lastID = -288925
Skip to main content Skip to top navigation Skip to site search
Top of page
  • My citations options
    Web Back (from Web)
    Chicago Back (from Chicago)
    MLA Back (from MLA)
Close action menu

You need to login to use this feature.

Please wait a moment…
Please wait while we update your results...
Please wait a moment...
Description: Access Water
Context Menu
Description: Book cover
ASSESSING THE EFFECTIVENESS OF SEWER HEADSPACE FOUL AIR EXTRACTION
  • Browse
  • Compilations
    • Compilations list
  • Subscriptions
Tools

Related contents

Loading related content

Workflow

No linked records yet

X
  • Current: 2022-05-06 11:29:06 Adam Phillips
  • 2022-05-06 11:29:05 Adam Phillips
  • 2020-01-31 19:55:46 Administrator
  • 2020-01-31 19:55:45 Administrator
Description: Access Water
  • Browse
  • Compilations
  • Subscriptions
Log in
0
Accessibility Options

Base text size -

This is a sample piece of body text
Larger
Smaller
  • Shopping basket (0)
  • Accessibility options
  • Return to previous
Description: Book cover
ASSESSING THE EFFECTIVENESS OF SEWER HEADSPACE FOUL AIR EXTRACTION

ASSESSING THE EFFECTIVENESS OF SEWER HEADSPACE FOUL AIR EXTRACTION

ASSESSING THE EFFECTIVENESS OF SEWER HEADSPACE FOUL AIR EXTRACTION

  • New
  • View
  • Details
  • Reader
  • Default
  • Share
  • Email
  • Facebook
  • Twitter
  • LinkedIn
  • New
  • View
  • Default view
  • Reader view
  • Data view
  • Details

This page cannot be printed from here

Please use the dedicated print option from the 'view' drop down menu located in the blue ribbon in the top, right section of the publication.

screenshot of print menu option

Description: Book cover
ASSESSING THE EFFECTIVENESS OF SEWER HEADSPACE FOUL AIR EXTRACTION
Abstract
Several large diameter interceptors in the metropolitan Phoenix area exhibit hydrogen sulfide concentrations in excess of 100 parts per million (ppm) in the headspace of the sewer. Additionally, wastewater velocity is relatively fast, causing liquid-induced airflow and air pressurization in the sewer headspace. Chemical odor control treatments and sealing manhole covers has only been partially effective in controlling fugitive odor emissions into commercial and residential areas near these interceptors.The Sub-Regional Operating Group (SROG – representing five cities in the Phoenix area) initiated a project to test air extraction from the sewer headspace with the long-range goal of installing several air treatment systems along odorous interceptors. The foul air extraction tests were conducted with a mobile, trailer-mounted fan and variable speed motor, with a flexible duct hose connected to a sheetmetal manhole adapter. Tests were conducted on three sections of interceptor ranging from 42- to 90-inch diameter. Airflow extracted from the sewers ranged from 2,700 cubic feet per minute (cfm) to 5,200 cfm.The sewers tested typically exhibit pressures between +0.10 and +0.25 inches water column (w.c). The extraction tests successfully reversed this pressure so that sewer headspaces were under negative pressures ranging from −0.03 to -.80 inches w.c. The magnitude of negative pressure diminished as distance from the foul air extraction point increased. The distance from the extraction point in which sewer headspace pressure was influenced was typically about 5 miles. However, major sewer junction structures limited the extent of pressure influence.Hydrogen sulfide (H2S) concentrations were continuously monitored and data-logged before, during, and after the extraction tests. This data indicated that H2S concentrations were routinely between 50 and 200 parts per million (ppm) and were not reduced significantly by forced ventilation of the sewer headspace.
Several large diameter interceptors in the metropolitan Phoenix area exhibit hydrogen sulfide concentrations in excess of 100 parts per million (ppm) in the headspace of the sewer. Additionally, wastewater velocity is relatively fast, causing liquid-induced airflow and air pressurization in the sewer headspace. Chemical odor control treatments and sealing manhole covers has only been partially...
Author(s)
Steve DavidsonJerry GreenJohn MannEd Lamb
SourceProceedings of the Water Environment Federation
SubjectSession 34 - Management of Odors and VOCs: Odors and VOCs II
Document typeConference Paper
PublisherWater Environment Federation
Print publication date Jan, 2002
ISSN1938-6478
SICI1938-6478(20020101)2002:14L.231;1-
DOI10.2175/193864702784248449
Volume / Issue2002 / 14
Content sourceWEFTEC
First / last page(s)231 - 245
Copyright2002
Word count292

Purchase price $11.50

Get access
Log in Purchase content Purchase subscription
You may already have access to this content if you have previously purchased this content or have a subscription.
Need to create an account?

You can purchase access to this content but you might want to consider a subscription for a wide variety of items at a substantial discount!

Purchase access to 'ASSESSING THE EFFECTIVENESS OF SEWER HEADSPACE FOUL AIR EXTRACTION'

Add to cart
Purchase a subscription to gain access to 18,000+ Proceeding Papers, 25+ Fact Sheets, 20+ Technical Reports, 50+ magazine articles and select Technical Publications' chapters.
Loading items
There are no items to display at the moment.
Something went wrong trying to load these items.
Description: Book cover
ASSESSING THE EFFECTIVENESS OF SEWER HEADSPACE FOUL AIR EXTRACTION
Pricing
Non-member price: $11.50
Member price:
-288925
Get access
-288925
Log in Purchase content Purchase subscription
You may already have access to this content if you have previously purchased this content or have a subscription.
Need to create an account?

You can purchase access to this content but you might want to consider a subscription for a wide variety of items at a substantial discount!

Purchase access to 'ASSESSING THE EFFECTIVENESS OF SEWER HEADSPACE FOUL AIR EXTRACTION'

Add to cart
Purchase a subscription to gain access to 18,000+ Proceeding Papers, 25+ Fact Sheets, 20+ Technical Reports, 50+ magazine articles and select Technical Publications' chapters.

Details

Description: Book cover
ASSESSING THE EFFECTIVENESS OF SEWER HEADSPACE FOUL AIR EXTRACTION
Abstract
Several large diameter interceptors in the metropolitan Phoenix area exhibit hydrogen sulfide concentrations in excess of 100 parts per million (ppm) in the headspace of the sewer. Additionally, wastewater velocity is relatively fast, causing liquid-induced airflow and air pressurization in the sewer headspace. Chemical odor control treatments and sealing manhole covers has only been partially effective in controlling fugitive odor emissions into commercial and residential areas near these interceptors.The Sub-Regional Operating Group (SROG – representing five cities in the Phoenix area) initiated a project to test air extraction from the sewer headspace with the long-range goal of installing several air treatment systems along odorous interceptors. The foul air extraction tests were conducted with a mobile, trailer-mounted fan and variable speed motor, with a flexible duct hose connected to a sheetmetal manhole adapter. Tests were conducted on three sections of interceptor ranging from 42- to 90-inch diameter. Airflow extracted from the sewers ranged from 2,700 cubic feet per minute (cfm) to 5,200 cfm.The sewers tested typically exhibit pressures between +0.10 and +0.25 inches water column (w.c). The extraction tests successfully reversed this pressure so that sewer headspaces were under negative pressures ranging from −0.03 to -.80 inches w.c. The magnitude of negative pressure diminished as distance from the foul air extraction point increased. The distance from the extraction point in which sewer headspace pressure was influenced was typically about 5 miles. However, major sewer junction structures limited the extent of pressure influence.Hydrogen sulfide (H2S) concentrations were continuously monitored and data-logged before, during, and after the extraction tests. This data indicated that H2S concentrations were routinely between 50 and 200 parts per million (ppm) and were not reduced significantly by forced ventilation of the sewer headspace.
Several large diameter interceptors in the metropolitan Phoenix area exhibit hydrogen sulfide concentrations in excess of 100 parts per million (ppm) in the headspace of the sewer. Additionally, wastewater velocity is relatively fast, causing liquid-induced airflow and air pressurization in the sewer headspace. Chemical odor control treatments and sealing manhole covers has only been partially...
Author(s)
Steve DavidsonJerry GreenJohn MannEd Lamb
SourceProceedings of the Water Environment Federation
SubjectSession 34 - Management of Odors and VOCs: Odors and VOCs II
Document typeConference Paper
PublisherWater Environment Federation
Print publication date Jan, 2002
ISSN1938-6478
SICI1938-6478(20020101)2002:14L.231;1-
DOI10.2175/193864702784248449
Volume / Issue2002 / 14
Content sourceWEFTEC
First / last page(s)231 - 245
Copyright2002
Word count292

Actions, changes & tasks

Outstanding Actions

Add action for paragraph

Current Changes

Add signficant change

Current Tasks

Add risk task

Connect with us

Follow us on Facebook
Follow us on Twitter
Connect to us on LinkedIn
Subscribe on YouTube
Powered by Librios Ltd
Powered by Librios Ltd
Authors
Terms of Use
Policies
Help
Accessibility
Contact us
Copyright © 2024 by the Water Environment Federation
Loading items
There are no items to display at the moment.
Something went wrong trying to load these items.
Description: WWTF Digital Boot 180x150
WWTF Digital (180x150)
Created on Jul 02
Websitehttps:/­/­www.wef.org/­wwtf?utm_medium=WWTF&utm_source=AccessWater&utm_campaign=WWTF
180x150
Steve Davidson# Jerry Green# John Mann# Ed Lamb. ASSESSING THE EFFECTIVENESS OF SEWER HEADSPACE FOUL AIR EXTRACTION. Alexandria, VA 22314-1994, USA: Water Environment Federation, 2018. Web. 12 Jun. 2025. <https://www.accesswater.org?id=-288925CITANCHOR>.
Steve Davidson# Jerry Green# John Mann# Ed Lamb. ASSESSING THE EFFECTIVENESS OF SEWER HEADSPACE FOUL AIR EXTRACTION. Alexandria, VA 22314-1994, USA: Water Environment Federation, 2018. Accessed June 12, 2025. https://www.accesswater.org/?id=-288925CITANCHOR.
Steve Davidson# Jerry Green# John Mann# Ed Lamb
ASSESSING THE EFFECTIVENESS OF SEWER HEADSPACE FOUL AIR EXTRACTION
Access Water
Water Environment Federation
December 22, 2018
June 12, 2025
https://www.accesswater.org/?id=-288925CITANCHOR