lastID = -292628
Skip to main content Skip to top navigation Skip to site search
Top of page
  • My citations options
    Web Back (from Web)
    Chicago Back (from Chicago)
    MLA Back (from MLA)
Close action menu

You need to login to use this feature.

Please wait a moment…
Please wait while we update your results...
Please wait a moment...
Description: Access Water
Context Menu
Description: Book cover
MIAMI-DADE LATERAL PILOT PROGRAM
  • Browse
  • Compilations
    • Compilations list
  • Subscriptions
Tools

Related contents

Loading related content

Workflow

No linked records yet

X
  • Current: 2022-05-06 11:40:06 Adam Phillips
  • 2022-05-06 11:40:05 Adam Phillips
  • 2020-02-01 01:28:51 Administrator
  • 2020-02-01 01:28:50 Administrator
  • 2020-02-01 01:28:49 Administrator
Description: Access Water
  • Browse
  • Compilations
  • Subscriptions
Log in
0
Accessibility Options

Base text size -

This is a sample piece of body text
Larger
Smaller
  • Shopping basket (0)
  • Accessibility options
  • Return to previous
Description: Book cover
MIAMI-DADE LATERAL PILOT PROGRAM

MIAMI-DADE LATERAL PILOT PROGRAM

MIAMI-DADE LATERAL PILOT PROGRAM

  • New
  • View
  • Details
  • Reader
  • Default
  • Share
  • Email
  • Facebook
  • Twitter
  • LinkedIn
  • New
  • View
  • Default view
  • Reader view
  • Data view
  • Details

This page cannot be printed from here

Please use the dedicated print option from the 'view' drop down menu located in the blue ribbon in the top, right section of the publication.

screenshot of print menu option

Description: Book cover
MIAMI-DADE LATERAL PILOT PROGRAM
Abstract
Since 1994 the Miami-Dade Water and Sewer Department (WASD) has been engaged in an extensive sanitary sewer system evaluation and rehabilitation program in an effort to reduce system infiltration, exfiltration and inflow (I/E/I). Under the I/E/I Program, the entire sanitary sewer collection system, which represents approximately 3,930 km (12.9 million feet) of gravity sewer lines and 58,000 manholes was evaluated by July 1997. The Program sewer evaluation consisted of cleaning and televising 100 percent of the gravity lines, the visual inspection of each manhole and the smoke testing of the entire system to identify defects. A total of 32,194 defects were identified and repaired.The I/E/I Program has been highly successful with system flows to the regional treatment facilities reduced by approximately 100 mgd. Although the system-wide infiltration was greatly reduced, Rainfall Dependent Infiltration / Inflow (RDII) and the various pump station and force main improvements have continued to increase the peak flows to the treatment facilities during heavy rainfall events. Since the mainline sewer components were fully investigated and laterals from the main sewer to the house (house lateral) have only been evaluated in close proximity to the mainline sewer, the sewer house laterals have been identified as the only system component not fully investigated.The house laterals above the normal water table were, therefore, considered the source of the RDII. In 1999, WASD developed an Initial Lateral Pilot Program to determine if house laterals could be the cause of the RDII and to quantify the effectiveness and cost of a lateral evaluation and repair program.Three collection basins were selected for the initial pilot program. Although all main sewers were repaired under the I/E/I Program, all basin main sewers were re-televised and smoke tested and all manholes were again visually inspected for defects. The identified repairs were completed and the manholes were sealed to reduce system inflow. After a significant rain event, rainfall dependent infiltration / inflow hydrograph signatures were obtained for the “before” baseline flow. Each basin lateral, both public and private sides, were then pressure tested for leaks and the defects were identified and repaired. Figures 1, 2 and 3 illustrate the effectiveness of the program where the RDII signature is reduced after repairs are made.
Since 1994 the Miami-Dade Water and Sewer Department (WASD) has been engaged in an extensive sanitary sewer system evaluation and rehabilitation program in an effort to reduce system infiltration, exfiltration and inflow (I/E/I). Under the I/E/I Program, the entire sanitary sewer collection system, which represents approximately 3,930 km (12.9 million feet) of gravity sewer lines and 58,000...
Author(s)
J. Peter LarsenJames T. CowgillRodney J. LovettFranklin Torrealba
SourceProceedings of the Water Environment Federation
SubjectSession 82: Collection Systems: Something for Everyone
Document typeConference Paper
PublisherWater Environment Federation
Print publication date Jan, 2005
ISSN1938-6478
SICI1938-6478(20050101)2005:8L.6860;1-
DOI10.2175/193864705783858747
Volume / Issue2005 / 8
Content sourceWEFTEC
First / last page(s)6860 - 6868
Copyright2005
Word count371

Purchase price $11.50

Get access
Log in Purchase content Purchase subscription
You may already have access to this content if you have previously purchased this content or have a subscription.
Need to create an account?

You can purchase access to this content but you might want to consider a subscription for a wide variety of items at a substantial discount!

Purchase access to 'MIAMI-DADE LATERAL PILOT PROGRAM'

Add to cart
Purchase a subscription to gain access to 18,000+ Proceeding Papers, 25+ Fact Sheets, 20+ Technical Reports, 50+ magazine articles and select Technical Publications' chapters.
Loading items
There are no items to display at the moment.
Something went wrong trying to load these items.
Description: Book cover
MIAMI-DADE LATERAL PILOT PROGRAM
Pricing
Non-member price: $11.50
Member price:
-292628
Get access
-292628
Log in Purchase content Purchase subscription
You may already have access to this content if you have previously purchased this content or have a subscription.
Need to create an account?

You can purchase access to this content but you might want to consider a subscription for a wide variety of items at a substantial discount!

Purchase access to 'MIAMI-DADE LATERAL PILOT PROGRAM'

Add to cart
Purchase a subscription to gain access to 18,000+ Proceeding Papers, 25+ Fact Sheets, 20+ Technical Reports, 50+ magazine articles and select Technical Publications' chapters.

Details

Description: Book cover
MIAMI-DADE LATERAL PILOT PROGRAM
Abstract
Since 1994 the Miami-Dade Water and Sewer Department (WASD) has been engaged in an extensive sanitary sewer system evaluation and rehabilitation program in an effort to reduce system infiltration, exfiltration and inflow (I/E/I). Under the I/E/I Program, the entire sanitary sewer collection system, which represents approximately 3,930 km (12.9 million feet) of gravity sewer lines and 58,000 manholes was evaluated by July 1997. The Program sewer evaluation consisted of cleaning and televising 100 percent of the gravity lines, the visual inspection of each manhole and the smoke testing of the entire system to identify defects. A total of 32,194 defects were identified and repaired.The I/E/I Program has been highly successful with system flows to the regional treatment facilities reduced by approximately 100 mgd. Although the system-wide infiltration was greatly reduced, Rainfall Dependent Infiltration / Inflow (RDII) and the various pump station and force main improvements have continued to increase the peak flows to the treatment facilities during heavy rainfall events. Since the mainline sewer components were fully investigated and laterals from the main sewer to the house (house lateral) have only been evaluated in close proximity to the mainline sewer, the sewer house laterals have been identified as the only system component not fully investigated.The house laterals above the normal water table were, therefore, considered the source of the RDII. In 1999, WASD developed an Initial Lateral Pilot Program to determine if house laterals could be the cause of the RDII and to quantify the effectiveness and cost of a lateral evaluation and repair program.Three collection basins were selected for the initial pilot program. Although all main sewers were repaired under the I/E/I Program, all basin main sewers were re-televised and smoke tested and all manholes were again visually inspected for defects. The identified repairs were completed and the manholes were sealed to reduce system inflow. After a significant rain event, rainfall dependent infiltration / inflow hydrograph signatures were obtained for the “before” baseline flow. Each basin lateral, both public and private sides, were then pressure tested for leaks and the defects were identified and repaired. Figures 1, 2 and 3 illustrate the effectiveness of the program where the RDII signature is reduced after repairs are made.
Since 1994 the Miami-Dade Water and Sewer Department (WASD) has been engaged in an extensive sanitary sewer system evaluation and rehabilitation program in an effort to reduce system infiltration, exfiltration and inflow (I/E/I). Under the I/E/I Program, the entire sanitary sewer collection system, which represents approximately 3,930 km (12.9 million feet) of gravity sewer lines and 58,000...
Author(s)
J. Peter LarsenJames T. CowgillRodney J. LovettFranklin Torrealba
SourceProceedings of the Water Environment Federation
SubjectSession 82: Collection Systems: Something for Everyone
Document typeConference Paper
PublisherWater Environment Federation
Print publication date Jan, 2005
ISSN1938-6478
SICI1938-6478(20050101)2005:8L.6860;1-
DOI10.2175/193864705783858747
Volume / Issue2005 / 8
Content sourceWEFTEC
First / last page(s)6860 - 6868
Copyright2005
Word count371

Actions, changes & tasks

Outstanding Actions

Add action for paragraph

Current Changes

Add signficant change

Current Tasks

Add risk task

Connect with us

Follow us on Facebook
Follow us on Twitter
Connect to us on LinkedIn
Subscribe on YouTube
Powered by Librios Ltd
Powered by Librios Ltd
Authors
Terms of Use
Policies
Help
Accessibility
Contact us
Copyright © 2024 by the Water Environment Federation
Loading items
There are no items to display at the moment.
Something went wrong trying to load these items.
Description: WWTF Digital Boot 180x150
WWTF Digital (180x150)
Created on Jul 02
Websitehttps:/­/­www.wef.org/­wwtf?utm_medium=WWTF&utm_source=AccessWater&utm_campaign=WWTF
180x150
J. Peter Larsen# James T. Cowgill# Rodney J. Lovett# Franklin Torrealba. MIAMI-DADE LATERAL PILOT PROGRAM. Alexandria, VA 22314-1994, USA: Water Environment Federation, 2018. Web. 6 Sep. 2025. <https://www.accesswater.org?id=-292628CITANCHOR>.
J. Peter Larsen# James T. Cowgill# Rodney J. Lovett# Franklin Torrealba. MIAMI-DADE LATERAL PILOT PROGRAM. Alexandria, VA 22314-1994, USA: Water Environment Federation, 2018. Accessed September 6, 2025. https://www.accesswater.org/?id=-292628CITANCHOR.
J. Peter Larsen# James T. Cowgill# Rodney J. Lovett# Franklin Torrealba
MIAMI-DADE LATERAL PILOT PROGRAM
Access Water
Water Environment Federation
December 22, 2018
September 6, 2025
https://www.accesswater.org/?id=-292628CITANCHOR