lastID = -289442
Skip to main content Skip to top navigation Skip to site search
Top of page
  • My citations options
    Web Back (from Web)
    Chicago Back (from Chicago)
    MLA Back (from MLA)
Close action menu

You need to login to use this feature.

Please wait a moment…
Please wait while we update your results...
Please wait a moment...
Description: Access Water
Context Menu
Description: Book cover
ODOR TESTING BIOSOLIDS FOR DECISION MAKING
  • Browse
  • Compilations
    • Compilations list
  • Subscriptions
Tools

Related contents

Loading related content

Workflow

No linked records yet

X
  • Current: 2022-05-04 15:20:06 Adam Phillips
  • 2020-03-27 00:53:53 Adam Phillips
  • 2020-02-01 02:18:10 Administrator
  • 2020-02-01 02:18:09 Administrator
Description: Access Water
  • Browse
  • Compilations
  • Subscriptions
Log in
0
Accessibility Options

Base text size -

This is a sample piece of body text
Larger
Smaller
  • Shopping basket (0)
  • Accessibility options
  • Return to previous
Description: Book cover
ODOR TESTING BIOSOLIDS FOR DECISION MAKING

ODOR TESTING BIOSOLIDS FOR DECISION MAKING

ODOR TESTING BIOSOLIDS FOR DECISION MAKING

  • New
  • View
  • Details
  • Reader
  • Default
  • Share
  • Email
  • Facebook
  • Twitter
  • LinkedIn
  • New
  • View
  • Default view
  • Reader view
  • Data view
  • Details

This page cannot be printed from here

Please use the dedicated print option from the 'view' drop down menu located in the blue ribbon in the top, right section of the publication.

screenshot of print menu option

Description: Book cover
ODOR TESTING BIOSOLIDS FOR DECISION MAKING
Abstract
The measurement of odors from wastewater treatment facilities is usually a requirement for compliance monitoring, planning, site expansion, and review of operational practices. These odor measurements are often focused on the “front end” of the facility, i.e. head works, primaries, and aeration processes. Sometimes attention is also placed on digesters and dewatering processes. However, the odor of the biosolids material is often overlooked as a parameter in decision-making at the wastewater treatment facility.Odor is a serious issue in the acceptance of biosolids at a landfill and, more so, a critical issue in public acceptance for land application of biosolids. The biosolids industry recognizes a wide variability in the odor from different biosolids. In the search for operational parameters that influence biosolids odor, the need to select and trust odor measurement methods is critical.Research on biosolids odor includes identifying the origin, mechanisms, and parameters for odor production, quantifying odor generation, defining “low odor” processes, and measuring odor in the ambient air surrounding land application operations. All of these research objectives need common, standard, and trustworthy “odor testing” methods (standard practices). Equally important to defining and accepting standard methods, is the over riding need to understand the odor testing results for decision making within the Environmental Management System.Odors have measurable parameters that are not always understood. The parameters of odor include: “odor concentration” (thresholds), “odor intensity” (intensity referencing), “odor character” (standard descriptors), “odor persistency” (the “hang time” of the odor), and “odor Hedonic Tone” (subjective measure of pleasantness/unpleasantness). Each of these parameters have certain limits of “accuracy” that must be understood for appropriate decision making. Without consideration for parameter variability, two odor test results may appear to be different, but may not be statistically different. Likewise, two odor test results may appear to be “nearly the same”, but the differences may be significant when all the odor parameter results are presented in combination for decision-making. Biosolids odors need to be tested with reference to the facility's processes and with reference to the environmental situations at the time of land application.
The measurement of odors from wastewater treatment facilities is usually a requirement for compliance monitoring, planning, site expansion, and review of operational practices. These odor measurements are often focused on the “front end” of the facility, i.e. head works, primaries, and aeration processes. Sometimes attention is also placed on digesters and dewatering processes....
Author(s)
Charles M. McGinleyMichael A. McGinley
SourceProceedings of the Water Environment Federation
SubjectSession 18: Odor Control for Biosolids
Document typeConference Paper
PublisherWater Environment Federation
Print publication date Jan, 2002
ISSN1938-6478
SICI1938-6478(20020101)2002:3L.1055;1-
DOI10.2175/193864702785302456
Volume / Issue2002 / 3
Content sourceResiduals and Biosolids Conference
First / last page(s)1055 - 1072
Copyright2002
Word count344

Purchase price $11.50

Get access
Log in Purchase content Purchase subscription
You may already have access to this content if you have previously purchased this content or have a subscription.
Need to create an account?

You can purchase access to this content but you might want to consider a subscription for a wide variety of items at a substantial discount!

Purchase access to 'ODOR TESTING BIOSOLIDS FOR DECISION MAKING'

Add to cart
Purchase a subscription to gain access to 18,000+ Proceeding Papers, 25+ Fact Sheets, 20+ Technical Reports, 50+ magazine articles and select Technical Publications' chapters.
Loading items
There are no items to display at the moment.
Something went wrong trying to load these items.
Description: Book cover
ODOR TESTING BIOSOLIDS FOR DECISION MAKING
Pricing
Non-member price: $11.50
Member price:
-289442
Get access
-289442
Log in Purchase content Purchase subscription
You may already have access to this content if you have previously purchased this content or have a subscription.
Need to create an account?

You can purchase access to this content but you might want to consider a subscription for a wide variety of items at a substantial discount!

Purchase access to 'ODOR TESTING BIOSOLIDS FOR DECISION MAKING'

Add to cart
Purchase a subscription to gain access to 18,000+ Proceeding Papers, 25+ Fact Sheets, 20+ Technical Reports, 50+ magazine articles and select Technical Publications' chapters.

Details

Description: Book cover
ODOR TESTING BIOSOLIDS FOR DECISION MAKING
Abstract
The measurement of odors from wastewater treatment facilities is usually a requirement for compliance monitoring, planning, site expansion, and review of operational practices. These odor measurements are often focused on the “front end” of the facility, i.e. head works, primaries, and aeration processes. Sometimes attention is also placed on digesters and dewatering processes. However, the odor of the biosolids material is often overlooked as a parameter in decision-making at the wastewater treatment facility.Odor is a serious issue in the acceptance of biosolids at a landfill and, more so, a critical issue in public acceptance for land application of biosolids. The biosolids industry recognizes a wide variability in the odor from different biosolids. In the search for operational parameters that influence biosolids odor, the need to select and trust odor measurement methods is critical.Research on biosolids odor includes identifying the origin, mechanisms, and parameters for odor production, quantifying odor generation, defining “low odor” processes, and measuring odor in the ambient air surrounding land application operations. All of these research objectives need common, standard, and trustworthy “odor testing” methods (standard practices). Equally important to defining and accepting standard methods, is the over riding need to understand the odor testing results for decision making within the Environmental Management System.Odors have measurable parameters that are not always understood. The parameters of odor include: “odor concentration” (thresholds), “odor intensity” (intensity referencing), “odor character” (standard descriptors), “odor persistency” (the “hang time” of the odor), and “odor Hedonic Tone” (subjective measure of pleasantness/unpleasantness). Each of these parameters have certain limits of “accuracy” that must be understood for appropriate decision making. Without consideration for parameter variability, two odor test results may appear to be different, but may not be statistically different. Likewise, two odor test results may appear to be “nearly the same”, but the differences may be significant when all the odor parameter results are presented in combination for decision-making. Biosolids odors need to be tested with reference to the facility's processes and with reference to the environmental situations at the time of land application.
The measurement of odors from wastewater treatment facilities is usually a requirement for compliance monitoring, planning, site expansion, and review of operational practices. These odor measurements are often focused on the “front end” of the facility, i.e. head works, primaries, and aeration processes. Sometimes attention is also placed on digesters and dewatering processes....
Author(s)
Charles M. McGinleyMichael A. McGinley
SourceProceedings of the Water Environment Federation
SubjectSession 18: Odor Control for Biosolids
Document typeConference Paper
PublisherWater Environment Federation
Print publication date Jan, 2002
ISSN1938-6478
SICI1938-6478(20020101)2002:3L.1055;1-
DOI10.2175/193864702785302456
Volume / Issue2002 / 3
Content sourceResiduals and Biosolids Conference
First / last page(s)1055 - 1072
Copyright2002
Word count344

Actions, changes & tasks

Outstanding Actions

Add action for paragraph

Current Changes

Add signficant change

Current Tasks

Add risk task

Connect with us

Follow us on Facebook
Follow us on Twitter
Connect to us on LinkedIn
Subscribe on YouTube
Powered by Librios Ltd
Powered by Librios Ltd
Authors
Terms of Use
Policies
Help
Accessibility
Contact us
Copyright © 2024 by the Water Environment Federation
Loading items
There are no items to display at the moment.
Something went wrong trying to load these items.
Description: WWTF Digital Boot 180x150
WWTF Digital (180x150)
Created on Jul 02
Websitehttps:/­/­www.wef.org/­wwtf?utm_medium=WWTF&utm_source=AccessWater&utm_campaign=WWTF
180x150
Charles M. McGinley# Michael A. McGinley. ODOR TESTING BIOSOLIDS FOR DECISION MAKING. Alexandria, VA 22314-1994, USA: Water Environment Federation, 2018. Web. 4 Jul. 2025. <https://www.accesswater.org?id=-289442CITANCHOR>.
Charles M. McGinley# Michael A. McGinley. ODOR TESTING BIOSOLIDS FOR DECISION MAKING. Alexandria, VA 22314-1994, USA: Water Environment Federation, 2018. Accessed July 4, 2025. https://www.accesswater.org/?id=-289442CITANCHOR.
Charles M. McGinley# Michael A. McGinley
ODOR TESTING BIOSOLIDS FOR DECISION MAKING
Access Water
Water Environment Federation
December 22, 2018
July 4, 2025
https://www.accesswater.org/?id=-289442CITANCHOR