lastID = -298920
Skip to main content Skip to top navigation Skip to site search
Top of page
  • My citations options
    Web Back (from Web)
    Chicago Back (from Chicago)
    MLA Back (from MLA)
Close action menu

You need to login to use this feature.

Please wait a moment…
Please wait while we update your results...
Please wait a moment...
Description: Access Water
Context Menu
Description: Book cover
Refurbishment of an Aging Fluid Bed Biosolids Incinerator and Development of a 10 year Capital Plan: An Alternative to Replacement
  • Browse
  • Compilations
    • Compilations list
  • Subscriptions
Tools

Related contents

Loading related content

Workflow

No linked records yet

X
  • Current: 2022-05-04 16:36:29 Adam Phillips
  • 2022-05-04 16:36:28 Adam Phillips
  • 2020-03-27 00:15:36 Adam Phillips
  • 2020-02-01 03:40:01 Administrator
  • 2020-02-01 03:40:00 Administrator
Description: Access Water
  • Browse
  • Compilations
  • Subscriptions
Log in
0
Accessibility Options

Base text size -

This is a sample piece of body text
Larger
Smaller
  • Shopping basket (0)
  • Accessibility options
  • Return to previous
Description: Book cover
Refurbishment of an Aging Fluid Bed Biosolids Incinerator and Development of a 10 year Capital Plan: An Alternative to Replacement

Refurbishment of an Aging Fluid Bed Biosolids Incinerator and Development of a 10 year Capital Plan: An Alternative to Replacement

Refurbishment of an Aging Fluid Bed Biosolids Incinerator and Development of a 10 year Capital Plan: An Alternative to Replacement

  • New
  • View
  • Details
  • Reader
  • Default
  • Share
  • Email
  • Facebook
  • Twitter
  • LinkedIn
  • New
  • View
  • Default view
  • Reader view
  • Data view
  • Details

This page cannot be printed from here

Please use the dedicated print option from the 'view' drop down menu located in the blue ribbon in the top, right section of the publication.

screenshot of print menu option

Description: Book cover
Refurbishment of an Aging Fluid Bed Biosolids Incinerator and Development of a 10 year Capital Plan: An Alternative to Replacement
Abstract
The City of London, Ontario operates a 60 dry tonne/day hot wind box fluid bed incinerator (FBI) at the Greenway Pollution Control Centre (PCC) to dispose of the biosolids generated at all of its municipal sewage treatment plants. The incinerator was commissioned in 1988 and had been in continuous duty since, with the exception of annual maintenance shutdowns. Currently the incinerator runs 6 or 7 days per week, 24 hours per day.In 2007, meetings and site inspections were completed at the request of the City to investigate potential repairs to their FBI. Numerous areas on the upper freeboard of the FBI were severely degraded and had been extensively previously patched. Historic non–destructive testing results indicated that in localized areas less than 50% of the original steel casing thickness remained on the incinerator freeboard. Based on the age of the facility (20 years of operation), preliminary analysis of the information available, and our experience at other similar installations, AECOM identified the likely need for much more extensive repairs than originally anticipated by City staff.A detailed incinerator assessment was completed in 2007 which involved identifying the system components, reviewing and recording the past repair history, identifying critical process equipment, evaluating the current condition of process equipment using various non-destructive testing techniques, estimating the remaining life, estimating the repair costs of the critical process equipment, and generating a capital timeline and cash flow.The Report evaluated a number of scenarios ranging from simple repair to refurbishment to replacement with a new incinerator and considered capital cost as well as operating impacts (downtime). An implementation plan consisting of staged repairs, including an initial 4.6 million refurbishment and a total 10 year capital repair cost anticipated to be 13.4 million was recommended. This compares to 32+ for a new incinerator (depending on ancillaries) and interim repairs to the existing unit during procurement and construction.Based on the recommended scope of work, a construction methodology was developed and a construction contract was tendered. Included in the scope of the project was detailed design of new incinerator refractory, new incinerator upper sidewalls and roof steel, new incinerator refractory lined outlet ductwork, new air to air pre-heater, new flue gas re-heater, and modified venturi scrubber.Work on the 4.6M project occurred from 2007 to 2009. Given the high cost of disposing of sludge during the downtime a major consideration was limiting the downtime to the extent possible. An innovative construction incentive approach, consisting of penalties and bonuses was used to obtain the optimum balance between capital cost and downtime operating costs. The innovative approach resulted in the project being completed ahead of time and below budget.
The City of London, Ontario operates a 60 dry tonne/day hot wind box fluid bed incinerator (FBI) at the Greenway Pollution Control Centre (PCC) to dispose of the biosolids generated at all of its municipal sewage treatment plants. The incinerator was commissioned in 1988 and had been in continuous duty since, with the exception of annual maintenance shutdowns. Currently the incinerator runs 6 or 7...
Author(s)
Derek HatanakaJohn Fitzgerald
SourceProceedings of the Water Environment Federation
SubjectSession 12: Thermal Processes - Incineration
Document typeConference Paper
PublisherWater Environment Federation
Print publication date Jan, 2011
ISSN1938-6478
SICI1938-6478(20110101)2011:4L.838;1-
DOI10.2175/193864711802862563
Volume / Issue2011 / 4
Content sourceResiduals and Biosolids Conference
First / last page(s)838 - 866
Copyright2011
Word count457
Subject keywordsFluidized Bed IncineratorFBI RefurbishmentBiosolids Thermal Treatmentretrofit

Purchase price $11.50

Get access
Log in Purchase content Purchase subscription
You may already have access to this content if you have previously purchased this content or have a subscription.
Need to create an account?

You can purchase access to this content but you might want to consider a subscription for a wide variety of items at a substantial discount!

Purchase access to 'Refurbishment of an Aging Fluid Bed Biosolids Incinerator and Development of a 10 year Capital Plan: An Alternative to Replacement'

Add to cart
Purchase a subscription to gain access to 18,000+ Proceeding Papers, 25+ Fact Sheets, 20+ Technical Reports, 50+ magazine articles and select Technical Publications' chapters.
Loading items
There are no items to display at the moment.
Something went wrong trying to load these items.
Description: Book cover
Refurbishment of an Aging Fluid Bed Biosolids Incinerator and Development of a 10 year Capital Plan: An Alternative to Replacement
Pricing
Non-member price: $11.50
Member price:
-298920
Get access
-298920
Log in Purchase content Purchase subscription
You may already have access to this content if you have previously purchased this content or have a subscription.
Need to create an account?

You can purchase access to this content but you might want to consider a subscription for a wide variety of items at a substantial discount!

Purchase access to 'Refurbishment of an Aging Fluid Bed Biosolids Incinerator and Development of a 10 year Capital Plan: An Alternative to Replacement'

Add to cart
Purchase a subscription to gain access to 18,000+ Proceeding Papers, 25+ Fact Sheets, 20+ Technical Reports, 50+ magazine articles and select Technical Publications' chapters.

Details

Description: Book cover
Refurbishment of an Aging Fluid Bed Biosolids Incinerator and Development of a 10 year Capital Plan: An Alternative to Replacement
Abstract
The City of London, Ontario operates a 60 dry tonne/day hot wind box fluid bed incinerator (FBI) at the Greenway Pollution Control Centre (PCC) to dispose of the biosolids generated at all of its municipal sewage treatment plants. The incinerator was commissioned in 1988 and had been in continuous duty since, with the exception of annual maintenance shutdowns. Currently the incinerator runs 6 or 7 days per week, 24 hours per day.In 2007, meetings and site inspections were completed at the request of the City to investigate potential repairs to their FBI. Numerous areas on the upper freeboard of the FBI were severely degraded and had been extensively previously patched. Historic non–destructive testing results indicated that in localized areas less than 50% of the original steel casing thickness remained on the incinerator freeboard. Based on the age of the facility (20 years of operation), preliminary analysis of the information available, and our experience at other similar installations, AECOM identified the likely need for much more extensive repairs than originally anticipated by City staff.A detailed incinerator assessment was completed in 2007 which involved identifying the system components, reviewing and recording the past repair history, identifying critical process equipment, evaluating the current condition of process equipment using various non-destructive testing techniques, estimating the remaining life, estimating the repair costs of the critical process equipment, and generating a capital timeline and cash flow.The Report evaluated a number of scenarios ranging from simple repair to refurbishment to replacement with a new incinerator and considered capital cost as well as operating impacts (downtime). An implementation plan consisting of staged repairs, including an initial 4.6 million refurbishment and a total 10 year capital repair cost anticipated to be 13.4 million was recommended. This compares to 32+ for a new incinerator (depending on ancillaries) and interim repairs to the existing unit during procurement and construction.Based on the recommended scope of work, a construction methodology was developed and a construction contract was tendered. Included in the scope of the project was detailed design of new incinerator refractory, new incinerator upper sidewalls and roof steel, new incinerator refractory lined outlet ductwork, new air to air pre-heater, new flue gas re-heater, and modified venturi scrubber.Work on the 4.6M project occurred from 2007 to 2009. Given the high cost of disposing of sludge during the downtime a major consideration was limiting the downtime to the extent possible. An innovative construction incentive approach, consisting of penalties and bonuses was used to obtain the optimum balance between capital cost and downtime operating costs. The innovative approach resulted in the project being completed ahead of time and below budget.
The City of London, Ontario operates a 60 dry tonne/day hot wind box fluid bed incinerator (FBI) at the Greenway Pollution Control Centre (PCC) to dispose of the biosolids generated at all of its municipal sewage treatment plants. The incinerator was commissioned in 1988 and had been in continuous duty since, with the exception of annual maintenance shutdowns. Currently the incinerator runs 6 or 7...
Author(s)
Derek HatanakaJohn Fitzgerald
SourceProceedings of the Water Environment Federation
SubjectSession 12: Thermal Processes - Incineration
Document typeConference Paper
PublisherWater Environment Federation
Print publication date Jan, 2011
ISSN1938-6478
SICI1938-6478(20110101)2011:4L.838;1-
DOI10.2175/193864711802862563
Volume / Issue2011 / 4
Content sourceResiduals and Biosolids Conference
First / last page(s)838 - 866
Copyright2011
Word count457
Subject keywordsFluidized Bed IncineratorFBI RefurbishmentBiosolids Thermal Treatmentretrofit

Actions, changes & tasks

Outstanding Actions

Add action for paragraph

Current Changes

Add signficant change

Current Tasks

Add risk task

Connect with us

Follow us on Facebook
Follow us on Twitter
Connect to us on LinkedIn
Subscribe on YouTube
Powered by Librios Ltd
Powered by Librios Ltd
Authors
Terms of Use
Policies
Help
Accessibility
Contact us
Copyright © 2024 by the Water Environment Federation
Loading items
There are no items to display at the moment.
Something went wrong trying to load these items.
Description: WWTF Digital Boot 180x150
WWTF Digital (180x150)
Created on Jul 02
Websitehttps:/­/­www.wef.org/­wwtf?utm_medium=WWTF&utm_source=AccessWater&utm_campaign=WWTF
180x150
Derek Hatanaka# John Fitzgerald. Refurbishment of an Aging Fluid Bed Biosolids Incinerator and Development of a 10 year Capital Plan: An Alternative to Replacement. Alexandria, VA 22314-1994, USA: Water Environment Federation, 2018. Web. 10 Jun. 2025. <https://www.accesswater.org?id=-298920CITANCHOR>.
Derek Hatanaka# John Fitzgerald. Refurbishment of an Aging Fluid Bed Biosolids Incinerator and Development of a 10 year Capital Plan: An Alternative to Replacement. Alexandria, VA 22314-1994, USA: Water Environment Federation, 2018. Accessed June 10, 2025. https://www.accesswater.org/?id=-298920CITANCHOR.
Derek Hatanaka# John Fitzgerald
Refurbishment of an Aging Fluid Bed Biosolids Incinerator and Development of a 10 year Capital Plan: An Alternative to Replacement
Access Water
Water Environment Federation
December 22, 2018
June 10, 2025
https://www.accesswater.org/?id=-298920CITANCHOR