lastID = -297780
Skip to main content Skip to top navigation Skip to site search
Top of page
  • My citations options
    Web Back (from Web)
    Chicago Back (from Chicago)
    MLA Back (from MLA)
Close action menu

You need to login to use this feature.

Please wait a moment…
Please wait while we update your results...
Please wait a moment...
Description: Access Water
Context Menu
Description: Book cover
North Head STP:-The Innovative Application of Venturi Technology. Providing Enhanced Operational Security, Process Performance, and Minimising Chemical Consumption
  • Browse
  • Compilations
    • Compilations list
  • Subscriptions
Tools

Related contents

Loading related content

Workflow

No linked records yet

X
  • Current: 2022-06-14 20:33:38 Adam Phillips
  • 2022-06-14 20:33:35 Adam Phillips
  • 2020-03-27 00:01:49 Adam Phillips
  • 2020-02-01 02:03:25 Administrator
  • 2020-02-01 02:03:24 Administrator
Description: Access Water
  • Browse
  • Compilations
  • Subscriptions
Log in
0
Accessibility Options

Base text size -

This is a sample piece of body text
Larger
Smaller
  • Shopping basket (0)
  • Accessibility options
  • Return to previous
Description: Book cover
North Head STP:-The Innovative Application of Venturi Technology. Providing Enhanced Operational Security, Process Performance, and Minimising Chemical Consumption

North Head STP:-The Innovative Application of Venturi Technology. Providing Enhanced Operational Security, Process Performance, and Minimising Chemical Consumption

North Head STP:-The Innovative Application of Venturi Technology. Providing Enhanced Operational Security, Process Performance, and Minimising Chemical Consumption

  • New
  • View
  • Details
  • Reader
  • Default
  • Share
  • Email
  • Facebook
  • Twitter
  • LinkedIn
  • New
  • View
  • Default view
  • Reader view
  • Data view
  • Details

This page cannot be printed from here

Please use the dedicated print option from the 'view' drop down menu located in the blue ribbon in the top, right section of the publication.

screenshot of print menu option

Description: Book cover
North Head STP:-The Innovative Application of Venturi Technology. Providing Enhanced Operational Security, Process Performance, and Minimising Chemical Consumption
Abstract
North Head STP is located in Sydney, Australia, and provides high rate primary treatment to a population equivalent of 1.2millon people. Historically odour control for both the liquid and biosolids streams at the plant was provided by conventional packed tower scrubbing systems. These systems were overloaded, and suffered from associated operational problems placing the plant operating licence at risk.To resolve these issues Sydney Water commissioned the Central Odour Control Facility (COCF) Project. The COCF consists of the three stage wet chemical scrubbing system treating 43,000m3/hr (25,310 ft3/min) of foul air. The first stage is a venturi scrubber, designed to operate under modified process conditions to minimise chemical consumption. The second stage packed tower is a caustic/hypochlorite system coupled to an Odorgard™ reactor. The final stage has the ability to operate as either a caustic scrubber for final polishing, or as a conventional caustic/hypochlorite scrubber.The automated control system allows the three stages to re-configure the scrubbing system, between series or parallel operation, to increase treatment capacity from a peak hydrogen sulphide concentration of 292ppmv to over 600 ppmv.The venturi chemical re-use system, combined with a control system to modify process chemistry in the venturi, reduces hypochlorite consumption in the first stage by up to 75% compared to a conventional packed tower under the same duty. Overall the COCF saves between 30 to 40% of feedstock chemical(as compared to a conventional system), resulting in annual operational saving to Sydney Water of 220,000 (USD) due to the reduction in chemical consumption alone.The COCF successfully completed a 3 month performance test in the summer of 2008–2009. This paper describes the design features of the COCF and the reviews the plant's operation during the performance test period.
North Head STP is located in Sydney, Australia, and provides high rate primary treatment to a population equivalent of 1.2millon people. Historically odour control for both the liquid and biosolids streams at the plant was provided by conventional packed tower scrubbing systems. These systems were overloaded, and suffered from associated operational problems placing the plant operating licence at...
Author(s)
Paul KynastonIan EvansonRod Mackenzie
SourceProceedings of the Water Environment Federation
SubjectArticles
Document typeConference Paper
PublisherWater Environment Federation
Print publication date Jan, 2010
ISSN1938-6478
SICI1938-6478(20100101)2010:3L.571;1-
DOI10.2175/193864710802768037
Volume / Issue2010 / 3
Content sourceOdors and Air Pollutants Conference
First / last page(s)571 - 593
Copyright2010
Word count301
Subject keywordsVenturipacked towersodorgard reactorelemental sulphur depositionchemical reuseadvanced control

Purchase price $11.50

Get access
Log in Purchase content Purchase subscription
You may already have access to this content if you have previously purchased this content or have a subscription.
Need to create an account?

You can purchase access to this content but you might want to consider a subscription for a wide variety of items at a substantial discount!

Purchase access to 'North Head STP:-The Innovative Application of Venturi Technology. Providing Enhanced Operational Security, Process Performance, and Minimising Chemical Consumption'

Add to cart
Purchase a subscription to gain access to 18,000+ Proceeding Papers, 25+ Fact Sheets, 20+ Technical Reports, 50+ magazine articles and select Technical Publications' chapters.
Loading items
There are no items to display at the moment.
Something went wrong trying to load these items.
Description: Book cover
North Head STP:-The Innovative Application of Venturi Technology. Providing Enhanced Operational Security, Process Performance, and Minimising Chemical Consumption
Pricing
Non-member price: $11.50
Member price:
-297780
Get access
-297780
Log in Purchase content Purchase subscription
You may already have access to this content if you have previously purchased this content or have a subscription.
Need to create an account?

You can purchase access to this content but you might want to consider a subscription for a wide variety of items at a substantial discount!

Purchase access to 'North Head STP:-The Innovative Application of Venturi Technology. Providing Enhanced Operational Security, Process Performance, and Minimising Chemical Consumption'

Add to cart
Purchase a subscription to gain access to 18,000+ Proceeding Papers, 25+ Fact Sheets, 20+ Technical Reports, 50+ magazine articles and select Technical Publications' chapters.

Details

Description: Book cover
North Head STP:-The Innovative Application of Venturi Technology. Providing Enhanced Operational Security, Process Performance, and Minimising Chemical Consumption
Abstract
North Head STP is located in Sydney, Australia, and provides high rate primary treatment to a population equivalent of 1.2millon people. Historically odour control for both the liquid and biosolids streams at the plant was provided by conventional packed tower scrubbing systems. These systems were overloaded, and suffered from associated operational problems placing the plant operating licence at risk.To resolve these issues Sydney Water commissioned the Central Odour Control Facility (COCF) Project. The COCF consists of the three stage wet chemical scrubbing system treating 43,000m3/hr (25,310 ft3/min) of foul air. The first stage is a venturi scrubber, designed to operate under modified process conditions to minimise chemical consumption. The second stage packed tower is a caustic/hypochlorite system coupled to an Odorgard™ reactor. The final stage has the ability to operate as either a caustic scrubber for final polishing, or as a conventional caustic/hypochlorite scrubber.The automated control system allows the three stages to re-configure the scrubbing system, between series or parallel operation, to increase treatment capacity from a peak hydrogen sulphide concentration of 292ppmv to over 600 ppmv.The venturi chemical re-use system, combined with a control system to modify process chemistry in the venturi, reduces hypochlorite consumption in the first stage by up to 75% compared to a conventional packed tower under the same duty. Overall the COCF saves between 30 to 40% of feedstock chemical(as compared to a conventional system), resulting in annual operational saving to Sydney Water of 220,000 (USD) due to the reduction in chemical consumption alone.The COCF successfully completed a 3 month performance test in the summer of 2008–2009. This paper describes the design features of the COCF and the reviews the plant's operation during the performance test period.
North Head STP is located in Sydney, Australia, and provides high rate primary treatment to a population equivalent of 1.2millon people. Historically odour control for both the liquid and biosolids streams at the plant was provided by conventional packed tower scrubbing systems. These systems were overloaded, and suffered from associated operational problems placing the plant operating licence at...
Author(s)
Paul KynastonIan EvansonRod Mackenzie
SourceProceedings of the Water Environment Federation
SubjectArticles
Document typeConference Paper
PublisherWater Environment Federation
Print publication date Jan, 2010
ISSN1938-6478
SICI1938-6478(20100101)2010:3L.571;1-
DOI10.2175/193864710802768037
Volume / Issue2010 / 3
Content sourceOdors and Air Pollutants Conference
First / last page(s)571 - 593
Copyright2010
Word count301
Subject keywordsVenturipacked towersodorgard reactorelemental sulphur depositionchemical reuseadvanced control

Actions, changes & tasks

Outstanding Actions

Add action for paragraph

Current Changes

Add signficant change

Current Tasks

Add risk task

Connect with us

Follow us on Facebook
Follow us on Twitter
Connect to us on LinkedIn
Subscribe on YouTube
Powered by Librios Ltd
Powered by Librios Ltd
Authors
Terms of Use
Policies
Help
Accessibility
Contact us
Copyright © 2024 by the Water Environment Federation
Loading items
There are no items to display at the moment.
Something went wrong trying to load these items.
Description: WWTF Digital Boot 180x150
WWTF Digital (180x150)
Created on Jul 02
Websitehttps:/­/­www.wef.org/­wwtf?utm_medium=WWTF&utm_source=AccessWater&utm_campaign=WWTF
180x150
Paul Kynaston# Ian Evanson# Rod Mackenzie. North Head STP:-The Innovative Application of Venturi Technology. Providing Enhanced Operational Security, Process Performance, and Minimising Chemical Consumption. Alexandria, VA 22314-1994, USA: Water Environment Federation, 2018. Web. 9 Jul. 2025. <https://www.accesswater.org?id=-297780CITANCHOR>.
Paul Kynaston# Ian Evanson# Rod Mackenzie. North Head STP:-The Innovative Application of Venturi Technology. Providing Enhanced Operational Security, Process Performance, and Minimising Chemical Consumption. Alexandria, VA 22314-1994, USA: Water Environment Federation, 2018. Accessed July 9, 2025. https://www.accesswater.org/?id=-297780CITANCHOR.
Paul Kynaston# Ian Evanson# Rod Mackenzie
North Head STP:-The Innovative Application of Venturi Technology. Providing Enhanced Operational Security, Process Performance, and Minimising Chemical Consumption
Access Water
Water Environment Federation
December 22, 2018
July 9, 2025
https://www.accesswater.org/?id=-297780CITANCHOR