lastID = -293496
Skip to main content Skip to top navigation Skip to site search
Top of page
  • My citations options
    Web Back (from Web)
    Chicago Back (from Chicago)
    MLA Back (from MLA)
Close action menu

You need to login to use this feature.

Please wait a moment…
Please wait while we update your results...
Please wait a moment...
Loading icon
Description: Access Water
Context Menu
Description: Book cover
Evaluation of UV System Performance and Challenges of UV Validation Testing at the Laguna County Sanitation District
  • Browse
  • Compilations
    • Compilations list
  • Subscriptions
Tools

Related contents

Loading related content

Workflow

No linked records yet

X
  • Current: 2022-05-04 18:40:38 Adam Phillips
  • 2022-05-04 18:40:37 Adam Phillips
  • 2020-01-31 22:55:41 Administrator
  • 2020-01-31 22:55:40 Administrator
Description: Access Water
  • Browse
  • Compilations
  • Subscriptions
Log in
0
Accessibility Options

Base text size -

This is a sample piece of body text
Larger
Smaller
  • Shopping basket (0)
  • Accessibility options
  • Return to previous
Description: Book cover
Evaluation of UV System Performance and Challenges of UV Validation Testing at the Laguna County Sanitation District

Evaluation of UV System Performance and Challenges of UV Validation Testing at the Laguna County Sanitation District

Evaluation of UV System Performance and Challenges of UV Validation Testing at the Laguna County Sanitation District

  • New
  • View
  • Details
  • Reader
  • Default
  • Share
  • Email
  • Facebook
  • Twitter
  • LinkedIn
  • New
  • View
  • Default view
  • Reader view
  • Data view
  • Details

This page cannot be printed from here

Please use the dedicated print option from the 'view' drop down menu located in the blue ribbon in the top, right section of the publication.

screenshot of print menu option

Description: Book cover
Evaluation of UV System Performance and Challenges of UV Validation Testing at the Laguna County Sanitation District
Abstract
The Laguna County Sanitation District (LCSD) Water Reclamation Plant, with a design capacity of 3.7 mgd, produces tertiary water that was designed to meet California Title 22 unrestricted re-use criteria. The disinfection in LCSD is provided by an in-line Aquionics Model 7500 medium pressure UV system containing four UV banks. California Department of Health and Services (CDHS) require that all UV systems be validated according to the National Water Research Institute and American Water Works Association Research Foundation UV Disinfection Guidelines (NWRI/AWWARF 2003), before distributing reclaimed water to the end users. A set of laboratory and field testing has been performed to demonstrate the efficacy of the UV equipment. The early test results were, however, not in total compliance with DHS requirements. In two of the five collimated beam tests, the majority of the data (more than 20 percent) did not fall within the “check curves” established by the NWRI/AWWARF guidelines. CDHS directed LCSD to perform two additional collimated beam and full-scale tests to fully satisfy NWRI/AWWARF requirements. With the few changes and adjustments in testing procedure, the UV disinfection system satisfied the requirements for DHS approval. This paper discusses key challenges and presents lesson learned during this validation testing.
The Laguna County Sanitation District (LCSD) Water Reclamation Plant, with a design capacity of 3.7 mgd, produces tertiary water that was designed to meet California Title 22 unrestricted re-use criteria. The disinfection in LCSD is provided by an in-line Aquionics Model 7500 medium pressure UV system containing four UV banks. California Department of Health and Services (CDHS) require that all UV...
Author(s)
Ufuk G. ErdalJamal AwadMarry VorasisMarty WilderMark Moya
SourceProceedings of the Water Environment Federation
SubjectSession 55: Water Reclamation and Reuse: Water Reuse – Membrane Residuals and Reuse Disinfection
Document typeConference Paper
PublisherWater Environment Federation
Print publication date Jan, 2006
ISSN1938-6478
SICI1938-6478(20060101)2006:8L.4413;1-
DOI10.2175/193864706783778961
Volume / Issue2006 / 8
Content sourceWEFTEC
First / last page(s)4413 - 4425
Copyright2006
Word count217

Purchase price $11.50

Get access
Log in Purchase content Purchase subscription
You may already have access to this content if you have previously purchased this content or have a subscription.
Need to create an account?

You can purchase access to this content but you might want to consider a subscription for a wide variety of items at a substantial discount!

Purchase access to 'Evaluation of UV System Performance and Challenges of UV Validation Testing at the Laguna County Sanitation District'

Add to cart
Purchase a subscription to gain access to 18,000+ Proceeding Papers, 25+ Fact Sheets, 20+ Technical Reports, 50+ magazine articles and select Technical Publications' chapters.
Loading items
There are no items to display at the moment.
Something went wrong trying to load these items.
Description: Book cover
Evaluation of UV System Performance and Challenges of UV Validation Testing at the Laguna County Sanitation District
Pricing
Non-member price: $11.50
Member price:
-293496
Get access
-293496
Log in Purchase content Purchase subscription
You may already have access to this content if you have previously purchased this content or have a subscription.
Need to create an account?

You can purchase access to this content but you might want to consider a subscription for a wide variety of items at a substantial discount!

Purchase access to 'Evaluation of UV System Performance and Challenges of UV Validation Testing at the Laguna County Sanitation District'

Add to cart
Purchase a subscription to gain access to 18,000+ Proceeding Papers, 25+ Fact Sheets, 20+ Technical Reports, 50+ magazine articles and select Technical Publications' chapters.

Details

Description: Book cover
Evaluation of UV System Performance and Challenges of UV Validation Testing at the Laguna County Sanitation District
Abstract
The Laguna County Sanitation District (LCSD) Water Reclamation Plant, with a design capacity of 3.7 mgd, produces tertiary water that was designed to meet California Title 22 unrestricted re-use criteria. The disinfection in LCSD is provided by an in-line Aquionics Model 7500 medium pressure UV system containing four UV banks. California Department of Health and Services (CDHS) require that all UV systems be validated according to the National Water Research Institute and American Water Works Association Research Foundation UV Disinfection Guidelines (NWRI/AWWARF 2003), before distributing reclaimed water to the end users. A set of laboratory and field testing has been performed to demonstrate the efficacy of the UV equipment. The early test results were, however, not in total compliance with DHS requirements. In two of the five collimated beam tests, the majority of the data (more than 20 percent) did not fall within the “check curves” established by the NWRI/AWWARF guidelines. CDHS directed LCSD to perform two additional collimated beam and full-scale tests to fully satisfy NWRI/AWWARF requirements. With the few changes and adjustments in testing procedure, the UV disinfection system satisfied the requirements for DHS approval. This paper discusses key challenges and presents lesson learned during this validation testing.
The Laguna County Sanitation District (LCSD) Water Reclamation Plant, with a design capacity of 3.7 mgd, produces tertiary water that was designed to meet California Title 22 unrestricted re-use criteria. The disinfection in LCSD is provided by an in-line Aquionics Model 7500 medium pressure UV system containing four UV banks. California Department of Health and Services (CDHS) require that all UV...
Author(s)
Ufuk G. ErdalJamal AwadMarry VorasisMarty WilderMark Moya
SourceProceedings of the Water Environment Federation
SubjectSession 55: Water Reclamation and Reuse: Water Reuse – Membrane Residuals and Reuse Disinfection
Document typeConference Paper
PublisherWater Environment Federation
Print publication date Jan, 2006
ISSN1938-6478
SICI1938-6478(20060101)2006:8L.4413;1-
DOI10.2175/193864706783778961
Volume / Issue2006 / 8
Content sourceWEFTEC
First / last page(s)4413 - 4425
Copyright2006
Word count217

Actions, changes & tasks

Outstanding Actions

Add action for paragraph

Current Changes

Add signficant change

Current Tasks

Add risk task

Connect with us

Follow us on Facebook
Follow us on Twitter
Connect to us on LinkedIn
Subscribe on YouTube
Powered by Librios Ltd
Powered by Librios Ltd
Authors
Terms of Use
Policies
Help
Accessibility
Contact us
Copyright © 2025 by the Water Environment Federation
Loading items
There are no items to display at the moment.
Something went wrong trying to load these items.
Description: WWTF Digital Boot 180x150
WWTF Digital (180x150)
Created on Jul 02
Websitehttps:/­/­www.wef.org/­wwtf?utm_medium=WWTF&utm_source=AccessWater&utm_campaign=WWTF
180x150
Ufuk G. Erdal# Jamal Awad# Marry Vorasis# Marty Wilder# Mark Moya. Evaluation of UV System Performance and Challenges of UV Validation Testing at the Laguna County Sanitation District. Alexandria, VA 22314-1994, USA: Water Environment Federation, 2018. Web. 13 Dec. 2025. <https://www.accesswater.org?id=-293496CITANCHOR>.
Ufuk G. Erdal# Jamal Awad# Marry Vorasis# Marty Wilder# Mark Moya. Evaluation of UV System Performance and Challenges of UV Validation Testing at the Laguna County Sanitation District. Alexandria, VA 22314-1994, USA: Water Environment Federation, 2018. Accessed December 13, 2025. https://www.accesswater.org/?id=-293496CITANCHOR.
Ufuk G. Erdal# Jamal Awad# Marry Vorasis# Marty Wilder# Mark Moya
Evaluation of UV System Performance and Challenges of UV Validation Testing at the Laguna County Sanitation District
Access Water
Water Environment Federation
December 22, 2018
December 13, 2025
https://www.accesswater.org/?id=-293496CITANCHOR