A Change in Filter Control Almost Doubles Filtered Water Production per Filter Run
  • Browse
  • Compilations
    • Compilations list
  • Subscriptions
Tools

Related contents

Loading related content

Workflow

No linked records yet

X
  • Current: 2020-01-31 18:47:45 Administrator
  • 2020-01-31 18:47:44 Administrator
Description: Access Water
  • Browse
  • Compilations
  • Subscriptions
Log in
0
Accessibility Options

Base text size -

This is a sample piece of body text
Larger
Smaller
  • Shopping basket (0)
  • Accessibility options
  • Return to previous
Description: Book cover
A Change in Filter Control Almost Doubles Filtered Water Production per Filter Run

A Change in Filter Control Almost Doubles Filtered Water Production per Filter Run

A Change in Filter Control Almost Doubles Filtered Water Production per Filter Run

  • New
  • View
  • Details
  • Reader
  • Default
  • Share
  • Email
  • Facebook
  • Twitter
  • LinkedIn
  • New
  • View
  • Default view
  • Reader view
  • Data view
  • Details

This page cannot be printed from here

Please use the dedicated print option from the 'view' drop down menu located in the blue ribbon in the top, right section of the publication.

screenshot of print menu option

Description: Book cover
A Change in Filter Control Almost Doubles Filtered Water Production per Filter Run
Abstract
Comparison of variable flow rate operation vs. traditional constant rate was performed at the A battery filters over two time periods (from September to November 2010) and (from January to March 2011). Results show that operation at variable flow rate increased volume of the filtrate per filter run on average by about 70% during first testing period and by about 75% during the second testing period. Filtered effluent quality under variable flow rate operation was very good and remained less than 2NTU at all times. It was on average about 0.57NTU which is significantly less than Title 22 requirement. Volume of backwash water per backwash has not been increased for the variable flow rate operation. Based on these results it can be concluded that implementation of variable flow rate operation may lead to an increased capacity of filters discharging to the Bay by 60%–70%, reduction of energy and chemical usage for backwash by 41%–43%.
Comparison of variable flow rate operation vs. traditional constant rate was performed at the A battery filters over two time periods (from September to November 2010) and (from January to March 2011). Results show that operation at variable flow rate increased volume of the filtrate per filter run on average by about 70% during first testing period and by about 75% during the second testing...
Author(s)
Rong LiuAlex Ekster
SourceProceedings of the Water Environment Federation
SubjectSession 12: Cost Saving Success Stories for WWTPs
Document typeConference Paper
PublisherWater Environment Federation
Print publication date Jan, 2011
ISSN1938-6478
SICI1938-6478(20110101)2011:17L.578;1-
DOI10.2175/193864711802639543
Volume / Issue2011 / 17
Content sourceWEFTEC
First / last page(s)578 - 596
Copyright2011
Word count169
Subject keywordsWastewater filtrationenergy savinghigh rate filtrationvariable rate filtration

Purchase price $11.50

Get access
Log in Purchase content Purchase subscription
You may already have access to this content if you have previously purchased this content or have a subscription.
Need to create an account?

You can purchase access to this content but you might want to consider a subscription for a wide variety of items at a substantial discount!

Purchase access to 'A Change in Filter Control Almost Doubles Filtered Water Production per Filter Run'

Add to cart
Purchase a subscription to gain access to 18,000+ Proceeding Papers, 25+ Fact Sheets, 20+ Technical Reports, 50+ magazine articles and select Technical Publications' chapters.
Loading items
There are no items to display at the moment.
Something went wrong trying to load these items.
Description: Book cover
A Change in Filter Control Almost Doubles Filtered Water Production per Filter Run
Pricing
Non-member price: $11.50
Member price:
-298634
Get access
-298634
Log in Purchase content Purchase subscription
You may already have access to this content if you have previously purchased this content or have a subscription.
Need to create an account?

You can purchase access to this content but you might want to consider a subscription for a wide variety of items at a substantial discount!

Purchase access to 'A Change in Filter Control Almost Doubles Filtered Water Production per Filter Run'

Add to cart
Purchase a subscription to gain access to 18,000+ Proceeding Papers, 25+ Fact Sheets, 20+ Technical Reports, 50+ magazine articles and select Technical Publications' chapters.

Details

Description: Book cover
A Change in Filter Control Almost Doubles Filtered Water Production per Filter Run
Abstract
Comparison of variable flow rate operation vs. traditional constant rate was performed at the A battery filters over two time periods (from September to November 2010) and (from January to March 2011). Results show that operation at variable flow rate increased volume of the filtrate per filter run on average by about 70% during first testing period and by about 75% during the second testing period. Filtered effluent quality under variable flow rate operation was very good and remained less than 2NTU at all times. It was on average about 0.57NTU which is significantly less than Title 22 requirement. Volume of backwash water per backwash has not been increased for the variable flow rate operation. Based on these results it can be concluded that implementation of variable flow rate operation may lead to an increased capacity of filters discharging to the Bay by 60%–70%, reduction of energy and chemical usage for backwash by 41%–43%.
Comparison of variable flow rate operation vs. traditional constant rate was performed at the A battery filters over two time periods (from September to November 2010) and (from January to March 2011). Results show that operation at variable flow rate increased volume of the filtrate per filter run on average by about 70% during first testing period and by about 75% during the second testing...
Author(s)
Rong LiuAlex Ekster
SourceProceedings of the Water Environment Federation
SubjectSession 12: Cost Saving Success Stories for WWTPs
Document typeConference Paper
PublisherWater Environment Federation
Print publication date Jan, 2011
ISSN1938-6478
SICI1938-6478(20110101)2011:17L.578;1-
DOI10.2175/193864711802639543
Volume / Issue2011 / 17
Content sourceWEFTEC
First / last page(s)578 - 596
Copyright2011
Word count169
Subject keywordsWastewater filtrationenergy savinghigh rate filtrationvariable rate filtration

Actions, changes & tasks

Outstanding Actions

Add action for paragraph

Current Changes

Add signficant change

Current Tasks

Add risk task

Connect with us

Follow us on Facebook
Follow us on Twitter
Connect to us on LinkedIn
Subscribe on YouTube
Powered by Librios Ltd
Powered by Librios Ltd
Authors
Terms of Use
Policies
Help
Accessibility
Contact us
Copyright © 2024 by the Water Environment Federation
Loading items
There are no items to display at the moment.
Something went wrong trying to load these items.
Description: WWTF Digital Boot 180x150
WWTF Digital (180x150)
Created on Jul 02
Websitehttps:/­/­www.wef.org/­wwtf?utm_medium=WWTF&utm_source=AccessWater&utm_campaign=WWTF
180x150
Rong Liu# Alex Ekster. A Change in Filter Control Almost Doubles Filtered Water Production per Filter Run. Alexandria, VA 22314-1994, USA: Water Environment Federation, 2018. Web. 6 Jun. 2025. <https://www.accesswater.org?id=-298634CITANCHOR>.
Rong Liu# Alex Ekster. A Change in Filter Control Almost Doubles Filtered Water Production per Filter Run. Alexandria, VA 22314-1994, USA: Water Environment Federation, 2018. Accessed June 6, 2025. https://www.accesswater.org/?id=-298634CITANCHOR.
Rong Liu# Alex Ekster
A Change in Filter Control Almost Doubles Filtered Water Production per Filter Run
Access Water
Water Environment Federation
December 22, 2018
June 6, 2025
https://www.accesswater.org/?id=-298634CITANCHOR