lastID = -288612
Skip to main content Skip to top navigation Skip to site search
Top of page
  • My citations options
    Web Back (from Web)
    Chicago Back (from Chicago)
    MLA Back (from MLA)
Close action menu

You need to login to use this feature.

Please wait a moment…
Please wait while we update your results...
Please wait a moment...
Description: Access Water
Context Menu
Description: Book cover
OPERATION AND PERFORMANCE OF A HIGH RATE AUTO-HEATED AEROBIC DIGESTE
  • Browse
  • Compilations
    • Compilations list
  • Subscriptions
Tools

Related contents

Loading related content

Workflow

No linked records yet

X
  • Current: 2022-05-04 19:58:53 Adam Phillips
  • 2022-05-04 19:58:52 Adam Phillips
  • 2020-02-01 02:23:03 Administrator
  • 2020-02-01 02:23:02 Administrator
  • 2020-02-01 02:23:01 Administrator
Description: Access Water
  • Browse
  • Compilations
  • Subscriptions
Log in
0
Accessibility Options

Base text size -

This is a sample piece of body text
Larger
Smaller
  • Shopping basket (0)
  • Accessibility options
  • Return to previous
Description: Book cover
OPERATION AND PERFORMANCE OF A HIGH RATE AUTO-HEATED AEROBIC DIGESTE

OPERATION AND PERFORMANCE OF A HIGH RATE AUTO-HEATED AEROBIC DIGESTE

OPERATION AND PERFORMANCE OF A HIGH RATE AUTO-HEATED AEROBIC DIGESTE

  • New
  • View
  • Details
  • Reader
  • Default
  • Share
  • Email
  • Facebook
  • Twitter
  • LinkedIn
  • New
  • View
  • Default view
  • Reader view
  • Data view
  • Details

This page cannot be printed from here

Please use the dedicated print option from the 'view' drop down menu located in the blue ribbon in the top, right section of the publication.

screenshot of print menu option

Description: Book cover
OPERATION AND PERFORMANCE OF A HIGH RATE AUTO-HEATED AEROBIC DIGESTE
Abstract
The Village of Plover, Wisconsin, operates an oxidation ditch activated sludge system for treating wastewater generated within the Village's sewer service area. The Village recently constructed a high rate auto-heated aerobic digester for stabilizing waste activated sludge. Digested sludge is belt pressed prior to land application.The need to reliably and safely dispose of biosolids, together with increased public awareness, resulted in the need to improve sludge quality for land application. The high rate auto-heated aerobic digester was constructed to achieve compliance with the vector attraction reduction requirements prior to the biosolids leaving the treatment plant site. The Village did not want to rely on incorporation of biosolids to achieve vector attraction reduction.Pre-thickening of waste activated sludge ahead of the aerobic digester, together with efficient fine pore aeration, results into auto-heating of the digester to temperatures up to 49 °C (120 °F). High operating temperatures in the digesters increases the rate of digestion and results in high volatile solids reduction and high pathogen reductions. Volatile solids reduction over the first year of operation has consistently been above the 38 % volatile solids reduction required to achieve vector attraction reduction. Historically, achieving 38 % volatile solids reduction for extended aeration activated sludge has been difficult to achieve using aerobic digestion technology. Fecal coliform densities have also been reduced to near Class A levels.High temperature aerobic digestion processes have frequently experienced a variety of operational challenges, including generation of odors, limitations in oxygen delivery, high recycle loadings, foaming, and poor dewaterability of the digested sludge. The Plover aerobic digester experienced many of these issues during the first year of operation. Each of these challenges was addressed by implementing operational changes, resulting in a process that produced a stable biosolids product without the associated operational issues.Many of these challenges were addresses by reducing operating temperature in the digesters. This resulted in improved belt press solids capture lower polymer demand and reduction in odors.This paper will present the operational challenges presented by the high rate auto-heated aerobic digester and discuss the operational changes considered to address these issues including the effects on performance of the system.
The Village of Plover, Wisconsin, operates an oxidation ditch activated sludge system for treating wastewater generated within the Village's sewer service area. The Village recently constructed a high rate auto-heated aerobic digester for stabilizing waste activated sludge. Digested sludge is belt pressed prior to land application.The need to reliably and safely dispose of biosolids, together with...
Author(s)
Steve ArantRich Boden
SourceProceedings of the Water Environment Federation
SubjectSession 81 - Residuals and Biosolids Management Symposium: Operations and Maintenance
Document typeConference Paper
PublisherWater Environment Federation
Print publication date Jan, 2001
ISSN1938-6478
SICI1938-6478(20010101)2001:8L.18;1-
DOI10.2175/193864701790861730
Volume / Issue2001 / 8
Content sourceWEFTEC
First / last page(s)18 - 30
Copyright2001
Word count362

Purchase price $11.50

Get access
Log in Purchase content Purchase subscription
You may already have access to this content if you have previously purchased this content or have a subscription.
Need to create an account?

You can purchase access to this content but you might want to consider a subscription for a wide variety of items at a substantial discount!

Purchase access to 'OPERATION AND PERFORMANCE OF A HIGH RATE AUTO-HEATED AEROBIC DIGESTE'

Add to cart
Purchase a subscription to gain access to 18,000+ Proceeding Papers, 25+ Fact Sheets, 20+ Technical Reports, 50+ magazine articles and select Technical Publications' chapters.
Loading items
There are no items to display at the moment.
Something went wrong trying to load these items.
Description: Book cover
OPERATION AND PERFORMANCE OF A HIGH RATE AUTO-HEATED AEROBIC DIGESTE
Pricing
Non-member price: $11.50
Member price:
-288612
Get access
-288612
Log in Purchase content Purchase subscription
You may already have access to this content if you have previously purchased this content or have a subscription.
Need to create an account?

You can purchase access to this content but you might want to consider a subscription for a wide variety of items at a substantial discount!

Purchase access to 'OPERATION AND PERFORMANCE OF A HIGH RATE AUTO-HEATED AEROBIC DIGESTE'

Add to cart
Purchase a subscription to gain access to 18,000+ Proceeding Papers, 25+ Fact Sheets, 20+ Technical Reports, 50+ magazine articles and select Technical Publications' chapters.

Details

Description: Book cover
OPERATION AND PERFORMANCE OF A HIGH RATE AUTO-HEATED AEROBIC DIGESTE
Abstract
The Village of Plover, Wisconsin, operates an oxidation ditch activated sludge system for treating wastewater generated within the Village's sewer service area. The Village recently constructed a high rate auto-heated aerobic digester for stabilizing waste activated sludge. Digested sludge is belt pressed prior to land application.The need to reliably and safely dispose of biosolids, together with increased public awareness, resulted in the need to improve sludge quality for land application. The high rate auto-heated aerobic digester was constructed to achieve compliance with the vector attraction reduction requirements prior to the biosolids leaving the treatment plant site. The Village did not want to rely on incorporation of biosolids to achieve vector attraction reduction.Pre-thickening of waste activated sludge ahead of the aerobic digester, together with efficient fine pore aeration, results into auto-heating of the digester to temperatures up to 49 °C (120 °F). High operating temperatures in the digesters increases the rate of digestion and results in high volatile solids reduction and high pathogen reductions. Volatile solids reduction over the first year of operation has consistently been above the 38 % volatile solids reduction required to achieve vector attraction reduction. Historically, achieving 38 % volatile solids reduction for extended aeration activated sludge has been difficult to achieve using aerobic digestion technology. Fecal coliform densities have also been reduced to near Class A levels.High temperature aerobic digestion processes have frequently experienced a variety of operational challenges, including generation of odors, limitations in oxygen delivery, high recycle loadings, foaming, and poor dewaterability of the digested sludge. The Plover aerobic digester experienced many of these issues during the first year of operation. Each of these challenges was addressed by implementing operational changes, resulting in a process that produced a stable biosolids product without the associated operational issues.Many of these challenges were addresses by reducing operating temperature in the digesters. This resulted in improved belt press solids capture lower polymer demand and reduction in odors.This paper will present the operational challenges presented by the high rate auto-heated aerobic digester and discuss the operational changes considered to address these issues including the effects on performance of the system.
The Village of Plover, Wisconsin, operates an oxidation ditch activated sludge system for treating wastewater generated within the Village's sewer service area. The Village recently constructed a high rate auto-heated aerobic digester for stabilizing waste activated sludge. Digested sludge is belt pressed prior to land application.The need to reliably and safely dispose of biosolids, together with...
Author(s)
Steve ArantRich Boden
SourceProceedings of the Water Environment Federation
SubjectSession 81 - Residuals and Biosolids Management Symposium: Operations and Maintenance
Document typeConference Paper
PublisherWater Environment Federation
Print publication date Jan, 2001
ISSN1938-6478
SICI1938-6478(20010101)2001:8L.18;1-
DOI10.2175/193864701790861730
Volume / Issue2001 / 8
Content sourceWEFTEC
First / last page(s)18 - 30
Copyright2001
Word count362

Actions, changes & tasks

Outstanding Actions

Add action for paragraph

Current Changes

Add signficant change

Current Tasks

Add risk task

Connect with us

Follow us on Facebook
Follow us on Twitter
Connect to us on LinkedIn
Subscribe on YouTube
Powered by Librios Ltd
Powered by Librios Ltd
Authors
Terms of Use
Policies
Help
Accessibility
Contact us
Copyright © 2024 by the Water Environment Federation
Loading items
There are no items to display at the moment.
Something went wrong trying to load these items.
Description: WWTF Digital Boot 180x150
WWTF Digital (180x150)
Created on Jul 02
Websitehttps:/­/­www.wef.org/­wwtf?utm_medium=WWTF&utm_source=AccessWater&utm_campaign=WWTF
180x150
Steve Arant# Rich Boden. OPERATION AND PERFORMANCE OF A HIGH RATE AUTO-HEATED AEROBIC DIGESTE. Alexandria, VA 22314-1994, USA: Water Environment Federation, 2018. Web. 8 Jun. 2025. <https://www.accesswater.org?id=-288612CITANCHOR>.
Steve Arant# Rich Boden. OPERATION AND PERFORMANCE OF A HIGH RATE AUTO-HEATED AEROBIC DIGESTE. Alexandria, VA 22314-1994, USA: Water Environment Federation, 2018. Accessed June 8, 2025. https://www.accesswater.org/?id=-288612CITANCHOR.
Steve Arant# Rich Boden
OPERATION AND PERFORMANCE OF A HIGH RATE AUTO-HEATED AEROBIC DIGESTE
Access Water
Water Environment Federation
December 22, 2018
June 8, 2025
https://www.accesswater.org/?id=-288612CITANCHOR