lastID = -289578
Skip to main content Skip to top navigation Skip to site search
Top of page
  • My citations options
    Web Back (from Web)
    Chicago Back (from Chicago)
    MLA Back (from MLA)
Close action menu

You need to login to use this feature.

Please wait a moment…
Please wait while we update your results...
Please wait a moment...
Description: Access Water
Context Menu
Description: Book cover
THREE-STEP PROCESS TO SUCCESS IN CONTROLLING WASTEWATER COLLECTION SYSTEM ODORS IN GASTONIA, NORTH CAROLINA
  • Browse
  • Compilations
    • Compilations list
  • Subscriptions
Tools

Related contents

Loading related content

Workflow

No linked records yet

X
  • Current: 2020-03-27 00:06:28 Adam Phillips
  • 2020-03-27 00:06:27 Adam Phillips
  • 2020-02-01 05:39:34 Administrator
  • 2020-02-01 05:39:33 Administrator
Description: Access Water
  • Browse
  • Compilations
  • Subscriptions
Log in
0
Accessibility Options

Base text size -

This is a sample piece of body text
Larger
Smaller
  • Shopping basket (0)
  • Accessibility options
  • Return to previous
Description: Book cover
THREE-STEP PROCESS TO SUCCESS IN CONTROLLING WASTEWATER COLLECTION SYSTEM ODORS IN GASTONIA, NORTH CAROLINA

THREE-STEP PROCESS TO SUCCESS IN CONTROLLING WASTEWATER COLLECTION SYSTEM ODORS IN GASTONIA, NORTH CAROLINA

THREE-STEP PROCESS TO SUCCESS IN CONTROLLING WASTEWATER COLLECTION SYSTEM ODORS IN GASTONIA, NORTH CAROLINA

  • New
  • View
  • Details
  • Reader
  • Default
  • Share
  • Email
  • Facebook
  • Twitter
  • LinkedIn
  • New
  • View
  • Default view
  • Reader view
  • Data view
  • Details

This page cannot be printed from here

Please use the dedicated print option from the 'view' drop down menu located in the blue ribbon in the top, right section of the publication.

screenshot of print menu option

Description: Book cover
THREE-STEP PROCESS TO SUCCESS IN CONTROLLING WASTEWATER COLLECTION SYSTEM ODORS IN GASTONIA, NORTH CAROLINA
Abstract
The City of Gastonia's municipal wastewater system serves a population exceeding 80,000, with a large industrial base that consumes over 40% of its total system capacity. The service area now covers more than 50 square miles, including most of Gaston County and extending beyond county borders into several surrounding counties as well as South Carolina. The City's wastewater collection system covers parts of three major drainage basins, which flow away from the city's center. The system consists of over 620 miles of collection lines and 12 pump stations. Recently one of the City's three wastewater treatment plants (WWTPs) was converted to a pump station. The wastewater from this pump station is conveyed via force main about two miles to the wet well of another major pump station. From the second pump station, wastewater is conveyed via force main about three miles to a manhole near the county hospital and a busy street. From that manhole, wastewater flows by gravity through a 48-inch interceptor to one of the City's two remaining WWTPs.Odor complaints related to the City's wastewater system had been infrequent until the pump station change, conveying wastewater from one basin in the city's system over 10 miles through two major interceptors and two force mains. Odor complaints increased dramatically from two neighborhoods close to the second pump station (now the City's largest). The addition of wastewater from the decommissioned WWTP and its longer residence time in the collection system were the likely causes. Odor complaints also increased from a commercial area near the force main discharge point from this pump station, and from a residential neighborhood surrounding the 48-inch interceptor that conveyed this wastewater to the WWTP.Three levels of odor control were implemented in response to the odor complaints:Liquid-phase treatment through the addition of chemicals and enzymes to the wastewater stream.Mechanical improvements to the major wastewater pump station.Vapor-phase treatment at strategic points in the system, via both chemical scrubbing and biofiltration.Several types of liquid-phase treatment were employed, including iron salts, a nitrate inhibitor, and a biological enzyme. The chemical that worked best was a combination of the three. For reasons of cost and effectiveness, however, liquid-phase treatment was not sufficient to reduce the odor complaints to an acceptable level.Several mechanical improvements to the City's largest wastewater pump station were made, including submergence of the force main discharge point, and installation of a submerged mechanical mixer to break up the wet-well scum layer. A third recommendation (variablespeed pumping) was not implemented due to cost. Submergence of the force-main discharge point and installation of the mixer resulted in reduction of odor complaints from the neighborhoods surrounding the pump station. The mixer installation paid for itself in less than two years by eliminating the City's need to remove the wet-well scum layer by vacuumtruck every two to three months. Odor complaints increased in the downstream neighborhoods, however, likely because of the increased organic load of the wastewater conveyed from the pump station as a result of the mixer installation.Even with the partial success of liquid-phase treatment and mechanical improvements, odor complaints continued to a point that the City decided to invest in the third level of vaporphase treatment. Three areas were selected for odor control, summarized below:The City's largest wastewater pump station (discussed above): Odor complaints had diminished but were still not down to an acceptable level, and the cost of liquid-phase treatment warranted installation of a vapor-phase system. Biofiltration was selected.The force-main discharge point from the above-mentioned pump station: Large amounts of hydrogen sulfide were released at this location due to exposure of the anaerobic wastewater to air at the force main discharge point, so a dry scrubber was recommended with its media targeted for hydrogen sulfide removal.A neighborhood surrounding the 48-inch interceptor on its way to the WWTP: Mercaptans were the prevalent odorant in this area, believed to be due to biological decay of the wastewater prompted by long residence time in the system. A dry scrubber was recommended, with its media targeted for mercaptans and total reduced sulfides.The vapor-phase odor control devices described above have been effective and resulted in a significant decrease in odor complaints.
The City of Gastonia's municipal wastewater system serves a population exceeding 80,000, with a large industrial base that consumes over 40% of its total system capacity. The service area now covers more than 50 square miles, including most of Gaston County and extending beyond county borders into several surrounding counties as well as South Carolina. The City's wastewater collection system...
Author(s)
Robert H. ForbesDavid HuxLarry CummingsSteven M. Goodwin
SourceProceedings of the Water Environment Federation
SubjectSession 2 Emissions from Collection and Conveyance Systems
Document typeConference Paper
PublisherWater Environment Federation
Print publication date Jan, 2002
ISSN1938-6478
SICI1938-6478(20020101)2002:5L.98;1-
DOI10.2175/193864702785140447
Volume / Issue2002 / 5
Content sourceOdors and Air Pollutants Conference
First / last page(s)98 - 108
Copyright2002
Word count709

Purchase price $11.50

Get access
Log in Purchase content Purchase subscription
You may already have access to this content if you have previously purchased this content or have a subscription.
Need to create an account?

You can purchase access to this content but you might want to consider a subscription for a wide variety of items at a substantial discount!

Purchase access to 'THREE-STEP PROCESS TO SUCCESS IN CONTROLLING WASTEWATER COLLECTION SYSTEM ODORS IN GASTONIA, NORTH CAROLINA'

Add to cart
Purchase a subscription to gain access to 18,000+ Proceeding Papers, 25+ Fact Sheets, 20+ Technical Reports, 50+ magazine articles and select Technical Publications' chapters.
Loading items
There are no items to display at the moment.
Something went wrong trying to load these items.
Description: Book cover
THREE-STEP PROCESS TO SUCCESS IN CONTROLLING WASTEWATER COLLECTION SYSTEM ODORS IN GASTONIA, NORTH CAROLINA
Pricing
Non-member price: $11.50
Member price:
-289578
Get access
-289578
Log in Purchase content Purchase subscription
You may already have access to this content if you have previously purchased this content or have a subscription.
Need to create an account?

You can purchase access to this content but you might want to consider a subscription for a wide variety of items at a substantial discount!

Purchase access to 'THREE-STEP PROCESS TO SUCCESS IN CONTROLLING WASTEWATER COLLECTION SYSTEM ODORS IN GASTONIA, NORTH CAROLINA'

Add to cart
Purchase a subscription to gain access to 18,000+ Proceeding Papers, 25+ Fact Sheets, 20+ Technical Reports, 50+ magazine articles and select Technical Publications' chapters.

Details

Description: Book cover
THREE-STEP PROCESS TO SUCCESS IN CONTROLLING WASTEWATER COLLECTION SYSTEM ODORS IN GASTONIA, NORTH CAROLINA
Abstract
The City of Gastonia's municipal wastewater system serves a population exceeding 80,000, with a large industrial base that consumes over 40% of its total system capacity. The service area now covers more than 50 square miles, including most of Gaston County and extending beyond county borders into several surrounding counties as well as South Carolina. The City's wastewater collection system covers parts of three major drainage basins, which flow away from the city's center. The system consists of over 620 miles of collection lines and 12 pump stations. Recently one of the City's three wastewater treatment plants (WWTPs) was converted to a pump station. The wastewater from this pump station is conveyed via force main about two miles to the wet well of another major pump station. From the second pump station, wastewater is conveyed via force main about three miles to a manhole near the county hospital and a busy street. From that manhole, wastewater flows by gravity through a 48-inch interceptor to one of the City's two remaining WWTPs.Odor complaints related to the City's wastewater system had been infrequent until the pump station change, conveying wastewater from one basin in the city's system over 10 miles through two major interceptors and two force mains. Odor complaints increased dramatically from two neighborhoods close to the second pump station (now the City's largest). The addition of wastewater from the decommissioned WWTP and its longer residence time in the collection system were the likely causes. Odor complaints also increased from a commercial area near the force main discharge point from this pump station, and from a residential neighborhood surrounding the 48-inch interceptor that conveyed this wastewater to the WWTP.Three levels of odor control were implemented in response to the odor complaints:Liquid-phase treatment through the addition of chemicals and enzymes to the wastewater stream.Mechanical improvements to the major wastewater pump station.Vapor-phase treatment at strategic points in the system, via both chemical scrubbing and biofiltration.Several types of liquid-phase treatment were employed, including iron salts, a nitrate inhibitor, and a biological enzyme. The chemical that worked best was a combination of the three. For reasons of cost and effectiveness, however, liquid-phase treatment was not sufficient to reduce the odor complaints to an acceptable level.Several mechanical improvements to the City's largest wastewater pump station were made, including submergence of the force main discharge point, and installation of a submerged mechanical mixer to break up the wet-well scum layer. A third recommendation (variablespeed pumping) was not implemented due to cost. Submergence of the force-main discharge point and installation of the mixer resulted in reduction of odor complaints from the neighborhoods surrounding the pump station. The mixer installation paid for itself in less than two years by eliminating the City's need to remove the wet-well scum layer by vacuumtruck every two to three months. Odor complaints increased in the downstream neighborhoods, however, likely because of the increased organic load of the wastewater conveyed from the pump station as a result of the mixer installation.Even with the partial success of liquid-phase treatment and mechanical improvements, odor complaints continued to a point that the City decided to invest in the third level of vaporphase treatment. Three areas were selected for odor control, summarized below:The City's largest wastewater pump station (discussed above): Odor complaints had diminished but were still not down to an acceptable level, and the cost of liquid-phase treatment warranted installation of a vapor-phase system. Biofiltration was selected.The force-main discharge point from the above-mentioned pump station: Large amounts of hydrogen sulfide were released at this location due to exposure of the anaerobic wastewater to air at the force main discharge point, so a dry scrubber was recommended with its media targeted for hydrogen sulfide removal.A neighborhood surrounding the 48-inch interceptor on its way to the WWTP: Mercaptans were the prevalent odorant in this area, believed to be due to biological decay of the wastewater prompted by long residence time in the system. A dry scrubber was recommended, with its media targeted for mercaptans and total reduced sulfides.The vapor-phase odor control devices described above have been effective and resulted in a significant decrease in odor complaints.
The City of Gastonia's municipal wastewater system serves a population exceeding 80,000, with a large industrial base that consumes over 40% of its total system capacity. The service area now covers more than 50 square miles, including most of Gaston County and extending beyond county borders into several surrounding counties as well as South Carolina. The City's wastewater collection system...
Author(s)
Robert H. ForbesDavid HuxLarry CummingsSteven M. Goodwin
SourceProceedings of the Water Environment Federation
SubjectSession 2 Emissions from Collection and Conveyance Systems
Document typeConference Paper
PublisherWater Environment Federation
Print publication date Jan, 2002
ISSN1938-6478
SICI1938-6478(20020101)2002:5L.98;1-
DOI10.2175/193864702785140447
Volume / Issue2002 / 5
Content sourceOdors and Air Pollutants Conference
First / last page(s)98 - 108
Copyright2002
Word count709

Actions, changes & tasks

Outstanding Actions

Add action for paragraph

Current Changes

Add signficant change

Current Tasks

Add risk task

Connect with us

Follow us on Facebook
Follow us on Twitter
Connect to us on LinkedIn
Subscribe on YouTube
Powered by Librios Ltd
Powered by Librios Ltd
Authors
Terms of Use
Policies
Help
Accessibility
Contact us
Copyright © 2024 by the Water Environment Federation
Loading items
There are no items to display at the moment.
Something went wrong trying to load these items.
Description: WWTF Digital Boot 180x150
WWTF Digital (180x150)
Created on Jul 02
Websitehttps:/­/­www.wef.org/­wwtf?utm_medium=WWTF&utm_source=AccessWater&utm_campaign=WWTF
180x150
Robert H. Forbes# David Hux# Larry Cummings# Steven M. Goodwin. THREE-STEP PROCESS TO SUCCESS IN CONTROLLING WASTEWATER COLLECTION SYSTEM ODORS IN GASTONIA, NORTH CAROLINA. Alexandria, VA 22314-1994, USA: Water Environment Federation, 2018. Web. 6 Jun. 2025. <https://www.accesswater.org?id=-289578CITANCHOR>.
Robert H. Forbes# David Hux# Larry Cummings# Steven M. Goodwin. THREE-STEP PROCESS TO SUCCESS IN CONTROLLING WASTEWATER COLLECTION SYSTEM ODORS IN GASTONIA, NORTH CAROLINA. Alexandria, VA 22314-1994, USA: Water Environment Federation, 2018. Accessed June 6, 2025. https://www.accesswater.org/?id=-289578CITANCHOR.
Robert H. Forbes# David Hux# Larry Cummings# Steven M. Goodwin
THREE-STEP PROCESS TO SUCCESS IN CONTROLLING WASTEWATER COLLECTION SYSTEM ODORS IN GASTONIA, NORTH CAROLINA
Access Water
Water Environment Federation
December 22, 2018
June 6, 2025
https://www.accesswater.org/?id=-289578CITANCHOR