MINOR LOADING AND CONFIGURATION DIFFERENCES SIGNIFICANTLY AFFECT CLARIFIER PERFORMANCE AND CAPACITY AT THREE WWTPS IN PHILADELPHIA
  • Browse
  • Compilations
    • Compilations list
  • Subscriptions
Tools

Related contents

Loading related content

Workflow

No linked records yet

X
  • Current: 2022-05-06 14:38:47 Adam Phillips
  • 2022-05-06 14:38:46 Adam Phillips
  • 2020-02-01 01:33:11 Administrator
  • 2020-02-01 01:33:09 Administrator
  • 2020-02-01 01:33:08 Administrator
Description: Access Water
  • Browse
  • Compilations
  • Subscriptions
Log in
0
Accessibility Options

Base text size -

This is a sample piece of body text
Larger
Smaller
  • Shopping basket (0)
  • Accessibility options
  • Return to previous
Description: Book cover
MINOR LOADING AND CONFIGURATION DIFFERENCES SIGNIFICANTLY AFFECT CLARIFIER PERFORMANCE AND CAPACITY AT THREE WWTPS IN PHILADELPHIA

MINOR LOADING AND CONFIGURATION DIFFERENCES SIGNIFICANTLY AFFECT CLARIFIER PERFORMANCE AND CAPACITY AT THREE WWTPS IN PHILADELPHIA

MINOR LOADING AND CONFIGURATION DIFFERENCES SIGNIFICANTLY AFFECT CLARIFIER PERFORMANCE AND CAPACITY AT THREE WWTPS IN PHILADELPHIA

  • New
  • View
  • Details
  • Reader
  • Default
  • Share
  • Email
  • Facebook
  • Twitter
  • LinkedIn
  • New
  • View
  • Default view
  • Reader view
  • Data view
  • Details

This page cannot be printed from here

Please use the dedicated print option from the 'view' drop down menu located in the blue ribbon in the top, right section of the publication.

screenshot of print menu option

Description: Book cover
MINOR LOADING AND CONFIGURATION DIFFERENCES SIGNIFICANTLY AFFECT CLARIFIER PERFORMANCE AND CAPACITY AT THREE WWTPS IN PHILADELPHIA
Abstract
The Philadelphia Water Department (PWD) has initiated a program to minimize the Combined Sewer Overflows (CSOs) to local receiving waters. One of the strategies to increase treatment capacity and reduce the CSO volume is to maximize flow to be treated by the existing WPCPs during periods of wet weather. To implement this strategy effectively, PWD needs to have a clear understanding of the factors that affect the hydraulic capacity of the three WPCPs in their jurisdiction.The objective of the project was to determine the reliable maximum treatment capacity of the existing facilities and identify low capital cost methods of increasing the ability of the facilities to treat peak hydraulic flows associated with wet weather conditions. This paper presents the results of twelve stress tests performed on the primary and secondary clarifiers at the three facilities. The major physical characteristics of the clarifiers are very similar. However, the measured performance between clarifiers was significantly different. By comparing the results from the three facilities, the study documented the effect of variations in influent characteristics, operational procedures, and minor physical modifications on clarifier performance. The allowable peak overflow rates for the primary clarifiers ranged from 80 to 140 m3/m2/d. The allowable peak overflow rates for the secondary clarifiers ranged from 68 to 85 m3/m2/d. The capacity of the secondary clarifiers was limited at solids loading rates greater than 165 kg/m2/d.The stress test results defined the peak hydraulic capacity of the clarifiers. Data from the stress tests was also used to predict clarifier effluent quality as a function of hydraulic loading at flow rates less than peak capacity. This information was used to predict mass loading and percent removal achieved to ensure all NPDES permit requirements can be met. A regression analysis of the stress test results was used to determine the maximum flow rate that could be maintained for an infinite period of time (sustainable flow) that allows the facility to meet the daily, weekly, and monthly average mass loading and percent removal requirements. The confidence limits from the regression analysis can be adjusted to reflect the level of risk associated with the predicted result.
The Philadelphia Water Department (PWD) has initiated a program to minimize the Combined Sewer Overflows (CSOs) to local receiving waters. One of the strategies to increase treatment capacity and reduce the CSO volume is to maximize flow to be treated by the existing WPCPs during periods of wet weather. To implement this strategy effectively, PWD needs to have a clear understanding of the factors...
Author(s)
L. FergusonD. ChauvinT. FergusonS. AnjamG. Daigger
SourceProceedings of the Water Environment Federation
SubjectSession 48 - Facility Operations I: Plant Operation and Maintenance - Making Changes
Document typeConference Paper
PublisherWater Environment Federation
Print publication date Jan, 2000
ISSN1938-6478
SICI1938-6478(20000101)2000:10L.555;1-
DOI10.2175/193864700784545414
Volume / Issue2000 / 10
Content sourceWEFTEC
First / last page(s)555 - 574
Copyright2000
Word count369

Purchase price $11.50

Get access
Log in Purchase content Purchase subscription
You may already have access to this content if you have previously purchased this content or have a subscription.
Need to create an account?

You can purchase access to this content but you might want to consider a subscription for a wide variety of items at a substantial discount!

Purchase access to 'MINOR LOADING AND CONFIGURATION DIFFERENCES SIGNIFICANTLY AFFECT CLARIFIER PERFORMANCE AND CAPACITY AT THREE WWTPS IN PHILADELPHIA'

Add to cart
Purchase a subscription to gain access to 18,000+ Proceeding Papers, 25+ Fact Sheets, 20+ Technical Reports, 50+ magazine articles and select Technical Publications' chapters.
Loading items
There are no items to display at the moment.
Something went wrong trying to load these items.
Description: Book cover
MINOR LOADING AND CONFIGURATION DIFFERENCES SIGNIFICANTLY AFFECT CLARIFIER PERFORMANCE AND CAPACITY AT THREE WWTPS IN PHILADELPHIA
Pricing
Non-member price: $11.50
Member price:
-286890
Get access
-286890
Log in Purchase content Purchase subscription
You may already have access to this content if you have previously purchased this content or have a subscription.
Need to create an account?

You can purchase access to this content but you might want to consider a subscription for a wide variety of items at a substantial discount!

Purchase access to 'MINOR LOADING AND CONFIGURATION DIFFERENCES SIGNIFICANTLY AFFECT CLARIFIER PERFORMANCE AND CAPACITY AT THREE WWTPS IN PHILADELPHIA'

Add to cart
Purchase a subscription to gain access to 18,000+ Proceeding Papers, 25+ Fact Sheets, 20+ Technical Reports, 50+ magazine articles and select Technical Publications' chapters.

Details

Description: Book cover
MINOR LOADING AND CONFIGURATION DIFFERENCES SIGNIFICANTLY AFFECT CLARIFIER PERFORMANCE AND CAPACITY AT THREE WWTPS IN PHILADELPHIA
Abstract
The Philadelphia Water Department (PWD) has initiated a program to minimize the Combined Sewer Overflows (CSOs) to local receiving waters. One of the strategies to increase treatment capacity and reduce the CSO volume is to maximize flow to be treated by the existing WPCPs during periods of wet weather. To implement this strategy effectively, PWD needs to have a clear understanding of the factors that affect the hydraulic capacity of the three WPCPs in their jurisdiction.The objective of the project was to determine the reliable maximum treatment capacity of the existing facilities and identify low capital cost methods of increasing the ability of the facilities to treat peak hydraulic flows associated with wet weather conditions. This paper presents the results of twelve stress tests performed on the primary and secondary clarifiers at the three facilities. The major physical characteristics of the clarifiers are very similar. However, the measured performance between clarifiers was significantly different. By comparing the results from the three facilities, the study documented the effect of variations in influent characteristics, operational procedures, and minor physical modifications on clarifier performance. The allowable peak overflow rates for the primary clarifiers ranged from 80 to 140 m3/m2/d. The allowable peak overflow rates for the secondary clarifiers ranged from 68 to 85 m3/m2/d. The capacity of the secondary clarifiers was limited at solids loading rates greater than 165 kg/m2/d.The stress test results defined the peak hydraulic capacity of the clarifiers. Data from the stress tests was also used to predict clarifier effluent quality as a function of hydraulic loading at flow rates less than peak capacity. This information was used to predict mass loading and percent removal achieved to ensure all NPDES permit requirements can be met. A regression analysis of the stress test results was used to determine the maximum flow rate that could be maintained for an infinite period of time (sustainable flow) that allows the facility to meet the daily, weekly, and monthly average mass loading and percent removal requirements. The confidence limits from the regression analysis can be adjusted to reflect the level of risk associated with the predicted result.
The Philadelphia Water Department (PWD) has initiated a program to minimize the Combined Sewer Overflows (CSOs) to local receiving waters. One of the strategies to increase treatment capacity and reduce the CSO volume is to maximize flow to be treated by the existing WPCPs during periods of wet weather. To implement this strategy effectively, PWD needs to have a clear understanding of the factors...
Author(s)
L. FergusonD. ChauvinT. FergusonS. AnjamG. Daigger
SourceProceedings of the Water Environment Federation
SubjectSession 48 - Facility Operations I: Plant Operation and Maintenance - Making Changes
Document typeConference Paper
PublisherWater Environment Federation
Print publication date Jan, 2000
ISSN1938-6478
SICI1938-6478(20000101)2000:10L.555;1-
DOI10.2175/193864700784545414
Volume / Issue2000 / 10
Content sourceWEFTEC
First / last page(s)555 - 574
Copyright2000
Word count369

Actions, changes & tasks

Outstanding Actions

Add action for paragraph

Current Changes

Add signficant change

Current Tasks

Add risk task

Connect with us

Follow us on Facebook
Follow us on Twitter
Connect to us on LinkedIn
Subscribe on YouTube
Powered by Librios Ltd
Powered by Librios Ltd
Authors
Terms of Use
Policies
Help
Accessibility
Contact us
Copyright © 2024 by the Water Environment Federation
Loading items
There are no items to display at the moment.
Something went wrong trying to load these items.
Description: WWTF Digital Boot 180x150
WWTF Digital (180x150)
Created on Jul 02
Websitehttps:/­/­www.wef.org/­wwtf?utm_medium=WWTF&utm_source=AccessWater&utm_campaign=WWTF
180x150
L. Ferguson# D. Chauvin# T. Ferguson# S. Anjam# G. Daigger. MINOR LOADING AND CONFIGURATION DIFFERENCES SIGNIFICANTLY AFFECT CLARIFIER PERFORMANCE AND CAPACITY AT THREE WWTPS IN PHILADELPHIA. Alexandria, VA 22314-1994, USA: Water Environment Federation, 2018. Web. 5 Jun. 2025. <https://www.accesswater.org?id=-286890CITANCHOR>.
L. Ferguson# D. Chauvin# T. Ferguson# S. Anjam# G. Daigger. MINOR LOADING AND CONFIGURATION DIFFERENCES SIGNIFICANTLY AFFECT CLARIFIER PERFORMANCE AND CAPACITY AT THREE WWTPS IN PHILADELPHIA. Alexandria, VA 22314-1994, USA: Water Environment Federation, 2018. Accessed June 5, 2025. https://www.accesswater.org/?id=-286890CITANCHOR.
L. Ferguson# D. Chauvin# T. Ferguson# S. Anjam# G. Daigger
MINOR LOADING AND CONFIGURATION DIFFERENCES SIGNIFICANTLY AFFECT CLARIFIER PERFORMANCE AND CAPACITY AT THREE WWTPS IN PHILADELPHIA
Access Water
Water Environment Federation
December 22, 2018
June 5, 2025
https://www.accesswater.org/?id=-286890CITANCHOR