lastID = -287056
Skip to main content Skip to top navigation Skip to site search
Top of page
  • My citations options
    Web Back (from Web)
    Chicago Back (from Chicago)
    MLA Back (from MLA)
Close action menu

You need to login to use this feature.

Please wait a moment…
Please wait while we update your results...
Please wait a moment...
Description: Access Water
Context Menu
Description: Book cover
LARGE DIAMETER SEWER AND TUNNEL VENTILATION CHARACTERISTICS AND ODOR CONTROL: RECENT DEVELOPMENTS AND CASE HISTORIES
  • Browse
  • Compilations
    • Compilations list
  • Subscriptions
Tools

Related contents

Loading related content

Workflow

No linked records yet

X
  • Current: 2022-05-06 11:24:02 Adam Phillips
  • 2022-05-06 11:24:01 Adam Phillips
  • 2020-02-01 00:54:25 Administrator
  • 2020-02-01 00:54:24 Administrator
Description: Access Water
  • Browse
  • Compilations
  • Subscriptions
Log in
0
Accessibility Options

Base text size -

This is a sample piece of body text
Larger
Smaller
  • Shopping basket (0)
  • Accessibility options
  • Return to previous
Description: Book cover
LARGE DIAMETER SEWER AND TUNNEL VENTILATION CHARACTERISTICS AND ODOR CONTROL: RECENT DEVELOPMENTS AND CASE HISTORIES

LARGE DIAMETER SEWER AND TUNNEL VENTILATION CHARACTERISTICS AND ODOR CONTROL: RECENT DEVELOPMENTS AND CASE HISTORIES

LARGE DIAMETER SEWER AND TUNNEL VENTILATION CHARACTERISTICS AND ODOR CONTROL: RECENT DEVELOPMENTS AND CASE HISTORIES

  • New
  • View
  • Details
  • Reader
  • Default
  • Share
  • Email
  • Facebook
  • Twitter
  • LinkedIn
  • New
  • View
  • Default view
  • Reader view
  • Data view
  • Details

This page cannot be printed from here

Please use the dedicated print option from the 'view' drop down menu located in the blue ribbon in the top, right section of the publication.

screenshot of print menu option

Description: Book cover
LARGE DIAMETER SEWER AND TUNNEL VENTILATION CHARACTERISTICS AND ODOR CONTROL: RECENT DEVELOPMENTS AND CASE HISTORIES
Abstract
The construction and operation of large diameter, sometimes deeply buried sewer interceptors over the past 15 years has proved to be a cost-effective way to divert and move wastewater in collection systems. Regionalization of wastewater treatment facilities has required larger and longer interceptors to reach the plants. Large diameter deep sewers allow the use of tunneling methods which avoid utility interferences and make construction less intrusive to the community. In flat topography, large diameter tunnel sewers allow the de-commissioning of costly and troublesome pumping stations and provide flow relief for widespread areas of shallow collection systems.However, with the advent of large diameter and deep interceptor sewers there has been an increased incidence of odor complaints due to unusual ventilation phenomenon. It has long been recognized by many utilities that their large diameter tunnel sewers can often ventilate in a dramatic and forceful manner. When the public has occasion to experience the exhausted air, odor complaints are the result. We have come to recognize the classical “deep tunnel” ventilation dynamics but the engineering community has had little formal education or hard data upon which to base designs for large diameter sewer ventilation correction. The issue of deep sewer ventilation has received more attention in the past 5 years and researchers are starting to develop relationships between flow volume, pipe diameter and slope, hydraulic friction factors, dropstructure configuration and airflow/pressure in a sewer.Recent work performed by the University of Edmonton, Alberta and the City of Los Angeles has shed new light on the issue of large diameter deep sewer ventilation rates. The success and failure of previous sewer ventilation correction designs have yielded specific empirical relationships between dropstructure design, sewer size, flowrate and sewer ventilation. In addition, refinement of the friction drag coefficients for normally flowing gravity sewers and tunnels has led to more accurate prediction of the full-scale ventilation potential. The City of Los Angeles is so confident of the new sewer ventilation criteria that they are using these relationships to predict odor complaint potential and to size odor control facilities during the design phase of a new large diameter tunnel sewer. Accurate prediction of ventilation phenomena and the size of control facilities are essential to prevent unexpected odor complaints. Pro-active incorporation of sewer ventilation and odor control designs into major interceptor and deep tunnel sewer designs prevents public relations problems following the startup of major public works projects. The Northeast Interceptor Sewer in Los Angeles, the Big Walnut/Rickenbacker Interceptor in Columbus Ohio and the Heights/Hilltop Interceptor in Cleveland Ohio are on-going design projects where in-line controls for odor and sewer ventilation are being incorporated into the preliminary design of the facilities.
The construction and operation of large diameter, sometimes deeply buried sewer interceptors over the past 15 years has proved to be a cost-effective way to divert and move wastewater in collection systems. Regionalization of wastewater treatment facilities has required larger and longer interceptors to reach the plants. Large diameter deep sewers allow the use of tunneling methods which avoid...
Author(s)
James JoyceHarvey W. SorensenMark M. Smith
SourceProceedings of the Water Environment Federation
SubjectSession 13 - Facility Operations II: Management of Odors and VOCs I
Document typeConference Paper
PublisherWater Environment Federation
Print publication date Jan, 2000
ISSN1938-6478
SICI1938-6478(20000101)2000:13L.195;1-
DOI10.2175/193864700784608171
Volume / Issue2000 / 13
Content sourceWEFTEC
First / last page(s)195 - 214
Copyright2000
Word count457

Purchase price $11.50

Get access
Log in Purchase content Purchase subscription
You may already have access to this content if you have previously purchased this content or have a subscription.
Need to create an account?

You can purchase access to this content but you might want to consider a subscription for a wide variety of items at a substantial discount!

Purchase access to 'LARGE DIAMETER SEWER AND TUNNEL VENTILATION CHARACTERISTICS AND ODOR CONTROL: RECENT DEVELOPMENTS AND CASE HISTORIES'

Add to cart
Purchase a subscription to gain access to 18,000+ Proceeding Papers, 25+ Fact Sheets, 20+ Technical Reports, 50+ magazine articles and select Technical Publications' chapters.
Loading items
There are no items to display at the moment.
Something went wrong trying to load these items.
Description: Book cover
LARGE DIAMETER SEWER AND TUNNEL VENTILATION CHARACTERISTICS AND ODOR CONTROL: RECENT DEVELOPMENTS AND CASE HISTORIES
Pricing
Non-member price: $11.50
Member price:
-287056
Get access
-287056
Log in Purchase content Purchase subscription
You may already have access to this content if you have previously purchased this content or have a subscription.
Need to create an account?

You can purchase access to this content but you might want to consider a subscription for a wide variety of items at a substantial discount!

Purchase access to 'LARGE DIAMETER SEWER AND TUNNEL VENTILATION CHARACTERISTICS AND ODOR CONTROL: RECENT DEVELOPMENTS AND CASE HISTORIES'

Add to cart
Purchase a subscription to gain access to 18,000+ Proceeding Papers, 25+ Fact Sheets, 20+ Technical Reports, 50+ magazine articles and select Technical Publications' chapters.

Details

Description: Book cover
LARGE DIAMETER SEWER AND TUNNEL VENTILATION CHARACTERISTICS AND ODOR CONTROL: RECENT DEVELOPMENTS AND CASE HISTORIES
Abstract
The construction and operation of large diameter, sometimes deeply buried sewer interceptors over the past 15 years has proved to be a cost-effective way to divert and move wastewater in collection systems. Regionalization of wastewater treatment facilities has required larger and longer interceptors to reach the plants. Large diameter deep sewers allow the use of tunneling methods which avoid utility interferences and make construction less intrusive to the community. In flat topography, large diameter tunnel sewers allow the de-commissioning of costly and troublesome pumping stations and provide flow relief for widespread areas of shallow collection systems.However, with the advent of large diameter and deep interceptor sewers there has been an increased incidence of odor complaints due to unusual ventilation phenomenon. It has long been recognized by many utilities that their large diameter tunnel sewers can often ventilate in a dramatic and forceful manner. When the public has occasion to experience the exhausted air, odor complaints are the result. We have come to recognize the classical “deep tunnel” ventilation dynamics but the engineering community has had little formal education or hard data upon which to base designs for large diameter sewer ventilation correction. The issue of deep sewer ventilation has received more attention in the past 5 years and researchers are starting to develop relationships between flow volume, pipe diameter and slope, hydraulic friction factors, dropstructure configuration and airflow/pressure in a sewer.Recent work performed by the University of Edmonton, Alberta and the City of Los Angeles has shed new light on the issue of large diameter deep sewer ventilation rates. The success and failure of previous sewer ventilation correction designs have yielded specific empirical relationships between dropstructure design, sewer size, flowrate and sewer ventilation. In addition, refinement of the friction drag coefficients for normally flowing gravity sewers and tunnels has led to more accurate prediction of the full-scale ventilation potential. The City of Los Angeles is so confident of the new sewer ventilation criteria that they are using these relationships to predict odor complaint potential and to size odor control facilities during the design phase of a new large diameter tunnel sewer. Accurate prediction of ventilation phenomena and the size of control facilities are essential to prevent unexpected odor complaints. Pro-active incorporation of sewer ventilation and odor control designs into major interceptor and deep tunnel sewer designs prevents public relations problems following the startup of major public works projects. The Northeast Interceptor Sewer in Los Angeles, the Big Walnut/Rickenbacker Interceptor in Columbus Ohio and the Heights/Hilltop Interceptor in Cleveland Ohio are on-going design projects where in-line controls for odor and sewer ventilation are being incorporated into the preliminary design of the facilities.
The construction and operation of large diameter, sometimes deeply buried sewer interceptors over the past 15 years has proved to be a cost-effective way to divert and move wastewater in collection systems. Regionalization of wastewater treatment facilities has required larger and longer interceptors to reach the plants. Large diameter deep sewers allow the use of tunneling methods which avoid...
Author(s)
James JoyceHarvey W. SorensenMark M. Smith
SourceProceedings of the Water Environment Federation
SubjectSession 13 - Facility Operations II: Management of Odors and VOCs I
Document typeConference Paper
PublisherWater Environment Federation
Print publication date Jan, 2000
ISSN1938-6478
SICI1938-6478(20000101)2000:13L.195;1-
DOI10.2175/193864700784608171
Volume / Issue2000 / 13
Content sourceWEFTEC
First / last page(s)195 - 214
Copyright2000
Word count457

Actions, changes & tasks

Outstanding Actions

Add action for paragraph

Current Changes

Add signficant change

Current Tasks

Add risk task

Connect with us

Follow us on Facebook
Follow us on Twitter
Connect to us on LinkedIn
Subscribe on YouTube
Powered by Librios Ltd
Powered by Librios Ltd
Authors
Terms of Use
Policies
Help
Accessibility
Contact us
Copyright © 2024 by the Water Environment Federation
Loading items
There are no items to display at the moment.
Something went wrong trying to load these items.
Description: WWTF Digital Boot 180x150
WWTF Digital (180x150)
Created on Jul 02
Websitehttps:/­/­www.wef.org/­wwtf?utm_medium=WWTF&utm_source=AccessWater&utm_campaign=WWTF
180x150
James Joyce# Harvey W. Sorensen# Mark M. Smith. LARGE DIAMETER SEWER AND TUNNEL VENTILATION CHARACTERISTICS AND ODOR CONTROL: RECENT DEVELOPMENTS AND CASE HISTORIES. Alexandria, VA 22314-1994, USA: Water Environment Federation, 2018. Web. 1 Sep. 2025. <https://www.accesswater.org?id=-287056CITANCHOR>.
James Joyce# Harvey W. Sorensen# Mark M. Smith. LARGE DIAMETER SEWER AND TUNNEL VENTILATION CHARACTERISTICS AND ODOR CONTROL: RECENT DEVELOPMENTS AND CASE HISTORIES. Alexandria, VA 22314-1994, USA: Water Environment Federation, 2018. Accessed September 1, 2025. https://www.accesswater.org/?id=-287056CITANCHOR.
James Joyce# Harvey W. Sorensen# Mark M. Smith
LARGE DIAMETER SEWER AND TUNNEL VENTILATION CHARACTERISTICS AND ODOR CONTROL: RECENT DEVELOPMENTS AND CASE HISTORIES
Access Water
Water Environment Federation
December 22, 2018
September 1, 2025
https://www.accesswater.org/?id=-287056CITANCHOR