lastID = -291543
Skip to main content Skip to top navigation Skip to site search
Top of page
  • My citations options
    Web Back (from Web)
    Chicago Back (from Chicago)
    MLA Back (from MLA)
Close action menu

You need to login to use this feature.

Please wait a moment…
Please wait while we update your results...
Please wait a moment...
Description: Access Water
Context Menu
Description: Book cover
OVERCOMING OPERATIONAL HURDLES ASSOCIATED WITH UV/OXIDATION ANCILLARY EQUIPMENT UTILIZED FOR SVOC REMOVAL FROM IMPACTED GROUNDWATER
  • Browse
  • Compilations
    • Compilations list
  • Subscriptions
Tools

Related contents

Loading related content

Workflow

No linked records yet

X
  • Current: 2022-05-06 15:00:39 Adam Phillips
  • 2022-05-06 15:00:38 Adam Phillips
  • 2020-03-26 23:21:36 Adam Phillips
  • 2020-02-01 02:40:40 Administrator
  • 2020-02-01 02:40:39 Administrator
  • 2020-02-01 02:40:38 Administrator
Description: Access Water
  • Browse
  • Compilations
  • Subscriptions
Log in
0
Accessibility Options

Base text size -

This is a sample piece of body text
Larger
Smaller
  • Shopping basket (0)
  • Accessibility options
  • Return to previous
Description: Book cover
OVERCOMING OPERATIONAL HURDLES ASSOCIATED WITH UV/OXIDATION ANCILLARY EQUIPMENT UTILIZED FOR SVOC REMOVAL FROM IMPACTED GROUNDWATER

OVERCOMING OPERATIONAL HURDLES ASSOCIATED WITH UV/OXIDATION ANCILLARY EQUIPMENT UTILIZED FOR SVOC REMOVAL FROM IMPACTED GROUNDWATER

OVERCOMING OPERATIONAL HURDLES ASSOCIATED WITH UV/OXIDATION ANCILLARY EQUIPMENT UTILIZED FOR SVOC REMOVAL FROM IMPACTED GROUNDWATER

  • New
  • View
  • Details
  • Reader
  • Default
  • Share
  • Email
  • Facebook
  • Twitter
  • LinkedIn
  • New
  • View
  • Default view
  • Reader view
  • Data view
  • Details

This page cannot be printed from here

Please use the dedicated print option from the 'view' drop down menu located in the blue ribbon in the top, right section of the publication.

screenshot of print menu option

Description: Book cover
OVERCOMING OPERATIONAL HURDLES ASSOCIATED WITH UV/OXIDATION ANCILLARY EQUIPMENT UTILIZED FOR SVOC REMOVAL FROM IMPACTED GROUNDWATER
Abstract
A multi-process groundwater treatment plant was recently started up at a southern New England groundwater treatment plant to reduce concentrations of aromatic and chlorinated aromatic solvents present in the site's groundwater. VOC and SVOC impacted groundwater is treated to meet strict State Surface Water Discharge Criteria (SWDC) concentrations using metals precipitation, sedimentation and filtration, followed by organics treatment process using UV and hydrogen peroxide. Following UV/peroxide treatment, groundwater is treated using a shallow tray air stripper for polishing, followed by two catalytic activated carbon units for excess hydrogen peroxide removal. The treated groundwater is discharged to a nearby surface water body following pH neutralization. In addition, there is a soil vapor extraction (SVE) offgas treatment system consisting of a catalytic oxidation unit and acid gas scrubber in operation to treat impacted soil gas from the subsurface residual source areas.The UV oxidation system operates with a residual hydrogen peroxide concentration of up to 50 mg/L, and this concentration must be reduced to less than 5 mg/L prior to discharge. Operational difficulties occurred with the full-scale catalytic carbon units. Excessive headloss through the units developed over short intervals and carbon fines were periodically observed in the treated effluent. In addition, the acid gas scrubber uses a slipstream of the treated process water effluent to quench the offgas from the catalytic oxidizer prior to discharge into the atmosphere. Carbon fines were entrained in this slipstream causing increased maintenance related issues with the acid gas scrubber.As a result of these problems, two alternative chemical methods for removal of the excess hydrogen peroxide were evaluated. The purpose of these tests was to identify, test and prove-out a possible replacement for the catalytic carbon in the event that the operational difficulties became excessive and/or performance was adversely affected to a point where the effluent could not reliably meet the SWDC. The alternative methods evaluated were catalase addition, which breaks down hydrogen peroxide into water and oxygen through biochemical enzymatic action, and sulfur dioxide, which reacts with hydrogen peroxide to form sulfuric acid. Field tests carried out at the site included both bench and full-scale evaluations of catalase and sulfur dioxide. Results obtained are presented and compared for process efficacy and operability, as well as operating costs. Sulfur dioxide was the recommended option due to its high process efficiency, instantaneous reaction time, and lower capital and operational costs, provided that personnel safety measures are enhanced due to concerns over sulfur dioxide's hazardous and toxic characteristics. Catalase is an easily implemented option and safer to use, but is more critically dependent on reaction time and mixing limitations in conventional stirred tanks and more expensive to use. Field tests demonstrated that additional catalase reaction time through inclusion of the effluent discharge line could compensate for these limitations.Ultimately, full-scale alternate hydrogen peroxide technologies were never deemed necessary because the operational difficulties were effectively managed by routine equipment cleaning and maintenance. Moreover, after approximately three years of continual operation of the groundwater pump and treat system, influent target SVOC concentrations decreased to a point where the operation of the UV/Oxidation and catalytic carbon units could be suspended. This paper presents bench-scale and full-scale testing objectives, methods and results and provides a conceptual design for a full-scale alternate hydrogen peroxide removal system for this particular site.
A multi-process groundwater treatment plant was recently started up at a southern New England groundwater treatment plant to reduce concentrations of aromatic and chlorinated aromatic solvents present in the site's groundwater. VOC and SVOC impacted groundwater is treated to meet strict State Surface Water Discharge Criteria (SWDC) concentrations using metals precipitation, sedimentation and...
Author(s)
Shannon L. DaigleDavid B. Froula
SourceProceedings of the Water Environment Federation
SubjectSession 12: Remediation System Operations
Document typeConference Paper
PublisherWater Environment Federation
Print publication date Jan, 2004
ISSN1938-6478
SICI1938-6478(20040101)2004:6L.645;1-
DOI10.2175/193864704784105779
Volume / Issue2004 / 6
Content sourceIndustrial Wastes (IW) Conference
First / last page(s)645 - 665
Copyright2004
Word count560

Purchase price $11.50

Get access
Log in Purchase content Purchase subscription
You may already have access to this content if you have previously purchased this content or have a subscription.
Need to create an account?

You can purchase access to this content but you might want to consider a subscription for a wide variety of items at a substantial discount!

Purchase access to 'OVERCOMING OPERATIONAL HURDLES ASSOCIATED WITH UV/OXIDATION ANCILLARY EQUIPMENT UTILIZED FOR SVOC REMOVAL FROM IMPACTED GROUNDWATER'

Add to cart
Purchase a subscription to gain access to 18,000+ Proceeding Papers, 25+ Fact Sheets, 20+ Technical Reports, 50+ magazine articles and select Technical Publications' chapters.
Loading items
There are no items to display at the moment.
Something went wrong trying to load these items.
Description: Book cover
OVERCOMING OPERATIONAL HURDLES ASSOCIATED WITH UV/OXIDATION ANCILLARY EQUIPMENT UTILIZED FOR SVOC REMOVAL FROM IMPACTED GROUNDWATER
Pricing
Non-member price: $11.50
Member price:
-291543
Get access
-291543
Log in Purchase content Purchase subscription
You may already have access to this content if you have previously purchased this content or have a subscription.
Need to create an account?

You can purchase access to this content but you might want to consider a subscription for a wide variety of items at a substantial discount!

Purchase access to 'OVERCOMING OPERATIONAL HURDLES ASSOCIATED WITH UV/OXIDATION ANCILLARY EQUIPMENT UTILIZED FOR SVOC REMOVAL FROM IMPACTED GROUNDWATER'

Add to cart
Purchase a subscription to gain access to 18,000+ Proceeding Papers, 25+ Fact Sheets, 20+ Technical Reports, 50+ magazine articles and select Technical Publications' chapters.

Details

Description: Book cover
OVERCOMING OPERATIONAL HURDLES ASSOCIATED WITH UV/OXIDATION ANCILLARY EQUIPMENT UTILIZED FOR SVOC REMOVAL FROM IMPACTED GROUNDWATER
Abstract
A multi-process groundwater treatment plant was recently started up at a southern New England groundwater treatment plant to reduce concentrations of aromatic and chlorinated aromatic solvents present in the site's groundwater. VOC and SVOC impacted groundwater is treated to meet strict State Surface Water Discharge Criteria (SWDC) concentrations using metals precipitation, sedimentation and filtration, followed by organics treatment process using UV and hydrogen peroxide. Following UV/peroxide treatment, groundwater is treated using a shallow tray air stripper for polishing, followed by two catalytic activated carbon units for excess hydrogen peroxide removal. The treated groundwater is discharged to a nearby surface water body following pH neutralization. In addition, there is a soil vapor extraction (SVE) offgas treatment system consisting of a catalytic oxidation unit and acid gas scrubber in operation to treat impacted soil gas from the subsurface residual source areas.The UV oxidation system operates with a residual hydrogen peroxide concentration of up to 50 mg/L, and this concentration must be reduced to less than 5 mg/L prior to discharge. Operational difficulties occurred with the full-scale catalytic carbon units. Excessive headloss through the units developed over short intervals and carbon fines were periodically observed in the treated effluent. In addition, the acid gas scrubber uses a slipstream of the treated process water effluent to quench the offgas from the catalytic oxidizer prior to discharge into the atmosphere. Carbon fines were entrained in this slipstream causing increased maintenance related issues with the acid gas scrubber.As a result of these problems, two alternative chemical methods for removal of the excess hydrogen peroxide were evaluated. The purpose of these tests was to identify, test and prove-out a possible replacement for the catalytic carbon in the event that the operational difficulties became excessive and/or performance was adversely affected to a point where the effluent could not reliably meet the SWDC. The alternative methods evaluated were catalase addition, which breaks down hydrogen peroxide into water and oxygen through biochemical enzymatic action, and sulfur dioxide, which reacts with hydrogen peroxide to form sulfuric acid. Field tests carried out at the site included both bench and full-scale evaluations of catalase and sulfur dioxide. Results obtained are presented and compared for process efficacy and operability, as well as operating costs. Sulfur dioxide was the recommended option due to its high process efficiency, instantaneous reaction time, and lower capital and operational costs, provided that personnel safety measures are enhanced due to concerns over sulfur dioxide's hazardous and toxic characteristics. Catalase is an easily implemented option and safer to use, but is more critically dependent on reaction time and mixing limitations in conventional stirred tanks and more expensive to use. Field tests demonstrated that additional catalase reaction time through inclusion of the effluent discharge line could compensate for these limitations.Ultimately, full-scale alternate hydrogen peroxide technologies were never deemed necessary because the operational difficulties were effectively managed by routine equipment cleaning and maintenance. Moreover, after approximately three years of continual operation of the groundwater pump and treat system, influent target SVOC concentrations decreased to a point where the operation of the UV/Oxidation and catalytic carbon units could be suspended. This paper presents bench-scale and full-scale testing objectives, methods and results and provides a conceptual design for a full-scale alternate hydrogen peroxide removal system for this particular site.
A multi-process groundwater treatment plant was recently started up at a southern New England groundwater treatment plant to reduce concentrations of aromatic and chlorinated aromatic solvents present in the site's groundwater. VOC and SVOC impacted groundwater is treated to meet strict State Surface Water Discharge Criteria (SWDC) concentrations using metals precipitation, sedimentation and...
Author(s)
Shannon L. DaigleDavid B. Froula
SourceProceedings of the Water Environment Federation
SubjectSession 12: Remediation System Operations
Document typeConference Paper
PublisherWater Environment Federation
Print publication date Jan, 2004
ISSN1938-6478
SICI1938-6478(20040101)2004:6L.645;1-
DOI10.2175/193864704784105779
Volume / Issue2004 / 6
Content sourceIndustrial Wastes (IW) Conference
First / last page(s)645 - 665
Copyright2004
Word count560

Actions, changes & tasks

Outstanding Actions

Add action for paragraph

Current Changes

Add signficant change

Current Tasks

Add risk task

Connect with us

Follow us on Facebook
Follow us on Twitter
Connect to us on LinkedIn
Subscribe on YouTube
Powered by Librios Ltd
Powered by Librios Ltd
Authors
Terms of Use
Policies
Help
Accessibility
Contact us
Copyright © 2024 by the Water Environment Federation
Loading items
There are no items to display at the moment.
Something went wrong trying to load these items.
Description: WWTF Digital Boot 180x150
WWTF Digital (180x150)
Created on Jul 02
Websitehttps:/­/­www.wef.org/­wwtf?utm_medium=WWTF&utm_source=AccessWater&utm_campaign=WWTF
180x150
Shannon L. Daigle# David B. Froula. OVERCOMING OPERATIONAL HURDLES ASSOCIATED WITH UV/OXIDATION ANCILLARY EQUIPMENT UTILIZED FOR SVOC REMOVAL FROM IMPACTED GROUNDWATER. Alexandria, VA 22314-1994, USA: Water Environment Federation, 2018. Web. 12 Jun. 2025. <https://www.accesswater.org?id=-291543CITANCHOR>.
Shannon L. Daigle# David B. Froula. OVERCOMING OPERATIONAL HURDLES ASSOCIATED WITH UV/OXIDATION ANCILLARY EQUIPMENT UTILIZED FOR SVOC REMOVAL FROM IMPACTED GROUNDWATER. Alexandria, VA 22314-1994, USA: Water Environment Federation, 2018. Accessed June 12, 2025. https://www.accesswater.org/?id=-291543CITANCHOR.
Shannon L. Daigle# David B. Froula
OVERCOMING OPERATIONAL HURDLES ASSOCIATED WITH UV/OXIDATION ANCILLARY EQUIPMENT UTILIZED FOR SVOC REMOVAL FROM IMPACTED GROUNDWATER
Access Water
Water Environment Federation
December 22, 2018
June 12, 2025
https://www.accesswater.org/?id=-291543CITANCHOR