lastID = -291817
Skip to main content Skip to top navigation Skip to site search
Top of page
  • My citations options
    Web Back (from Web)
    Chicago Back (from Chicago)
    MLA Back (from MLA)
Close action menu

You need to login to use this feature.

Please wait a moment…
Please wait while we update your results...
Please wait a moment...
Description: Access Water
Context Menu
Description: Book cover
USE OF BIOWIN AS A TOOL FOR WASTEWATER TREATMENT PLANT CAPACITY EVALUATION
  • Browse
  • Compilations
    • Compilations list
  • Subscriptions
Tools

Related contents

Loading related content

Workflow

No linked records yet

X
  • Current: 2020-02-01 06:08:37 Administrator
  • 2020-02-01 06:08:36 Administrator
Description: Access Water
  • Browse
  • Compilations
  • Subscriptions
Log in
0
Accessibility Options

Base text size -

This is a sample piece of body text
Larger
Smaller
  • Shopping basket (0)
  • Accessibility options
  • Return to previous
Description: Book cover
USE OF BIOWIN AS A TOOL FOR WASTEWATER TREATMENT PLANT CAPACITY EVALUATION

USE OF BIOWIN AS A TOOL FOR WASTEWATER TREATMENT PLANT CAPACITY EVALUATION

USE OF BIOWIN AS A TOOL FOR WASTEWATER TREATMENT PLANT CAPACITY EVALUATION

  • New
  • View
  • Details
  • Reader
  • Default
  • Share
  • Email
  • Facebook
  • Twitter
  • LinkedIn
  • New
  • View
  • Default view
  • Reader view
  • Data view
  • Details

This page cannot be printed from here

Please use the dedicated print option from the 'view' drop down menu located in the blue ribbon in the top, right section of the publication.

screenshot of print menu option

Description: Book cover
USE OF BIOWIN AS A TOOL FOR WASTEWATER TREATMENT PLANT CAPACITY EVALUATION
Abstract
Prompted by the potential benefits of multi-phase anaerobic digestion, such as improved digester performance, increased process reliability, sludge dewaterability, and the potential to produce Class A biosolids, the City of Phoenix Water Services Department (WSD) initiated a study in January 2003 to evaluate the feasibility of converting the existing single-stage high-rate anaerobic digestion process at the 23rd Avenue Wastewater Treatment Plant (WWTP) to a multiphase digestion process. Accompanying a higher volatile suspended solids reduction, multiphase digestion can result in elevated ammonia levels in the digested sludge. Dewatered sludge centrate with elevated ammonia would be returned to the plant's liquid stream via a side stream recycle and potentially impact nitrification performance. To assess the impact of multi-phase digestion on liquid stream treatment and provide a basis for plant expansion, process modeling using Biowin32 was performed at steady-state and with diurnally varying influent loads.Plant historical records were evaluated to obtain influent wastewater characteristics, unit process performance, and plant operational configuration. 2-weeks of intensive sampling were conducted to supplement plant data for characterizing influent, establishing influent diurnal patterns, and the process response to dynamic loading, all of which was used to validate the Biowin model calibration. Due to the configuration of the plant's sampling systems, intensive sampling data were obtained almost exclusively on the primary effluent. A mass balance was performed to back-calculate the raw influent characteristics based on the plant's historical primary treatment efficiency. Both the steady state and the extended period dynamic modeling for the intensive sampling period resulted in predictions that closely match key plant measurements obtained during the same period, such as aeration basin mixed liquor suspended solids (MLSS) and volatile suspended solids (MLVSS), effluent NO3− - N, TKN, and TSS.The calibrated model was then used to evaluate the maximum treatable flow and ammonia load, in order to determine the requirement for side stream treatment after the conversion to multiphase digestion. A set of limits was established to gauge acceptable plant operation and performance. At the winter average day maximum month (ADMM) condition, both steady state and dynamic modeling results indicate that the plant can produce satisfactory effluent while operating the existing process within the recommended limits at flow up to 63 MGD. At the rated flow, the hydraulic loadings of primary and secondary clarifiers, the BOD5 loading on aeration basins, and the total oxygen transfer rate (OTR) at the corresponding peak day condition would exceed the recommended limits. At summer ADMM loadings with one aeration basin out of service for maintenance, the plant could treat up to 61 MGD with the hydraulic loadings of primary and secondary clarifiers, the BOD5 loading on aeration basins, and the oxygen uptake rate (OUR) exceeding recommended limits. At both conditions, the total nitrogen loading to the aeration basins resulting from the modeling is regarded as the maximum allowable nitrogen loading. This is because any additional ammonia loading caused by multi-phase digestion would further increase the OTR or OUR requirement. Treatment for the ammonia in the side stream would be needed after the conversion to multi-phase digestion.
Prompted by the potential benefits of multi-phase anaerobic digestion, such as improved digester performance, increased process reliability, sludge dewaterability, and the potential to produce Class A biosolids, the City of Phoenix Water Services Department (WSD) initiated a study in January 2003 to evaluate the feasibility of converting the existing single-stage high-rate anaerobic digestion...
Author(s)
Li LeiRobert McCandlessQun HePeter OlszewskiJim CoughenourDamon S. Williams
SourceProceedings of the Water Environment Federation
SubjectSession 52: Municipal Wastewater Treatment Processes: Modeling to Optimize Wastewater Treatment Processes and Design
Document typeConference Paper
PublisherWater Environment Federation
Print publication date Jan, 2005
ISSN1938-6478
SICI1938-6478(20050101)2005:11L.4232;1-
DOI10.2175/193864705783866865
Volume / Issue2005 / 11
Content sourceWEFTEC
First / last page(s)4232 - 4254
Copyright2005
Word count517

Purchase price $11.50

Get access
Log in Purchase content Purchase subscription
You may already have access to this content if you have previously purchased this content or have a subscription.
Need to create an account?

You can purchase access to this content but you might want to consider a subscription for a wide variety of items at a substantial discount!

Purchase access to 'USE OF BIOWIN AS A TOOL FOR WASTEWATER TREATMENT PLANT CAPACITY EVALUATION'

Add to cart
Purchase a subscription to gain access to 18,000+ Proceeding Papers, 25+ Fact Sheets, 20+ Technical Reports, 50+ magazine articles and select Technical Publications' chapters.
Loading items
There are no items to display at the moment.
Something went wrong trying to load these items.
Description: Book cover
USE OF BIOWIN AS A TOOL FOR WASTEWATER TREATMENT PLANT CAPACITY EVALUATION
Pricing
Non-member price: $11.50
Member price:
-291817
Get access
-291817
Log in Purchase content Purchase subscription
You may already have access to this content if you have previously purchased this content or have a subscription.
Need to create an account?

You can purchase access to this content but you might want to consider a subscription for a wide variety of items at a substantial discount!

Purchase access to 'USE OF BIOWIN AS A TOOL FOR WASTEWATER TREATMENT PLANT CAPACITY EVALUATION'

Add to cart
Purchase a subscription to gain access to 18,000+ Proceeding Papers, 25+ Fact Sheets, 20+ Technical Reports, 50+ magazine articles and select Technical Publications' chapters.

Details

Description: Book cover
USE OF BIOWIN AS A TOOL FOR WASTEWATER TREATMENT PLANT CAPACITY EVALUATION
Abstract
Prompted by the potential benefits of multi-phase anaerobic digestion, such as improved digester performance, increased process reliability, sludge dewaterability, and the potential to produce Class A biosolids, the City of Phoenix Water Services Department (WSD) initiated a study in January 2003 to evaluate the feasibility of converting the existing single-stage high-rate anaerobic digestion process at the 23rd Avenue Wastewater Treatment Plant (WWTP) to a multiphase digestion process. Accompanying a higher volatile suspended solids reduction, multiphase digestion can result in elevated ammonia levels in the digested sludge. Dewatered sludge centrate with elevated ammonia would be returned to the plant's liquid stream via a side stream recycle and potentially impact nitrification performance. To assess the impact of multi-phase digestion on liquid stream treatment and provide a basis for plant expansion, process modeling using Biowin32 was performed at steady-state and with diurnally varying influent loads.Plant historical records were evaluated to obtain influent wastewater characteristics, unit process performance, and plant operational configuration. 2-weeks of intensive sampling were conducted to supplement plant data for characterizing influent, establishing influent diurnal patterns, and the process response to dynamic loading, all of which was used to validate the Biowin model calibration. Due to the configuration of the plant's sampling systems, intensive sampling data were obtained almost exclusively on the primary effluent. A mass balance was performed to back-calculate the raw influent characteristics based on the plant's historical primary treatment efficiency. Both the steady state and the extended period dynamic modeling for the intensive sampling period resulted in predictions that closely match key plant measurements obtained during the same period, such as aeration basin mixed liquor suspended solids (MLSS) and volatile suspended solids (MLVSS), effluent NO3− - N, TKN, and TSS.The calibrated model was then used to evaluate the maximum treatable flow and ammonia load, in order to determine the requirement for side stream treatment after the conversion to multiphase digestion. A set of limits was established to gauge acceptable plant operation and performance. At the winter average day maximum month (ADMM) condition, both steady state and dynamic modeling results indicate that the plant can produce satisfactory effluent while operating the existing process within the recommended limits at flow up to 63 MGD. At the rated flow, the hydraulic loadings of primary and secondary clarifiers, the BOD5 loading on aeration basins, and the total oxygen transfer rate (OTR) at the corresponding peak day condition would exceed the recommended limits. At summer ADMM loadings with one aeration basin out of service for maintenance, the plant could treat up to 61 MGD with the hydraulic loadings of primary and secondary clarifiers, the BOD5 loading on aeration basins, and the oxygen uptake rate (OUR) exceeding recommended limits. At both conditions, the total nitrogen loading to the aeration basins resulting from the modeling is regarded as the maximum allowable nitrogen loading. This is because any additional ammonia loading caused by multi-phase digestion would further increase the OTR or OUR requirement. Treatment for the ammonia in the side stream would be needed after the conversion to multi-phase digestion.
Prompted by the potential benefits of multi-phase anaerobic digestion, such as improved digester performance, increased process reliability, sludge dewaterability, and the potential to produce Class A biosolids, the City of Phoenix Water Services Department (WSD) initiated a study in January 2003 to evaluate the feasibility of converting the existing single-stage high-rate anaerobic digestion...
Author(s)
Li LeiRobert McCandlessQun HePeter OlszewskiJim CoughenourDamon S. Williams
SourceProceedings of the Water Environment Federation
SubjectSession 52: Municipal Wastewater Treatment Processes: Modeling to Optimize Wastewater Treatment Processes and Design
Document typeConference Paper
PublisherWater Environment Federation
Print publication date Jan, 2005
ISSN1938-6478
SICI1938-6478(20050101)2005:11L.4232;1-
DOI10.2175/193864705783866865
Volume / Issue2005 / 11
Content sourceWEFTEC
First / last page(s)4232 - 4254
Copyright2005
Word count517

Actions, changes & tasks

Outstanding Actions

Add action for paragraph

Current Changes

Add signficant change

Current Tasks

Add risk task

Connect with us

Follow us on Facebook
Follow us on Twitter
Connect to us on LinkedIn
Subscribe on YouTube
Powered by Librios Ltd
Powered by Librios Ltd
Authors
Terms of Use
Policies
Help
Accessibility
Contact us
Copyright © 2024 by the Water Environment Federation
Loading items
There are no items to display at the moment.
Something went wrong trying to load these items.
Description: WWTF Digital Boot 180x150
WWTF Digital (180x150)
Created on Jul 02
Websitehttps:/­/­www.wef.org/­wwtf?utm_medium=WWTF&utm_source=AccessWater&utm_campaign=WWTF
180x150
Li Lei# Robert McCandless# Qun He# Peter Olszewski# Jim Coughenour# Damon S. Williams. USE OF BIOWIN AS A TOOL FOR WASTEWATER TREATMENT PLANT CAPACITY EVALUATION. Alexandria, VA 22314-1994, USA: Water Environment Federation, 2018. Web. 5 Jun. 2025. <https://www.accesswater.org?id=-291817CITANCHOR>.
Li Lei# Robert McCandless# Qun He# Peter Olszewski# Jim Coughenour# Damon S. Williams. USE OF BIOWIN AS A TOOL FOR WASTEWATER TREATMENT PLANT CAPACITY EVALUATION. Alexandria, VA 22314-1994, USA: Water Environment Federation, 2018. Accessed June 5, 2025. https://www.accesswater.org/?id=-291817CITANCHOR.
Li Lei# Robert McCandless# Qun He# Peter Olszewski# Jim Coughenour# Damon S. Williams
USE OF BIOWIN AS A TOOL FOR WASTEWATER TREATMENT PLANT CAPACITY EVALUATION
Access Water
Water Environment Federation
December 22, 2018
June 5, 2025
https://www.accesswater.org/?id=-291817CITANCHOR