lastID = -290996
Skip to main content Skip to top navigation Skip to site search
Top of page
  • My citations options
    Web Back (from Web)
    Chicago Back (from Chicago)
    MLA Back (from MLA)
Close action menu

You need to login to use this feature.

Please wait a moment…
Please wait while we update your results...
Please wait a moment...
Description: Access Water
Context Menu
Description: Book cover
MATERIALS: 7,000, LABOR: 9,000; SLUDGE BULKING CONTROL: PRICELESS
  • Browse
  • Compilations
    • Compilations list
  • Subscriptions
Tools

Related contents

Loading related content

Workflow

No linked records yet

X
  • Current: 2020-02-01 01:18:45 Administrator
  • 2020-02-01 01:18:44 Administrator
  • 2020-02-01 01:18:43 Administrator
Description: Access Water
  • Browse
  • Compilations
  • Subscriptions
Log in
0
Accessibility Options

Base text size -

This is a sample piece of body text
Larger
Smaller
  • Shopping basket (0)
  • Accessibility options
  • Return to previous
Description: Book cover
MATERIALS: 7,000, LABOR: 9,000; SLUDGE BULKING CONTROL: PRICELESS

MATERIALS: 7,000, LABOR: 9,000; SLUDGE BULKING CONTROL: PRICELESS

MATERIALS: 7,000, LABOR: 9,000; SLUDGE BULKING CONTROL: PRICELESS

  • New
  • View
  • Details
  • Reader
  • Default
  • Share
  • Email
  • Facebook
  • Twitter
  • LinkedIn
  • New
  • View
  • Default view
  • Reader view
  • Data view
  • Details

This page cannot be printed from here

Please use the dedicated print option from the 'view' drop down menu located in the blue ribbon in the top, right section of the publication.

screenshot of print menu option

Description: Book cover
MATERIALS: 7,000, LABOR: 9,000; SLUDGE BULKING CONTROL: PRICELESS
Abstract
The City of Billings Montana Wastewater Treatment Plant (WWTP) is a 26 million gallon per day (MGD) activated sludge process with current average flows around 16 MGD. The plant has had a historic filamentous sludge bulking problem that in recent years necessitated chlorinating return activated sludge (RAS) to keep the sludge volume index (SVI) under control.The aeration basin configuration, shown in Figure 1, included a selector (Zone 1) which would act either anoxic or anaerobic depending on whether the plant was nitrifying or not. The selector was not effective. Zone 1 is mixed with a vertical turbine mixer. In an attempt to better control filamentous bulking and improve sludge thickening properties it was decided to experiment with an additional anaerobic selector at full scale in one of the aeration basin treatment trains.Converting Zone 2A to an anaerobic reactor, in addition to Zone 1, resulted in an average two zone selector HRT (hydraulic retention time) of 37 minutes with two secondary treatment trains operating. To cost effectively convert Zone 2A to an anaerobic reactor plant, staff constructed the modifications using nonpermanent materials. A summary of the conversion to an anaerobic selector mode included:An aluminum plate to block off one overflow weir in the existing Zone 1 concrete baffle wallAluminum plates to block off submerged openings in the Zone 2A baffle wallsWood baffle walls attached to the walls and the old mechanical aerator supports to promote plug flow in the Zone 2ARemoval of fine bubble diffusers in Zone 2A to facilitate using low air flow for mixingAdding membranes to spare diffusers in Zone 2B to handle the higher anticipated loadings in that zone.Air piping modifications to enable the diffuser grid changes.The initial operation of the anaerobic selector was somewhat successful with two aeration basin treatment trains operating. However, when a third aeration basin treatment train was added to experiment increasing the HRT, the SVI measurements increased to the 500-600 range. The theory was that the air being added in Zone 2A for mixing, while reduced to a minimum, was still too high and was resulting in localized aerated zones. To diminish this potential effect the operators decreased the air flow to Zone 2A incrementally while visually checking to see if the solids were staying in suspension. Eventually the air was shut-off completely with no detrimental effects.With the Zone 2A air shut off, the SVIs began to decrease and phosphorous release in the selector and uptake in the aeration basin increased. Since the air was shut off, no chlorine has been used for filamentous bulking control in the aeration basin treatment train with the new selector and SVIs have consistently been around 150-200.The project success was not only measured by decreased filamentous sludge bulking and improved sludge thickening, but also by the cost effective construction which was approximately 7,000 in materials and 9,000 in labor.
The City of Billings Montana Wastewater Treatment Plant (WWTP) is a 26 million gallon per day (MGD) activated sludge process with current average flows around 16 MGD. The plant has had a historic filamentous sludge bulking problem that in recent years necessitated chlorinating return activated sludge (RAS) to keep the sludge volume index (SVI) under control.The aeration basin configuration, shown...
Author(s)
C. HabbenS. StanleyB. Bower
SourceProceedings of the Water Environment Federation
SubjectSession 16: Process Operations
Document typeConference Paper
PublisherWater Environment Federation
Print publication date Jan, 2004
ISSN1938-6478
SICI1938-6478(20040101)2004:15L.363;1-
DOI10.2175/193864704784148204
Volume / Issue2004 / 15
Content sourceWEFTEC
First / last page(s)363 - 371
Copyright2004
Word count487

Purchase price $11.50

Get access
Log in Purchase content Purchase subscription
You may already have access to this content if you have previously purchased this content or have a subscription.
Need to create an account?

You can purchase access to this content but you might want to consider a subscription for a wide variety of items at a substantial discount!

Purchase access to 'MATERIALS: 7,000, LABOR: 9,000; SLUDGE BULKING CONTROL: PRICELESS'

Add to cart
Purchase a subscription to gain access to 18,000+ Proceeding Papers, 25+ Fact Sheets, 20+ Technical Reports, 50+ magazine articles and select Technical Publications' chapters.
Loading items
There are no items to display at the moment.
Something went wrong trying to load these items.
Description: Book cover
MATERIALS: 7,000, LABOR: 9,000; SLUDGE BULKING CONTROL: PRICELESS
Pricing
Non-member price: $11.50
Member price:
-290996
Get access
-290996
Log in Purchase content Purchase subscription
You may already have access to this content if you have previously purchased this content or have a subscription.
Need to create an account?

You can purchase access to this content but you might want to consider a subscription for a wide variety of items at a substantial discount!

Purchase access to 'MATERIALS: 7,000, LABOR: 9,000; SLUDGE BULKING CONTROL: PRICELESS'

Add to cart
Purchase a subscription to gain access to 18,000+ Proceeding Papers, 25+ Fact Sheets, 20+ Technical Reports, 50+ magazine articles and select Technical Publications' chapters.

Details

Description: Book cover
MATERIALS: 7,000, LABOR: 9,000; SLUDGE BULKING CONTROL: PRICELESS
Abstract
The City of Billings Montana Wastewater Treatment Plant (WWTP) is a 26 million gallon per day (MGD) activated sludge process with current average flows around 16 MGD. The plant has had a historic filamentous sludge bulking problem that in recent years necessitated chlorinating return activated sludge (RAS) to keep the sludge volume index (SVI) under control.The aeration basin configuration, shown in Figure 1, included a selector (Zone 1) which would act either anoxic or anaerobic depending on whether the plant was nitrifying or not. The selector was not effective. Zone 1 is mixed with a vertical turbine mixer. In an attempt to better control filamentous bulking and improve sludge thickening properties it was decided to experiment with an additional anaerobic selector at full scale in one of the aeration basin treatment trains.Converting Zone 2A to an anaerobic reactor, in addition to Zone 1, resulted in an average two zone selector HRT (hydraulic retention time) of 37 minutes with two secondary treatment trains operating. To cost effectively convert Zone 2A to an anaerobic reactor plant, staff constructed the modifications using nonpermanent materials. A summary of the conversion to an anaerobic selector mode included:An aluminum plate to block off one overflow weir in the existing Zone 1 concrete baffle wallAluminum plates to block off submerged openings in the Zone 2A baffle wallsWood baffle walls attached to the walls and the old mechanical aerator supports to promote plug flow in the Zone 2ARemoval of fine bubble diffusers in Zone 2A to facilitate using low air flow for mixingAdding membranes to spare diffusers in Zone 2B to handle the higher anticipated loadings in that zone.Air piping modifications to enable the diffuser grid changes.The initial operation of the anaerobic selector was somewhat successful with two aeration basin treatment trains operating. However, when a third aeration basin treatment train was added to experiment increasing the HRT, the SVI measurements increased to the 500-600 range. The theory was that the air being added in Zone 2A for mixing, while reduced to a minimum, was still too high and was resulting in localized aerated zones. To diminish this potential effect the operators decreased the air flow to Zone 2A incrementally while visually checking to see if the solids were staying in suspension. Eventually the air was shut-off completely with no detrimental effects.With the Zone 2A air shut off, the SVIs began to decrease and phosphorous release in the selector and uptake in the aeration basin increased. Since the air was shut off, no chlorine has been used for filamentous bulking control in the aeration basin treatment train with the new selector and SVIs have consistently been around 150-200.The project success was not only measured by decreased filamentous sludge bulking and improved sludge thickening, but also by the cost effective construction which was approximately 7,000 in materials and 9,000 in labor.
The City of Billings Montana Wastewater Treatment Plant (WWTP) is a 26 million gallon per day (MGD) activated sludge process with current average flows around 16 MGD. The plant has had a historic filamentous sludge bulking problem that in recent years necessitated chlorinating return activated sludge (RAS) to keep the sludge volume index (SVI) under control.The aeration basin configuration, shown...
Author(s)
C. HabbenS. StanleyB. Bower
SourceProceedings of the Water Environment Federation
SubjectSession 16: Process Operations
Document typeConference Paper
PublisherWater Environment Federation
Print publication date Jan, 2004
ISSN1938-6478
SICI1938-6478(20040101)2004:15L.363;1-
DOI10.2175/193864704784148204
Volume / Issue2004 / 15
Content sourceWEFTEC
First / last page(s)363 - 371
Copyright2004
Word count487

Actions, changes & tasks

Outstanding Actions

Add action for paragraph

Current Changes

Add signficant change

Current Tasks

Add risk task

Connect with us

Follow us on Facebook
Follow us on Twitter
Connect to us on LinkedIn
Subscribe on YouTube
Powered by Librios Ltd
Powered by Librios Ltd
Authors
Terms of Use
Policies
Help
Accessibility
Contact us
Copyright © 2024 by the Water Environment Federation
Loading items
There are no items to display at the moment.
Something went wrong trying to load these items.
Description: WWTF Digital Boot 180x150
WWTF Digital (180x150)
Created on Jul 02
Websitehttps:/­/­www.wef.org/­wwtf?utm_medium=WWTF&utm_source=AccessWater&utm_campaign=WWTF
180x150
C. Habben# S. Stanley# B. Bower. MATERIALS: 7,000, LABOR: 9,000; SLUDGE BULKING CONTROL: PRICELESS. Alexandria, VA 22314-1994, USA: Water Environment Federation, 2018. Web. 4 Jul. 2025. <https://www.accesswater.org?id=-290996CITANCHOR>.
C. Habben# S. Stanley# B. Bower. MATERIALS: 7,000, LABOR: 9,000; SLUDGE BULKING CONTROL: PRICELESS. Alexandria, VA 22314-1994, USA: Water Environment Federation, 2018. Accessed July 4, 2025. https://www.accesswater.org/?id=-290996CITANCHOR.
C. Habben# S. Stanley# B. Bower
MATERIALS: 7,000, LABOR: 9,000; SLUDGE BULKING CONTROL: PRICELESS
Access Water
Water Environment Federation
December 22, 2018
July 4, 2025