lastID = -297788
Skip to main content Skip to top navigation Skip to site search
Top of page
  • My citations options
    Web Back (from Web)
    Chicago Back (from Chicago)
    MLA Back (from MLA)
Close action menu

You need to login to use this feature.

Please wait a moment…
Please wait while we update your results...
Please wait a moment...
Description: Access Water
Context Menu
Description: Book cover
Columbus Discovers a Greener Odor Control Approach
  • Browse
  • Compilations
    • Compilations list
  • Subscriptions
Tools

Related contents

Loading related content

Workflow

No linked records yet

X
  • Current: 2022-06-14 20:25:03 Adam Phillips
  • 2022-06-14 20:25:02 Adam Phillips
  • 2020-03-27 00:01:42 Adam Phillips
  • 2020-03-27 00:01:41 Adam Phillips
  • 2020-01-31 21:05:43 Administrator
  • 2020-01-31 21:05:42 Administrator
Description: Access Water
  • Browse
  • Compilations
  • Subscriptions
Log in
0
Accessibility Options

Base text size -

This is a sample piece of body text
Larger
Smaller
  • Shopping basket (0)
  • Accessibility options
  • Return to previous
Description: Book cover
Columbus Discovers a Greener Odor Control Approach

Columbus Discovers a Greener Odor Control Approach

Columbus Discovers a Greener Odor Control Approach

  • New
  • View
  • Details
  • Reader
  • Default
  • Share
  • Email
  • Facebook
  • Twitter
  • LinkedIn
  • New
  • View
  • Default view
  • Reader view
  • Data view
  • Details

This page cannot be printed from here

Please use the dedicated print option from the 'view' drop down menu located in the blue ribbon in the top, right section of the publication.

screenshot of print menu option

Description: Book cover
Columbus Discovers a Greener Odor Control Approach
Abstract
To reduce overflows of untreated wastewater into area waterways, the City of Columbus constructed a large capacity sewer (13-foot diameter) to provide up to 60 million gallons of storage (equivalent to the projected wet weather flow from a 1-year storm event) and connected it to a new headworks facility at the Southerly Wastewater Treatment Plant that was designed to pump and treat over 400-mgd. To address the anticipated high hydrogen sulfide and odor concentrations from the collection system, the new headworks required a proven and effective odor control technology that would reduce any nuisance odors from being perceived off-site. The goals established by the City regarding the odor control system were:No odors at the plant fencelineDesign odor control for the health and safety of the facility operatorsApply a proven odor control technologyProvide redundancy to preclude odor control system down-timeThe odor control challenges were characterizing the sewer and new headworks odor potentials and selecting the most cost-viable technology to comply with these goals.Odor assessment investigations were conducted to characterize odor conditions in the collection system and at the pre-existing headworks area of the WWTP. As a result of the collection system being redesigned to handle and store wet weather flows, it was anticipated the potential for hydrogen sulfide generation and release, due to this greater detention time and deposition of solids, would be increased. Site measurements showed a range of hydrogen sulfideconcentrations from 1 to 160-ppmv. Field measurements and office calculations were used to establish the overall odor control system design average and peak concentrations of hydrogen sulfide as 3.5 and 33-ppmv, respectively. Other reduced sulfur compounds were present, but at considerably lower levels. The volume of air required, to provide effective capture and containment of the odors, was approximately 100,000 cfm.Four odor control technologies were evaluated (wet scrubbing, carbon adsorption, biofiltration, and biotrickling filter) and biotrickling filters were selected based on:lower operating costsno chemicals used/stored/handledno hazardous residualsgreener, sustainable operationless maintenance laboreffective treatment of design odor loadsOnce selected, the City of Columbus installed the largest stand-alone biotrickling filter system (provided by Bioway) for odor treatment in North America. The system was designed to treat 96,000 cfm of odorous air.The biotrickling odor control system consists of ten towers fed by a central fan system. The fan system pulls the odorous air through a carefully designed combination of main and branch ducts and pushes it through the ten towers. The treated air is exhausted through a stack at the top of each of the towers. The multiple towers were designed to manage the varying hydrogen sulfide concentrations and other reduced sulfur compounds associated with raw influent wastewater.Extensive process performance trials were conducted and the biotrickling filter system was found to have exceeded its design performance requirements. The system demonstrated 96% removal of odors, taking the average exhaust odor concentration to less than 300 odor units. The odor control system has proved to be robust and has coped well with the varying seasonal odor loads experienced in central Ohio over the past nearly two years of operation (the new headworks building with odor control system was placed into operation in March 2008).This paper will present the odor control technologies that were evaluated, review the biotrickling filter system and present performance data.
To reduce overflows of untreated wastewater into area waterways, the City of Columbus constructed a large capacity sewer (13-foot diameter) to provide up to 60 million gallons of storage (equivalent to the projected wet weather flow from a 1-year storm event) and connected it to a new headworks facility at the Southerly Wastewater Treatment Plant that was designed to pump and treat over 400-mgd....
Author(s)
Chester M. MortonRichard J. PopeRichard A. ReinholdBart KraakmanSteve MessChad Dunn
SourceProceedings of the Water Environment Federation
SubjectArticles
Document typeConference Paper
PublisherWater Environment Federation
Print publication date Jan, 2010
ISSN1938-6478
SICI1938-6478(20100101)2010:3L.671;1-
DOI10.2175/193864710802768046
Volume / Issue2010 / 3
Content sourceOdors and Air Pollutants Conference
First / last page(s)671 - 690
Copyright2010
Word count556
Subject keywordsHeadworksbio-trickling filterhydrogen sulfideodor concentrationdilution-to-threshold

Purchase price $11.50

Get access
Log in Purchase content Purchase subscription
You may already have access to this content if you have previously purchased this content or have a subscription.
Need to create an account?

You can purchase access to this content but you might want to consider a subscription for a wide variety of items at a substantial discount!

Purchase access to 'Columbus Discovers a Greener Odor Control Approach'

Add to cart
Purchase a subscription to gain access to 18,000+ Proceeding Papers, 25+ Fact Sheets, 20+ Technical Reports, 50+ magazine articles and select Technical Publications' chapters.
Loading items
There are no items to display at the moment.
Something went wrong trying to load these items.
Description: Book cover
Columbus Discovers a Greener Odor Control Approach
Pricing
Non-member price: $11.50
Member price:
-297788
Get access
-297788
Log in Purchase content Purchase subscription
You may already have access to this content if you have previously purchased this content or have a subscription.
Need to create an account?

You can purchase access to this content but you might want to consider a subscription for a wide variety of items at a substantial discount!

Purchase access to 'Columbus Discovers a Greener Odor Control Approach'

Add to cart
Purchase a subscription to gain access to 18,000+ Proceeding Papers, 25+ Fact Sheets, 20+ Technical Reports, 50+ magazine articles and select Technical Publications' chapters.

Details

Description: Book cover
Columbus Discovers a Greener Odor Control Approach
Abstract
To reduce overflows of untreated wastewater into area waterways, the City of Columbus constructed a large capacity sewer (13-foot diameter) to provide up to 60 million gallons of storage (equivalent to the projected wet weather flow from a 1-year storm event) and connected it to a new headworks facility at the Southerly Wastewater Treatment Plant that was designed to pump and treat over 400-mgd. To address the anticipated high hydrogen sulfide and odor concentrations from the collection system, the new headworks required a proven and effective odor control technology that would reduce any nuisance odors from being perceived off-site. The goals established by the City regarding the odor control system were:No odors at the plant fencelineDesign odor control for the health and safety of the facility operatorsApply a proven odor control technologyProvide redundancy to preclude odor control system down-timeThe odor control challenges were characterizing the sewer and new headworks odor potentials and selecting the most cost-viable technology to comply with these goals.Odor assessment investigations were conducted to characterize odor conditions in the collection system and at the pre-existing headworks area of the WWTP. As a result of the collection system being redesigned to handle and store wet weather flows, it was anticipated the potential for hydrogen sulfide generation and release, due to this greater detention time and deposition of solids, would be increased. Site measurements showed a range of hydrogen sulfideconcentrations from 1 to 160-ppmv. Field measurements and office calculations were used to establish the overall odor control system design average and peak concentrations of hydrogen sulfide as 3.5 and 33-ppmv, respectively. Other reduced sulfur compounds were present, but at considerably lower levels. The volume of air required, to provide effective capture and containment of the odors, was approximately 100,000 cfm.Four odor control technologies were evaluated (wet scrubbing, carbon adsorption, biofiltration, and biotrickling filter) and biotrickling filters were selected based on:lower operating costsno chemicals used/stored/handledno hazardous residualsgreener, sustainable operationless maintenance laboreffective treatment of design odor loadsOnce selected, the City of Columbus installed the largest stand-alone biotrickling filter system (provided by Bioway) for odor treatment in North America. The system was designed to treat 96,000 cfm of odorous air.The biotrickling odor control system consists of ten towers fed by a central fan system. The fan system pulls the odorous air through a carefully designed combination of main and branch ducts and pushes it through the ten towers. The treated air is exhausted through a stack at the top of each of the towers. The multiple towers were designed to manage the varying hydrogen sulfide concentrations and other reduced sulfur compounds associated with raw influent wastewater.Extensive process performance trials were conducted and the biotrickling filter system was found to have exceeded its design performance requirements. The system demonstrated 96% removal of odors, taking the average exhaust odor concentration to less than 300 odor units. The odor control system has proved to be robust and has coped well with the varying seasonal odor loads experienced in central Ohio over the past nearly two years of operation (the new headworks building with odor control system was placed into operation in March 2008).This paper will present the odor control technologies that were evaluated, review the biotrickling filter system and present performance data.
To reduce overflows of untreated wastewater into area waterways, the City of Columbus constructed a large capacity sewer (13-foot diameter) to provide up to 60 million gallons of storage (equivalent to the projected wet weather flow from a 1-year storm event) and connected it to a new headworks facility at the Southerly Wastewater Treatment Plant that was designed to pump and treat over 400-mgd....
Author(s)
Chester M. MortonRichard J. PopeRichard A. ReinholdBart KraakmanSteve MessChad Dunn
SourceProceedings of the Water Environment Federation
SubjectArticles
Document typeConference Paper
PublisherWater Environment Federation
Print publication date Jan, 2010
ISSN1938-6478
SICI1938-6478(20100101)2010:3L.671;1-
DOI10.2175/193864710802768046
Volume / Issue2010 / 3
Content sourceOdors and Air Pollutants Conference
First / last page(s)671 - 690
Copyright2010
Word count556
Subject keywordsHeadworksbio-trickling filterhydrogen sulfideodor concentrationdilution-to-threshold

Actions, changes & tasks

Outstanding Actions

Add action for paragraph

Current Changes

Add signficant change

Current Tasks

Add risk task

Connect with us

Follow us on Facebook
Follow us on Twitter
Connect to us on LinkedIn
Subscribe on YouTube
Powered by Librios Ltd
Powered by Librios Ltd
Authors
Terms of Use
Policies
Help
Accessibility
Contact us
Copyright © 2024 by the Water Environment Federation
Loading items
There are no items to display at the moment.
Something went wrong trying to load these items.
Description: WWTF Digital Boot 180x150
WWTF Digital (180x150)
Created on Jul 02
Websitehttps:/­/­www.wef.org/­wwtf?utm_medium=WWTF&utm_source=AccessWater&utm_campaign=WWTF
180x150
Chester M. Morton# Richard J. Pope# Richard A. Reinhold# Bart Kraakman# Steve Mess# Chad Dunn. Columbus Discovers a Greener Odor Control Approach. Alexandria, VA 22314-1994, USA: Water Environment Federation, 2018. Web. 2 Jul. 2025. <https://www.accesswater.org?id=-297788CITANCHOR>.
Chester M. Morton# Richard J. Pope# Richard A. Reinhold# Bart Kraakman# Steve Mess# Chad Dunn. Columbus Discovers a Greener Odor Control Approach. Alexandria, VA 22314-1994, USA: Water Environment Federation, 2018. Accessed July 2, 2025. https://www.accesswater.org/?id=-297788CITANCHOR.
Chester M. Morton# Richard J. Pope# Richard A. Reinhold# Bart Kraakman# Steve Mess# Chad Dunn
Columbus Discovers a Greener Odor Control Approach
Access Water
Water Environment Federation
December 22, 2018
July 2, 2025
https://www.accesswater.org/?id=-297788CITANCHOR