lastID = -288249
Skip to main content Skip to top navigation Skip to site search
Top of page
  • My citations options
    Web Back (from Web)
    Chicago Back (from Chicago)
    MLA Back (from MLA)
Close action menu

You need to login to use this feature.

Please wait a moment…
Please wait while we update your results...
Please wait a moment...
Description: Access Water
Context Menu
Description: Book cover
Hydraulic Energy Flushing Of Inverted Siphons
  • Browse
  • Compilations
    • Compilations list
  • Subscriptions
Tools

Related contents

Loading related content

Workflow

No linked records yet

X
  • Current: 2022-05-06 11:16:15 Adam Phillips
  • 2022-05-06 11:16:14 Adam Phillips
  • 2020-02-01 00:00:02 Administrator
  • 2020-02-01 00:00:01 Administrator
Description: Access Water
  • Browse
  • Compilations
  • Subscriptions
Log in
0
Accessibility Options

Base text size -

This is a sample piece of body text
Larger
Smaller
  • Shopping basket (0)
  • Accessibility options
  • Return to previous
Description: Book cover
Hydraulic Energy Flushing Of Inverted Siphons

Hydraulic Energy Flushing Of Inverted Siphons

Hydraulic Energy Flushing Of Inverted Siphons

  • New
  • View
  • Details
  • Reader
  • Default
  • Share
  • Email
  • Facebook
  • Twitter
  • LinkedIn
  • New
  • View
  • Default view
  • Reader view
  • Data view
  • Details

This page cannot be printed from here

Please use the dedicated print option from the 'view' drop down menu located in the blue ribbon in the top, right section of the publication.

screenshot of print menu option

Description: Book cover
Hydraulic Energy Flushing Of Inverted Siphons
Abstract
The City of Richmond, Virginia is located at the head of tide on the James River. The older central part of the City is served by a combined sewer system (CSS) that comprises about 12,000 acres. The largest basin in the system is the Shockoe Creek Basin area that is comprised of about 8,000 acres, about 2/3 of the overall system. The City began addressing Combined Sewer Overflow (CSO) control in the late 1970s by constructing a 38 million gallon “first flush” retention system on the Shockoe Creek Basin in the early 1980s. The Shockoe Creek Basin discharges into a diversion structure at the retention system through an arch sewer. A crest dam in the Outfall Structure, down stream of the Diversion Structure, prevents dry weather flow from overflowing into the river. Flows into this structure are transferred to the Wastewater Treatment Plant (WWTP), across the James River using two 66-inch inverted siphon pipelines. The siphons have a firm capacity of 200 mgd. Flows feeding the river crossing vary from a dry weather flow of approximately 30 mgd to a wet weather flow of about 60 mgd. These wet weather CSO flows are very turbulent and sediment laden. Wet weather CSO events after the winter driving season contribute large quantities of sand and grit. Over time, deposition of solids in the twin river crossing can reduce the flow capacity of the inverted siphons pipelines, reducing transfer capacity to the wastewater treatment plant. This plugging causes operations personnel to modify standard operating procedures and maintenance personnel to perform extra duties.This paper will describe a mechanical flushing system located in the confined space of the Outfall Structure. The mechanical flushing system was designed to store and release a large volume of wastewater to flush the twin river crossing with a high volume, high velocity stream while avoiding accidental releases of dry weather overflow to the river. The design also allows safe operation under extreme high flow conditions. The flushing system will be utilized during dry flow however; flows can increase rapidly thus requiring safe external operation.
The City of Richmond, Virginia is located at the head of tide on the James River. The older central part of the City is served by a combined sewer system (CSS) that comprises about 12,000 acres. The largest basin in the system is the Shockoe Creek Basin area that is comprised of about 8,000 acres, about 2/3 of the overall system. The City began addressing Combined Sewer Overflow (CSO) control in...
Author(s)
Wilbur E. McConicoKennis G. WootenGary A. DuValRonald E. BizzarriFederico E. MaischGeorge L. Guhse
SourceProceedings of the Water Environment Federation
SubjectSession 8 - Collection Systems Symposium: Operation and Maintenance – May the Flow Be with You
Document typeConference Paper
PublisherWater Environment Federation
Print publication date Jan, 2001
ISSN1938-6478
SICI1938-6478(20010101)2001:16L.642;1-
DOI10.2175/193864701790902077
Volume / Issue2001 / 16
Content sourceWEFTEC
First / last page(s)642 - 668
Copyright2001
Word count351

Purchase price $11.50

Get access
Log in Purchase content Purchase subscription
You may already have access to this content if you have previously purchased this content or have a subscription.
Need to create an account?

You can purchase access to this content but you might want to consider a subscription for a wide variety of items at a substantial discount!

Purchase access to 'Hydraulic Energy Flushing Of Inverted Siphons'

Add to cart
Purchase a subscription to gain access to 18,000+ Proceeding Papers, 25+ Fact Sheets, 20+ Technical Reports, 50+ magazine articles and select Technical Publications' chapters.
Loading items
There are no items to display at the moment.
Something went wrong trying to load these items.
Description: Book cover
Hydraulic Energy Flushing Of Inverted Siphons
Pricing
Non-member price: $11.50
Member price:
-288249
Get access
-288249
Log in Purchase content Purchase subscription
You may already have access to this content if you have previously purchased this content or have a subscription.
Need to create an account?

You can purchase access to this content but you might want to consider a subscription for a wide variety of items at a substantial discount!

Purchase access to 'Hydraulic Energy Flushing Of Inverted Siphons'

Add to cart
Purchase a subscription to gain access to 18,000+ Proceeding Papers, 25+ Fact Sheets, 20+ Technical Reports, 50+ magazine articles and select Technical Publications' chapters.

Details

Description: Book cover
Hydraulic Energy Flushing Of Inverted Siphons
Abstract
The City of Richmond, Virginia is located at the head of tide on the James River. The older central part of the City is served by a combined sewer system (CSS) that comprises about 12,000 acres. The largest basin in the system is the Shockoe Creek Basin area that is comprised of about 8,000 acres, about 2/3 of the overall system. The City began addressing Combined Sewer Overflow (CSO) control in the late 1970s by constructing a 38 million gallon “first flush” retention system on the Shockoe Creek Basin in the early 1980s. The Shockoe Creek Basin discharges into a diversion structure at the retention system through an arch sewer. A crest dam in the Outfall Structure, down stream of the Diversion Structure, prevents dry weather flow from overflowing into the river. Flows into this structure are transferred to the Wastewater Treatment Plant (WWTP), across the James River using two 66-inch inverted siphon pipelines. The siphons have a firm capacity of 200 mgd. Flows feeding the river crossing vary from a dry weather flow of approximately 30 mgd to a wet weather flow of about 60 mgd. These wet weather CSO flows are very turbulent and sediment laden. Wet weather CSO events after the winter driving season contribute large quantities of sand and grit. Over time, deposition of solids in the twin river crossing can reduce the flow capacity of the inverted siphons pipelines, reducing transfer capacity to the wastewater treatment plant. This plugging causes operations personnel to modify standard operating procedures and maintenance personnel to perform extra duties.This paper will describe a mechanical flushing system located in the confined space of the Outfall Structure. The mechanical flushing system was designed to store and release a large volume of wastewater to flush the twin river crossing with a high volume, high velocity stream while avoiding accidental releases of dry weather overflow to the river. The design also allows safe operation under extreme high flow conditions. The flushing system will be utilized during dry flow however; flows can increase rapidly thus requiring safe external operation.
The City of Richmond, Virginia is located at the head of tide on the James River. The older central part of the City is served by a combined sewer system (CSS) that comprises about 12,000 acres. The largest basin in the system is the Shockoe Creek Basin area that is comprised of about 8,000 acres, about 2/3 of the overall system. The City began addressing Combined Sewer Overflow (CSO) control in...
Author(s)
Wilbur E. McConicoKennis G. WootenGary A. DuValRonald E. BizzarriFederico E. MaischGeorge L. Guhse
SourceProceedings of the Water Environment Federation
SubjectSession 8 - Collection Systems Symposium: Operation and Maintenance – May the Flow Be with You
Document typeConference Paper
PublisherWater Environment Federation
Print publication date Jan, 2001
ISSN1938-6478
SICI1938-6478(20010101)2001:16L.642;1-
DOI10.2175/193864701790902077
Volume / Issue2001 / 16
Content sourceWEFTEC
First / last page(s)642 - 668
Copyright2001
Word count351

Actions, changes & tasks

Outstanding Actions

Add action for paragraph

Current Changes

Add signficant change

Current Tasks

Add risk task

Connect with us

Follow us on Facebook
Follow us on Twitter
Connect to us on LinkedIn
Subscribe on YouTube
Powered by Librios Ltd
Powered by Librios Ltd
Authors
Terms of Use
Policies
Help
Accessibility
Contact us
Copyright © 2024 by the Water Environment Federation
Loading items
There are no items to display at the moment.
Something went wrong trying to load these items.
Description: WWTF Digital Boot 180x150
WWTF Digital (180x150)
Created on Jul 02
Websitehttps:/­/­www.wef.org/­wwtf?utm_medium=WWTF&utm_source=AccessWater&utm_campaign=WWTF
180x150
Wilbur E. McConico# Kennis G. Wooten# Gary A. DuVal# Ronald E. Bizzarri# Federico E. Maisch# George L. Guhse. Hydraulic Energy Flushing Of Inverted Siphons. Alexandria, VA 22314-1994, USA: Water Environment Federation, 2018. Web. 29 Jun. 2025. <https://www.accesswater.org?id=-288249CITANCHOR>.
Wilbur E. McConico# Kennis G. Wooten# Gary A. DuVal# Ronald E. Bizzarri# Federico E. Maisch# George L. Guhse. Hydraulic Energy Flushing Of Inverted Siphons. Alexandria, VA 22314-1994, USA: Water Environment Federation, 2018. Accessed June 29, 2025. https://www.accesswater.org/?id=-288249CITANCHOR.
Wilbur E. McConico# Kennis G. Wooten# Gary A. DuVal# Ronald E. Bizzarri# Federico E. Maisch# George L. Guhse
Hydraulic Energy Flushing Of Inverted Siphons
Access Water
Water Environment Federation
December 22, 2018
June 29, 2025
https://www.accesswater.org/?id=-288249CITANCHOR