lastID = -297757
Skip to main content Skip to top navigation Skip to site search
Top of page
  • My citations options
    Web Back (from Web)
    Chicago Back (from Chicago)
    MLA Back (from MLA)
Close action menu

You need to login to use this feature.

Please wait a moment…
Please wait while we update your results...
Please wait a moment...
Description: Access Water
Context Menu
Description: Book cover
Applying European Olfactometry Standard EN 13725 for Odor Performance Testing in Milford Connecticut – Lessons Learned
  • Browse
  • Compilations
    • Compilations list
  • Subscriptions
Tools

Related contents

Loading related content

Workflow

No linked records yet

X
  • Current: 2022-06-14 20:22:20 Adam Phillips
  • 2022-06-14 20:22:18 Adam Phillips
  • 2020-03-27 00:02:11 Adam Phillips
  • 2020-03-27 00:02:10 Adam Phillips
  • 2020-01-31 19:51:52 Administrator
  • 2020-01-31 19:51:51 Administrator
Description: Access Water
  • Browse
  • Compilations
  • Subscriptions
Log in
0
Accessibility Options

Base text size -

This is a sample piece of body text
Larger
Smaller
  • Shopping basket (0)
  • Accessibility options
  • Return to previous
Description: Book cover
Applying European Olfactometry Standard EN 13725 for Odor Performance Testing in Milford Connecticut – Lessons Learned

Applying European Olfactometry Standard EN 13725 for Odor Performance Testing in Milford Connecticut – Lessons Learned

Applying European Olfactometry Standard EN 13725 for Odor Performance Testing in Milford Connecticut – Lessons Learned

  • New
  • View
  • Details
  • Reader
  • Default
  • Share
  • Email
  • Facebook
  • Twitter
  • LinkedIn
  • New
  • View
  • Default view
  • Reader view
  • Data view
  • Details

This page cannot be printed from here

Please use the dedicated print option from the 'view' drop down menu located in the blue ribbon in the top, right section of the publication.

screenshot of print menu option

Description: Book cover
Applying European Olfactometry Standard EN 13725 for Odor Performance Testing in Milford Connecticut – Lessons Learned
Abstract
The City of Milford, Connecticut (City) is a residential coastal community located in the south central portion of the state approximately half way between the State of New York, and the State of Rhode Island. The City owns and operates two advanced wastewater treatment facilities (WWTF). The Housatonic WWTF is a 12.0 million gallon per day (mgd) activated sludge treatment facility that was upgraded using the Modified Ludzack-Ettinger (MLE) process for removal of total nitrogen. The Beaver Brook WWTF is a 3.0 million gallon per day (mgd) activated sludge treatment facility that was upgraded using the Modified Ludzack-Ettinger (MLE) process for removal of total nitrogen. The upgrading of both facilities was completed in the summer of 2009. Each facility included improvements to the preliminary treatment and sludge processing systems that were completed at the same time as the nitrogen removal improvements. Each facility was retrofitted with a new centralized odor control system that is designed to treat foul air that is exhausted from the Headworks, and Sludge Processing Facilities. Both facilities are located adjacent to residential neighborhoods that required effective odor containment, collection, and treatment to meet the neighborhood expectation of “no odors”.The odor control systems at each facility utilize multi-stage packed bed chemical scrubbers. The scrubbers are designed to treat foul air containing peak hydrogen sulfide (H2S) concentrations of 30 parts per million by volume (ppmv). The units are required to provide 98 percent removal of H2S and 90 percent odor removal. In the past odor control system performance testing followed American Society of Testing Materials ASTM E-679-04 – “Standard Practice for Determination of Taste and Odor Threshold by Forced Choice Ascending Concentration Series Method of Limits” (ASTM, 2004). Due to the sensitivity of the community to odors near the WWTF it was decided that an additional requirement would be included in the project specifications for odor control system performance testing. The performance testing specifications included an additional requirement to follow European Olfactometry Standard EN 13725:2003 – “Air Quality Determination of Odor Concentrations by Dynamic Olfactometry” (CEN, 2003) with respect to olfactometer design, calibration, sample air flow, sample air velocity, odor laboratory operation, assessor selection, and quality assurance/quality control procedures during laboratory testing. During the odor performance testing foul air from each process area was exhausted to the scrubber system. In addition, bottled H2S gas was metered into the airstream upstream of the scrubber system to maintain inlet H2S concentrations at 25 ppmv throughout the performance test to verify that the scrubber system will perform as specified at the design peak operating conditionsThe odor control system at the Housatonic WWTF treats airflows of 21,700 cfm from the Aerated Grit Chambers, Screenings Building, WAS Holding Tanks, Septage Holding Tanks, Solids Handling Building Belt Filter Press Room, Solids Handling Building Sludge Loading Garage Bay, and covered primary clarifier effluent launders. The odor control system at the Beaver Brook WWTF treats airflows of 9,800 cfm from the Influent Lift Station, Sludge Dewatering Room, Sludge Loading Garage Bay, and WAS Storage Tanks. During the performance testing inlet odor concentrations of up to 22,000 dilutions to threshold (D/T) were recorded. Outlet odor concentrations ranged from 600 to 800 D/T. The units both successfully completed the performance tests.This paper will outline the impacts that the EN 13725 requirements had on the project with respect to locating laboratories that actually conform to EN 13725, impacts on sample collection, sample holding time, impacts on the odor test results and other lessons learned during the Milford odor control system performance testing and subsequent operation.
The City of Milford, Connecticut (City) is a residential coastal community located in the south central portion of the state approximately half way between the State of New York, and the State of Rhode Island. The City owns and operates two advanced wastewater treatment facilities (WWTF). The Housatonic WWTF is a 12.0 million gallon per day (mgd) activated sludge treatment facility that was...
Author(s)
Robert B. StallingsCharles N. SmithKenneth Bradstreet
SourceProceedings of the Water Environment Federation
SubjectArticles
Document typeConference Paper
PublisherWater Environment Federation
Print publication date Jan, 2010
ISSN1938-6478
SICI1938-6478(20100101)2010:3L.233;1-
DOI10.2175/193864710802768253
Volume / Issue2010 / 3
Content sourceOdors and Air Pollutants Conference
First / last page(s)233 - 239
Copyright2010
Word count600
Subject keywordsOdor panelolfactometryodor concentrations

Purchase price $11.50

Get access
Log in Purchase content Purchase subscription
You may already have access to this content if you have previously purchased this content or have a subscription.
Need to create an account?

You can purchase access to this content but you might want to consider a subscription for a wide variety of items at a substantial discount!

Purchase access to 'Applying European Olfactometry Standard EN 13725 for Odor Performance Testing in Milford Connecticut – Lessons Learned'

Add to cart
Purchase a subscription to gain access to 18,000+ Proceeding Papers, 25+ Fact Sheets, 20+ Technical Reports, 50+ magazine articles and select Technical Publications' chapters.
Loading items
There are no items to display at the moment.
Something went wrong trying to load these items.
Description: Book cover
Applying European Olfactometry Standard EN 13725 for Odor Performance Testing in Milford Connecticut – Lessons Learned
Pricing
Non-member price: $11.50
Member price:
-297757
Get access
-297757
Log in Purchase content Purchase subscription
You may already have access to this content if you have previously purchased this content or have a subscription.
Need to create an account?

You can purchase access to this content but you might want to consider a subscription for a wide variety of items at a substantial discount!

Purchase access to 'Applying European Olfactometry Standard EN 13725 for Odor Performance Testing in Milford Connecticut – Lessons Learned'

Add to cart
Purchase a subscription to gain access to 18,000+ Proceeding Papers, 25+ Fact Sheets, 20+ Technical Reports, 50+ magazine articles and select Technical Publications' chapters.

Details

Description: Book cover
Applying European Olfactometry Standard EN 13725 for Odor Performance Testing in Milford Connecticut – Lessons Learned
Abstract
The City of Milford, Connecticut (City) is a residential coastal community located in the south central portion of the state approximately half way between the State of New York, and the State of Rhode Island. The City owns and operates two advanced wastewater treatment facilities (WWTF). The Housatonic WWTF is a 12.0 million gallon per day (mgd) activated sludge treatment facility that was upgraded using the Modified Ludzack-Ettinger (MLE) process for removal of total nitrogen. The Beaver Brook WWTF is a 3.0 million gallon per day (mgd) activated sludge treatment facility that was upgraded using the Modified Ludzack-Ettinger (MLE) process for removal of total nitrogen. The upgrading of both facilities was completed in the summer of 2009. Each facility included improvements to the preliminary treatment and sludge processing systems that were completed at the same time as the nitrogen removal improvements. Each facility was retrofitted with a new centralized odor control system that is designed to treat foul air that is exhausted from the Headworks, and Sludge Processing Facilities. Both facilities are located adjacent to residential neighborhoods that required effective odor containment, collection, and treatment to meet the neighborhood expectation of “no odors”.The odor control systems at each facility utilize multi-stage packed bed chemical scrubbers. The scrubbers are designed to treat foul air containing peak hydrogen sulfide (H2S) concentrations of 30 parts per million by volume (ppmv). The units are required to provide 98 percent removal of H2S and 90 percent odor removal. In the past odor control system performance testing followed American Society of Testing Materials ASTM E-679-04 – “Standard Practice for Determination of Taste and Odor Threshold by Forced Choice Ascending Concentration Series Method of Limits” (ASTM, 2004). Due to the sensitivity of the community to odors near the WWTF it was decided that an additional requirement would be included in the project specifications for odor control system performance testing. The performance testing specifications included an additional requirement to follow European Olfactometry Standard EN 13725:2003 – “Air Quality Determination of Odor Concentrations by Dynamic Olfactometry” (CEN, 2003) with respect to olfactometer design, calibration, sample air flow, sample air velocity, odor laboratory operation, assessor selection, and quality assurance/quality control procedures during laboratory testing. During the odor performance testing foul air from each process area was exhausted to the scrubber system. In addition, bottled H2S gas was metered into the airstream upstream of the scrubber system to maintain inlet H2S concentrations at 25 ppmv throughout the performance test to verify that the scrubber system will perform as specified at the design peak operating conditionsThe odor control system at the Housatonic WWTF treats airflows of 21,700 cfm from the Aerated Grit Chambers, Screenings Building, WAS Holding Tanks, Septage Holding Tanks, Solids Handling Building Belt Filter Press Room, Solids Handling Building Sludge Loading Garage Bay, and covered primary clarifier effluent launders. The odor control system at the Beaver Brook WWTF treats airflows of 9,800 cfm from the Influent Lift Station, Sludge Dewatering Room, Sludge Loading Garage Bay, and WAS Storage Tanks. During the performance testing inlet odor concentrations of up to 22,000 dilutions to threshold (D/T) were recorded. Outlet odor concentrations ranged from 600 to 800 D/T. The units both successfully completed the performance tests.This paper will outline the impacts that the EN 13725 requirements had on the project with respect to locating laboratories that actually conform to EN 13725, impacts on sample collection, sample holding time, impacts on the odor test results and other lessons learned during the Milford odor control system performance testing and subsequent operation.
The City of Milford, Connecticut (City) is a residential coastal community located in the south central portion of the state approximately half way between the State of New York, and the State of Rhode Island. The City owns and operates two advanced wastewater treatment facilities (WWTF). The Housatonic WWTF is a 12.0 million gallon per day (mgd) activated sludge treatment facility that was...
Author(s)
Robert B. StallingsCharles N. SmithKenneth Bradstreet
SourceProceedings of the Water Environment Federation
SubjectArticles
Document typeConference Paper
PublisherWater Environment Federation
Print publication date Jan, 2010
ISSN1938-6478
SICI1938-6478(20100101)2010:3L.233;1-
DOI10.2175/193864710802768253
Volume / Issue2010 / 3
Content sourceOdors and Air Pollutants Conference
First / last page(s)233 - 239
Copyright2010
Word count600
Subject keywordsOdor panelolfactometryodor concentrations

Actions, changes & tasks

Outstanding Actions

Add action for paragraph

Current Changes

Add signficant change

Current Tasks

Add risk task

Connect with us

Follow us on Facebook
Follow us on Twitter
Connect to us on LinkedIn
Subscribe on YouTube
Powered by Librios Ltd
Powered by Librios Ltd
Authors
Terms of Use
Policies
Help
Accessibility
Contact us
Copyright © 2024 by the Water Environment Federation
Loading items
There are no items to display at the moment.
Something went wrong trying to load these items.
Description: WWTF Digital Boot 180x150
WWTF Digital (180x150)
Created on Jul 02
Websitehttps:/­/­www.wef.org/­wwtf?utm_medium=WWTF&utm_source=AccessWater&utm_campaign=WWTF
180x150
Robert B. Stallings# Charles N. Smith# Kenneth Bradstreet. Applying European Olfactometry Standard EN 13725 for Odor Performance Testing in Milford Connecticut – Lessons Learned. Alexandria, VA 22314-1994, USA: Water Environment Federation, 2018. Web. 7 Jun. 2025. <https://www.accesswater.org?id=-297757CITANCHOR>.
Robert B. Stallings# Charles N. Smith# Kenneth Bradstreet. Applying European Olfactometry Standard EN 13725 for Odor Performance Testing in Milford Connecticut – Lessons Learned. Alexandria, VA 22314-1994, USA: Water Environment Federation, 2018. Accessed June 7, 2025. https://www.accesswater.org/?id=-297757CITANCHOR.
Robert B. Stallings# Charles N. Smith# Kenneth Bradstreet
Applying European Olfactometry Standard EN 13725 for Odor Performance Testing in Milford Connecticut – Lessons Learned
Access Water
Water Environment Federation
December 22, 2018
June 7, 2025
https://www.accesswater.org/?id=-297757CITANCHOR