lastID = -280424
Skip to main content Skip to top navigation Skip to site search
Top of page
  • My citations options
    Web Back (from Web)
    Chicago Back (from Chicago)
    MLA Back (from MLA)
Close action menu

You need to login to use this feature.

Please wait a moment…
Please wait while we update your results...
Please wait a moment...
Description: Access Water
Context Menu
Description: W12-Proceedings
Lessons Learned from Activated Carbon Odor Control Systems
  • Browse
  • Compilations
    • Compilations list
  • Subscriptions
Tools

Related contents

Loading related content

Workflow

No linked records yet

X
  • Current: 2020-03-31 01:04:26 Adam Phillips
  • 2020-03-31 01:04:25 Adam Phillips
  • 2020-02-01 00:57:36 Administrator
  • 2020-02-01 00:57:35 Administrator
Description: Access Water
  • Browse
  • Compilations
  • Subscriptions
Log in
0
Accessibility Options

Base text size -

This is a sample piece of body text
Larger
Smaller
  • Shopping basket (0)
  • Accessibility options
  • Return to previous
Description: W12-Proceedings
Lessons Learned from Activated Carbon Odor Control Systems

Lessons Learned from Activated Carbon Odor Control Systems

Lessons Learned from Activated Carbon Odor Control Systems

  • New
  • View
  • Details
  • Reader
  • Default
  • Share
  • Email
  • Facebook
  • Twitter
  • LinkedIn
  • New
  • View
  • Default view
  • Reader view
  • Data view
  • Details

This page cannot be printed from here

Please use the dedicated print option from the 'view' drop down menu located in the blue ribbon in the top, right section of the publication.

screenshot of print menu option

Description: W12-Proceedings
Lessons Learned from Activated Carbon Odor Control Systems
Abstract
As consultants, owners, operators, and vendors we feel good about extolling our successful and award-winning projects. It is our human nature to congratulate ourselves on the good things we do. I do not take issue with or dispute this practice. But, I do question those projects that do not go according to plan - that did not quite work out, did not meet expectations, and/or failed miserably. Do we as an industry encourage everyone to capture the miscues and then educate others on how not to do something the next time around, or do we simply bury these projects and that knowledge by sweeping them under the rug so that they can occur over and over again because we are too embarrassed by the outcome? We can all learn from our past mistakes, if only we were willing to admit them, and then educate others before they suffer from the same miscues.This paper presents the top twelve lessons learned associated with the design and operation of activated carbon odor control systems gathered from miscues experienced over the past nearly thirty years. Activated carbon, of course, has been a key player in the odor control arena for a long time. It has changed with the times to improve required performance; witness the growth from virgin, to impregnated, to catalytic carbon varieties and, has found its place as a single stage technology or as a second stage polishing step. No one questions its proven track record and its effectiveness in the right application. Nevertheless, its relatively simple layout, nonmechanically intensive design, lack of continuous by-product disposal, generally can provide a false sense of security unless we have paid attention to and understood many of the potential pratfalls of the activated carbon odor control system. Many of these pratfalls initially were not intuitively obvious to either the designer or operator of the technology. However, through practical experience gained over the years, these lessons learned can be shared. The top twelve lessons learned from designing and operating activated carbon systems are:#12. Install sample taps at three different levels of the activated carbon media bed.#11. Install differential pressure monitors across the activated carbon media bed.#10. Design for independently supported beds, particularly in dual bed vessels.#9. Design a bottom drain for the vessel instead of a side drain.#8. Avoid designing an exhaust stack with a hat.#7. Provide sample taps on the inlet and outlet (both outlets if it is a dual bed unit) air flows to allow for the monitoring of carbon performance.#6. Ensure that the carbon specifications are satisfied and monitor how it is loaded into the vessel (avoid fines in the carbon delivered and from being created, based on how they load the vessel).#5. A good practice is to place bed limiters on the top and bottom of your carbon media bed(s).#4. Carefully design the inlet air connection in a dual bed orientation to avoid shortcircuiting, furrowing and fluidizing surface carbon.#3. Install pre-filters in front of the activated carbon vessel to avoid potential blinding of the carbon.#2. Do not allow water to accumulate in the bottom of a carbon vessel, particularly in a dual bed orientation.#1. Carbon fires can occur! Know the limitations of the activated carbon being used.Each of these two twelve lessons learned will be discussed in detail with anecdotal references to real life situations. The reader/attendee will walk away with a more thorough understanding of how to more effectively design/operate an activated carbon odor control system.
As consultants, owners, operators, and vendors we feel good about extolling our successful and award-winning projects. It is our human nature to congratulate ourselves on the good things we do. I do not take issue with or dispute this practice. But, I do question those projects that do not go according to plan - that did not quite work out, did not meet expectations, and/or failed miserably. Do we...
Author(s)
Richard J. Pope
SourceProceedings of the Water Environment Federation
Document typeConference Paper
PublisherWater Environment Federation
Print publication date Sep, 2012
ISSN1938-6478
DOI10.2175/193864712811708617
Volume / Issue2012 / 12
Content sourceWEFTEC
Copyright2012
Word count597

Purchase price $11.50

Get access
Log in Purchase content Purchase subscription
You may already have access to this content if you have previously purchased this content or have a subscription.
Need to create an account?

You can purchase access to this content but you might want to consider a subscription for a wide variety of items at a substantial discount!

Purchase access to 'Lessons Learned from Activated Carbon Odor Control Systems'

Add to cart
Purchase a subscription to gain access to 18,000+ Proceeding Papers, 25+ Fact Sheets, 20+ Technical Reports, 50+ magazine articles and select Technical Publications' chapters.
Loading items
There are no items to display at the moment.
Something went wrong trying to load these items.
Description: W12-Proceedings
Lessons Learned from Activated Carbon Odor Control Systems
Pricing
Non-member price: $11.50
Member price:
-280424
Get access
-280424
Log in Purchase content Purchase subscription
You may already have access to this content if you have previously purchased this content or have a subscription.
Need to create an account?

You can purchase access to this content but you might want to consider a subscription for a wide variety of items at a substantial discount!

Purchase access to 'Lessons Learned from Activated Carbon Odor Control Systems'

Add to cart
Purchase a subscription to gain access to 18,000+ Proceeding Papers, 25+ Fact Sheets, 20+ Technical Reports, 50+ magazine articles and select Technical Publications' chapters.

Details

Description: W12-Proceedings
Lessons Learned from Activated Carbon Odor Control Systems
Abstract
As consultants, owners, operators, and vendors we feel good about extolling our successful and award-winning projects. It is our human nature to congratulate ourselves on the good things we do. I do not take issue with or dispute this practice. But, I do question those projects that do not go according to plan - that did not quite work out, did not meet expectations, and/or failed miserably. Do we as an industry encourage everyone to capture the miscues and then educate others on how not to do something the next time around, or do we simply bury these projects and that knowledge by sweeping them under the rug so that they can occur over and over again because we are too embarrassed by the outcome? We can all learn from our past mistakes, if only we were willing to admit them, and then educate others before they suffer from the same miscues.This paper presents the top twelve lessons learned associated with the design and operation of activated carbon odor control systems gathered from miscues experienced over the past nearly thirty years. Activated carbon, of course, has been a key player in the odor control arena for a long time. It has changed with the times to improve required performance; witness the growth from virgin, to impregnated, to catalytic carbon varieties and, has found its place as a single stage technology or as a second stage polishing step. No one questions its proven track record and its effectiveness in the right application. Nevertheless, its relatively simple layout, nonmechanically intensive design, lack of continuous by-product disposal, generally can provide a false sense of security unless we have paid attention to and understood many of the potential pratfalls of the activated carbon odor control system. Many of these pratfalls initially were not intuitively obvious to either the designer or operator of the technology. However, through practical experience gained over the years, these lessons learned can be shared. The top twelve lessons learned from designing and operating activated carbon systems are:#12. Install sample taps at three different levels of the activated carbon media bed.#11. Install differential pressure monitors across the activated carbon media bed.#10. Design for independently supported beds, particularly in dual bed vessels.#9. Design a bottom drain for the vessel instead of a side drain.#8. Avoid designing an exhaust stack with a hat.#7. Provide sample taps on the inlet and outlet (both outlets if it is a dual bed unit) air flows to allow for the monitoring of carbon performance.#6. Ensure that the carbon specifications are satisfied and monitor how it is loaded into the vessel (avoid fines in the carbon delivered and from being created, based on how they load the vessel).#5. A good practice is to place bed limiters on the top and bottom of your carbon media bed(s).#4. Carefully design the inlet air connection in a dual bed orientation to avoid shortcircuiting, furrowing and fluidizing surface carbon.#3. Install pre-filters in front of the activated carbon vessel to avoid potential blinding of the carbon.#2. Do not allow water to accumulate in the bottom of a carbon vessel, particularly in a dual bed orientation.#1. Carbon fires can occur! Know the limitations of the activated carbon being used.Each of these two twelve lessons learned will be discussed in detail with anecdotal references to real life situations. The reader/attendee will walk away with a more thorough understanding of how to more effectively design/operate an activated carbon odor control system.
As consultants, owners, operators, and vendors we feel good about extolling our successful and award-winning projects. It is our human nature to congratulate ourselves on the good things we do. I do not take issue with or dispute this practice. But, I do question those projects that do not go according to plan - that did not quite work out, did not meet expectations, and/or failed miserably. Do we...
Author(s)
Richard J. Pope
SourceProceedings of the Water Environment Federation
Document typeConference Paper
PublisherWater Environment Federation
Print publication date Sep, 2012
ISSN1938-6478
DOI10.2175/193864712811708617
Volume / Issue2012 / 12
Content sourceWEFTEC
Copyright2012
Word count597

Actions, changes & tasks

Outstanding Actions

Add action for paragraph

Current Changes

Add signficant change

Current Tasks

Add risk task

Connect with us

Follow us on Facebook
Follow us on Twitter
Connect to us on LinkedIn
Subscribe on YouTube
Powered by Librios Ltd
Powered by Librios Ltd
Authors
Terms of Use
Policies
Help
Accessibility
Contact us
Copyright © 2024 by the Water Environment Federation
Loading items
There are no items to display at the moment.
Something went wrong trying to load these items.
Description: WWTF Digital Boot 180x150
WWTF Digital (180x150)
Created on Jul 02
Websitehttps:/­/­www.wef.org/­wwtf?utm_medium=WWTF&utm_source=AccessWater&utm_campaign=WWTF
180x150
Richard J. Pope. Lessons Learned from Activated Carbon Odor Control Systems. Alexandria, VA 22314-1994, USA: Water Environment Federation, 2018. Web. 22 Aug. 2025. <https://www.accesswater.org?id=-280424CITANCHOR>.
Richard J. Pope. Lessons Learned from Activated Carbon Odor Control Systems. Alexandria, VA 22314-1994, USA: Water Environment Federation, 2018. Accessed August 22, 2025. https://www.accesswater.org/?id=-280424CITANCHOR.
Richard J. Pope
Lessons Learned from Activated Carbon Odor Control Systems
Access Water
Water Environment Federation
December 22, 2018
August 22, 2025
https://www.accesswater.org/?id=-280424CITANCHOR