lastID = -287276
Skip to main content Skip to top navigation Skip to site search
Top of page
  • My citations options
    Web Back (from Web)
    Chicago Back (from Chicago)
    MLA Back (from MLA)
Close action menu

You need to login to use this feature.

Please wait a moment…
Please wait while we update your results...
Please wait a moment...
Description: Access Water
Context Menu
Description: Book cover
SWITCH TO CHLORAMINATION IMPROVES DISINFECTION EFFICIENCY OF AWT EFFLUENT TO MEET STRINGENT TOTAL COLIFORM STANDARD
  • Browse
  • Compilations
    • Compilations list
  • Subscriptions
Tools

Related contents

Loading related content

Workflow

No linked records yet

X
  • Current: 2022-06-14 20:11:04 Adam Phillips
  • 2022-06-14 20:11:03 Adam Phillips
  • 2020-03-26 22:53:48 Adam Phillips
  • 2020-02-01 04:45:03 Administrator
  • 2020-02-01 04:45:02 Administrator
Description: Access Water
  • Browse
  • Compilations
  • Subscriptions
Log in
0
Accessibility Options

Base text size -

This is a sample piece of body text
Larger
Smaller
  • Shopping basket (0)
  • Accessibility options
  • Return to previous
Description: Book cover
SWITCH TO CHLORAMINATION IMPROVES DISINFECTION EFFICIENCY OF AWT EFFLUENT TO MEET STRINGENT TOTAL COLIFORM STANDARD

SWITCH TO CHLORAMINATION IMPROVES DISINFECTION EFFICIENCY OF AWT EFFLUENT TO MEET STRINGENT TOTAL COLIFORM STANDARD

SWITCH TO CHLORAMINATION IMPROVES DISINFECTION EFFICIENCY OF AWT EFFLUENT TO MEET STRINGENT TOTAL COLIFORM STANDARD

  • New
  • View
  • Details
  • Reader
  • Default
  • Share
  • Email
  • Facebook
  • Twitter
  • LinkedIn
  • New
  • View
  • Default view
  • Reader view
  • Data view
  • Details

This page cannot be printed from here

Please use the dedicated print option from the 'view' drop down menu located in the blue ribbon in the top, right section of the publication.

screenshot of print menu option

Description: Book cover
SWITCH TO CHLORAMINATION IMPROVES DISINFECTION EFFICIENCY OF AWT EFFLUENT TO MEET STRINGENT TOTAL COLIFORM STANDARD
Abstract
The recent improvements at the City of Henderson (NV) Water Reclamation Facility have brought to the forefront the difficulties experienced at many POTW's to consistently meet stringent disinfection limits of high quality effluents. The City of Henderson practices reclamation with a self-imposed effluent standard of less than 2.2 MPN total coliform. Shortly after a switch to hypochlorite disinfection, there was a substantial increase in chlorine demand for disinfection and the ineffective use of the chlorine applied. The problem was traced to the lack of ammonia in the well-nitrified effluent, which resulted in chlorine reacting rapidly with organics rather than being available for disinfection. After evaluating possible solutions, the City decided to install an ammonium hydroxide feed system to create chloramines to improve disinfection. Pilot testing was performed to determine the effectiveness of the ammonium hydroxide, to determine if a reduction in chlorine usage could be realized, and determine the feasibility of eliminating the practice of rechlorination to create a residual for the reclaimed water distribution system.
The recent improvements at the City of Henderson (NV) Water Reclamation Facility have brought to the forefront the difficulties experienced at many POTW's to consistently meet stringent disinfection limits of high quality effluents. The City of Henderson practices reclamation with a self-imposed effluent standard of less than 2.2 MPN total coliform. Shortly after a switch to hypochlorite...
Author(s)
Tim Smith
SourceProceedings of the Water Environment Federation
SubjectSESSION 4: PART I CHLORINE BASED DISINFECTION KINETICS
Document typeConference Paper
PublisherWater Environment Federation
Print publication date Jan, 2000
ISSN1938-6478
SICI1938-6478(20000101)2000:2L.138;1-
DOI10.2175/193864700785372190
Volume / Issue2000 / 2
Content sourceDisinfection and Reuse Symposium
First / last page(s)138 - 144
Copyright2000
Word count181

Purchase price $11.50

Get access
Log in Purchase content Purchase subscription
You may already have access to this content if you have previously purchased this content or have a subscription.
Need to create an account?

You can purchase access to this content but you might want to consider a subscription for a wide variety of items at a substantial discount!

Purchase access to 'SWITCH TO CHLORAMINATION IMPROVES DISINFECTION EFFICIENCY OF AWT EFFLUENT TO MEET STRINGENT TOTAL COLIFORM STANDARD'

Add to cart
Purchase a subscription to gain access to 18,000+ Proceeding Papers, 25+ Fact Sheets, 20+ Technical Reports, 50+ magazine articles and select Technical Publications' chapters.
Loading items
There are no items to display at the moment.
Something went wrong trying to load these items.
Description: Book cover
SWITCH TO CHLORAMINATION IMPROVES DISINFECTION EFFICIENCY OF AWT EFFLUENT TO MEET STRINGENT TOTAL COLIFORM STANDARD
Pricing
Non-member price: $11.50
Member price:
-287276
Get access
-287276
Log in Purchase content Purchase subscription
You may already have access to this content if you have previously purchased this content or have a subscription.
Need to create an account?

You can purchase access to this content but you might want to consider a subscription for a wide variety of items at a substantial discount!

Purchase access to 'SWITCH TO CHLORAMINATION IMPROVES DISINFECTION EFFICIENCY OF AWT EFFLUENT TO MEET STRINGENT TOTAL COLIFORM STANDARD'

Add to cart
Purchase a subscription to gain access to 18,000+ Proceeding Papers, 25+ Fact Sheets, 20+ Technical Reports, 50+ magazine articles and select Technical Publications' chapters.

Details

Description: Book cover
SWITCH TO CHLORAMINATION IMPROVES DISINFECTION EFFICIENCY OF AWT EFFLUENT TO MEET STRINGENT TOTAL COLIFORM STANDARD
Abstract
The recent improvements at the City of Henderson (NV) Water Reclamation Facility have brought to the forefront the difficulties experienced at many POTW's to consistently meet stringent disinfection limits of high quality effluents. The City of Henderson practices reclamation with a self-imposed effluent standard of less than 2.2 MPN total coliform. Shortly after a switch to hypochlorite disinfection, there was a substantial increase in chlorine demand for disinfection and the ineffective use of the chlorine applied. The problem was traced to the lack of ammonia in the well-nitrified effluent, which resulted in chlorine reacting rapidly with organics rather than being available for disinfection. After evaluating possible solutions, the City decided to install an ammonium hydroxide feed system to create chloramines to improve disinfection. Pilot testing was performed to determine the effectiveness of the ammonium hydroxide, to determine if a reduction in chlorine usage could be realized, and determine the feasibility of eliminating the practice of rechlorination to create a residual for the reclaimed water distribution system.
The recent improvements at the City of Henderson (NV) Water Reclamation Facility have brought to the forefront the difficulties experienced at many POTW's to consistently meet stringent disinfection limits of high quality effluents. The City of Henderson practices reclamation with a self-imposed effluent standard of less than 2.2 MPN total coliform. Shortly after a switch to hypochlorite...
Author(s)
Tim Smith
SourceProceedings of the Water Environment Federation
SubjectSESSION 4: PART I CHLORINE BASED DISINFECTION KINETICS
Document typeConference Paper
PublisherWater Environment Federation
Print publication date Jan, 2000
ISSN1938-6478
SICI1938-6478(20000101)2000:2L.138;1-
DOI10.2175/193864700785372190
Volume / Issue2000 / 2
Content sourceDisinfection and Reuse Symposium
First / last page(s)138 - 144
Copyright2000
Word count181

Actions, changes & tasks

Outstanding Actions

Add action for paragraph

Current Changes

Add signficant change

Current Tasks

Add risk task

Connect with us

Follow us on Facebook
Follow us on Twitter
Connect to us on LinkedIn
Subscribe on YouTube
Powered by Librios Ltd
Powered by Librios Ltd
Authors
Terms of Use
Policies
Help
Accessibility
Contact us
Copyright © 2024 by the Water Environment Federation
Loading items
There are no items to display at the moment.
Something went wrong trying to load these items.
Description: WWTF Digital Boot 180x150
WWTF Digital (180x150)
Created on Jul 02
Websitehttps:/­/­www.wef.org/­wwtf?utm_medium=WWTF&utm_source=AccessWater&utm_campaign=WWTF
180x150
Tim Smith. SWITCH TO CHLORAMINATION IMPROVES DISINFECTION EFFICIENCY OF AWT EFFLUENT TO MEET STRINGENT TOTAL COLIFORM STANDARD. Alexandria, VA 22314-1994, USA: Water Environment Federation, 2018. Web. 29 Jun. 2025. <https://www.accesswater.org?id=-287276CITANCHOR>.
Tim Smith. SWITCH TO CHLORAMINATION IMPROVES DISINFECTION EFFICIENCY OF AWT EFFLUENT TO MEET STRINGENT TOTAL COLIFORM STANDARD. Alexandria, VA 22314-1994, USA: Water Environment Federation, 2018. Accessed June 29, 2025. https://www.accesswater.org/?id=-287276CITANCHOR.
Tim Smith
SWITCH TO CHLORAMINATION IMPROVES DISINFECTION EFFICIENCY OF AWT EFFLUENT TO MEET STRINGENT TOTAL COLIFORM STANDARD
Access Water
Water Environment Federation
December 22, 2018
June 29, 2025
https://www.accesswater.org/?id=-287276CITANCHOR