Access Water | Head-to-Head Continuous Aeration Performance Monitoring of Full-Scale...
lastID = -10128314
Skip to main content Skip to top navigation Skip to site search
Top of page
  • My citations options
    Web Back (from Web)
    Chicago Back (from Chicago)
    MLA Back (from MLA)
Close action menu

You need to login to use this feature.

Please wait a moment…
Please wait while we update your results...
Please wait a moment...
Loading icon
Description: Access Water
Context Menu
Description: Head-to-Head Continuous Aeration Performance Monitoring of Full-Scale Densified and...
Head-to-Head Continuous Aeration Performance Monitoring of Full-Scale Densified and Conventional Activated Systems
  • Browse
  • Compilations
    • Compilations list
  • Subscriptions
Tools

Related contents

Loading related content

Workflow

No linked records yet

X
  • Current: 2026-09-25 14:55:13 Chris Lewis Continuous release
  • 2026-09-11 21:05:35 Adam Phillips
  • 2026-09-11 10:58:15 Adam Phillips
Description: Access Water
  • Browse
  • Compilations
  • Subscriptions
Log in
0
Accessibility Options

Base text size -

This is a sample piece of body text
Larger
Smaller
  • Shopping basket (0)
  • Accessibility options
  • Return to previous
Description: Head-to-Head Continuous Aeration Performance Monitoring of Full-Scale Densified and...
Head-to-Head Continuous Aeration Performance Monitoring of Full-Scale Densified and Conventional Activated Systems

Head-to-Head Continuous Aeration Performance Monitoring of Full-Scale Densified and Conventional Activated Systems

Head-to-Head Continuous Aeration Performance Monitoring of Full-Scale Densified and Conventional Activated Systems

  • New
  • View
  • Details
  • Reader
  • Default
  • Share
  • Email
  • Facebook
  • Twitter
  • LinkedIn
  • New
  • View
  • Default view
  • Reader view
  • Data view
  • Details

This page cannot be printed from here

Please use the dedicated print option from the 'view' drop down menu located in the blue ribbon in the top, right section of the publication.

screenshot of print menu option

Description: Head-to-Head Continuous Aeration Performance Monitoring of Full-Scale Densified and...
Head-to-Head Continuous Aeration Performance Monitoring of Full-Scale Densified and Conventional Activated Systems
Abstract
[b]BACKGROUND AND OBJECTIVES[/b] Increased loads and constrained facility footprints are driving water resource recovery facilities (WRRFs) to adopt intensification strategies that increase treatment capacity without expanding tankage. Among these, densified activated sludge (DAS) is a promising and cost-effective approach that selectively wastes poorly settling floc through hydrocyclones, reducing the sludge volume index (SVI), increasing biomass inventory, and enabling higher clarifier loading rates. The benefits of DAS are well-documented, but little information is available on its aeration performance under full-scale conditions, particularly for in-process inefficiencies quantified by the alpha factor (aF). Because aeration represents the dominant energy demand at WRRFs, reliable aF values are essential for both proper design and operation of aeration systems. Metro Water Recovery's Robert W. Hite Water Treatment Facility (RWHTF) in Denver, Colorado, treats approximately 130 mgd of municipal wastewater. To evaluate process intensification strategies, a full-scale 2-MG treatment train, with a dedicated secondary clarifier and return activated sludge (RAS) was operated as a densification pilot in parallel with 11 conventional activated sludge (CAS) treatment trains. To assess aeration performance and generate representative aF values suitable for scale-up design, a continuous, side-by-side off-gas testing campaign was conducted on the DAS and CAS systems. The DAS system was configured as an anaerobic-anoxic-oxic (A2O) process in the North Aeration Basin 2 (NAB2), while the CAS train operated as a MLE process in the NAB4. In the DAS system, the IMLR can be routed to multiple upstream zones, but usually A3 (A2, A3 and A4, see Fig. 1). A4, a swing zone, was operated as anoxic during the testing. [b]TESTING METHODOLOGY[/b] Continuous off-gas testing was performed using the I-FLOAT™ system (Inflatable Fast Lightweight Off-gas Analysis Technology), enabling rapid deployment and automated, continuous monitoring of aeration performance and process emissions (see Fig. 2). Three locations per basin were monitored over 24-hour periods. Concurrent side-by-side testing was conducted using two hoods connected to a single analyzer alternating every 10 minutes, yielding one data point per zone every 20 minutes (see Fig 1). Testing followed ASCE 18-18 guidelines (ASCE, 2018). [b]RESULTS AND FINDINGS[/b] During testing, the DAS system operated at ~25% granule mass fraction, MLSS of 5,000 mg/L, and SVI₃₀ of 68 mL/g, compared to <5% granulation, 3,900 mg/L MLSS, and SVI₃₀ of 89 mL/g for CAS. Aerobic/total SRTs were approximately 11/14 days (DAS) and 6/8 days (CAS). Despite these differences, in Zone A6, DAS and CAS exhibited similar aeration performance, with average OTEs of ~8.3–8.4% and aF values of 0.42. Diurnal aF ranged from 0.32 to 0.55, highlighting substantial diurnal variability and the importance of performing continuous monitoring over spot-check testing. This zone operated at relatively high air fluxes (2.2 scfm/diffuser for DAS; 2.7 for CAS). Greater differences were observed in Zone B4, where average OTEs were 14.4 (DAS) and 22.0 (CAS), corresponding to aF values of 0.72 and 0.91. Both systems operated at lower air fluxes, with CAS exhibiting both higher aF and higher OTE (see Table 1). The lower aF observed for DAS in Zone B4 may be influenced by differences in bubble coalescence associated with higher MLSS and potential effects of microbial by-products (e.g., SMPs or EPS, Germain et al., 2007). However, these mechanisms were not confirmed, and MLSS differences alone are unlikely to fully explain the differences in aF, based on previous aF-MLSS correlation studies (Krampe & Krauth, 2003).The absence of similar discrepancies in Zone A6 suggests convergence of bubble behavior at higher air fluxes, regardless of differences in MLSS or microbial by-products. In Zone C4, DAS results were considered representative (OTE 13.4, aF 0.83), although data loss occurred over night. CAS data were excluded due to an air leakage that compromised the data. Oxygen uptake rates (OURs) were estimated via a similar approach presented in Reifsnyder et al., 2018. OURs values for CAS were approximately 15–20% higher than DAS across Zones A6 and B4. [b]CONCLUSIONS AND RELEVANCE[/b] This study presents a first-of-its-kind, continuous, full-scale, side-by-side off-gas comparison of DAS and CAS systems. Results indicate that in initial aerobic zones operating at higher air fluxes, DAS and CAS exhibit comparable aF values, supporting similar aeration sizing assumptions. However, at lower air fluxes in downstream zones, DAS systems exhibited reduced aF relative to CAS. Results imply that under low-air-flux conditions, downstream air demands in DAS systems may be approximately 15–20% higher than CAS to achieve equivalent oxygen transfer rates, which translates to larger aeration equipment sizing, increased capital costs, and higher operating expenses. These findings provide early, design-relevant insights into mechanistic differences in aeration performance of DAS and CAS systems, and provide the basis for future studies. Results reflect performance at the tested granule mass fraction. Further evaluation at higher fractions (e.g., >40%) is needed. Ongoing testing at re-balanced air fluxes will refine aF guidance for DAS systems under typical operating conditions.
This paper was presented at WEFTEC 2026 in New Orleans, Louisiana.
Presentation time
13:30:00
14:00:00
Session time
13:30:00
15:00:00
SessionDAS Design New Frontiers
Session locationErnest N. Morial Convention Center
TopicFacility Operations and Maintenance, Municipal Wastewater Treatment Design, Research and Innovation
TopicFacility Operations and Maintenance, Municipal Wastewater Treatment Design, Research and Innovation
Author(s)
Reifsnyder, Samuel, Zambrano, Jorge, Berninghaus, Ashley, Marron, Brian, Maltos, Rudy, Wisdom, Blair, Rauch-Williams, Tanja
Author(s)S. Reifsnyder1, J. Zambrano2, A. Berninghaus1, B. Marron2, R. Maltos2, B. Wisdom2, T. Rauch-Williams2
Author affiliation(s)Carollo Engineers, 1Carollo Engineers, 1Metro Water Recovery, 2Metro Water Recovery, 2Metro Water Recovery, 2Metro Water Recovery, 2
SourceProceedings of the Water Environment Federation
Document typeConference Paper
PublisherWater Environment Federation
Print publication date Sep 2026
DOI10.2175/193864718825160479
Volume / Issue
Content sourceWEFTEC
Copyright2026
Word count13

Purchase price $11.50

Get access
Log in Purchase content Purchase subscription
You may already have access to this content if you have previously purchased this content or have a subscription.
Need to create an account?

You can purchase access to this content but you might want to consider a subscription for a wide variety of items at a substantial discount!

Purchase access to 'Head-to-Head Continuous Aeration Performance Monitoring of Full-Scale Densified and Conventional Activated Systems'

Add to cart
Purchase a subscription to gain access to 18,000+ Proceeding Papers, 25+ Fact Sheets, 20+ Technical Reports, 50+ magazine articles and select Technical Publications' chapters.
Loading items
There are no items to display at the moment.
Something went wrong trying to load these items.
Description: Head-to-Head Continuous Aeration Performance Monitoring of Full-Scale Densified and...
Head-to-Head Continuous Aeration Performance Monitoring of Full-Scale Densified and Conventional Activated Systems
Pricing
Non-member price: $11.50
Member price:
-10128314
Get access
-10128314
Log in Purchase content Purchase subscription
You may already have access to this content if you have previously purchased this content or have a subscription.
Need to create an account?

You can purchase access to this content but you might want to consider a subscription for a wide variety of items at a substantial discount!

Purchase access to 'Head-to-Head Continuous Aeration Performance Monitoring of Full-Scale Densified and Conventional Activated Systems'

Add to cart
Purchase a subscription to gain access to 18,000+ Proceeding Papers, 25+ Fact Sheets, 20+ Technical Reports, 50+ magazine articles and select Technical Publications' chapters.

Details

Description: Head-to-Head Continuous Aeration Performance Monitoring of Full-Scale Densified and...
Head-to-Head Continuous Aeration Performance Monitoring of Full-Scale Densified and Conventional Activated Systems
Abstract
[b]BACKGROUND AND OBJECTIVES[/b] Increased loads and constrained facility footprints are driving water resource recovery facilities (WRRFs) to adopt intensification strategies that increase treatment capacity without expanding tankage. Among these, densified activated sludge (DAS) is a promising and cost-effective approach that selectively wastes poorly settling floc through hydrocyclones, reducing the sludge volume index (SVI), increasing biomass inventory, and enabling higher clarifier loading rates. The benefits of DAS are well-documented, but little information is available on its aeration performance under full-scale conditions, particularly for in-process inefficiencies quantified by the alpha factor (aF). Because aeration represents the dominant energy demand at WRRFs, reliable aF values are essential for both proper design and operation of aeration systems. Metro Water Recovery's Robert W. Hite Water Treatment Facility (RWHTF) in Denver, Colorado, treats approximately 130 mgd of municipal wastewater. To evaluate process intensification strategies, a full-scale 2-MG treatment train, with a dedicated secondary clarifier and return activated sludge (RAS) was operated as a densification pilot in parallel with 11 conventional activated sludge (CAS) treatment trains. To assess aeration performance and generate representative aF values suitable for scale-up design, a continuous, side-by-side off-gas testing campaign was conducted on the DAS and CAS systems. The DAS system was configured as an anaerobic-anoxic-oxic (A2O) process in the North Aeration Basin 2 (NAB2), while the CAS train operated as a MLE process in the NAB4. In the DAS system, the IMLR can be routed to multiple upstream zones, but usually A3 (A2, A3 and A4, see Fig. 1). A4, a swing zone, was operated as anoxic during the testing. [b]TESTING METHODOLOGY[/b] Continuous off-gas testing was performed using the I-FLOAT™ system (Inflatable Fast Lightweight Off-gas Analysis Technology), enabling rapid deployment and automated, continuous monitoring of aeration performance and process emissions (see Fig. 2). Three locations per basin were monitored over 24-hour periods. Concurrent side-by-side testing was conducted using two hoods connected to a single analyzer alternating every 10 minutes, yielding one data point per zone every 20 minutes (see Fig 1). Testing followed ASCE 18-18 guidelines (ASCE, 2018). [b]RESULTS AND FINDINGS[/b] During testing, the DAS system operated at ~25% granule mass fraction, MLSS of 5,000 mg/L, and SVI₃₀ of 68 mL/g, compared to <5% granulation, 3,900 mg/L MLSS, and SVI₃₀ of 89 mL/g for CAS. Aerobic/total SRTs were approximately 11/14 days (DAS) and 6/8 days (CAS). Despite these differences, in Zone A6, DAS and CAS exhibited similar aeration performance, with average OTEs of ~8.3–8.4% and aF values of 0.42. Diurnal aF ranged from 0.32 to 0.55, highlighting substantial diurnal variability and the importance of performing continuous monitoring over spot-check testing. This zone operated at relatively high air fluxes (2.2 scfm/diffuser for DAS; 2.7 for CAS). Greater differences were observed in Zone B4, where average OTEs were 14.4 (DAS) and 22.0 (CAS), corresponding to aF values of 0.72 and 0.91. Both systems operated at lower air fluxes, with CAS exhibiting both higher aF and higher OTE (see Table 1). The lower aF observed for DAS in Zone B4 may be influenced by differences in bubble coalescence associated with higher MLSS and potential effects of microbial by-products (e.g., SMPs or EPS, Germain et al., 2007). However, these mechanisms were not confirmed, and MLSS differences alone are unlikely to fully explain the differences in aF, based on previous aF-MLSS correlation studies (Krampe & Krauth, 2003).The absence of similar discrepancies in Zone A6 suggests convergence of bubble behavior at higher air fluxes, regardless of differences in MLSS or microbial by-products. In Zone C4, DAS results were considered representative (OTE 13.4, aF 0.83), although data loss occurred over night. CAS data were excluded due to an air leakage that compromised the data. Oxygen uptake rates (OURs) were estimated via a similar approach presented in Reifsnyder et al., 2018. OURs values for CAS were approximately 15–20% higher than DAS across Zones A6 and B4. [b]CONCLUSIONS AND RELEVANCE[/b] This study presents a first-of-its-kind, continuous, full-scale, side-by-side off-gas comparison of DAS and CAS systems. Results indicate that in initial aerobic zones operating at higher air fluxes, DAS and CAS exhibit comparable aF values, supporting similar aeration sizing assumptions. However, at lower air fluxes in downstream zones, DAS systems exhibited reduced aF relative to CAS. Results imply that under low-air-flux conditions, downstream air demands in DAS systems may be approximately 15–20% higher than CAS to achieve equivalent oxygen transfer rates, which translates to larger aeration equipment sizing, increased capital costs, and higher operating expenses. These findings provide early, design-relevant insights into mechanistic differences in aeration performance of DAS and CAS systems, and provide the basis for future studies. Results reflect performance at the tested granule mass fraction. Further evaluation at higher fractions (e.g., >40%) is needed. Ongoing testing at re-balanced air fluxes will refine aF guidance for DAS systems under typical operating conditions.
This paper was presented at WEFTEC 2026 in New Orleans, Louisiana.
Presentation time
13:30:00
14:00:00
Session time
13:30:00
15:00:00
SessionDAS Design New Frontiers
Session locationErnest N. Morial Convention Center
TopicFacility Operations and Maintenance, Municipal Wastewater Treatment Design, Research and Innovation
TopicFacility Operations and Maintenance, Municipal Wastewater Treatment Design, Research and Innovation
Author(s)
Reifsnyder, Samuel, Zambrano, Jorge, Berninghaus, Ashley, Marron, Brian, Maltos, Rudy, Wisdom, Blair, Rauch-Williams, Tanja
Author(s)S. Reifsnyder1, J. Zambrano2, A. Berninghaus1, B. Marron2, R. Maltos2, B. Wisdom2, T. Rauch-Williams2
Author affiliation(s)Carollo Engineers, 1Carollo Engineers, 1Metro Water Recovery, 2Metro Water Recovery, 2Metro Water Recovery, 2Metro Water Recovery, 2
SourceProceedings of the Water Environment Federation
Document typeConference Paper
PublisherWater Environment Federation
Print publication date Sep 2026
DOI10.2175/193864718825160479
Volume / Issue
Content sourceWEFTEC
Copyright2026
Word count13

Actions, changes & tasks

Outstanding Actions

Add action for paragraph

Current Changes

Add signficant change

Current Tasks

Add risk task

Connect with us

Follow us on Facebook
Follow us on Twitter
Connect to us on LinkedIn
Subscribe on YouTube
Powered by Librios Ltd
Powered by Librios Ltd
Authors
Terms of Use
Policies
Help
Accessibility
Contact us
Copyright © 2026 by the Water Environment Federation
Loading items
There are no items to display at the moment.
Something went wrong trying to load these items.
Description: WWTF Digital Boot 180x150
WWTF Digital (180x150)
Created on Jul 02
Websitehttps:/­/­www.wef.org/­wwtf?utm_medium=WWTF&utm_source=AccessWater&utm_campaign=WWTF
180x150
Reifsnyder, Samuel. Head-to-Head Continuous Aeration Performance Monitoring of Full-Scale Densified and Conventional Activated Systems. Water Environment Federation, 2026. Web. 9 Nov. 2026. <https://www.accesswater.org?id=-10128314CITANCHOR>.
Reifsnyder, Samuel. Head-to-Head Continuous Aeration Performance Monitoring of Full-Scale Densified and Conventional Activated Systems. Water Environment Federation, 2026. Accessed November 9, 2026. https://www.accesswater.org/?id=-10128314CITANCHOR.
Reifsnyder, Samuel
Head-to-Head Continuous Aeration Performance Monitoring of Full-Scale Densified and Conventional Activated Systems
Access Water
Water Environment Federation
September 29, 2026
November 9, 2026
https://www.accesswater.org/?id=-10128314CITANCHOR