lastID = -288692
Skip to main content Skip to top navigation Skip to site search
Top of page
  • My citations options
    Web Back (from Web)
    Chicago Back (from Chicago)
    MLA Back (from MLA)
Close action menu

You need to login to use this feature.

Please wait a moment…
Please wait while we update your results...
Please wait a moment...
Loading icon
Description: Access Water
Context Menu
Description: Book cover
Long Term Performance of a Septic Tank - Rock Filter System
  • Browse
  • Compilations
    • Compilations list
  • Subscriptions
Tools

Related contents

Loading related content

Workflow

No linked records yet

X
  • Current: 2020-02-01 01:07:07 Administrator
  • 2020-02-01 01:07:06 Administrator
Description: Access Water
  • Browse
  • Compilations
  • Subscriptions
Log in
0
Accessibility Options

Base text size -

This is a sample piece of body text
Larger
Smaller
  • Shopping basket (0)
  • Accessibility options
  • Return to previous
Description: Book cover
Long Term Performance of a Septic Tank - Rock Filter System

Long Term Performance of a Septic Tank - Rock Filter System

Long Term Performance of a Septic Tank - Rock Filter System

  • New
  • View
  • Details
  • Reader
  • Default
  • Share
  • Email
  • Facebook
  • Twitter
  • LinkedIn
  • New
  • View
  • Default view
  • Reader view
  • Data view
  • Details

This page cannot be printed from here

Please use the dedicated print option from the 'view' drop down menu located in the blue ribbon in the top, right section of the publication.

screenshot of print menu option

Description: Book cover
Long Term Performance of a Septic Tank - Rock Filter System
Abstract
The overall performance of rock plant filters in Louisiana has been spotty at best. Previous investigations have found that most Louisiana facilities maintained little or no operational data on which to base rational judgments. This paper summarizes the performance of a septic tank – rock filter system at an interstate rest area on I-49 approximately 40 miles south of Alexandria, Louisiana. At present, treatment occurs in two cells, each 150' long by 30' wide, connected in series. The Louisiana Department of Transportation and Development (LADOTD) is using this facility to investigate whether subsurface flow technology might be a more economical and reliable means of treating waste from rest areas as opposed to existing mechanical systems in situations where flows are small and skilled operators are not available. Discharge limits for this facility are 45 mg/l of BOD and TSS. There is no nitrogen limitation at this time.The following data have been collected every other week since March of 1997 at five points throughout the system: biochemical oxygen demand (BOD), total suspended solids (TSS), total Kjeldahl nitrogen (TKN), ammonia (NH3), nitrate (NO3), pH, conductivity, dissolved oxygen (D.O.), temperature and fecal coliforms. Chemical oxygen demand (COD), total phosphorous (TP), volatile suspended solids (VSS) and carbonaceous oxygen demand (CBOD) tests are conducted periodically as are tests for selected metals and hydrocarbons.The facility is not maintenance free but requires essentially no proactive operation except for periodically adding chlorine tablets for disinfection. Maintenance requirements are minimal and can be performed by rest area personnel. The waste strength at this facility is higher than reported for other rest areas. Mean BOD and TSS concentrations of the waste entering the treatment facility are 521 and 682 mg/liter respectively. The mean BOD and TSS concentrations of the waste entering Cell 1 are 177 and 73 mg/liter respectively. The BOD loading to Cell 1 is substantially higher than the North American average.Mean effluent BOD and TSS levels from Cell 1 are 37 and 25 mg/liter. Corresponding values from Cell 2 are 20 and 20 mg/liter respectively. The last permit violation occurred in August 1998.
The overall performance of rock plant filters in Louisiana has been spotty at best. Previous investigations have found that most Louisiana facilities maintained little or no operational data on which to base rational judgments. This paper summarizes the performance of a septic tank – rock filter system at an interstate rest area on I-49 approximately 40 miles south of Alexandria, Louisiana....
Author(s)
D. M. GriffinX. YanH. XiangC FletcherR. Crawford
SourceProceedings of the Water Environment Federation
SubjectSession 74 - Small Community and Natural Treatment Systems: Small Communities II
Document typeConference Paper
PublisherWater Environment Federation
Print publication date Jan, 2002
ISSN1938-6478
SICI1938-6478(20020101)2002:10L.111;1-
DOI10.2175/193864702784164721
Volume / Issue2002 / 10
Content sourceWEFTEC
First / last page(s)111 - 122
Copyright2002
Word count356

Purchase price $11.50

Get access
Log in Purchase content Purchase subscription
You may already have access to this content if you have previously purchased this content or have a subscription.
Need to create an account?

You can purchase access to this content but you might want to consider a subscription for a wide variety of items at a substantial discount!

Purchase access to 'Long Term Performance of a Septic Tank - Rock Filter System'

Add to cart
Purchase a subscription to gain access to 18,000+ Proceeding Papers, 25+ Fact Sheets, 20+ Technical Reports, 50+ magazine articles and select Technical Publications' chapters.
Loading items
There are no items to display at the moment.
Something went wrong trying to load these items.
Description: Book cover
Long Term Performance of a Septic Tank - Rock Filter System
Pricing
Non-member price: $11.50
Member price:
-288692
Get access
-288692
Log in Purchase content Purchase subscription
You may already have access to this content if you have previously purchased this content or have a subscription.
Need to create an account?

You can purchase access to this content but you might want to consider a subscription for a wide variety of items at a substantial discount!

Purchase access to 'Long Term Performance of a Septic Tank - Rock Filter System'

Add to cart
Purchase a subscription to gain access to 18,000+ Proceeding Papers, 25+ Fact Sheets, 20+ Technical Reports, 50+ magazine articles and select Technical Publications' chapters.

Details

Description: Book cover
Long Term Performance of a Septic Tank - Rock Filter System
Abstract
The overall performance of rock plant filters in Louisiana has been spotty at best. Previous investigations have found that most Louisiana facilities maintained little or no operational data on which to base rational judgments. This paper summarizes the performance of a septic tank – rock filter system at an interstate rest area on I-49 approximately 40 miles south of Alexandria, Louisiana. At present, treatment occurs in two cells, each 150' long by 30' wide, connected in series. The Louisiana Department of Transportation and Development (LADOTD) is using this facility to investigate whether subsurface flow technology might be a more economical and reliable means of treating waste from rest areas as opposed to existing mechanical systems in situations where flows are small and skilled operators are not available. Discharge limits for this facility are 45 mg/l of BOD and TSS. There is no nitrogen limitation at this time.The following data have been collected every other week since March of 1997 at five points throughout the system: biochemical oxygen demand (BOD), total suspended solids (TSS), total Kjeldahl nitrogen (TKN), ammonia (NH3), nitrate (NO3), pH, conductivity, dissolved oxygen (D.O.), temperature and fecal coliforms. Chemical oxygen demand (COD), total phosphorous (TP), volatile suspended solids (VSS) and carbonaceous oxygen demand (CBOD) tests are conducted periodically as are tests for selected metals and hydrocarbons.The facility is not maintenance free but requires essentially no proactive operation except for periodically adding chlorine tablets for disinfection. Maintenance requirements are minimal and can be performed by rest area personnel. The waste strength at this facility is higher than reported for other rest areas. Mean BOD and TSS concentrations of the waste entering the treatment facility are 521 and 682 mg/liter respectively. The mean BOD and TSS concentrations of the waste entering Cell 1 are 177 and 73 mg/liter respectively. The BOD loading to Cell 1 is substantially higher than the North American average.Mean effluent BOD and TSS levels from Cell 1 are 37 and 25 mg/liter. Corresponding values from Cell 2 are 20 and 20 mg/liter respectively. The last permit violation occurred in August 1998.
The overall performance of rock plant filters in Louisiana has been spotty at best. Previous investigations have found that most Louisiana facilities maintained little or no operational data on which to base rational judgments. This paper summarizes the performance of a septic tank – rock filter system at an interstate rest area on I-49 approximately 40 miles south of Alexandria, Louisiana....
Author(s)
D. M. GriffinX. YanH. XiangC FletcherR. Crawford
SourceProceedings of the Water Environment Federation
SubjectSession 74 - Small Community and Natural Treatment Systems: Small Communities II
Document typeConference Paper
PublisherWater Environment Federation
Print publication date Jan, 2002
ISSN1938-6478
SICI1938-6478(20020101)2002:10L.111;1-
DOI10.2175/193864702784164721
Volume / Issue2002 / 10
Content sourceWEFTEC
First / last page(s)111 - 122
Copyright2002
Word count356

Actions, changes & tasks

Outstanding Actions

Add action for paragraph

Current Changes

Add signficant change

Current Tasks

Add risk task

Connect with us

Follow us on Facebook
Follow us on Twitter
Connect to us on LinkedIn
Subscribe on YouTube
Powered by Librios Ltd
Powered by Librios Ltd
Authors
Terms of Use
Policies
Help
Accessibility
Contact us
Copyright © 2025 by the Water Environment Federation
Loading items
There are no items to display at the moment.
Something went wrong trying to load these items.
Description: WWTF Digital Boot 180x150
WWTF Digital (180x150)
Created on Jul 02
Websitehttps:/­/­www.wef.org/­wwtf?utm_medium=WWTF&utm_source=AccessWater&utm_campaign=WWTF
180x150
D. M. Griffin# X. Yan# H. Xiang# C Fletcher# R. Crawford. Long Term Performance of a Septic Tank - Rock Filter System. Alexandria, VA 22314-1994, USA: Water Environment Federation, 2018. Web. 22 Oct. 2025. <https://www.accesswater.org?id=-288692CITANCHOR>.
D. M. Griffin# X. Yan# H. Xiang# C Fletcher# R. Crawford. Long Term Performance of a Septic Tank - Rock Filter System. Alexandria, VA 22314-1994, USA: Water Environment Federation, 2018. Accessed October 22, 2025. https://www.accesswater.org/?id=-288692CITANCHOR.
D. M. Griffin# X. Yan# H. Xiang# C Fletcher# R. Crawford
Long Term Performance of a Septic Tank - Rock Filter System
Access Water
Water Environment Federation
December 22, 2018
October 22, 2025
https://www.accesswater.org/?id=-288692CITANCHOR