Hydrodynamic Cavitation Pilot Study for Controlling Cooling Water Quality
  • Browse
  • Compilations
    • Compilations list
  • Subscriptions
Tools

Related contents

Loading related content

Workflow

No linked records yet

X
  • Current: 2022-05-06 12:50:10 Adam Phillips
  • 2022-05-06 12:50:09 Adam Phillips
  • 2020-02-01 00:00:24 Administrator
  • 2020-02-01 00:00:23 Administrator
Description: Access Water
  • Browse
  • Compilations
  • Subscriptions
Log in
0
Accessibility Options

Base text size -

This is a sample piece of body text
Larger
Smaller
  • Shopping basket (0)
  • Accessibility options
  • Return to previous
Description: Book cover
Hydrodynamic Cavitation Pilot Study for Controlling Cooling Water Quality

Hydrodynamic Cavitation Pilot Study for Controlling Cooling Water Quality

Hydrodynamic Cavitation Pilot Study for Controlling Cooling Water Quality

  • New
  • View
  • Details
  • Reader
  • Default
  • Share
  • Email
  • Facebook
  • Twitter
  • LinkedIn
  • New
  • View
  • Default view
  • Reader view
  • Data view
  • Details

This page cannot be printed from here

Please use the dedicated print option from the 'view' drop down menu located in the blue ribbon in the top, right section of the publication.

screenshot of print menu option

Description: Book cover
Hydrodynamic Cavitation Pilot Study for Controlling Cooling Water Quality
Abstract
A field study was conducted on a cooling-tower system at an automotive manufacturing facility to evaluate the performance of a VRTX hydrodynamic cavitation device for disinfection, scaling, corrosion, and heat-transfer efficiency.Primary findings are: The VRTX unit performed as well as the chemical program that it replaced in terms of bacterial control without adding any chemicals (including disinfectants). The bacterial count was maintained at ∼104 cfu/mL over 2 months of the study.The VRTX unit enabled the cooling system to be operated at a higher cycle of concentration (CoC) than that used during the chemical program, without adversely affecting pH, scaling, and corrosion. This increase in CoC is expected to lead to a decreased water usage.The observed corrosion rates of copper and mild steel were either equivalent or better than those obtained during the chemical program, though corrosion of galvanized steel was appreciable.The use of the VRTX unit did not appear to adversely affect heat-transfer efficiency.
A field study was conducted on a cooling-tower system at an automotive manufacturing facility to evaluate the performance of a VRTX hydrodynamic cavitation device for disinfection, scaling, corrosion, and heat-transfer efficiency.Primary findings are: The VRTX unit performed as well as the chemical program that it replaced in terms of bacterial control without adding any chemicals (including...
Author(s)
W. A. GainesB. R. KimA. R. DrewsC. BaileyT. LochS. Frenette
SourceProceedings of the Water Environment Federation
SubjectSession 3: Industrial Issues and Treatment Technology: Water Conservation and Reuse
Document typeConference Paper
PublisherWater Environment Federation
Print publication date Jan, 2006
ISSN1938-6478
SICI1938-6478(20060101)2006:13L.154;1-
DOI10.2175/193864706783711027
Volume / Issue2006 / 13
Content sourceWEFTEC
First / last page(s)154 - 161
Copyright2006
Word count163

Purchase price $11.50

Get access
Log in Purchase content Purchase subscription
You may already have access to this content if you have previously purchased this content or have a subscription.
Need to create an account?

You can purchase access to this content but you might want to consider a subscription for a wide variety of items at a substantial discount!

Purchase access to 'Hydrodynamic Cavitation Pilot Study for Controlling Cooling Water Quality'

Add to cart
Purchase a subscription to gain access to 18,000+ Proceeding Papers, 25+ Fact Sheets, 20+ Technical Reports, 50+ magazine articles and select Technical Publications' chapters.
Loading items
There are no items to display at the moment.
Something went wrong trying to load these items.
Description: Book cover
Hydrodynamic Cavitation Pilot Study for Controlling Cooling Water Quality
Pricing
Non-member price: $11.50
Member price:
-292930
Get access
-292930
Log in Purchase content Purchase subscription
You may already have access to this content if you have previously purchased this content or have a subscription.
Need to create an account?

You can purchase access to this content but you might want to consider a subscription for a wide variety of items at a substantial discount!

Purchase access to 'Hydrodynamic Cavitation Pilot Study for Controlling Cooling Water Quality'

Add to cart
Purchase a subscription to gain access to 18,000+ Proceeding Papers, 25+ Fact Sheets, 20+ Technical Reports, 50+ magazine articles and select Technical Publications' chapters.

Details

Description: Book cover
Hydrodynamic Cavitation Pilot Study for Controlling Cooling Water Quality
Abstract
A field study was conducted on a cooling-tower system at an automotive manufacturing facility to evaluate the performance of a VRTX hydrodynamic cavitation device for disinfection, scaling, corrosion, and heat-transfer efficiency.Primary findings are: The VRTX unit performed as well as the chemical program that it replaced in terms of bacterial control without adding any chemicals (including disinfectants). The bacterial count was maintained at ∼104 cfu/mL over 2 months of the study.The VRTX unit enabled the cooling system to be operated at a higher cycle of concentration (CoC) than that used during the chemical program, without adversely affecting pH, scaling, and corrosion. This increase in CoC is expected to lead to a decreased water usage.The observed corrosion rates of copper and mild steel were either equivalent or better than those obtained during the chemical program, though corrosion of galvanized steel was appreciable.The use of the VRTX unit did not appear to adversely affect heat-transfer efficiency.
A field study was conducted on a cooling-tower system at an automotive manufacturing facility to evaluate the performance of a VRTX hydrodynamic cavitation device for disinfection, scaling, corrosion, and heat-transfer efficiency.Primary findings are: The VRTX unit performed as well as the chemical program that it replaced in terms of bacterial control without adding any chemicals (including...
Author(s)
W. A. GainesB. R. KimA. R. DrewsC. BaileyT. LochS. Frenette
SourceProceedings of the Water Environment Federation
SubjectSession 3: Industrial Issues and Treatment Technology: Water Conservation and Reuse
Document typeConference Paper
PublisherWater Environment Federation
Print publication date Jan, 2006
ISSN1938-6478
SICI1938-6478(20060101)2006:13L.154;1-
DOI10.2175/193864706783711027
Volume / Issue2006 / 13
Content sourceWEFTEC
First / last page(s)154 - 161
Copyright2006
Word count163

Actions, changes & tasks

Outstanding Actions

Add action for paragraph

Current Changes

Add signficant change

Current Tasks

Add risk task

Connect with us

Follow us on Facebook
Follow us on Twitter
Connect to us on LinkedIn
Subscribe on YouTube
Powered by Librios Ltd
Powered by Librios Ltd
Authors
Terms of Use
Policies
Help
Accessibility
Contact us
Copyright © 2025 by the Water Environment Federation
Loading items
There are no items to display at the moment.
Something went wrong trying to load these items.
Description: WWTF Digital Boot 180x150
WWTF Digital (180x150)
Created on Jul 02
Websitehttps:/­/­www.wef.org/­wwtf?utm_medium=WWTF&utm_source=AccessWater&utm_campaign=WWTF
180x150
W. A. Gaines# B. R. Kim# A. R. Drews# C. Bailey# T. Loch# S. Frenette. Hydrodynamic Cavitation Pilot Study for Controlling Cooling Water Quality. Alexandria, VA 22314-1994, USA: Water Environment Federation, 2018. Web. 3 Nov. 2025. <https://www.accesswater.org?id=-292930CITANCHOR>.
W. A. Gaines# B. R. Kim# A. R. Drews# C. Bailey# T. Loch# S. Frenette. Hydrodynamic Cavitation Pilot Study for Controlling Cooling Water Quality. Alexandria, VA 22314-1994, USA: Water Environment Federation, 2018. Accessed November 3, 2025. https://www.accesswater.org/?id=-292930CITANCHOR.
W. A. Gaines# B. R. Kim# A. R. Drews# C. Bailey# T. Loch# S. Frenette
Hydrodynamic Cavitation Pilot Study for Controlling Cooling Water Quality
Access Water
Water Environment Federation
December 22, 2018
November 3, 2025
https://www.accesswater.org/?id=-292930CITANCHOR