lastID = -292086
Skip to main content Skip to top navigation Skip to site search
Top of page
  • My citations options
    Web Back (from Web)
    Chicago Back (from Chicago)
    MLA Back (from MLA)
Close action menu

You need to login to use this feature.

Please wait a moment…
Please wait while we update your results...
Please wait a moment...
Description: Access Water
Context Menu
Description: Book cover
NITRITE REDUCTION EVALUATION FOR THE MIAMI-DADE WASD SOUTH DISTRICT WASTEWATER TREATMENT PLANT
  • Browse
  • Compilations
    • Compilations list
  • Subscriptions
Tools

Related contents

Loading related content

Workflow

No linked records yet

X
  • Current: 2022-05-04 19:46:52 Adam Phillips
  • 2022-05-04 19:46:51 Adam Phillips
  • 2020-02-01 02:00:10 Administrator
  • 2020-02-01 02:00:09 Administrator
Description: Access Water
  • Browse
  • Compilations
  • Subscriptions
Log in
0
Accessibility Options

Base text size -

This is a sample piece of body text
Larger
Smaller
  • Shopping basket (0)
  • Accessibility options
  • Return to previous
Description: Book cover
NITRITE REDUCTION EVALUATION FOR THE MIAMI-DADE WASD SOUTH DISTRICT WASTEWATER TREATMENT PLANT

NITRITE REDUCTION EVALUATION FOR THE MIAMI-DADE WASD SOUTH DISTRICT WASTEWATER TREATMENT PLANT

NITRITE REDUCTION EVALUATION FOR THE MIAMI-DADE WASD SOUTH DISTRICT WASTEWATER TREATMENT PLANT

  • New
  • View
  • Details
  • Reader
  • Default
  • Share
  • Email
  • Facebook
  • Twitter
  • LinkedIn
  • New
  • View
  • Default view
  • Reader view
  • Data view
  • Details

This page cannot be printed from here

Please use the dedicated print option from the 'view' drop down menu located in the blue ribbon in the top, right section of the publication.

screenshot of print menu option

Description: Book cover
NITRITE REDUCTION EVALUATION FOR THE MIAMI-DADE WASD SOUTH DISTRICT WASTEWATER TREATMENT PLANT
Abstract
The Miami-Dade Water and Sewer Department (Department) operates the 112.5 mgd average daily flow South District Wastewater Treatment Plant (SDWWTP) which utilizes the conventional pure oxygen activated sludge treatment process followed by deep well disposal to comply with cBOD5 of 20 mg/L and TSS of 20 mg/L permit limits. The SDWWTP consists of two plants operating in parallel see Figure 1. Plant 1 (75 mgd) consists of pretreatment facilities followed by four oxygenation reactors and four secondary clarifiers. Plant 2 (37.5 mgd) consists of pretreatment facilities, two oxygenation reactors and two secondary clarifiers.A Consent Order requires that the SDWWTP effluent meet both FDEP high level disinfection standards and EPA primary drinking water standards including a nitrite maximum contaminate limit (MCL) of 1.0 mg/L; which had occasional exceedences. To control the effluent nitrate concentrations, the historical data received, source control of nitrite and/or nitrifying bacteria, and operational modifications were investigated. Potential sources of nitrifying bacteria included treated leachate and hauled aerobically digested sludges. Source control options were reviewed. Operational controls evaluated included reducing the sludge age, chlorination to oxidize the nitrite and formation of an anoxic zone. The anoxic zone approach was selected and implemented with six months of successful operation.
The Miami-Dade Water and Sewer Department (Department) operates the 112.5 mgd average daily flow South District Wastewater Treatment Plant (SDWWTP) which utilizes the conventional pure oxygen activated sludge treatment process followed by deep well disposal to comply with cBOD5 of 20 mg/L and TSS of 20 mg/L permit limits. The SDWWTP consists of two plants operating in parallel see Figure 1. Plant...
Author(s)
R. FergenP. PittJ. CowgillP. VinciR. HarrisS. KronheimE. Coro
SourceProceedings of the Water Environment Federation
SubjectSession 5B: Municipal Wastewater Treatment Processes: Biological Nutrient Removal
Document typeConference Paper
PublisherWater Environment Federation
Print publication date Jan, 2005
ISSN1938-6478
SICI1938-6478(20050101)2005:16L.576;1-
DOI10.2175/193864705783867558
Volume / Issue2005 / 16
Content sourceWEFTEC
First / last page(s)576 - 593
Copyright2005
Word count212

Purchase price $11.50

Get access
Log in Purchase content Purchase subscription
You may already have access to this content if you have previously purchased this content or have a subscription.
Need to create an account?

You can purchase access to this content but you might want to consider a subscription for a wide variety of items at a substantial discount!

Purchase access to 'NITRITE REDUCTION EVALUATION FOR THE MIAMI-DADE WASD SOUTH DISTRICT WASTEWATER TREATMENT PLANT'

Add to cart
Purchase a subscription to gain access to 18,000+ Proceeding Papers, 25+ Fact Sheets, 20+ Technical Reports, 50+ magazine articles and select Technical Publications' chapters.
Loading items
There are no items to display at the moment.
Something went wrong trying to load these items.
Description: Book cover
NITRITE REDUCTION EVALUATION FOR THE MIAMI-DADE WASD SOUTH DISTRICT WASTEWATER TREATMENT PLANT
Pricing
Non-member price: $11.50
Member price:
-292086
Get access
-292086
Log in Purchase content Purchase subscription
You may already have access to this content if you have previously purchased this content or have a subscription.
Need to create an account?

You can purchase access to this content but you might want to consider a subscription for a wide variety of items at a substantial discount!

Purchase access to 'NITRITE REDUCTION EVALUATION FOR THE MIAMI-DADE WASD SOUTH DISTRICT WASTEWATER TREATMENT PLANT'

Add to cart
Purchase a subscription to gain access to 18,000+ Proceeding Papers, 25+ Fact Sheets, 20+ Technical Reports, 50+ magazine articles and select Technical Publications' chapters.

Details

Description: Book cover
NITRITE REDUCTION EVALUATION FOR THE MIAMI-DADE WASD SOUTH DISTRICT WASTEWATER TREATMENT PLANT
Abstract
The Miami-Dade Water and Sewer Department (Department) operates the 112.5 mgd average daily flow South District Wastewater Treatment Plant (SDWWTP) which utilizes the conventional pure oxygen activated sludge treatment process followed by deep well disposal to comply with cBOD5 of 20 mg/L and TSS of 20 mg/L permit limits. The SDWWTP consists of two plants operating in parallel see Figure 1. Plant 1 (75 mgd) consists of pretreatment facilities followed by four oxygenation reactors and four secondary clarifiers. Plant 2 (37.5 mgd) consists of pretreatment facilities, two oxygenation reactors and two secondary clarifiers.A Consent Order requires that the SDWWTP effluent meet both FDEP high level disinfection standards and EPA primary drinking water standards including a nitrite maximum contaminate limit (MCL) of 1.0 mg/L; which had occasional exceedences. To control the effluent nitrate concentrations, the historical data received, source control of nitrite and/or nitrifying bacteria, and operational modifications were investigated. Potential sources of nitrifying bacteria included treated leachate and hauled aerobically digested sludges. Source control options were reviewed. Operational controls evaluated included reducing the sludge age, chlorination to oxidize the nitrite and formation of an anoxic zone. The anoxic zone approach was selected and implemented with six months of successful operation.
The Miami-Dade Water and Sewer Department (Department) operates the 112.5 mgd average daily flow South District Wastewater Treatment Plant (SDWWTP) which utilizes the conventional pure oxygen activated sludge treatment process followed by deep well disposal to comply with cBOD5 of 20 mg/L and TSS of 20 mg/L permit limits. The SDWWTP consists of two plants operating in parallel see Figure 1. Plant...
Author(s)
R. FergenP. PittJ. CowgillP. VinciR. HarrisS. KronheimE. Coro
SourceProceedings of the Water Environment Federation
SubjectSession 5B: Municipal Wastewater Treatment Processes: Biological Nutrient Removal
Document typeConference Paper
PublisherWater Environment Federation
Print publication date Jan, 2005
ISSN1938-6478
SICI1938-6478(20050101)2005:16L.576;1-
DOI10.2175/193864705783867558
Volume / Issue2005 / 16
Content sourceWEFTEC
First / last page(s)576 - 593
Copyright2005
Word count212

Actions, changes & tasks

Outstanding Actions

Add action for paragraph

Current Changes

Add signficant change

Current Tasks

Add risk task

Connect with us

Follow us on Facebook
Follow us on Twitter
Connect to us on LinkedIn
Subscribe on YouTube
Powered by Librios Ltd
Powered by Librios Ltd
Authors
Terms of Use
Policies
Help
Accessibility
Contact us
Copyright © 2024 by the Water Environment Federation
Loading items
There are no items to display at the moment.
Something went wrong trying to load these items.
Description: WWTF Digital Boot 180x150
WWTF Digital (180x150)
Created on Jul 02
Websitehttps:/­/­www.wef.org/­wwtf?utm_medium=WWTF&utm_source=AccessWater&utm_campaign=WWTF
180x150
R. Fergen# P. Pitt# J. Cowgill# P. Vinci# R. Harris# S. Kronheim# E. Coro. NITRITE REDUCTION EVALUATION FOR THE MIAMI-DADE WASD SOUTH DISTRICT WASTEWATER TREATMENT PLANT. Alexandria, VA 22314-1994, USA: Water Environment Federation, 2018. Web. 12 Jun. 2025. <https://www.accesswater.org?id=-292086CITANCHOR>.
R. Fergen# P. Pitt# J. Cowgill# P. Vinci# R. Harris# S. Kronheim# E. Coro. NITRITE REDUCTION EVALUATION FOR THE MIAMI-DADE WASD SOUTH DISTRICT WASTEWATER TREATMENT PLANT. Alexandria, VA 22314-1994, USA: Water Environment Federation, 2018. Accessed June 12, 2025. https://www.accesswater.org/?id=-292086CITANCHOR.
R. Fergen# P. Pitt# J. Cowgill# P. Vinci# R. Harris# S. Kronheim# E. Coro
NITRITE REDUCTION EVALUATION FOR THE MIAMI-DADE WASD SOUTH DISTRICT WASTEWATER TREATMENT PLANT
Access Water
Water Environment Federation
December 22, 2018
June 12, 2025
https://www.accesswater.org/?id=-292086CITANCHOR