lastID = -295653
Skip to main content Skip to top navigation Skip to site search
Top of page
  • My citations options
    Web Back (from Web)
    Chicago Back (from Chicago)
    MLA Back (from MLA)
Close action menu

You need to login to use this feature.

Please wait a moment…
Please wait while we update your results...
Please wait a moment...
Description: Access Water
Context Menu
Description: Book cover
Dual Phase Collection System Odor Investigations: The Liquid Phase Might Not Be Enough!
  • Browse
  • Compilations
    • Compilations list
  • Subscriptions
Tools

Related contents

Loading related content

Workflow

No linked records yet

X
  • Current: 2022-05-04 21:22:04 Adam Phillips
  • 2020-03-26 22:09:40 Adam Phillips
  • 2020-01-31 22:12:35 Administrator
  • 2020-01-31 22:12:34 Administrator
  • 2020-01-31 22:12:33 Administrator
Description: Access Water
  • Browse
  • Compilations
  • Subscriptions
Log in
0
Accessibility Options

Base text size -

This is a sample piece of body text
Larger
Smaller
  • Shopping basket (0)
  • Accessibility options
  • Return to previous
Description: Book cover
Dual Phase Collection System Odor Investigations: The Liquid Phase Might Not Be Enough!

Dual Phase Collection System Odor Investigations: The Liquid Phase Might Not Be Enough!

Dual Phase Collection System Odor Investigations: The Liquid Phase Might Not Be Enough!

  • New
  • View
  • Details
  • Reader
  • Default
  • Share
  • Email
  • Facebook
  • Twitter
  • LinkedIn
  • New
  • View
  • Default view
  • Reader view
  • Data view
  • Details

This page cannot be printed from here

Please use the dedicated print option from the 'view' drop down menu located in the blue ribbon in the top, right section of the publication.

screenshot of print menu option

Description: Book cover
Dual Phase Collection System Odor Investigations: The Liquid Phase Might Not Be Enough!
Abstract
It is a well known fact that investigations of odor production in gravity fed sanitary sewers often involve the need for a full understanding of the liquid phase causes of dissolved sulfide production. Related parameters that are typically investigated include wastewater temperature, pH, existing dissolved sulfide concentration and BOD5.The question that is rarely answered in these investigations and studies is, “What is causing odorous air to be forced from the gravity collection system?” Without a full understanding of the headspace ventilation and air pressure characteristics of the sewer system, a permanent odor control solution might not be possible. This presentation will focus on a case study from a recent project in which both liquid phase odor production parameters and headspace ventilation and air pressure characteristics were quantified. Analytical techniques and methods will be presented along with the data from these projects that resulted in the implementation of successful odor control solutions.Figure 1 presents an example of typical air pressure data that was gathered on a recent sanitary sewer odor control project in New Mexico.The air pressure data shown in Figure 1 was taken in a manhole that was a known source of odor complaints and positive sewer headspace air pressure. This had been determined by desktop analysis and subsequently confirmed by air pressure testing. An in-ground biofilter was designed and built near the location of the manhole to remove odorous air from the gravity sewer and treat it through wood-chip media. Two blowers were installed for the biofilter: one duty and one standby. As shown in Figure 1, the natural air pressure in the manhole (with no blowers running) was upwards of 0.15 inches of water column, which resulted in odorous air being forced from the sewer to atmosphere on a daily basis. When Blower 1 is turned on, the air pressure immediately is reduced to −0.5 inches of water column. Blowers 1 and 2 working simultaneously result in an air pressure value of −0.8 inches of water column. When both blowers are turned off the air pressure immediately returns to approximately 0.15 inches of water column.The paper will show that this type of analysis is a valuable tool in identifying the ultimate source of odor release in a gravity fed collection system and designing the proper odor control ventilation systems to ensure that odors are no longer released from the sewer pipes.
It is a well known fact that investigations of odor production in gravity fed sanitary sewers often involve the need for a full understanding of the liquid phase causes of dissolved sulfide production. Related parameters that are typically investigated include wastewater temperature, pH, existing dissolved sulfide concentration and BOD5.The question that is rarely answered in these investigations...
Author(s)
Mark M. Smith
SourceProceedings of the Water Environment Federation
SubjectSession 6: Getting the Best Out of Your Rehabilitation Efforts
Document typeConference Paper
PublisherWater Environment Federation
Print publication date Jan, 2008
ISSN1938-6478
SICI1938-6478(20080101)2008:5L.401;1-
DOI10.2175/193864708788812938
Volume / Issue2008 / 5
Content sourceCollection Systems Conference
First / last page(s)401 - 416
Copyright2008
Word count407

Purchase price $11.50

Get access
Log in Purchase content Purchase subscription
You may already have access to this content if you have previously purchased this content or have a subscription.
Need to create an account?

You can purchase access to this content but you might want to consider a subscription for a wide variety of items at a substantial discount!

Purchase access to 'Dual Phase Collection System Odor Investigations: The Liquid Phase Might Not Be Enough!'

Add to cart
Purchase a subscription to gain access to 18,000+ Proceeding Papers, 25+ Fact Sheets, 20+ Technical Reports, 50+ magazine articles and select Technical Publications' chapters.
Loading items
There are no items to display at the moment.
Something went wrong trying to load these items.
Description: Book cover
Dual Phase Collection System Odor Investigations: The Liquid Phase Might Not Be Enough!
Pricing
Non-member price: $11.50
Member price:
-295653
Get access
-295653
Log in Purchase content Purchase subscription
You may already have access to this content if you have previously purchased this content or have a subscription.
Need to create an account?

You can purchase access to this content but you might want to consider a subscription for a wide variety of items at a substantial discount!

Purchase access to 'Dual Phase Collection System Odor Investigations: The Liquid Phase Might Not Be Enough!'

Add to cart
Purchase a subscription to gain access to 18,000+ Proceeding Papers, 25+ Fact Sheets, 20+ Technical Reports, 50+ magazine articles and select Technical Publications' chapters.

Details

Description: Book cover
Dual Phase Collection System Odor Investigations: The Liquid Phase Might Not Be Enough!
Abstract
It is a well known fact that investigations of odor production in gravity fed sanitary sewers often involve the need for a full understanding of the liquid phase causes of dissolved sulfide production. Related parameters that are typically investigated include wastewater temperature, pH, existing dissolved sulfide concentration and BOD5.The question that is rarely answered in these investigations and studies is, “What is causing odorous air to be forced from the gravity collection system?” Without a full understanding of the headspace ventilation and air pressure characteristics of the sewer system, a permanent odor control solution might not be possible. This presentation will focus on a case study from a recent project in which both liquid phase odor production parameters and headspace ventilation and air pressure characteristics were quantified. Analytical techniques and methods will be presented along with the data from these projects that resulted in the implementation of successful odor control solutions.Figure 1 presents an example of typical air pressure data that was gathered on a recent sanitary sewer odor control project in New Mexico.The air pressure data shown in Figure 1 was taken in a manhole that was a known source of odor complaints and positive sewer headspace air pressure. This had been determined by desktop analysis and subsequently confirmed by air pressure testing. An in-ground biofilter was designed and built near the location of the manhole to remove odorous air from the gravity sewer and treat it through wood-chip media. Two blowers were installed for the biofilter: one duty and one standby. As shown in Figure 1, the natural air pressure in the manhole (with no blowers running) was upwards of 0.15 inches of water column, which resulted in odorous air being forced from the sewer to atmosphere on a daily basis. When Blower 1 is turned on, the air pressure immediately is reduced to −0.5 inches of water column. Blowers 1 and 2 working simultaneously result in an air pressure value of −0.8 inches of water column. When both blowers are turned off the air pressure immediately returns to approximately 0.15 inches of water column.The paper will show that this type of analysis is a valuable tool in identifying the ultimate source of odor release in a gravity fed collection system and designing the proper odor control ventilation systems to ensure that odors are no longer released from the sewer pipes.
It is a well known fact that investigations of odor production in gravity fed sanitary sewers often involve the need for a full understanding of the liquid phase causes of dissolved sulfide production. Related parameters that are typically investigated include wastewater temperature, pH, existing dissolved sulfide concentration and BOD5.The question that is rarely answered in these investigations...
Author(s)
Mark M. Smith
SourceProceedings of the Water Environment Federation
SubjectSession 6: Getting the Best Out of Your Rehabilitation Efforts
Document typeConference Paper
PublisherWater Environment Federation
Print publication date Jan, 2008
ISSN1938-6478
SICI1938-6478(20080101)2008:5L.401;1-
DOI10.2175/193864708788812938
Volume / Issue2008 / 5
Content sourceCollection Systems Conference
First / last page(s)401 - 416
Copyright2008
Word count407

Actions, changes & tasks

Outstanding Actions

Add action for paragraph

Current Changes

Add signficant change

Current Tasks

Add risk task

Connect with us

Follow us on Facebook
Follow us on Twitter
Connect to us on LinkedIn
Subscribe on YouTube
Powered by Librios Ltd
Powered by Librios Ltd
Authors
Terms of Use
Policies
Help
Accessibility
Contact us
Copyright © 2024 by the Water Environment Federation
Loading items
There are no items to display at the moment.
Something went wrong trying to load these items.
Description: WWTF Digital Boot 180x150
WWTF Digital (180x150)
Created on Jul 02
Websitehttps:/­/­www.wef.org/­wwtf?utm_medium=WWTF&utm_source=AccessWater&utm_campaign=WWTF
180x150
Mark M. Smith. Dual Phase Collection System Odor Investigations: The Liquid Phase Might Not Be Enough!. Alexandria, VA 22314-1994, USA: Water Environment Federation, 2018. Web. 6 Jun. 2025. <https://www.accesswater.org?id=-295653CITANCHOR>.
Mark M. Smith. Dual Phase Collection System Odor Investigations: The Liquid Phase Might Not Be Enough!. Alexandria, VA 22314-1994, USA: Water Environment Federation, 2018. Accessed June 6, 2025. https://www.accesswater.org/?id=-295653CITANCHOR.
Mark M. Smith
Dual Phase Collection System Odor Investigations: The Liquid Phase Might Not Be Enough!
Access Water
Water Environment Federation
December 22, 2018
June 6, 2025
https://www.accesswater.org/?id=-295653CITANCHOR