lastID = -295601
Skip to main content Skip to top navigation Skip to site search
Top of page
  • My citations options
    Web Back (from Web)
    Chicago Back (from Chicago)
    MLA Back (from MLA)
Close action menu

You need to login to use this feature.

Please wait a moment…
Please wait while we update your results...
Please wait a moment...
Description: Access Water
Context Menu
Description: Book cover
Odour Sampling Methods for Point, Area, Fugitive, and Ambient Sources
  • Browse
  • Compilations
    • Compilations list
  • Subscriptions
Tools

Related contents

Loading related content

Workflow

No linked records yet

X
  • Current: 2020-03-27 00:02:59 Adam Phillips
  • 2020-03-27 00:02:58 Adam Phillips
  • 2020-02-01 02:18:36 Administrator
  • 2020-02-01 02:18:35 Administrator
Description: Access Water
  • Browse
  • Compilations
  • Subscriptions
Log in
0
Accessibility Options

Base text size -

This is a sample piece of body text
Larger
Smaller
  • Shopping basket (0)
  • Accessibility options
  • Return to previous
Description: Book cover
Odour Sampling Methods for Point, Area, Fugitive, and Ambient Sources

Odour Sampling Methods for Point, Area, Fugitive, and Ambient Sources

Odour Sampling Methods for Point, Area, Fugitive, and Ambient Sources

  • New
  • View
  • Details
  • Reader
  • Default
  • Share
  • Email
  • Facebook
  • Twitter
  • LinkedIn
  • New
  • View
  • Default view
  • Reader view
  • Data view
  • Details

This page cannot be printed from here

Please use the dedicated print option from the 'view' drop down menu located in the blue ribbon in the top, right section of the publication.

screenshot of print menu option

Description: Book cover
Odour Sampling Methods for Point, Area, Fugitive, and Ambient Sources
Abstract
There is still some confusion about standard sampling methods regarding odours. There are standard methods for specific contaminants such as particulate and volatile organic compounds, but there is no specific standard method, especially in the United States, for odour sampling. In Canada, there is a Draft Ontario Ministry of Environmental Method (Source Sampling for Odours, version 2, 1989), however this method is inadequate and the Ontario Ministry of the Environment is in the process of updating this method. Even European (EN13725;2003) and Australian/New Zealand (AS/NZS 4323.3:2001) odour standards do not specify their sampling methodology except in general terms, such as; using static or dynamic dilution for point sources sampling, flux hood method or wind tunnel methods for area sampling. These standards still allow static dilution and do not specify the number of samples collected per source, the sampling time, or any other important factors, which might affect the final results. These methods are designed more for odour evaluation than for odour sampling, and the results accuracy should be seriously questioned, when you consider that there is no set standard method for odour sampling.In the United States, sampling for odours is limited either to measuring ambient levels using a scentometer or other portable unit, or by sampling at point sources without dilution with a minimum number (sometimes one or two) samples per location/source. This paper will emphasize the following issues; the importance of dynamic dilution when sampling at point sources, especially when the source is hot and the odour lost during sampling can be up to sixteen times greater, when an appropriate method is not applied. The results for both the dilution technique and an undiluted technique will be compared and will show the loss of odorants when samples are not diluted. Secondly, this paper will compare two methods for sampling area sources and will compare the results obtained by sampling at area sources with both a Standard Flux Chamber and a Portable Wind Tunnel at the same source, and at the same time.A brief description of sampling for fugitive sources will be also introduced, but due to the complexity of sampling for fugitive sources, a separate paper is being prepared. This paper will also concentrate on sampling ambient odour levels using comparisons of an actual sampling downwind from a facility using the lung methodology. This method will be compared with those obtained from Nasal Ranger readings performed at the same time and at the same location.This paper will demonstrate the importance of proper sampling at point sources, area and fugitive sources or for ambient levels.
There is still some confusion about standard sampling methods regarding odours. There are standard methods for specific contaminants such as particulate and volatile organic compounds, but there is no specific standard method, especially in the United States, for odour sampling. In Canada, there is a Draft Ontario Ministry of Environmental Method (Source Sampling for Odours, version 2, 1989),...
Author(s)
Anna H. Bokowa
SourceProceedings of the Water Environment Federation
SubjectSession 8: Methods of Sampling, Measuring, and Estimating Emissions II
Document typeConference Paper
PublisherWater Environment Federation
Print publication date Jan, 2008
ISSN1938-6478
SICI1938-6478(20080101)2008:4L.577;1-
DOI10.2175/193864708788808041
Volume / Issue2008 / 4
Content sourceOdors and Air Pollutants Conference
First / last page(s)577 - 589
Copyright2008
Word count435

Purchase price $11.50

Get access
Log in Purchase content Purchase subscription
You may already have access to this content if you have previously purchased this content or have a subscription.
Need to create an account?

You can purchase access to this content but you might want to consider a subscription for a wide variety of items at a substantial discount!

Purchase access to 'Odour Sampling Methods for Point, Area, Fugitive, and Ambient Sources'

Add to cart
Purchase a subscription to gain access to 18,000+ Proceeding Papers, 25+ Fact Sheets, 20+ Technical Reports, 50+ magazine articles and select Technical Publications' chapters.
Loading items
There are no items to display at the moment.
Something went wrong trying to load these items.
Description: Book cover
Odour Sampling Methods for Point, Area, Fugitive, and Ambient Sources
Pricing
Non-member price: $11.50
Member price:
-295601
Get access
-295601
Log in Purchase content Purchase subscription
You may already have access to this content if you have previously purchased this content or have a subscription.
Need to create an account?

You can purchase access to this content but you might want to consider a subscription for a wide variety of items at a substantial discount!

Purchase access to 'Odour Sampling Methods for Point, Area, Fugitive, and Ambient Sources'

Add to cart
Purchase a subscription to gain access to 18,000+ Proceeding Papers, 25+ Fact Sheets, 20+ Technical Reports, 50+ magazine articles and select Technical Publications' chapters.

Details

Description: Book cover
Odour Sampling Methods for Point, Area, Fugitive, and Ambient Sources
Abstract
There is still some confusion about standard sampling methods regarding odours. There are standard methods for specific contaminants such as particulate and volatile organic compounds, but there is no specific standard method, especially in the United States, for odour sampling. In Canada, there is a Draft Ontario Ministry of Environmental Method (Source Sampling for Odours, version 2, 1989), however this method is inadequate and the Ontario Ministry of the Environment is in the process of updating this method. Even European (EN13725;2003) and Australian/New Zealand (AS/NZS 4323.3:2001) odour standards do not specify their sampling methodology except in general terms, such as; using static or dynamic dilution for point sources sampling, flux hood method or wind tunnel methods for area sampling. These standards still allow static dilution and do not specify the number of samples collected per source, the sampling time, or any other important factors, which might affect the final results. These methods are designed more for odour evaluation than for odour sampling, and the results accuracy should be seriously questioned, when you consider that there is no set standard method for odour sampling.In the United States, sampling for odours is limited either to measuring ambient levels using a scentometer or other portable unit, or by sampling at point sources without dilution with a minimum number (sometimes one or two) samples per location/source. This paper will emphasize the following issues; the importance of dynamic dilution when sampling at point sources, especially when the source is hot and the odour lost during sampling can be up to sixteen times greater, when an appropriate method is not applied. The results for both the dilution technique and an undiluted technique will be compared and will show the loss of odorants when samples are not diluted. Secondly, this paper will compare two methods for sampling area sources and will compare the results obtained by sampling at area sources with both a Standard Flux Chamber and a Portable Wind Tunnel at the same source, and at the same time.A brief description of sampling for fugitive sources will be also introduced, but due to the complexity of sampling for fugitive sources, a separate paper is being prepared. This paper will also concentrate on sampling ambient odour levels using comparisons of an actual sampling downwind from a facility using the lung methodology. This method will be compared with those obtained from Nasal Ranger readings performed at the same time and at the same location.This paper will demonstrate the importance of proper sampling at point sources, area and fugitive sources or for ambient levels.
There is still some confusion about standard sampling methods regarding odours. There are standard methods for specific contaminants such as particulate and volatile organic compounds, but there is no specific standard method, especially in the United States, for odour sampling. In Canada, there is a Draft Ontario Ministry of Environmental Method (Source Sampling for Odours, version 2, 1989),...
Author(s)
Anna H. Bokowa
SourceProceedings of the Water Environment Federation
SubjectSession 8: Methods of Sampling, Measuring, and Estimating Emissions II
Document typeConference Paper
PublisherWater Environment Federation
Print publication date Jan, 2008
ISSN1938-6478
SICI1938-6478(20080101)2008:4L.577;1-
DOI10.2175/193864708788808041
Volume / Issue2008 / 4
Content sourceOdors and Air Pollutants Conference
First / last page(s)577 - 589
Copyright2008
Word count435

Actions, changes & tasks

Outstanding Actions

Add action for paragraph

Current Changes

Add signficant change

Current Tasks

Add risk task

Connect with us

Follow us on Facebook
Follow us on Twitter
Connect to us on LinkedIn
Subscribe on YouTube
Powered by Librios Ltd
Powered by Librios Ltd
Authors
Terms of Use
Policies
Help
Accessibility
Contact us
Copyright © 2024 by the Water Environment Federation
Loading items
There are no items to display at the moment.
Something went wrong trying to load these items.
Description: WWTF Digital Boot 180x150
WWTF Digital (180x150)
Created on Jul 02
Websitehttps:/­/­www.wef.org/­wwtf?utm_medium=WWTF&utm_source=AccessWater&utm_campaign=WWTF
180x150
Anna H. Bokowa. Odour Sampling Methods for Point, Area, Fugitive, and Ambient Sources. Alexandria, VA 22314-1994, USA: Water Environment Federation, 2018. Web. 12 Jun. 2025. <https://www.accesswater.org?id=-295601CITANCHOR>.
Anna H. Bokowa. Odour Sampling Methods for Point, Area, Fugitive, and Ambient Sources. Alexandria, VA 22314-1994, USA: Water Environment Federation, 2018. Accessed June 12, 2025. https://www.accesswater.org/?id=-295601CITANCHOR.
Anna H. Bokowa
Odour Sampling Methods for Point, Area, Fugitive, and Ambient Sources
Access Water
Water Environment Federation
December 22, 2018
June 12, 2025
https://www.accesswater.org/?id=-295601CITANCHOR