lastID = -280841
Skip to main content Skip to top navigation Skip to site search
Top of page
  • My citations options
    Web Back (from Web)
    Chicago Back (from Chicago)
    MLA Back (from MLA)
Close action menu

You need to login to use this feature.

Please wait a moment…
Please wait while we update your results...
Please wait a moment...
Description: Access Water
Context Menu
Description: OAP-Proceedings-2012
Optimizing a Large Scale Biofilter Treating Compost Exhaust Air
  • Browse
  • Compilations
    • Compilations list
  • Subscriptions
Tools

Related contents

Loading related content

Workflow

No linked records yet

X
  • Current: 2020-03-30 23:15:23 Adam Phillips
  • 2020-03-30 23:15:22 Adam Phillips
  • 2020-03-30 20:46:53 Adam Phillips
  • 2020-03-30 20:46:52 Adam Phillips
  • 2020-03-27 16:03:18 Katherine Saltzman
  • 2020-03-27 16:03:16 Katherine Saltzman
  • 2020-03-27 00:11:08 Adam Phillips
  • 2020-03-27 00:11:07 Adam Phillips
  • 2020-02-01 02:36:20 Administrator
  • 2020-02-01 02:36:19 Administrator
Description: Access Water
  • Browse
  • Compilations
  • Subscriptions
Log in
0
Accessibility Options

Base text size -

This is a sample piece of body text
Larger
Smaller
  • Shopping basket (0)
  • Accessibility options
  • Return to previous
Description: OAP-Proceedings-2012
Optimizing a Large Scale Biofilter Treating Compost Exhaust Air

Optimizing a Large Scale Biofilter Treating Compost Exhaust Air

Optimizing a Large Scale Biofilter Treating Compost Exhaust Air

  • New
  • View
  • Details
  • Reader
  • Default
  • Share
  • Email
  • Facebook
  • Twitter
  • LinkedIn
  • New
  • View
  • Default view
  • Reader view
  • Data view
  • Details

This page cannot be printed from here

Please use the dedicated print option from the 'view' drop down menu located in the blue ribbon in the top, right section of the publication.

screenshot of print menu option

Description: OAP-Proceedings-2012
Optimizing a Large Scale Biofilter Treating Compost Exhaust Air
Abstract
Summary of ProjectSynagro operates the South Kern Industrial Center (SKIC) compost facility in Bakersfield, CA, taking approximately 600 tons per day of biosolids from Southern California area wastewater treatment plants and producing a final compost product that meets Class A Exceptional Quality (EQ) standards under EPA 40 CFR Part 503 requirements. s. Composting is achieved in aerated static piles with negative air flow from two primary and two secondary compost operations exhausting processed air to biofilters. The two primary biofilters are 20,000 ft2 each with 6–7 feet of organic media and the two secondary biofilters are 11,000 ft2 each with 6–7 feet of organic media and. The wood chip based biofilters have pre humidification chambers, surface irrigation and laterals embedded in gravel for maximum air flow distribution. The hot compost exhaust air is cooled with ambient air pulled by cooling air fans which is mixed with the compost air prior to the biofilter. The lack of an easy water discharge (no sewers available) creates a water optimization challenge within the bio-filter process and at the site. This challenge is both in quantity of water sent to the on-site retention pond and also the quality issues associated with Ammonia (NH3) compounds removed by the biofilters. The SKIC compost and biofilter operation began in 2007, and has air permits issued by the San Joaquin Valley Air Pollution Control District to remove 80% of the Volatile Organic Compounds (VOCs) and 80% of the ammonia (NH3) leaving the biofilters. Each time the media is replaced, an extensive air emissions testing program is required to demonstrate compliance with the air permit.While the SKIC facility has not experienced any permit exceedances during the bi-annual testing events, it was believed that improvements in the air flow distribution network within each biofilter media would assist Synagro in optimizing water usage and maximize regulated constituent removal efficiencies. To assist in these optimization projects, Webster Environmental Associates, Inc. (WEA) was retained in the summer of 2011, to evaluate the current conditions, conduct testing and devise a plan to restore the biofilter to be able to meet performance on a long term basis. A second objective was to extend the life of the media because Synagro had been replacing the media every 2 years at a cost of about $400,000 for each occurrence. To accomplish both of these goals a detailed Process Engineering Sampling and Monitoring protocol was developed for use by the SKIC operational staff.The staff also desired to better understand the fate and removal of nitrogen from the biofilters. While the constituent of concern is Ammonia (NH3) which is removed readily – greater than 97% in the last source test – gaining additional knowledge for the speciation of N compounds and the potential process optimization were of great interest to the Synagro operational team.Status of the ProjectA diagnostic evaluation was conducted by WEA and several options were presented to Synagro to maximize the biofilter performance and minimize water flow to the retention basin. Air flow through the media provided for permit compliance it was not however always optimal in achieving superior Empty Bed Contact Time (EBCT). Synagro elected to proceed with a plan to install a new lateral system with a new configuration and additional gravel in the media underdrain. The added gravel improved the filters Empty Bed Contact Time (EBCT) and provides sufficient structural stability to allow the operational staff the ease of utilizing front end loaders to mix and fluff the biofilter media without harming the updated air flow lateral network. Other modifications such as better access to the “clean outs” were installed to improve the drainage within the biofilter and also to reduce the operational time required for the periodic flushing required. New media was placed onto all four biofilter beds and the system was started up in August, 2011 and a San Joaquin Valley Air Pollution Control District (SJVAPCD) source test was completed in September, 2011. The new biofilters met the APCD permit requirements, with a 97–99% removal efficiency of NH3 and an 88–94% removal efficiency of VOCs vs. the permitted levels of 80% for NH3 and 80% for VOC's.The Process Engineering and Monitoring Protocol developed by WEA were implemented by the Synagro operational staff. The scope of this plan includes: monitoring of the inlet temperature, pressure, flow and ammonia and the biofilter bed moisture, pH and ammonia. To assist in creating greater data consistency provided during the field sampling, a special sampling device was built for Synagro by Chuck E. Schmidt (CES Testing) to perform surface sampling and to check for even air distribution. An evaluation of the fate of ammonia in the biofilter, in terms of conversion to nitrates will be presented. By monitoring the biofilter and meeting process control objectives, Synagro's goal is to achieve a media life of 3–4 years for significant cost savings, while meeting air emission performance standards.
Summary of Project
Author(s)
Neil A. WebsterChibby Alloway
SourceProceedings of the Water Environment Federation
Document typeConference Paper
PublisherWater Environment Federation
Print publication date Apr, 2012
ISSN1938-6478
DOI10.2175/193864712811700534
Volume / Issue2012 / 3
Content sourceOdors and Air Pollutants Conference
Copyright2012
Word count827

Purchase price $11.50

Get access
Log in Purchase content Purchase subscription
You may already have access to this content if you have previously purchased this content or have a subscription.
Need to create an account?

You can purchase access to this content but you might want to consider a subscription for a wide variety of items at a substantial discount!

Purchase access to 'Optimizing a Large Scale Biofilter Treating Compost Exhaust Air'

Add to cart
Purchase a subscription to gain access to 18,000+ Proceeding Papers, 25+ Fact Sheets, 20+ Technical Reports, 50+ magazine articles and select Technical Publications' chapters.
Loading items
There are no items to display at the moment.
Something went wrong trying to load these items.
Description: OAP-Proceedings-2012
Optimizing a Large Scale Biofilter Treating Compost Exhaust Air
Pricing
Non-member price: $11.50
Member price:
-280841
Get access
-280841
Log in Purchase content Purchase subscription
You may already have access to this content if you have previously purchased this content or have a subscription.
Need to create an account?

You can purchase access to this content but you might want to consider a subscription for a wide variety of items at a substantial discount!

Purchase access to 'Optimizing a Large Scale Biofilter Treating Compost Exhaust Air'

Add to cart
Purchase a subscription to gain access to 18,000+ Proceeding Papers, 25+ Fact Sheets, 20+ Technical Reports, 50+ magazine articles and select Technical Publications' chapters.

Details

Description: OAP-Proceedings-2012
Optimizing a Large Scale Biofilter Treating Compost Exhaust Air
Abstract
Summary of ProjectSynagro operates the South Kern Industrial Center (SKIC) compost facility in Bakersfield, CA, taking approximately 600 tons per day of biosolids from Southern California area wastewater treatment plants and producing a final compost product that meets Class A Exceptional Quality (EQ) standards under EPA 40 CFR Part 503 requirements. s. Composting is achieved in aerated static piles with negative air flow from two primary and two secondary compost operations exhausting processed air to biofilters. The two primary biofilters are 20,000 ft2 each with 6–7 feet of organic media and the two secondary biofilters are 11,000 ft2 each with 6–7 feet of organic media and. The wood chip based biofilters have pre humidification chambers, surface irrigation and laterals embedded in gravel for maximum air flow distribution. The hot compost exhaust air is cooled with ambient air pulled by cooling air fans which is mixed with the compost air prior to the biofilter. The lack of an easy water discharge (no sewers available) creates a water optimization challenge within the bio-filter process and at the site. This challenge is both in quantity of water sent to the on-site retention pond and also the quality issues associated with Ammonia (NH3) compounds removed by the biofilters. The SKIC compost and biofilter operation began in 2007, and has air permits issued by the San Joaquin Valley Air Pollution Control District to remove 80% of the Volatile Organic Compounds (VOCs) and 80% of the ammonia (NH3) leaving the biofilters. Each time the media is replaced, an extensive air emissions testing program is required to demonstrate compliance with the air permit.While the SKIC facility has not experienced any permit exceedances during the bi-annual testing events, it was believed that improvements in the air flow distribution network within each biofilter media would assist Synagro in optimizing water usage and maximize regulated constituent removal efficiencies. To assist in these optimization projects, Webster Environmental Associates, Inc. (WEA) was retained in the summer of 2011, to evaluate the current conditions, conduct testing and devise a plan to restore the biofilter to be able to meet performance on a long term basis. A second objective was to extend the life of the media because Synagro had been replacing the media every 2 years at a cost of about $400,000 for each occurrence. To accomplish both of these goals a detailed Process Engineering Sampling and Monitoring protocol was developed for use by the SKIC operational staff.The staff also desired to better understand the fate and removal of nitrogen from the biofilters. While the constituent of concern is Ammonia (NH3) which is removed readily – greater than 97% in the last source test – gaining additional knowledge for the speciation of N compounds and the potential process optimization were of great interest to the Synagro operational team.Status of the ProjectA diagnostic evaluation was conducted by WEA and several options were presented to Synagro to maximize the biofilter performance and minimize water flow to the retention basin. Air flow through the media provided for permit compliance it was not however always optimal in achieving superior Empty Bed Contact Time (EBCT). Synagro elected to proceed with a plan to install a new lateral system with a new configuration and additional gravel in the media underdrain. The added gravel improved the filters Empty Bed Contact Time (EBCT) and provides sufficient structural stability to allow the operational staff the ease of utilizing front end loaders to mix and fluff the biofilter media without harming the updated air flow lateral network. Other modifications such as better access to the “clean outs” were installed to improve the drainage within the biofilter and also to reduce the operational time required for the periodic flushing required. New media was placed onto all four biofilter beds and the system was started up in August, 2011 and a San Joaquin Valley Air Pollution Control District (SJVAPCD) source test was completed in September, 2011. The new biofilters met the APCD permit requirements, with a 97–99% removal efficiency of NH3 and an 88–94% removal efficiency of VOCs vs. the permitted levels of 80% for NH3 and 80% for VOC's.The Process Engineering and Monitoring Protocol developed by WEA were implemented by the Synagro operational staff. The scope of this plan includes: monitoring of the inlet temperature, pressure, flow and ammonia and the biofilter bed moisture, pH and ammonia. To assist in creating greater data consistency provided during the field sampling, a special sampling device was built for Synagro by Chuck E. Schmidt (CES Testing) to perform surface sampling and to check for even air distribution. An evaluation of the fate of ammonia in the biofilter, in terms of conversion to nitrates will be presented. By monitoring the biofilter and meeting process control objectives, Synagro's goal is to achieve a media life of 3–4 years for significant cost savings, while meeting air emission performance standards.
Summary of Project
Author(s)
Neil A. WebsterChibby Alloway
SourceProceedings of the Water Environment Federation
Document typeConference Paper
PublisherWater Environment Federation
Print publication date Apr, 2012
ISSN1938-6478
DOI10.2175/193864712811700534
Volume / Issue2012 / 3
Content sourceOdors and Air Pollutants Conference
Copyright2012
Word count827

Actions, changes & tasks

Outstanding Actions

Add action for paragraph

Current Changes

Add signficant change

Current Tasks

Add risk task

Connect with us

Follow us on Facebook
Follow us on Twitter
Connect to us on LinkedIn
Subscribe on YouTube
Powered by Librios Ltd
Powered by Librios Ltd
Authors
Terms of Use
Policies
Help
Accessibility
Contact us
Copyright © 2024 by the Water Environment Federation
Loading items
There are no items to display at the moment.
Something went wrong trying to load these items.
Description: WWTF Digital Boot 180x150
WWTF Digital (180x150)
Created on Jul 02
Websitehttps:/­/­www.wef.org/­wwtf?utm_medium=WWTF&utm_source=AccessWater&utm_campaign=WWTF
180x150
Neil A. Webster# Chibby Alloway. Optimizing a Large Scale Biofilter Treating Compost Exhaust Air. Alexandria, VA 22314-1994, USA: Water Environment Federation, 2018. Web. 7 Jun. 2025. <https://www.accesswater.org?id=-280841CITANCHOR>.
Neil A. Webster# Chibby Alloway. Optimizing a Large Scale Biofilter Treating Compost Exhaust Air. Alexandria, VA 22314-1994, USA: Water Environment Federation, 2018. Accessed June 7, 2025. https://www.accesswater.org/?id=-280841CITANCHOR.
Neil A. Webster# Chibby Alloway
Optimizing a Large Scale Biofilter Treating Compost Exhaust Air
Access Water
Water Environment Federation
December 22, 2018
June 7, 2025
https://www.accesswater.org/?id=-280841CITANCHOR