skipper
SourceProceedings of the Water Environment Federation
Document typeConference Paper
PublisherWater Environment Federation
Print publication date Oct, 2013
ISSN1938-6478
DOI10.2175/193864713813686141
Volume / Issue2013 / 12
Content sourceWEFTEC
Copyright2013
Word count156

Purchase price $11.50

Get access
Log in Purchase content Purchase subscription
You may already have access to this content if you have previously purchased this content or have a subscription.
Need to create an account?

You can purchase access to this content but you might want to consider a subscription for a wide variety of items at a substantial discount!

Purchase access to 'WERF INFR4R12-Sewer Lateral Electro Scan Field Verification Pilot'

Add to cart
Purchase a subscription to gain access to 18,000+ Proceeding Papers, 25+ Fact Sheets, 20+ Technical Reports, 50+ magazine articles and select Technical Publications' chapters.
Loading items
There are no items to display at the moment.
Something went wrong trying to load these items.
Description: W13-Proceedings
WERF INFR4R12-Sewer Lateral Electro Scan Field Verification Pilot
Pricing
Non-member price: $11.50
Member price:
-281392
Get access
-281392
Log in Purchase content Purchase subscription
You may already have access to this content if you have previously purchased this content or have a subscription.
Need to create an account?

You can purchase access to this content but you might want to consider a subscription for a wide variety of items at a substantial discount!

Purchase access to 'WERF INFR4R12-Sewer Lateral Electro Scan Field Verification Pilot'

Add to cart
Purchase a subscription to gain access to 18,000+ Proceeding Papers, 25+ Fact Sheets, 20+ Technical Reports, 50+ magazine articles and select Technical Publications' chapters.

Details

Description: W13-Proceedings
WERF INFR4R12-Sewer Lateral Electro Scan Field Verification Pilot
Abstract
WERF selected a proposed research project to field test an emerging technology, called Electro Scan, which finds defects in laterals that potentially allow the infiltration of groundwater into the pipe. Electro Scan testing involves passing an electrical probe through a pipe filled with water. A defect is recorded when electricity, emitted by the probe, can pass through the pipe wall into the surrounding soil to complete an electrical circuit with a ground rod. The significance of the electrical signal suggests the significance of the infiltration defect. Over 100 laterals were tested in the City of Wauwatosa, Wisconsin, with funding by WERF and the Milwaukee Metropolitan Sewerage District (MMSD). These tests were compared to additional lateral tests, including internal television inspection, simulated rainfall infiltration rates, and water exfiltration rates. The paper provides a condensed version of the results. The complete testing results are available from the full WERF report.
WERF selected a proposed research project to field test an emerging technology, called Electro Scan, which finds defects in laterals that potentially allow the infiltration of groundwater into the pipe. Electro Scan testing involves passing an electrical probe through a pipe filled with water. A defect is recorded when electricity, emitted by the probe, can pass through the pipe wall into the...
Author(s)
Andy LukasJerome FlogelJulie McMullinAndrew PlierGary Skipper
SourceProceedings of the Water Environment Federation
Document typeConference Paper
PublisherWater Environment Federation
Print publication date Oct, 2013
ISSN1938-6478
DOI10.2175/193864713813686141
Volume / Issue2013 / 12
Content sourceWEFTEC
Copyright2013
Word count156

Actions, changes & tasks

Outstanding Actions

Add action for paragraph

Current Changes

Add signficant change

Current Tasks

Add risk task

Connect with us

Follow us on Facebook
Follow us on Twitter
Connect to us on LinkedIn
Subscribe on YouTube
Powered by Librios Ltd
Powered by Librios Ltd
Authors
Terms of Use
Policies
Help
Accessibility
Contact us
Copyright © 2024 by the Water Environment Federation
Loading items
There are no items to display at the moment.
Something went wrong trying to load these items.
Description: WWTF Digital Boot 180x150
WWTF Digital (180x150)
Created on Jul 02
Websitehttps:/­/­www.wef.org/­wwtf?utm_medium=WWTF&utm_source=AccessWater&utm_campaign=WWTF
180x150
Andy Lukas# Jerome Flogel# Julie McMullin# Andrew Plier# Gary Skipper. WERF INFR4R12-Sewer Lateral Electro Scan Field Verification Pilot. Alexandria, VA 22314-1994, USA: Water Environment Federation, 2018. Web. 12 Sep. 2025. <https://www.accesswater.org?id=-281392CITANCHOR>.
Andy Lukas# Jerome Flogel# Julie McMullin# Andrew Plier# Gary Skipper. WERF INFR4R12-Sewer Lateral Electro Scan Field Verification Pilot. Alexandria, VA 22314-1994, USA: Water Environment Federation, 2018. Accessed September 12, 2025. https://www.accesswater.org/?id=-281392CITANCHOR.
Andy Lukas# Jerome Flogel# Julie McMullin# Andrew Plier# Gary Skipper
WERF INFR4R12-Sewer Lateral Electro Scan Field Verification Pilot
Access Water
Water Environment Federation
December 22, 2018
September 12, 2025
https://www.accesswater.org/?id=-281392CITANCHOR