lastID = -289550
Skip to main content Skip to top navigation Skip to site search
Top of page
  • My citations options
    Web Back (from Web)
    Chicago Back (from Chicago)
    MLA Back (from MLA)
Close action menu

You need to login to use this feature.

Please wait a moment…
Please wait while we update your results...
Please wait a moment...
Description: Access Water
Context Menu
Description: Book cover
THEORETICAL AND PRACTICAL CONSIDERATIONS IN THE USE OF WIND TUNNELS FOR ODOR EMISSION MEASUREMENT
  • Browse
  • Compilations
    • Compilations list
  • Subscriptions
Tools

Related contents

Loading related content

Workflow

No linked records yet

X
  • Current: 2020-03-27 00:07:01 Adam Phillips
  • 2020-02-01 05:37:02 Administrator
  • 2020-02-01 05:37:01 Administrator
Description: Access Water
  • Browse
  • Compilations
  • Subscriptions
Log in
0
Accessibility Options

Base text size -

This is a sample piece of body text
Larger
Smaller
  • Shopping basket (0)
  • Accessibility options
  • Return to previous
Description: Book cover
THEORETICAL AND PRACTICAL CONSIDERATIONS IN THE USE OF WIND TUNNELS FOR ODOR EMISSION MEASUREMENT

THEORETICAL AND PRACTICAL CONSIDERATIONS IN THE USE OF WIND TUNNELS FOR ODOR EMISSION MEASUREMENT

THEORETICAL AND PRACTICAL CONSIDERATIONS IN THE USE OF WIND TUNNELS FOR ODOR EMISSION MEASUREMENT

  • New
  • View
  • Details
  • Reader
  • Default
  • Share
  • Email
  • Facebook
  • Twitter
  • LinkedIn
  • New
  • View
  • Default view
  • Reader view
  • Data view
  • Details

This page cannot be printed from here

Please use the dedicated print option from the 'view' drop down menu located in the blue ribbon in the top, right section of the publication.

screenshot of print menu option

Description: Book cover
THEORETICAL AND PRACTICAL CONSIDERATIONS IN THE USE OF WIND TUNNELS FOR ODOR EMISSION MEASUREMENT
Abstract
In past decades, wind tunnel systems have been commonly used for aerodynamic research, including simulation of wind loads on buildings, automobiles, and airplanes. In recent years, this methodology has been used to measure odor emission rates from area sources such as primary sedimentation tanks at sewage treatment plants. The size of the wind tunnel used for this purpose is much smaller than conventional wind tunnels. Emission rates obtained from such measurements have reportedly differed by up to 300 times, compared to the conventional flux chamber sampling method. Thus, it is important to provide a review of the system.This paper presents the basic principles and theories used in a conventional wind tunnel, and discusses how these principles and theories pertain to a small-scale wind tunnel system. While basic theories may generally apply to a small wind tunnel system, some limitations exist that may cause errors in odor emission rate measurements, especially under field conditions. Moreover, deployment of wind tunnel system onto a moving area surface may upset the development of boundary layers in the system, leading to erroneous measurement of odor emission rates.A lack of understanding of the effect of upward rising air bubbles on the dynamics of flow in wind tunnels limits the application of wind tunnels for area sources with outward flows, such as aerated area sources. High detection limits of wind tunnel systems also pose a problem in measuring odor emission rates from area sources with low odor emissions.This paper also compares wind tunnel and flux chamber technologies. Compared to a flux chamber, wind tunnel technology is not as commonly used worldwide. Although wind tunnels may be used to simulate emissions under normal ambient conditions with results that are scaleable, no clear documentation has been provided for these adjustments. There is also a general lack of information and documentation on issues regarding the sampling protocol for a wind tunnel system, and insufficient peer-reviewed papers that support the accuracy or recovery rates of the system.Field measurements have revealed that the results obtained using a wind tunnel were much higher than those obtained with a flux chamber. During the sampling session, observers noted that the inside of the wind tunnel underwent a wave condition. This artificial wave condition may bias the measured odor fluxes and yield results that are upward relative to those measured by a flux chamber.Practical issues are also considered and discussed in this paper. Deployment of wind tunnel sampling systems involves the use of bulky and cumbersome equipment and accessories. Some accessories are also heavy. These conditions may require additional time for system assembly and additional manpower for equipment handling. Therefore, the cost effectiveness of the technology becomes an important issue that must be considered before deploying this technology for odor sampling and emission measurement.
In past decades, wind tunnel systems have been commonly used for aerodynamic research, including simulation of wind loads on buildings, automobiles, and airplanes. In recent years, this methodology has been used to measure odor emission rates from area sources such as primary sedimentation tanks at sewage treatment plants. The size of the wind tunnel used for this purpose is much smaller than...
Author(s)
Jay WitherspoonLawrence KoeYih-Ming KohYan WuChuck SchmidtTom Card
SourceProceedings of the Water Environment Federation
SubjectSession 7 Methods for Sampling, Measuring, and Estimating Emissions II
Document typeConference Paper
PublisherWater Environment Federation
Print publication date Jan, 2002
ISSN1938-6478
SICI1938-6478(20020101)2002:5L.566;1-
DOI10.2175/193864702785140401
Volume / Issue2002 / 5
Content sourceOdors and Air Pollutants Conference
First / last page(s)566 - 578
Copyright2002
Word count472

Purchase price $11.50

Get access
Log in Purchase content Purchase subscription
You may already have access to this content if you have previously purchased this content or have a subscription.
Need to create an account?

You can purchase access to this content but you might want to consider a subscription for a wide variety of items at a substantial discount!

Purchase access to 'THEORETICAL AND PRACTICAL CONSIDERATIONS IN THE USE OF WIND TUNNELS FOR ODOR EMISSION MEASUREMENT'

Add to cart
Purchase a subscription to gain access to 18,000+ Proceeding Papers, 25+ Fact Sheets, 20+ Technical Reports, 50+ magazine articles and select Technical Publications' chapters.
Loading items
There are no items to display at the moment.
Something went wrong trying to load these items.
Description: Book cover
THEORETICAL AND PRACTICAL CONSIDERATIONS IN THE USE OF WIND TUNNELS FOR ODOR EMISSION MEASUREMENT
Pricing
Non-member price: $11.50
Member price:
-289550
Get access
-289550
Log in Purchase content Purchase subscription
You may already have access to this content if you have previously purchased this content or have a subscription.
Need to create an account?

You can purchase access to this content but you might want to consider a subscription for a wide variety of items at a substantial discount!

Purchase access to 'THEORETICAL AND PRACTICAL CONSIDERATIONS IN THE USE OF WIND TUNNELS FOR ODOR EMISSION MEASUREMENT'

Add to cart
Purchase a subscription to gain access to 18,000+ Proceeding Papers, 25+ Fact Sheets, 20+ Technical Reports, 50+ magazine articles and select Technical Publications' chapters.

Details

Description: Book cover
THEORETICAL AND PRACTICAL CONSIDERATIONS IN THE USE OF WIND TUNNELS FOR ODOR EMISSION MEASUREMENT
Abstract
In past decades, wind tunnel systems have been commonly used for aerodynamic research, including simulation of wind loads on buildings, automobiles, and airplanes. In recent years, this methodology has been used to measure odor emission rates from area sources such as primary sedimentation tanks at sewage treatment plants. The size of the wind tunnel used for this purpose is much smaller than conventional wind tunnels. Emission rates obtained from such measurements have reportedly differed by up to 300 times, compared to the conventional flux chamber sampling method. Thus, it is important to provide a review of the system.This paper presents the basic principles and theories used in a conventional wind tunnel, and discusses how these principles and theories pertain to a small-scale wind tunnel system. While basic theories may generally apply to a small wind tunnel system, some limitations exist that may cause errors in odor emission rate measurements, especially under field conditions. Moreover, deployment of wind tunnel system onto a moving area surface may upset the development of boundary layers in the system, leading to erroneous measurement of odor emission rates.A lack of understanding of the effect of upward rising air bubbles on the dynamics of flow in wind tunnels limits the application of wind tunnels for area sources with outward flows, such as aerated area sources. High detection limits of wind tunnel systems also pose a problem in measuring odor emission rates from area sources with low odor emissions.This paper also compares wind tunnel and flux chamber technologies. Compared to a flux chamber, wind tunnel technology is not as commonly used worldwide. Although wind tunnels may be used to simulate emissions under normal ambient conditions with results that are scaleable, no clear documentation has been provided for these adjustments. There is also a general lack of information and documentation on issues regarding the sampling protocol for a wind tunnel system, and insufficient peer-reviewed papers that support the accuracy or recovery rates of the system.Field measurements have revealed that the results obtained using a wind tunnel were much higher than those obtained with a flux chamber. During the sampling session, observers noted that the inside of the wind tunnel underwent a wave condition. This artificial wave condition may bias the measured odor fluxes and yield results that are upward relative to those measured by a flux chamber.Practical issues are also considered and discussed in this paper. Deployment of wind tunnel sampling systems involves the use of bulky and cumbersome equipment and accessories. Some accessories are also heavy. These conditions may require additional time for system assembly and additional manpower for equipment handling. Therefore, the cost effectiveness of the technology becomes an important issue that must be considered before deploying this technology for odor sampling and emission measurement.
In past decades, wind tunnel systems have been commonly used for aerodynamic research, including simulation of wind loads on buildings, automobiles, and airplanes. In recent years, this methodology has been used to measure odor emission rates from area sources such as primary sedimentation tanks at sewage treatment plants. The size of the wind tunnel used for this purpose is much smaller than...
Author(s)
Jay WitherspoonLawrence KoeYih-Ming KohYan WuChuck SchmidtTom Card
SourceProceedings of the Water Environment Federation
SubjectSession 7 Methods for Sampling, Measuring, and Estimating Emissions II
Document typeConference Paper
PublisherWater Environment Federation
Print publication date Jan, 2002
ISSN1938-6478
SICI1938-6478(20020101)2002:5L.566;1-
DOI10.2175/193864702785140401
Volume / Issue2002 / 5
Content sourceOdors and Air Pollutants Conference
First / last page(s)566 - 578
Copyright2002
Word count472

Actions, changes & tasks

Outstanding Actions

Add action for paragraph

Current Changes

Add signficant change

Current Tasks

Add risk task

Connect with us

Follow us on Facebook
Follow us on Twitter
Connect to us on LinkedIn
Subscribe on YouTube
Powered by Librios Ltd
Powered by Librios Ltd
Authors
Terms of Use
Policies
Help
Accessibility
Contact us
Copyright © 2024 by the Water Environment Federation
Loading items
There are no items to display at the moment.
Something went wrong trying to load these items.
Description: WWTF Digital Boot 180x150
WWTF Digital (180x150)
Created on Jul 02
Websitehttps:/­/­www.wef.org/­wwtf?utm_medium=WWTF&utm_source=AccessWater&utm_campaign=WWTF
180x150
Jay Witherspoon# Lawrence Koe# Yih-Ming Koh# Yan Wu# Chuck Schmidt# Tom Card. THEORETICAL AND PRACTICAL CONSIDERATIONS IN THE USE OF WIND TUNNELS FOR ODOR EMISSION MEASUREMENT. Alexandria, VA 22314-1994, USA: Water Environment Federation, 2018. Web. 2 Jul. 2025. <https://www.accesswater.org?id=-289550CITANCHOR>.
Jay Witherspoon# Lawrence Koe# Yih-Ming Koh# Yan Wu# Chuck Schmidt# Tom Card. THEORETICAL AND PRACTICAL CONSIDERATIONS IN THE USE OF WIND TUNNELS FOR ODOR EMISSION MEASUREMENT. Alexandria, VA 22314-1994, USA: Water Environment Federation, 2018. Accessed July 2, 2025. https://www.accesswater.org/?id=-289550CITANCHOR.
Jay Witherspoon# Lawrence Koe# Yih-Ming Koh# Yan Wu# Chuck Schmidt# Tom Card
THEORETICAL AND PRACTICAL CONSIDERATIONS IN THE USE OF WIND TUNNELS FOR ODOR EMISSION MEASUREMENT
Access Water
Water Environment Federation
December 22, 2018
July 2, 2025
https://www.accesswater.org/?id=-289550CITANCHOR