lastID = -281528
Skip to main content Skip to top navigation Skip to site search
Top of page
  • My citations options
    Web Back (from Web)
    Chicago Back (from Chicago)
    MLA Back (from MLA)
Close action menu

You need to login to use this feature.

Please wait a moment…
Please wait while we update your results...
Please wait a moment...
Description: Access Water
Context Menu
Description: W13-Proceedings
Physical Modeling Leads to Improved Performance of Vortex Grit Basin
  • Browse
  • Compilations
    • Compilations list
  • Subscriptions
Tools

Related contents

Loading related content

Workflow

No linked records yet

X
  • Current: 2020-03-31 01:45:29 Adam Phillips
  • 2020-03-31 01:45:28 Adam Phillips
  • 2020-02-01 02:56:14 Administrator
  • 2020-02-01 02:56:13 Administrator
Description: Access Water
  • Browse
  • Compilations
  • Subscriptions
Log in
0
Accessibility Options

Base text size -

This is a sample piece of body text
Larger
Smaller
  • Shopping basket (0)
  • Accessibility options
  • Return to previous
Description: W13-Proceedings
Physical Modeling Leads to Improved Performance of Vortex Grit Basin

Physical Modeling Leads to Improved Performance of Vortex Grit Basin

Physical Modeling Leads to Improved Performance of Vortex Grit Basin

  • New
  • View
  • Details
  • Reader
  • Default
  • Share
  • Email
  • Facebook
  • Twitter
  • LinkedIn
  • New
  • View
  • Default view
  • Reader view
  • Data view
  • Details

This page cannot be printed from here

Please use the dedicated print option from the 'view' drop down menu located in the blue ribbon in the top, right section of the publication.

screenshot of print menu option

Description: W13-Proceedings
Physical Modeling Leads to Improved Performance of Vortex Grit Basin
Abstract
The Robert W. Hite Treatment Facility in Denver, Colorado is owned and operated by Metro Wastewater Reclamation District. The facility has a total rate capacity of 832.7 ML/d (220 mgd) based on maximum month flows. Their North Complex was upgraded in 2012 and among other improvements included modifying the existing four (4) vortex grit basins and constructing two (2) additional vortex grit basins. Grit deposition in the primary clarifiers provided evidence that the vortex grit basins were not efficiently capturing grit. As a result, a physical model was developed during pre-design to test various improvements to increase the grit capture efficiency. The physical model provided recommended improvements that were implemented during construction. Grit testing was performed prior to the improvements to provide base line grit capture efficiency of the existing units. Finally, grit testing was performed after construction to document the grit capture efficiencies and determine if the improvements were effective.
The Robert W. Hite Treatment Facility in Denver, Colorado is owned and operated by Metro Wastewater Reclamation District. The facility has a total rate capacity of 832.7 ML/d (220 mgd) based on maximum month flows. Their North Complex was upgraded in 2012 and among other improvements included modifying the existing four (4) vortex grit basins and constructing two (2) additional vortex grit basins....
Author(s)
Cody CharnasBrenda McMillanEdyta Stec-UddinSherman PapkeJoel RifeMark AllenTravis BoganRobert ArmstrongDavid Werth
SourceProceedings of the Water Environment Federation
Document typeConference Paper
PublisherWater Environment Federation
Print publication date Oct, 2013
ISSN1938-6478
DOI10.2175/193864713813673901
Volume / Issue2013 / 16
Content sourceWEFTEC
Copyright2013
Word count161

Purchase price $11.50

Get access
Log in Purchase content Purchase subscription
You may already have access to this content if you have previously purchased this content or have a subscription.
Need to create an account?

You can purchase access to this content but you might want to consider a subscription for a wide variety of items at a substantial discount!

Purchase access to 'Physical Modeling Leads to Improved Performance of Vortex Grit Basin'

Add to cart
Purchase a subscription to gain access to 18,000+ Proceeding Papers, 25+ Fact Sheets, 20+ Technical Reports, 50+ magazine articles and select Technical Publications' chapters.
Loading items
There are no items to display at the moment.
Something went wrong trying to load these items.
Description: W13-Proceedings
Physical Modeling Leads to Improved Performance of Vortex Grit Basin
Pricing
Non-member price: $11.50
Member price:
-281528
Get access
-281528
Log in Purchase content Purchase subscription
You may already have access to this content if you have previously purchased this content or have a subscription.
Need to create an account?

You can purchase access to this content but you might want to consider a subscription for a wide variety of items at a substantial discount!

Purchase access to 'Physical Modeling Leads to Improved Performance of Vortex Grit Basin'

Add to cart
Purchase a subscription to gain access to 18,000+ Proceeding Papers, 25+ Fact Sheets, 20+ Technical Reports, 50+ magazine articles and select Technical Publications' chapters.

Details

Description: W13-Proceedings
Physical Modeling Leads to Improved Performance of Vortex Grit Basin
Abstract
The Robert W. Hite Treatment Facility in Denver, Colorado is owned and operated by Metro Wastewater Reclamation District. The facility has a total rate capacity of 832.7 ML/d (220 mgd) based on maximum month flows. Their North Complex was upgraded in 2012 and among other improvements included modifying the existing four (4) vortex grit basins and constructing two (2) additional vortex grit basins. Grit deposition in the primary clarifiers provided evidence that the vortex grit basins were not efficiently capturing grit. As a result, a physical model was developed during pre-design to test various improvements to increase the grit capture efficiency. The physical model provided recommended improvements that were implemented during construction. Grit testing was performed prior to the improvements to provide base line grit capture efficiency of the existing units. Finally, grit testing was performed after construction to document the grit capture efficiencies and determine if the improvements were effective.
The Robert W. Hite Treatment Facility in Denver, Colorado is owned and operated by Metro Wastewater Reclamation District. The facility has a total rate capacity of 832.7 ML/d (220 mgd) based on maximum month flows. Their North Complex was upgraded in 2012 and among other improvements included modifying the existing four (4) vortex grit basins and constructing two (2) additional vortex grit basins....
Author(s)
Cody CharnasBrenda McMillanEdyta Stec-UddinSherman PapkeJoel RifeMark AllenTravis BoganRobert ArmstrongDavid Werth
SourceProceedings of the Water Environment Federation
Document typeConference Paper
PublisherWater Environment Federation
Print publication date Oct, 2013
ISSN1938-6478
DOI10.2175/193864713813673901
Volume / Issue2013 / 16
Content sourceWEFTEC
Copyright2013
Word count161

Actions, changes & tasks

Outstanding Actions

Add action for paragraph

Current Changes

Add signficant change

Current Tasks

Add risk task

Connect with us

Follow us on Facebook
Follow us on Twitter
Connect to us on LinkedIn
Subscribe on YouTube
Powered by Librios Ltd
Powered by Librios Ltd
Authors
Terms of Use
Policies
Help
Accessibility
Contact us
Copyright © 2024 by the Water Environment Federation
Loading items
There are no items to display at the moment.
Something went wrong trying to load these items.
Description: WWTF Digital Boot 180x150
WWTF Digital (180x150)
Created on Jul 02
Websitehttps:/­/­www.wef.org/­wwtf?utm_medium=WWTF&utm_source=AccessWater&utm_campaign=WWTF
180x150
Cody Charnas# Brenda McMillan# Edyta Stec-Uddin# Sherman Papke# Joel Rife# Mark Allen# Travis Bogan# Robert Armstrong# David Werth. Physical Modeling Leads to Improved Performance of Vortex Grit Basin. Alexandria, VA 22314-1994, USA: Water Environment Federation, 2018. Web. 5 Jun. 2025. <https://www.accesswater.org?id=-281528CITANCHOR>.
Cody Charnas# Brenda McMillan# Edyta Stec-Uddin# Sherman Papke# Joel Rife# Mark Allen# Travis Bogan# Robert Armstrong# David Werth. Physical Modeling Leads to Improved Performance of Vortex Grit Basin. Alexandria, VA 22314-1994, USA: Water Environment Federation, 2018. Accessed June 5, 2025. https://www.accesswater.org/?id=-281528CITANCHOR.
Cody Charnas# Brenda McMillan# Edyta Stec-Uddin# Sherman Papke# Joel Rife# Mark Allen# Travis Bogan# Robert Armstrong# David Werth
Physical Modeling Leads to Improved Performance of Vortex Grit Basin
Access Water
Water Environment Federation
December 22, 2018
June 5, 2025
https://www.accesswater.org/?id=-281528CITANCHOR