Access Water | Reliable Wastewater Disinfection with Peracids: Integrating Batch Kinetics...
lastID = -10116220
Skip to main content Skip to top navigation Skip to site search
Top of page
  • My citations options
    Web Back (from Web)
    Chicago Back (from Chicago)
    MLA Back (from MLA)
Close action menu

You need to login to use this feature.

Please wait a moment…
Please wait while we update your results...
Please wait a moment...
Description: Access Water
Context Menu
Description: WEFTEC 2024 PROCEEDINGS
Reliable Wastewater Disinfection with Peracids: Integrating Batch Kinetics and Hydrodynamics
  • Browse
  • Compilations
    • Compilations list
  • Subscriptions
Tools

Related contents

Loading related content

Workflow

No linked records yet

X
  • Current: 2024-09-30 15:42:35 Adam Phillips Continuous release
  • 2024-09-26 15:13:51 Adam Phillips
Description: Access Water
  • Browse
  • Compilations
  • Subscriptions
Log in
0
Accessibility Options

Base text size -

This is a sample piece of body text
Larger
Smaller
  • Shopping basket (0)
  • Accessibility options
  • Return to previous
Description: WEFTEC 2024 PROCEEDINGS
Reliable Wastewater Disinfection with Peracids: Integrating Batch Kinetics and Hydrodynamics

Reliable Wastewater Disinfection with Peracids: Integrating Batch Kinetics and Hydrodynamics

Reliable Wastewater Disinfection with Peracids: Integrating Batch Kinetics and Hydrodynamics

  • New
  • View
  • Details
  • Reader
  • Default
  • Share
  • Email
  • Facebook
  • Twitter
  • LinkedIn
  • New
  • View
  • Default view
  • Reader view
  • Data view
  • Details

This page cannot be printed from here

Please use the dedicated print option from the 'view' drop down menu located in the blue ribbon in the top, right section of the publication.

screenshot of print menu option

Description: WEFTEC 2024 PROCEEDINGS
Reliable Wastewater Disinfection with Peracids: Integrating Batch Kinetics and Hydrodynamics
Abstract
INTRODUCTION Concerns related to the formation of disinfection byproducts (DBPs) during chlorine disinfection of wastewater and other safety concerns regarding chlorine operation initiated a great interest in alternative chemical disinfectants. For example, peracetic acid (PAA) received significant attention due to its minimal aquatic toxicity and efficacy in reducing regulated fecal indicator bacteria (FIB) (Antonelli et al., 2006; Manoli et al., 2019; WEF, 2020). The generally low efficacy of PAA in inactivating viruses in wastewater along with the ongoing discussions about revision of the United States Environmental Protection Agency Ambient Water Quality Criteria to include a viral indicator (Dunkin et al., 2017), led to a strong interest in another peracid, performic acid (PFA), which its bacterial and viral inactivation capacity usually outperforms PAA (Ragazzo et al., 2020). The objective of this study was to establish efficacy of PFA as a disinfectant compared to PAA and sodium hypochlorite for secondary effluent wastewater applications. The inactivation of indigenous FIB by PFA has been evaluated and compared with PAA and sodium hypochlorite under identical conditions. The disinfection data were interpreted using the concept of integral CT (ICT) and modeled by an ICT-based double-exponential microbial inactivation kinetic model to develop ICT-response data. This abstract presents the initial results of the Water Research Foundation Project #5219 titled 'Performic Acid Disinfection in Wastewater Effluent and CSOs In Context of Disinfection By-Products and Future Ambient Water Quality Criteria for Viruses', with the participation of more than 10 wastewater treatment plants (WWTPs) across the United States and Canada. Similar experiments with the ones presented herein for the first WWTP will be performed for all participating utilities, thus the results of this project may have a significant impact on disinfection practices in North America. Additional to FIB experiments, disinfection tests on viral indicators inactivation and DBPs formation will also be performed in the framework of this project. METHODS Secondary effluent wastewater was collected from a WWTP in ON, Canada (activated sludge-based processes). Its basic water quality characteristics were: pH=7.6, TSS=7.7 mg/L, BOD=10.8 mg/L, COD=13.5 mg/L, TN=18.6 mg/L, and TP=0.4 mg/L. Disinfection bench tests were performed in 2 L of wastewater at 2 disinfectant concentrations (1 and 2 mg/L for PFA and chlorine; 2 and 3 mg/L for PAA). Samples were collected at 6 contact times (0, 1, 3, 5, 10 and 30 min) and analyzed for disinfectant concentration (Chemetrics and Hach methods) and E. coli, fecal coliforms, total coliforms and enterococci (standard membrane filtration methods) (GAP EnviroMicrobial Services, London, ON, Canada). RESULTS The residual disinfectant concentration data were used to calculate exposure to chemical disinfectant (i.e., integral CT) by fitting initial demand (D, mg/L) and decay (k, 1/min) (Eq. 1): ICT=((C0-D)/k)∙(1-e^(-k∙t))(1) where ICT is the integral estimate of the time-dependant residual disinfectant concentration (mg min/L), C0 is the initial concentration of disinfectant (mg/L) and t is the contact time (min). The FIB inactivation data were plotted as a function of integral CT (Figures 1-4) and modeled by a double-exponential inactivation kinetic model in the domain of ICT (Eq. 2): N=N0∙(1-β)∙e^(-kd∙ICT^m )+N0∙(β)∙e^(-kp∙ICT)(2) where N0 and N are the initial and after treatment concentration of bacteria (CFU/100 mL), β is the fraction of particle-associated bacteria, m is a parameter that describes initial resistance of bacteria to disinfectant, and kd and kp are the ICT-based inactivation rate constants for dispersed (free) and particle-associated bacteria, in (L/(mg min))m and L/(mg min), respectively. PFA exhibited the highest inactivation efficiency for all studied indigenous FIB, followed by chlorine and PAA (Figures 1-4). For example, model-predicted integral CT requirements for 1-log reduction of total coliforms and enterococci were determined as 3-4 mg min/L, 8-10 mg min/L and 40-45 mg min/L for PFA, chlorine and PAA respectively (Figures 3 and 4). Based on model predictions, to achieve a 2-log reduction of both commonly regulated E. coli and fecal coliforms, PFA required ~10 times lower ICT than both PAA and chlorine (Figures 1 and 2). We also present an advanced disinfectant dosing control strategy that accounts for changes in wastewater quality and quantity, together with the hydrodynamics of the contact chamber. Bench test results of PFA (Eqs. 1 and 2) were integrated into a process model to evaluate four dosing strategies, namely, flow pacing, constant ICT, constant ICT advanced demand, and constant ICT advanced demand/decay. Figure 5 and Table 1 show that the advanced control strategy achieves consistent performance and optimizes disinfectant dosage. CONCLUSIONS Results show that PFA was superior to both PAA and chlorine. Although the PFA pricing estimates are currently higher than that of hypochlorite, the lower ICT requirements of PFA may result in a competitive cost compared to chlorine. This indicates the need for site-specific testing to better understand disinfection efficiency and cost benefits of PFA as a wastewater disinfectant.
The objective of this study was to establish disinfection efficacy of performic acid (PFA) compared to peracetic acid and sodium hypochlorite, for secondary effluent wastewater applications. The disinfection data were interpreted and modeled using the concept of integral CT, leading to the development of an advanced dose control strategy. PFA was the most effective disinfectant, and when combined with advanced process control, a consistent performance throughout the operation was achieved.
SpeakerManoli, Kyriakos
Presentation time
09:30:00
10:00:00
Session time
08:30:00
10:00:00
SessionPeracids Challenge Traditional Disinfectants
Session number503
Session locationRoom 338
TopicDisinfection and Public Health, Intermediate Level, Research and Innovation
TopicDisinfection and Public Health, Intermediate Level, Research and Innovation
Author(s)
Manoli, Kyriakos, Jang, Eunkyung, Mitobe, Sierra, Parra, Anggy, Diaz Rangel, Carlos, Bell, Katherine, Da Silva, Allegra, Oza, Shubhashini, Norton, John, Tikariha, Lomesh, Lawryshyn, Yuri, Santoro, Domenico
Author(s)K. Manoli1, K.Y. Bell2, E. Jang2, J. Norton3, S. Mitobe1, A. Parra4, C.A. Diaz Rangel1, A.K. Da Silva5, S. Oza6, L. Tikariha7, Y. Lawryshyn7, D. Santoro8
Author affiliation(s)1Lambton Water Center, Research & Innovation, Lambton College, Ontario, 2Brown and Caldwell, CA, 2, 3Great Lakes Water Authority, IL, 4Lambton Water Center, Research & Innovation, Lambton College, 5Brown and Caldwell, CO, 6Brown and Caldwell, NC, 7University of Toronto, 8USP Technologies, GA
SourceProceedings of the Water Environment Federation
Document typeConference Paper
PublisherWater Environment Federation
Print publication date Oct 2024
DOI10.2175/193864718825159567
Volume / Issue
Content sourceWEFTEC
Copyright2024
Word count11

Purchase price $11.50

Get access
Log in Purchase content Purchase subscription
You may already have access to this content if you have previously purchased this content or have a subscription.
Need to create an account?

You can purchase access to this content but you might want to consider a subscription for a wide variety of items at a substantial discount!

Purchase access to 'Reliable Wastewater Disinfection with Peracids: Integrating Batch Kinetics and Hydrodynamics'

Add to cart
Purchase a subscription to gain access to 18,000+ Proceeding Papers, 25+ Fact Sheets, 20+ Technical Reports, 50+ magazine articles and select Technical Publications' chapters.
Loading items
There are no items to display at the moment.
Something went wrong trying to load these items.
Description: WEFTEC 2024 PROCEEDINGS
Reliable Wastewater Disinfection with Peracids: Integrating Batch Kinetics and Hydrodynamics
Pricing
Non-member price: $11.50
Member price:
-10116220
Get access
-10116220
Log in Purchase content Purchase subscription
You may already have access to this content if you have previously purchased this content or have a subscription.
Need to create an account?

You can purchase access to this content but you might want to consider a subscription for a wide variety of items at a substantial discount!

Purchase access to 'Reliable Wastewater Disinfection with Peracids: Integrating Batch Kinetics and Hydrodynamics'

Add to cart
Purchase a subscription to gain access to 18,000+ Proceeding Papers, 25+ Fact Sheets, 20+ Technical Reports, 50+ magazine articles and select Technical Publications' chapters.

Details

Description: WEFTEC 2024 PROCEEDINGS
Reliable Wastewater Disinfection with Peracids: Integrating Batch Kinetics and Hydrodynamics
Abstract
INTRODUCTION Concerns related to the formation of disinfection byproducts (DBPs) during chlorine disinfection of wastewater and other safety concerns regarding chlorine operation initiated a great interest in alternative chemical disinfectants. For example, peracetic acid (PAA) received significant attention due to its minimal aquatic toxicity and efficacy in reducing regulated fecal indicator bacteria (FIB) (Antonelli et al., 2006; Manoli et al., 2019; WEF, 2020). The generally low efficacy of PAA in inactivating viruses in wastewater along with the ongoing discussions about revision of the United States Environmental Protection Agency Ambient Water Quality Criteria to include a viral indicator (Dunkin et al., 2017), led to a strong interest in another peracid, performic acid (PFA), which its bacterial and viral inactivation capacity usually outperforms PAA (Ragazzo et al., 2020). The objective of this study was to establish efficacy of PFA as a disinfectant compared to PAA and sodium hypochlorite for secondary effluent wastewater applications. The inactivation of indigenous FIB by PFA has been evaluated and compared with PAA and sodium hypochlorite under identical conditions. The disinfection data were interpreted using the concept of integral CT (ICT) and modeled by an ICT-based double-exponential microbial inactivation kinetic model to develop ICT-response data. This abstract presents the initial results of the Water Research Foundation Project #5219 titled 'Performic Acid Disinfection in Wastewater Effluent and CSOs In Context of Disinfection By-Products and Future Ambient Water Quality Criteria for Viruses', with the participation of more than 10 wastewater treatment plants (WWTPs) across the United States and Canada. Similar experiments with the ones presented herein for the first WWTP will be performed for all participating utilities, thus the results of this project may have a significant impact on disinfection practices in North America. Additional to FIB experiments, disinfection tests on viral indicators inactivation and DBPs formation will also be performed in the framework of this project. METHODS Secondary effluent wastewater was collected from a WWTP in ON, Canada (activated sludge-based processes). Its basic water quality characteristics were: pH=7.6, TSS=7.7 mg/L, BOD=10.8 mg/L, COD=13.5 mg/L, TN=18.6 mg/L, and TP=0.4 mg/L. Disinfection bench tests were performed in 2 L of wastewater at 2 disinfectant concentrations (1 and 2 mg/L for PFA and chlorine; 2 and 3 mg/L for PAA). Samples were collected at 6 contact times (0, 1, 3, 5, 10 and 30 min) and analyzed for disinfectant concentration (Chemetrics and Hach methods) and E. coli, fecal coliforms, total coliforms and enterococci (standard membrane filtration methods) (GAP EnviroMicrobial Services, London, ON, Canada). RESULTS The residual disinfectant concentration data were used to calculate exposure to chemical disinfectant (i.e., integral CT) by fitting initial demand (D, mg/L) and decay (k, 1/min) (Eq. 1): ICT=((C0-D)/k)∙(1-e^(-k∙t))(1) where ICT is the integral estimate of the time-dependant residual disinfectant concentration (mg min/L), C0 is the initial concentration of disinfectant (mg/L) and t is the contact time (min). The FIB inactivation data were plotted as a function of integral CT (Figures 1-4) and modeled by a double-exponential inactivation kinetic model in the domain of ICT (Eq. 2): N=N0∙(1-β)∙e^(-kd∙ICT^m )+N0∙(β)∙e^(-kp∙ICT)(2) where N0 and N are the initial and after treatment concentration of bacteria (CFU/100 mL), β is the fraction of particle-associated bacteria, m is a parameter that describes initial resistance of bacteria to disinfectant, and kd and kp are the ICT-based inactivation rate constants for dispersed (free) and particle-associated bacteria, in (L/(mg min))m and L/(mg min), respectively. PFA exhibited the highest inactivation efficiency for all studied indigenous FIB, followed by chlorine and PAA (Figures 1-4). For example, model-predicted integral CT requirements for 1-log reduction of total coliforms and enterococci were determined as 3-4 mg min/L, 8-10 mg min/L and 40-45 mg min/L for PFA, chlorine and PAA respectively (Figures 3 and 4). Based on model predictions, to achieve a 2-log reduction of both commonly regulated E. coli and fecal coliforms, PFA required ~10 times lower ICT than both PAA and chlorine (Figures 1 and 2). We also present an advanced disinfectant dosing control strategy that accounts for changes in wastewater quality and quantity, together with the hydrodynamics of the contact chamber. Bench test results of PFA (Eqs. 1 and 2) were integrated into a process model to evaluate four dosing strategies, namely, flow pacing, constant ICT, constant ICT advanced demand, and constant ICT advanced demand/decay. Figure 5 and Table 1 show that the advanced control strategy achieves consistent performance and optimizes disinfectant dosage. CONCLUSIONS Results show that PFA was superior to both PAA and chlorine. Although the PFA pricing estimates are currently higher than that of hypochlorite, the lower ICT requirements of PFA may result in a competitive cost compared to chlorine. This indicates the need for site-specific testing to better understand disinfection efficiency and cost benefits of PFA as a wastewater disinfectant.
The objective of this study was to establish disinfection efficacy of performic acid (PFA) compared to peracetic acid and sodium hypochlorite, for secondary effluent wastewater applications. The disinfection data were interpreted and modeled using the concept of integral CT, leading to the development of an advanced dose control strategy. PFA was the most effective disinfectant, and when combined with advanced process control, a consistent performance throughout the operation was achieved.
SpeakerManoli, Kyriakos
Presentation time
09:30:00
10:00:00
Session time
08:30:00
10:00:00
SessionPeracids Challenge Traditional Disinfectants
Session number503
Session locationRoom 338
TopicDisinfection and Public Health, Intermediate Level, Research and Innovation
TopicDisinfection and Public Health, Intermediate Level, Research and Innovation
Author(s)
Manoli, Kyriakos, Jang, Eunkyung, Mitobe, Sierra, Parra, Anggy, Diaz Rangel, Carlos, Bell, Katherine, Da Silva, Allegra, Oza, Shubhashini, Norton, John, Tikariha, Lomesh, Lawryshyn, Yuri, Santoro, Domenico
Author(s)K. Manoli1, K.Y. Bell2, E. Jang2, J. Norton3, S. Mitobe1, A. Parra4, C.A. Diaz Rangel1, A.K. Da Silva5, S. Oza6, L. Tikariha7, Y. Lawryshyn7, D. Santoro8
Author affiliation(s)1Lambton Water Center, Research & Innovation, Lambton College, Ontario, 2Brown and Caldwell, CA, 2, 3Great Lakes Water Authority, IL, 4Lambton Water Center, Research & Innovation, Lambton College, 5Brown and Caldwell, CO, 6Brown and Caldwell, NC, 7University of Toronto, 8USP Technologies, GA
SourceProceedings of the Water Environment Federation
Document typeConference Paper
PublisherWater Environment Federation
Print publication date Oct 2024
DOI10.2175/193864718825159567
Volume / Issue
Content sourceWEFTEC
Copyright2024
Word count11

Actions, changes & tasks

Outstanding Actions

Add action for paragraph

Current Changes

Add signficant change

Current Tasks

Add risk task

Connect with us

Follow us on Facebook
Follow us on Twitter
Connect to us on LinkedIn
Subscribe on YouTube
Powered by Librios Ltd
Powered by Librios Ltd
Authors
Terms of Use
Policies
Help
Accessibility
Contact us
Copyright © 2024 by the Water Environment Federation
Loading items
There are no items to display at the moment.
Something went wrong trying to load these items.
Description: WWTF Digital Boot 180x150
WWTF Digital (180x150)
Created on Jul 02
Websitehttps:/­/­www.wef.org/­wwtf?utm_medium=WWTF&utm_source=AccessWater&utm_campaign=WWTF
180x150
Manoli, Kyriakos. Reliable Wastewater Disinfection with Peracids: Integrating Batch Kinetics and Hydrodynamics. Water Environment Federation, 2024. Web. 16 Jun. 2025. <https://www.accesswater.org?id=-10116220CITANCHOR>.
Manoli, Kyriakos. Reliable Wastewater Disinfection with Peracids: Integrating Batch Kinetics and Hydrodynamics. Water Environment Federation, 2024. Accessed June 16, 2025. https://www.accesswater.org/?id=-10116220CITANCHOR.
Manoli, Kyriakos
Reliable Wastewater Disinfection with Peracids: Integrating Batch Kinetics and Hydrodynamics
Access Water
Water Environment Federation
October 9, 2024
June 16, 2025
https://www.accesswater.org/?id=-10116220CITANCHOR