lastID = -292467
Skip to main content Skip to top navigation Skip to site search
Top of page
  • My citations options
    Web Back (from Web)
    Chicago Back (from Chicago)
    MLA Back (from MLA)
Close action menu

You need to login to use this feature.

Please wait a moment…
Please wait while we update your results...
Please wait a moment...
Description: Access Water
Context Menu
Description: Book cover
High Load Field Test of a Secondary Clarifier
  • Browse
  • Compilations
    • Compilations list
  • Subscriptions
Tools

Related contents

Loading related content

Workflow

No linked records yet

X
  • Current: 2020-03-27 01:32:55 Adam Phillips
  • 2020-03-27 01:32:52 Adam Phillips
  • 2020-01-31 23:51:00 Administrator
  • 2020-01-31 23:50:59 Administrator
  • 2020-01-31 23:50:58 Administrator
Description: Access Water
  • Browse
  • Compilations
  • Subscriptions
Log in
0
Accessibility Options

Base text size -

This is a sample piece of body text
Larger
Smaller
  • Shopping basket (0)
  • Accessibility options
  • Return to previous
Description: Book cover
High Load Field Test of a Secondary Clarifier

High Load Field Test of a Secondary Clarifier

High Load Field Test of a Secondary Clarifier

  • New
  • View
  • Details
  • Reader
  • Default
  • Share
  • Email
  • Facebook
  • Twitter
  • LinkedIn
  • New
  • View
  • Default view
  • Reader view
  • Data view
  • Details

This page cannot be printed from here

Please use the dedicated print option from the 'view' drop down menu located in the blue ribbon in the top, right section of the publication.

screenshot of print menu option

Description: Book cover
High Load Field Test of a Secondary Clarifier
Abstract
Secondary clarifiers were field tested for hydraulic characteristics and performance and checked with the Clarifier Research Technical Committee's draft protocol at a Wisconsin, Ohio and North Carolina WWTP. The test clarifiers were two (2) 42.68m (140 ft.) diameter; 35.1m (115 ft.) and 48.78m (160 ft.) x peripheral-feed, inlet, peripheral-overflow clarifiers. Settled solids are collected by a rotating hydraulic header for all four (4) units.The WWTPs wanted to determine the capacity of the existing secondary clarifier system for use in planning of plant upgrades and permitting. Also, to determine if any upgrades or changes should be considered for the units.Multiple tests were conducted at average and max flow conditions approximating 800 to 1,700 GPD/sq. ft. (1.36 and 2.9 m/h). Influent mixed liquor concentrations RAS concentrations, effluent TSS, sludge blanket profiles, and flow rates were recorded to document the performance of the clarifier. Sludge volume index (SSVI) and SVI and in-situ dispersed solids (IDS) tests were conducted to quantify the settling and flocculation characteristics of the influent mixed liquor. Hydraulic characteristics of the clarifier were assessed by conducting slug dye and flow pattern/solids distribution and drogue tests.To run the tests, it was necessary to take basins off-line. It was possible to maintain an overflow rate of up to 1,700 GPD/sq. ft. (2.9 m/h) with a solids loading of up to 50 lbs./sq. ft./day (243 kgs/sq. m/day).Results of the high load test show a hydraulic and solids loading efficiency well above conventional design parameters. Solids studies showed effluent suspended solids (ESS) levels could be maintained below 20 ppm at hydraulic loading up to 1,700 GPD/sq. ft/day (2.9 m/h) and 50 lbs/sf/d.The flow pattern was away from the effluent weirs.The sludge blanket is controlled.The three (3) studies reported in this paper verify the original work done by Crosby in the late 1970's “that the PF/PO clarifier acts as an upflow clarifier and needs little or no modifications to its design.”It was possible to maintain, over an eight (8) hour and a 7 day period, an overflow rate of up to 1,700 gpd/sq ft. with a solids loading of up to 50 lbs./sq. ft/day.
Secondary clarifiers were field tested for hydraulic characteristics and performance and checked with the Clarifier Research Technical Committee's draft protocol at a Wisconsin, Ohio and North Carolina WWTP. The test clarifiers were two (2) 42.68m (140 ft.) diameter; 35.1m (115 ft.) and 48.78m (160 ft.) x peripheral-feed, inlet, peripheral-overflow clarifiers. Settled solids are collected by a...
Author(s)
W.H. Boyle
SourceProceedings of the Water Environment Federation
SubjectSession 1: Wastewater Treatment Plant Technologies and Upgrading I
Document typeConference Paper
PublisherWater Environment Federation
Print publication date Jan, 2005
ISSN1938-6478
SICI1938-6478(20050101)2005:5L.8;1-
DOI10.2175/193864705783977709
Volume / Issue2005 / 5
Content sourceTechnology Conference
First / last page(s)8 - 38
Copyright2005
Word count357

Purchase price $11.50

Get access
Log in Purchase content Purchase subscription
You may already have access to this content if you have previously purchased this content or have a subscription.
Need to create an account?

You can purchase access to this content but you might want to consider a subscription for a wide variety of items at a substantial discount!

Purchase access to 'High Load Field Test of a Secondary Clarifier'

Add to cart
Purchase a subscription to gain access to 18,000+ Proceeding Papers, 25+ Fact Sheets, 20+ Technical Reports, 50+ magazine articles and select Technical Publications' chapters.
Loading items
There are no items to display at the moment.
Something went wrong trying to load these items.
Description: Book cover
High Load Field Test of a Secondary Clarifier
Pricing
Non-member price: $11.50
Member price:
-292467
Get access
-292467
Log in Purchase content Purchase subscription
You may already have access to this content if you have previously purchased this content or have a subscription.
Need to create an account?

You can purchase access to this content but you might want to consider a subscription for a wide variety of items at a substantial discount!

Purchase access to 'High Load Field Test of a Secondary Clarifier'

Add to cart
Purchase a subscription to gain access to 18,000+ Proceeding Papers, 25+ Fact Sheets, 20+ Technical Reports, 50+ magazine articles and select Technical Publications' chapters.

Details

Description: Book cover
High Load Field Test of a Secondary Clarifier
Abstract
Secondary clarifiers were field tested for hydraulic characteristics and performance and checked with the Clarifier Research Technical Committee's draft protocol at a Wisconsin, Ohio and North Carolina WWTP. The test clarifiers were two (2) 42.68m (140 ft.) diameter; 35.1m (115 ft.) and 48.78m (160 ft.) x peripheral-feed, inlet, peripheral-overflow clarifiers. Settled solids are collected by a rotating hydraulic header for all four (4) units.The WWTPs wanted to determine the capacity of the existing secondary clarifier system for use in planning of plant upgrades and permitting. Also, to determine if any upgrades or changes should be considered for the units.Multiple tests were conducted at average and max flow conditions approximating 800 to 1,700 GPD/sq. ft. (1.36 and 2.9 m/h). Influent mixed liquor concentrations RAS concentrations, effluent TSS, sludge blanket profiles, and flow rates were recorded to document the performance of the clarifier. Sludge volume index (SSVI) and SVI and in-situ dispersed solids (IDS) tests were conducted to quantify the settling and flocculation characteristics of the influent mixed liquor. Hydraulic characteristics of the clarifier were assessed by conducting slug dye and flow pattern/solids distribution and drogue tests.To run the tests, it was necessary to take basins off-line. It was possible to maintain an overflow rate of up to 1,700 GPD/sq. ft. (2.9 m/h) with a solids loading of up to 50 lbs./sq. ft./day (243 kgs/sq. m/day).Results of the high load test show a hydraulic and solids loading efficiency well above conventional design parameters. Solids studies showed effluent suspended solids (ESS) levels could be maintained below 20 ppm at hydraulic loading up to 1,700 GPD/sq. ft/day (2.9 m/h) and 50 lbs/sf/d.The flow pattern was away from the effluent weirs.The sludge blanket is controlled.The three (3) studies reported in this paper verify the original work done by Crosby in the late 1970's “that the PF/PO clarifier acts as an upflow clarifier and needs little or no modifications to its design.”It was possible to maintain, over an eight (8) hour and a 7 day period, an overflow rate of up to 1,700 gpd/sq ft. with a solids loading of up to 50 lbs./sq. ft/day.
Secondary clarifiers were field tested for hydraulic characteristics and performance and checked with the Clarifier Research Technical Committee's draft protocol at a Wisconsin, Ohio and North Carolina WWTP. The test clarifiers were two (2) 42.68m (140 ft.) diameter; 35.1m (115 ft.) and 48.78m (160 ft.) x peripheral-feed, inlet, peripheral-overflow clarifiers. Settled solids are collected by a...
Author(s)
W.H. Boyle
SourceProceedings of the Water Environment Federation
SubjectSession 1: Wastewater Treatment Plant Technologies and Upgrading I
Document typeConference Paper
PublisherWater Environment Federation
Print publication date Jan, 2005
ISSN1938-6478
SICI1938-6478(20050101)2005:5L.8;1-
DOI10.2175/193864705783977709
Volume / Issue2005 / 5
Content sourceTechnology Conference
First / last page(s)8 - 38
Copyright2005
Word count357

Actions, changes & tasks

Outstanding Actions

Add action for paragraph

Current Changes

Add signficant change

Current Tasks

Add risk task

Connect with us

Follow us on Facebook
Follow us on Twitter
Connect to us on LinkedIn
Subscribe on YouTube
Powered by Librios Ltd
Powered by Librios Ltd
Authors
Terms of Use
Policies
Help
Accessibility
Contact us
Copyright © 2024 by the Water Environment Federation
Loading items
There are no items to display at the moment.
Something went wrong trying to load these items.
Description: WWTF Digital Boot 180x150
WWTF Digital (180x150)
Created on Jul 02
Websitehttps:/­/­www.wef.org/­wwtf?utm_medium=WWTF&utm_source=AccessWater&utm_campaign=WWTF
180x150
W.H. Boyle. High Load Field Test of a Secondary Clarifier. Alexandria, VA 22314-1994, USA: Water Environment Federation, 2018. Web. 6 Jun. 2025. <https://www.accesswater.org?id=-292467CITANCHOR>.
W.H. Boyle. High Load Field Test of a Secondary Clarifier. Alexandria, VA 22314-1994, USA: Water Environment Federation, 2018. Accessed June 6, 2025. https://www.accesswater.org/?id=-292467CITANCHOR.
W.H. Boyle
High Load Field Test of a Secondary Clarifier
Access Water
Water Environment Federation
December 22, 2018
June 6, 2025
https://www.accesswater.org/?id=-292467CITANCHOR