lastID = -294751
Skip to main content Skip to top navigation Skip to site search
Top of page
  • My citations options
    Web Back (from Web)
    Chicago Back (from Chicago)
    MLA Back (from MLA)
Close action menu

You need to login to use this feature.

Please wait a moment…
Please wait while we update your results...
Please wait a moment...
Description: Access Water
Context Menu
Description: Book cover
The Study on UV Disinfection of Treated Wastewater for Sewage Treatment Plants in Japan
  • Browse
  • Compilations
    • Compilations list
  • Subscriptions
Tools

Related contents

Loading related content

Workflow

No linked records yet

X
  • Current: 2020-02-01 05:30:04 Administrator
  • 2020-02-01 05:30:03 Administrator
Description: Access Water
  • Browse
  • Compilations
  • Subscriptions
Log in
0
Accessibility Options

Base text size -

This is a sample piece of body text
Larger
Smaller
  • Shopping basket (0)
  • Accessibility options
  • Return to previous
Description: Book cover
The Study on UV Disinfection of Treated Wastewater for Sewage Treatment Plants in Japan

The Study on UV Disinfection of Treated Wastewater for Sewage Treatment Plants in Japan

The Study on UV Disinfection of Treated Wastewater for Sewage Treatment Plants in Japan

  • New
  • View
  • Details
  • Reader
  • Default
  • Share
  • Email
  • Facebook
  • Twitter
  • LinkedIn
  • New
  • View
  • Default view
  • Reader view
  • Data view
  • Details

This page cannot be printed from here

Please use the dedicated print option from the 'view' drop down menu located in the blue ribbon in the top, right section of the publication.

screenshot of print menu option

Description: Book cover
The Study on UV Disinfection of Treated Wastewater for Sewage Treatment Plants in Japan
Abstract
The Problem and the Purpose of this studyIn Japan, Treated wastewater has been conventionally treated mainly with chlorine. However, an alternative disinfection technology replacing chlorination is demanded for diverse reasons. For example, special circumstances of water areas (for preservation of rare species) to which treated wastewater are discharged or recycling of treated water for landscape use. There are about 1,900 places sewage treatment plants in Japan, and sewage treatment plants installed ultraviolet (UV) disinfection systems is 90 places of total about around 5%. The following matter is nominated for this reason.□ In Japan, there is little recognition about performance of UV disinfection.□ A technical matter about a plan of UV disinfection facilities, a design, and maintenance is not arranged in our country.This study aims to survey the background and observed effects of sewage treatment plants where UV disinfection systems have already been implemented, and clarify applicability of the UV disinfection technology.The ConclusionApplicabilityA survey was conducted of sewage treatment plants with UV disinfection systems installed, asking for the specific reasons why the UV disinfection technology was selected. About 90 % of the respondents mentioned preservation of aquatic resources and rare species, sources for tap water, and recycling such as for the landscaping use. As for the creature to protect, a sweet fish and laver hold total 30% in marine resources mainly. In addition, a freshwater fish holds a total half. After introduction of UV disinfection facilities, that the fish which were not watched till now came to be seen is evaluated by inhabitants of a basin person concerned. Our study has also defined these reasons as preferential applicable areas of the UV disinfection technology.Design specificationsUV transmittanceTo set the UV transmittance for a design, we actually measured UV transmittance of wastewater at each sewage treatment plant. For installation of a system to a newly constructed plant, we set a UV transmittance of 70% or more as the standard.UV disinfection performanceWhen a UV radiation dose of 300 to 500J/m2 was applied, the coliform count after disinfection was 10/cm3 or less in each sample case. Even if we take into consideration a 30-fold increase of coliform count from photoreactivation, the coliform count can constantly be limited within 3,000/cm3.According to the literature we consulted, the coliform count of wastewater is said to be around 30,000/cm3 at maximum. Considering the increase in the coliform count from photoreactivation, the average disinfection performance must constantly be maintained to within 3,000/cm3. Therefore, we concluded that the average disinfection performance immediately after disinfection should be set to around 99.9% and that a UV radiation dose of 300 to 500J/m2 (from 30 to 50 mWs/cm2) is required to achieve such performance.DesignWe analyzed design methods for open channel UV disinfection systems and closed chamber UV disinfection systems. In this study, we conducted model designing as shown in the reference document as well as sorting out design details of each system.
The Problem and the Purpose of this studyIn Japan, Treated wastewater has been conventionally treated mainly with chlorine. However, an alternative disinfection technology replacing chlorination is demanded for diverse reasons. For example, special circumstances of water areas (for preservation of rare species) to which treated wastewater are discharged or recycling of treated water for landscape...
Author(s)
Yasuaki MatsudaHiroichi MizukawaMasayuki Matsuura
SourceProceedings of the Water Environment Federation
SubjectSession 115: UV Efficiency, Effectiveness and Applications
Document typeConference Paper
PublisherWater Environment Federation
Print publication date Oct, 2007
ISSN1938-6478
SICI1938-6478(20071001)2007:8L.9027;1-
DOI10.2175/193864707787781034
Volume / Issue2007 / 8
Content sourceWEFTEC
First / last page(s)9027 - 9028
Copyright2007
Word count492
Subject keywordsUVDISINFECTIONCOLIFORM

Purchase price $11.50

Get access
Log in Purchase content Purchase subscription
You may already have access to this content if you have previously purchased this content or have a subscription.
Need to create an account?

You can purchase access to this content but you might want to consider a subscription for a wide variety of items at a substantial discount!

Purchase access to 'The Study on UV Disinfection of Treated Wastewater for Sewage Treatment Plants in Japan'

Add to cart
Purchase a subscription to gain access to 18,000+ Proceeding Papers, 25+ Fact Sheets, 20+ Technical Reports, 50+ magazine articles and select Technical Publications' chapters.
Loading items
There are no items to display at the moment.
Something went wrong trying to load these items.
Description: Book cover
The Study on UV Disinfection of Treated Wastewater for Sewage Treatment Plants in Japan
Pricing
Non-member price: $11.50
Member price:
-294751
Get access
-294751
Log in Purchase content Purchase subscription
You may already have access to this content if you have previously purchased this content or have a subscription.
Need to create an account?

You can purchase access to this content but you might want to consider a subscription for a wide variety of items at a substantial discount!

Purchase access to 'The Study on UV Disinfection of Treated Wastewater for Sewage Treatment Plants in Japan'

Add to cart
Purchase a subscription to gain access to 18,000+ Proceeding Papers, 25+ Fact Sheets, 20+ Technical Reports, 50+ magazine articles and select Technical Publications' chapters.

Details

Description: Book cover
The Study on UV Disinfection of Treated Wastewater for Sewage Treatment Plants in Japan
Abstract
The Problem and the Purpose of this studyIn Japan, Treated wastewater has been conventionally treated mainly with chlorine. However, an alternative disinfection technology replacing chlorination is demanded for diverse reasons. For example, special circumstances of water areas (for preservation of rare species) to which treated wastewater are discharged or recycling of treated water for landscape use. There are about 1,900 places sewage treatment plants in Japan, and sewage treatment plants installed ultraviolet (UV) disinfection systems is 90 places of total about around 5%. The following matter is nominated for this reason.□ In Japan, there is little recognition about performance of UV disinfection.□ A technical matter about a plan of UV disinfection facilities, a design, and maintenance is not arranged in our country.This study aims to survey the background and observed effects of sewage treatment plants where UV disinfection systems have already been implemented, and clarify applicability of the UV disinfection technology.The ConclusionApplicabilityA survey was conducted of sewage treatment plants with UV disinfection systems installed, asking for the specific reasons why the UV disinfection technology was selected. About 90 % of the respondents mentioned preservation of aquatic resources and rare species, sources for tap water, and recycling such as for the landscaping use. As for the creature to protect, a sweet fish and laver hold total 30% in marine resources mainly. In addition, a freshwater fish holds a total half. After introduction of UV disinfection facilities, that the fish which were not watched till now came to be seen is evaluated by inhabitants of a basin person concerned. Our study has also defined these reasons as preferential applicable areas of the UV disinfection technology.Design specificationsUV transmittanceTo set the UV transmittance for a design, we actually measured UV transmittance of wastewater at each sewage treatment plant. For installation of a system to a newly constructed plant, we set a UV transmittance of 70% or more as the standard.UV disinfection performanceWhen a UV radiation dose of 300 to 500J/m2 was applied, the coliform count after disinfection was 10/cm3 or less in each sample case. Even if we take into consideration a 30-fold increase of coliform count from photoreactivation, the coliform count can constantly be limited within 3,000/cm3.According to the literature we consulted, the coliform count of wastewater is said to be around 30,000/cm3 at maximum. Considering the increase in the coliform count from photoreactivation, the average disinfection performance must constantly be maintained to within 3,000/cm3. Therefore, we concluded that the average disinfection performance immediately after disinfection should be set to around 99.9% and that a UV radiation dose of 300 to 500J/m2 (from 30 to 50 mWs/cm2) is required to achieve such performance.DesignWe analyzed design methods for open channel UV disinfection systems and closed chamber UV disinfection systems. In this study, we conducted model designing as shown in the reference document as well as sorting out design details of each system.
The Problem and the Purpose of this studyIn Japan, Treated wastewater has been conventionally treated mainly with chlorine. However, an alternative disinfection technology replacing chlorination is demanded for diverse reasons. For example, special circumstances of water areas (for preservation of rare species) to which treated wastewater are discharged or recycling of treated water for landscape...
Author(s)
Yasuaki MatsudaHiroichi MizukawaMasayuki Matsuura
SourceProceedings of the Water Environment Federation
SubjectSession 115: UV Efficiency, Effectiveness and Applications
Document typeConference Paper
PublisherWater Environment Federation
Print publication date Oct, 2007
ISSN1938-6478
SICI1938-6478(20071001)2007:8L.9027;1-
DOI10.2175/193864707787781034
Volume / Issue2007 / 8
Content sourceWEFTEC
First / last page(s)9027 - 9028
Copyright2007
Word count492
Subject keywordsUVDISINFECTIONCOLIFORM

Actions, changes & tasks

Outstanding Actions

Add action for paragraph

Current Changes

Add signficant change

Current Tasks

Add risk task

Connect with us

Follow us on Facebook
Follow us on Twitter
Connect to us on LinkedIn
Subscribe on YouTube
Powered by Librios Ltd
Powered by Librios Ltd
Authors
Terms of Use
Policies
Help
Accessibility
Contact us
Copyright © 2024 by the Water Environment Federation
Loading items
There are no items to display at the moment.
Something went wrong trying to load these items.
Description: WWTF Digital Boot 180x150
WWTF Digital (180x150)
Created on Jul 02
Websitehttps:/­/­www.wef.org/­wwtf?utm_medium=WWTF&utm_source=AccessWater&utm_campaign=WWTF
180x150
Yasuaki Matsuda# Hiroichi Mizukawa# Masayuki Matsuura. The Study on UV Disinfection of Treated Wastewater for Sewage Treatment Plants in Japan. Water Environment Federation, 2018. Web. 2 Jul. 2025. <https://www.accesswater.org?id=-294751CITANCHOR>.
Yasuaki Matsuda# Hiroichi Mizukawa# Masayuki Matsuura. The Study on UV Disinfection of Treated Wastewater for Sewage Treatment Plants in Japan. Water Environment Federation, 2018. Accessed July 2, 2025. https://www.accesswater.org/?id=-294751CITANCHOR.
Yasuaki Matsuda# Hiroichi Mizukawa# Masayuki Matsuura
The Study on UV Disinfection of Treated Wastewater for Sewage Treatment Plants in Japan
Access Water
Water Environment Federation
December 22, 2018
July 2, 2025
https://www.accesswater.org/?id=-294751CITANCHOR