lastID = -293632
Skip to main content Skip to top navigation Skip to site search
Top of page
  • My citations options
    Web Back (from Web)
    Chicago Back (from Chicago)
    MLA Back (from MLA)
Close action menu

You need to login to use this feature.

Please wait a moment…
Please wait while we update your results...
Please wait a moment...
Description: Access Water
Context Menu
Description: Book cover
Tennessee Valley Marina and Campground Wastewater Characterization Screening Study Follow-Up Report
  • Browse
  • Compilations
    • Compilations list
  • Subscriptions
Tools

Related contents

Loading related content

Workflow

No linked records yet

X
  • Current: 2020-02-01 04:51:21 Administrator
  • 2020-02-01 04:51:20 Administrator
Description: Access Water
  • Browse
  • Compilations
  • Subscriptions
Log in
0
Accessibility Options

Base text size -

This is a sample piece of body text
Larger
Smaller
  • Shopping basket (0)
  • Accessibility options
  • Return to previous
Description: Book cover
Tennessee Valley Marina and Campground Wastewater Characterization Screening Study Follow-Up Report

Tennessee Valley Marina and Campground Wastewater Characterization Screening Study Follow-Up Report

Tennessee Valley Marina and Campground Wastewater Characterization Screening Study Follow-Up Report

  • New
  • View
  • Details
  • Reader
  • Default
  • Share
  • Email
  • Facebook
  • Twitter
  • LinkedIn
  • New
  • View
  • Default view
  • Reader view
  • Data view
  • Details

This page cannot be printed from here

Please use the dedicated print option from the 'view' drop down menu located in the blue ribbon in the top, right section of the publication.

screenshot of print menu option

Description: Book cover
Tennessee Valley Marina and Campground Wastewater Characterization Screening Study Follow-Up Report
Abstract
This completed study, funded by Tennessee Valley Authority (TVA), is a follow-up to the 2003 TVA Project Report, "Tennessee Valley Marina and Campground Wastewater Characterization Screening Study" (Matassa 2003) which was presented at WEFTEC 2005. The 2003 report concluded that marina and campground pump-out wastewaters were highly concentrated in comparison to traditional residential wastewater. Concerns over whether marina and campground onsite/decentralized wastewater systems (DWS) adequately treat wastewaters led to this follow-up study which examined treated effluent below three drainfields. Several water quality parameters were collected and analyzed including toxicity, pH, nutrients, and biochemical and chemical oxygen demand.Three sites (one marina and two campgrounds) from the original fourteen studied and characterized in 2003 were investigated. Site selection considerations included strength of wastewater, mix of campgrounds and marinas, and including DWS designs based both on current and older DWS state regulations. Site characteristics are shown in Table 1.In order to determine the level of treatment accomplished by campground and marina onsite/decentralized wastewater treatment systems (DWS), pressure-vacuum soil water samplers were used to collect samples below drainfield trenches. Nine samplers were placed in each DWS drainfield. Samplers were placed in groups of three at the head (closest to septic tank inflow), middle, and end of the drainfield (farthest distance from septic tank inflow) approximately two feet down slope from the centerline of each trench. Samplers were spaced about three feet apart as shown in Figure 1. The bottom of the ceramic cup was installed to collect treated wastewater from approximately two feet below the bottom of the drain field trenches.Four sampling events were conducted at each marina or campground from September 2005 through July 2006. There was an emphasis on sampling during the non-peak (resting) season (1 sample), during peak season, around the Independence Day holiday (1 sample), and near the end of summer (2 samples).Samples were collected, analyzed, and compared to 2003 septic tank effluent samples. Also, facility treatment effectiveness, seasonal trends, and sample concentrations along the length of the trench were investigated. Table 2 presents minimum and maximum sample values below the drainfield trenches and percent difference from septic tank effluent sample.Nutrients (except for nitrate-nitrite as N), COD, and BOD5 had removal rates from 83 to 98% when compared to 2003 septic tank effluent. Nitrate-nitrite increased below the drainfield trenches compared to the septic tank effluent samples because of the expected conversion of oxidation of ammonia to nitrate. Toxicity of the treated effluent, as indicated by Microtox values, was greatly reduced as well.Facilities designed to current state standards provided the highest level of treatment. Older facilities receiving pumpout wastes which are located near sensitive areas should be evaluated for impacts and potential upgrades.To show the differing levels of treatment between Facility A (newer) and Facility C (50+ years old) the ammonia and BOD5 values are compared in Figure 2. This figure shows significantly lower concentrations of both BOD and ammonia at Facility A compared to those at Facility C at all locations in the drainfields. The data from Facility B (designed to current state standards) implies an even higher level of treatment.Other trends including seasonal variations and sample concentrations along the length of the trench were examined. Most marinas and campgrounds are closed during winter months. As a result, seasonal variations in wastewater concentrations were expected. Surprisingly, no strong association was apparent.Along the trench length, trends were observed in sample volume and wastewater concentrations. Both were generally greater toward the head of each system. For example, At Facility A, a serial distribution system, wastewater effluent was apparently dispersed throughout the field, as evidenced by the proliferation of samples (compared to Facility C). Nutrient concentrations, except for Nitrate-Nitrite N, and COD and BOD5 concentrations generally decrease from the head to the end of the field. This could be explained by more saturated conditions at the head of each system accompanied by biomat build-up.Overall, findings indicated that all three DWS studied seem to provide a significant and high level of treatment despite heavy loadings associated with marina and campground pump-out wastes, when compared to the 2003 septic tank effluent samples.
This completed study, funded by Tennessee Valley Authority (TVA), is a follow-up to the 2003 TVA Project Report, "Tennessee Valley Marina and Campground Wastewater Characterization Screening Study" (Matassa 2003) which was presented at WEFTEC 2005. The 2003 report concluded that marina and campground pump-out wastewaters were highly concentrated in comparison to traditional residential wastewater....
Author(s)
Jennifer N. BrogdonCharles L. McEntyreJonathan H. WalkerA. Chevales Williams
SourceProceedings of the Water Environment Federation
SubjectSession 98: Small and Decentralized Systems
Document typeConference Paper
PublisherWater Environment Federation
Print publication date Oct, 2007
ISSN1938-6478
SICI1938-6478(20071001)2007:10L.7823;1-
DOI10.2175/193864707787168800
Volume / Issue2007 / 10
Content sourceWEFTEC
First / last page(s)7823 - 7837
Copyright2007
Word count690
Subject keywordsDECENTRALIZEDCAMPGROUNDMARINADRAINFIELD

Purchase price $11.50

Get access
Log in Purchase content Purchase subscription
You may already have access to this content if you have previously purchased this content or have a subscription.
Need to create an account?

You can purchase access to this content but you might want to consider a subscription for a wide variety of items at a substantial discount!

Purchase access to 'Tennessee Valley Marina and Campground Wastewater Characterization Screening Study Follow-Up Report'

Add to cart
Purchase a subscription to gain access to 18,000+ Proceeding Papers, 25+ Fact Sheets, 20+ Technical Reports, 50+ magazine articles and select Technical Publications' chapters.
Loading items
There are no items to display at the moment.
Something went wrong trying to load these items.
Description: Book cover
Tennessee Valley Marina and Campground Wastewater Characterization Screening Study Follow-Up Report
Pricing
Non-member price: $11.50
Member price:
-293632
Get access
-293632
Log in Purchase content Purchase subscription
You may already have access to this content if you have previously purchased this content or have a subscription.
Need to create an account?

You can purchase access to this content but you might want to consider a subscription for a wide variety of items at a substantial discount!

Purchase access to 'Tennessee Valley Marina and Campground Wastewater Characterization Screening Study Follow-Up Report'

Add to cart
Purchase a subscription to gain access to 18,000+ Proceeding Papers, 25+ Fact Sheets, 20+ Technical Reports, 50+ magazine articles and select Technical Publications' chapters.

Details

Description: Book cover
Tennessee Valley Marina and Campground Wastewater Characterization Screening Study Follow-Up Report
Abstract
This completed study, funded by Tennessee Valley Authority (TVA), is a follow-up to the 2003 TVA Project Report, "Tennessee Valley Marina and Campground Wastewater Characterization Screening Study" (Matassa 2003) which was presented at WEFTEC 2005. The 2003 report concluded that marina and campground pump-out wastewaters were highly concentrated in comparison to traditional residential wastewater. Concerns over whether marina and campground onsite/decentralized wastewater systems (DWS) adequately treat wastewaters led to this follow-up study which examined treated effluent below three drainfields. Several water quality parameters were collected and analyzed including toxicity, pH, nutrients, and biochemical and chemical oxygen demand.Three sites (one marina and two campgrounds) from the original fourteen studied and characterized in 2003 were investigated. Site selection considerations included strength of wastewater, mix of campgrounds and marinas, and including DWS designs based both on current and older DWS state regulations. Site characteristics are shown in Table 1.In order to determine the level of treatment accomplished by campground and marina onsite/decentralized wastewater treatment systems (DWS), pressure-vacuum soil water samplers were used to collect samples below drainfield trenches. Nine samplers were placed in each DWS drainfield. Samplers were placed in groups of three at the head (closest to septic tank inflow), middle, and end of the drainfield (farthest distance from septic tank inflow) approximately two feet down slope from the centerline of each trench. Samplers were spaced about three feet apart as shown in Figure 1. The bottom of the ceramic cup was installed to collect treated wastewater from approximately two feet below the bottom of the drain field trenches.Four sampling events were conducted at each marina or campground from September 2005 through July 2006. There was an emphasis on sampling during the non-peak (resting) season (1 sample), during peak season, around the Independence Day holiday (1 sample), and near the end of summer (2 samples).Samples were collected, analyzed, and compared to 2003 septic tank effluent samples. Also, facility treatment effectiveness, seasonal trends, and sample concentrations along the length of the trench were investigated. Table 2 presents minimum and maximum sample values below the drainfield trenches and percent difference from septic tank effluent sample.Nutrients (except for nitrate-nitrite as N), COD, and BOD5 had removal rates from 83 to 98% when compared to 2003 septic tank effluent. Nitrate-nitrite increased below the drainfield trenches compared to the septic tank effluent samples because of the expected conversion of oxidation of ammonia to nitrate. Toxicity of the treated effluent, as indicated by Microtox values, was greatly reduced as well.Facilities designed to current state standards provided the highest level of treatment. Older facilities receiving pumpout wastes which are located near sensitive areas should be evaluated for impacts and potential upgrades.To show the differing levels of treatment between Facility A (newer) and Facility C (50+ years old) the ammonia and BOD5 values are compared in Figure 2. This figure shows significantly lower concentrations of both BOD and ammonia at Facility A compared to those at Facility C at all locations in the drainfields. The data from Facility B (designed to current state standards) implies an even higher level of treatment.Other trends including seasonal variations and sample concentrations along the length of the trench were examined. Most marinas and campgrounds are closed during winter months. As a result, seasonal variations in wastewater concentrations were expected. Surprisingly, no strong association was apparent.Along the trench length, trends were observed in sample volume and wastewater concentrations. Both were generally greater toward the head of each system. For example, At Facility A, a serial distribution system, wastewater effluent was apparently dispersed throughout the field, as evidenced by the proliferation of samples (compared to Facility C). Nutrient concentrations, except for Nitrate-Nitrite N, and COD and BOD5 concentrations generally decrease from the head to the end of the field. This could be explained by more saturated conditions at the head of each system accompanied by biomat build-up.Overall, findings indicated that all three DWS studied seem to provide a significant and high level of treatment despite heavy loadings associated with marina and campground pump-out wastes, when compared to the 2003 septic tank effluent samples.
This completed study, funded by Tennessee Valley Authority (TVA), is a follow-up to the 2003 TVA Project Report, "Tennessee Valley Marina and Campground Wastewater Characterization Screening Study" (Matassa 2003) which was presented at WEFTEC 2005. The 2003 report concluded that marina and campground pump-out wastewaters were highly concentrated in comparison to traditional residential wastewater....
Author(s)
Jennifer N. BrogdonCharles L. McEntyreJonathan H. WalkerA. Chevales Williams
SourceProceedings of the Water Environment Federation
SubjectSession 98: Small and Decentralized Systems
Document typeConference Paper
PublisherWater Environment Federation
Print publication date Oct, 2007
ISSN1938-6478
SICI1938-6478(20071001)2007:10L.7823;1-
DOI10.2175/193864707787168800
Volume / Issue2007 / 10
Content sourceWEFTEC
First / last page(s)7823 - 7837
Copyright2007
Word count690
Subject keywordsDECENTRALIZEDCAMPGROUNDMARINADRAINFIELD

Actions, changes & tasks

Outstanding Actions

Add action for paragraph

Current Changes

Add signficant change

Current Tasks

Add risk task

Connect with us

Follow us on Facebook
Follow us on Twitter
Connect to us on LinkedIn
Subscribe on YouTube
Powered by Librios Ltd
Powered by Librios Ltd
Authors
Terms of Use
Policies
Help
Accessibility
Contact us
Copyright © 2024 by the Water Environment Federation
Loading items
There are no items to display at the moment.
Something went wrong trying to load these items.
Description: WWTF Digital Boot 180x150
WWTF Digital (180x150)
Created on Jul 02
Websitehttps:/­/­www.wef.org/­wwtf?utm_medium=WWTF&utm_source=AccessWater&utm_campaign=WWTF
180x150
Jennifer N. Brogdon# Charles L. McEntyre# Jonathan H. Walker# A. Chevales Williams. Tennessee Valley Marina and Campground Wastewater Characterization Screening Study Follow-Up Report. Water Environment Federation, 2018. Web. 10 Jun. 2025. <https://www.accesswater.org?id=-293632CITANCHOR>.
Jennifer N. Brogdon# Charles L. McEntyre# Jonathan H. Walker# A. Chevales Williams. Tennessee Valley Marina and Campground Wastewater Characterization Screening Study Follow-Up Report. Water Environment Federation, 2018. Accessed June 10, 2025. https://www.accesswater.org/?id=-293632CITANCHOR.
Jennifer N. Brogdon# Charles L. McEntyre# Jonathan H. Walker# A. Chevales Williams
Tennessee Valley Marina and Campground Wastewater Characterization Screening Study Follow-Up Report
Access Water
Water Environment Federation
December 22, 2018
June 10, 2025
https://www.accesswater.org/?id=-293632CITANCHOR