lastID = -296330
Skip to main content Skip to top navigation Skip to site search
Top of page
  • My citations options
    Web Back (from Web)
    Chicago Back (from Chicago)
    MLA Back (from MLA)
Close action menu

You need to login to use this feature.

Please wait a moment…
Please wait while we update your results...
Please wait a moment...
Description: Access Water
Context Menu
Description: Book cover
Pulse Aeration of Secondary Aeration Tanks Holds Energy Saving Potential without Compromising Effluent Quality
  • Browse
  • Compilations
    • Compilations list
  • Subscriptions
Tools

Related contents

Loading related content

Workflow

No linked records yet

X
  • Current: 2022-05-04 18:29:26 Adam Phillips
  • 2022-05-04 18:29:25 Adam Phillips
  • 2020-02-01 03:25:06 Administrator
  • 2020-02-01 03:25:05 Administrator
  • 2020-02-01 03:25:04 Administrator
Description: Access Water
  • Browse
  • Compilations
  • Subscriptions
Log in
0
Accessibility Options

Base text size -

This is a sample piece of body text
Larger
Smaller
  • Shopping basket (0)
  • Accessibility options
  • Return to previous
Description: Book cover
Pulse Aeration of Secondary Aeration Tanks Holds Energy Saving Potential without Compromising Effluent Quality

Pulse Aeration of Secondary Aeration Tanks Holds Energy Saving Potential without Compromising Effluent Quality

Pulse Aeration of Secondary Aeration Tanks Holds Energy Saving Potential without Compromising Effluent Quality

  • New
  • View
  • Details
  • Reader
  • Default
  • Share
  • Email
  • Facebook
  • Twitter
  • LinkedIn
  • New
  • View
  • Default view
  • Reader view
  • Data view
  • Details

This page cannot be printed from here

Please use the dedicated print option from the 'view' drop down menu located in the blue ribbon in the top, right section of the publication.

screenshot of print menu option

Description: Book cover
Pulse Aeration of Secondary Aeration Tanks Holds Energy Saving Potential without Compromising Effluent Quality
Abstract
Results showed no serious effluent quality deterioration when continuously air-mixed anaerobic and anoxic quadrants of the San Jose/ Santa Clara Water Pollution plant's secondary aeration systems were operated in pulse aeration mode. Ammonia concentrations in pulse aerated and continuously aerated tanks were, on average, 0.73 mg/l and 0.63 mg/l, respectively. Such a slight increase in ammonia concentration in pulse aerated tanks was inevitable with reduction in air flow to Quad 3, although the final effluent quality was never affected. Nitrite concentrations were on average 0.15 mg/l and 0.17 mg/l in the pulse aerated and non pulsed tanks, respectively. Nitrate was significantly reduced from an average concentration of 7.26 mg/l in continuously aerated tanks to 4.45 mg/l in the pulse aerated tanks. Phosphate levels in the effluents of pulse aerated experimental tanks were found to be higher than those in continuously aerated control tanks with averages of 2 mg/l and 1.5 mg/l, respectively. No significant difference was observed in mixed liquor suspended solids concentrations between pulse aerated and continuously aerated tanks, signifying that the chosen pulse aeration cycle of 1.5 min ON/10.5 min OFF was, indeed, sufficient to keep solids in suspension. Tanks with pulse aerated anaerobic and anoxic compartments produced final effluent as superior in quality to the NPDES permit requirements as those that were not pulse aerated. The study demonstrated implementation of pulse aeration in anaerobic and anoxic quadrants would result in 13% less total aeration demand with associated annual energy saving potential close to 430,000.
Results showed no serious effluent quality deterioration when continuously air-mixed anaerobic and anoxic quadrants of the San Jose/ Santa Clara Water Pollution plant's secondary aeration systems were operated in pulse aeration mode. Ammonia concentrations in pulse aerated and continuously aerated tanks were, on average, 0.73 mg/l and 0.63 mg/l, respectively. Such a slight increase in ammonia...
Author(s)
Issayas T. LemmaSteve ColbyTom Herrington
SourceProceedings of the Water Environment Federation
SubjectSession 39 - Biological Nitrogen Transformations
Document typeConference Paper
PublisherWater Environment Federation
Print publication date Jan, 2009
ISSN1938-6478
SICI1938-6478(20090101)2009:15L.2390;1-
DOI10.2175/193864709802769993
Volume / Issue2009 / 15
Content sourceWEFTEC
First / last page(s)2390 - 2401
Copyright2009
Word count261
Subject keywordspulse aerationaeration energy savingsolids mixinganaerobicanoxiceffluent quality

Purchase price $11.50

Get access
Log in Purchase content Purchase subscription
You may already have access to this content if you have previously purchased this content or have a subscription.
Need to create an account?

You can purchase access to this content but you might want to consider a subscription for a wide variety of items at a substantial discount!

Purchase access to 'Pulse Aeration of Secondary Aeration Tanks Holds Energy Saving Potential without Compromising Effluent Quality'

Add to cart
Purchase a subscription to gain access to 18,000+ Proceeding Papers, 25+ Fact Sheets, 20+ Technical Reports, 50+ magazine articles and select Technical Publications' chapters.
Loading items
There are no items to display at the moment.
Something went wrong trying to load these items.
Description: Book cover
Pulse Aeration of Secondary Aeration Tanks Holds Energy Saving Potential without Compromising Effluent Quality
Pricing
Non-member price: $11.50
Member price:
-296330
Get access
-296330
Log in Purchase content Purchase subscription
You may already have access to this content if you have previously purchased this content or have a subscription.
Need to create an account?

You can purchase access to this content but you might want to consider a subscription for a wide variety of items at a substantial discount!

Purchase access to 'Pulse Aeration of Secondary Aeration Tanks Holds Energy Saving Potential without Compromising Effluent Quality'

Add to cart
Purchase a subscription to gain access to 18,000+ Proceeding Papers, 25+ Fact Sheets, 20+ Technical Reports, 50+ magazine articles and select Technical Publications' chapters.

Details

Description: Book cover
Pulse Aeration of Secondary Aeration Tanks Holds Energy Saving Potential without Compromising Effluent Quality
Abstract
Results showed no serious effluent quality deterioration when continuously air-mixed anaerobic and anoxic quadrants of the San Jose/ Santa Clara Water Pollution plant's secondary aeration systems were operated in pulse aeration mode. Ammonia concentrations in pulse aerated and continuously aerated tanks were, on average, 0.73 mg/l and 0.63 mg/l, respectively. Such a slight increase in ammonia concentration in pulse aerated tanks was inevitable with reduction in air flow to Quad 3, although the final effluent quality was never affected. Nitrite concentrations were on average 0.15 mg/l and 0.17 mg/l in the pulse aerated and non pulsed tanks, respectively. Nitrate was significantly reduced from an average concentration of 7.26 mg/l in continuously aerated tanks to 4.45 mg/l in the pulse aerated tanks. Phosphate levels in the effluents of pulse aerated experimental tanks were found to be higher than those in continuously aerated control tanks with averages of 2 mg/l and 1.5 mg/l, respectively. No significant difference was observed in mixed liquor suspended solids concentrations between pulse aerated and continuously aerated tanks, signifying that the chosen pulse aeration cycle of 1.5 min ON/10.5 min OFF was, indeed, sufficient to keep solids in suspension. Tanks with pulse aerated anaerobic and anoxic compartments produced final effluent as superior in quality to the NPDES permit requirements as those that were not pulse aerated. The study demonstrated implementation of pulse aeration in anaerobic and anoxic quadrants would result in 13% less total aeration demand with associated annual energy saving potential close to 430,000.
Results showed no serious effluent quality deterioration when continuously air-mixed anaerobic and anoxic quadrants of the San Jose/ Santa Clara Water Pollution plant's secondary aeration systems were operated in pulse aeration mode. Ammonia concentrations in pulse aerated and continuously aerated tanks were, on average, 0.73 mg/l and 0.63 mg/l, respectively. Such a slight increase in ammonia...
Author(s)
Issayas T. LemmaSteve ColbyTom Herrington
SourceProceedings of the Water Environment Federation
SubjectSession 39 - Biological Nitrogen Transformations
Document typeConference Paper
PublisherWater Environment Federation
Print publication date Jan, 2009
ISSN1938-6478
SICI1938-6478(20090101)2009:15L.2390;1-
DOI10.2175/193864709802769993
Volume / Issue2009 / 15
Content sourceWEFTEC
First / last page(s)2390 - 2401
Copyright2009
Word count261
Subject keywordspulse aerationaeration energy savingsolids mixinganaerobicanoxiceffluent quality

Actions, changes & tasks

Outstanding Actions

Add action for paragraph

Current Changes

Add signficant change

Current Tasks

Add risk task

Connect with us

Follow us on Facebook
Follow us on Twitter
Connect to us on LinkedIn
Subscribe on YouTube
Powered by Librios Ltd
Powered by Librios Ltd
Authors
Terms of Use
Policies
Help
Accessibility
Contact us
Copyright © 2024 by the Water Environment Federation
Loading items
There are no items to display at the moment.
Something went wrong trying to load these items.
Description: WWTF Digital Boot 180x150
WWTF Digital (180x150)
Created on Jul 02
Websitehttps:/­/­www.wef.org/­wwtf?utm_medium=WWTF&utm_source=AccessWater&utm_campaign=WWTF
180x150
Issayas T. Lemma# Steve Colby# Tom Herrington. Pulse Aeration of Secondary Aeration Tanks Holds Energy Saving Potential without Compromising Effluent Quality. Alexandria, VA 22314-1994, USA: Water Environment Federation, 2018. Web. 6 Jun. 2025. <https://www.accesswater.org?id=-296330CITANCHOR>.
Issayas T. Lemma# Steve Colby# Tom Herrington. Pulse Aeration of Secondary Aeration Tanks Holds Energy Saving Potential without Compromising Effluent Quality. Alexandria, VA 22314-1994, USA: Water Environment Federation, 2018. Accessed June 6, 2025. https://www.accesswater.org/?id=-296330CITANCHOR.
Issayas T. Lemma# Steve Colby# Tom Herrington
Pulse Aeration of Secondary Aeration Tanks Holds Energy Saving Potential without Compromising Effluent Quality
Access Water
Water Environment Federation
December 22, 2018
June 6, 2025
https://www.accesswater.org/?id=-296330CITANCHOR