lastID = -298960
Skip to main content Skip to top navigation Skip to site search
Top of page
  • My citations options
    Web Back (from Web)
    Chicago Back (from Chicago)
    MLA Back (from MLA)
Close action menu

You need to login to use this feature.

Please wait a moment…
Please wait while we update your results...
Please wait a moment...
Description: Access Water
Context Menu
Description: Book cover
Field Demonstration of Electro-Scan Defect Location Technology for Condition Assessment of Wastewater Collection Systems
  • Browse
  • Compilations
    • Compilations list
  • Subscriptions
Tools

Related contents

Loading related content

Workflow

No linked records yet

X
  • Current: 2022-05-04 21:24:18 Adam Phillips
  • 2022-05-04 21:24:17 Adam Phillips
  • 2020-03-26 22:05:48 Adam Phillips
  • 2020-01-31 23:06:02 Administrator
  • 2020-01-31 23:06:01 Administrator
Description: Access Water
  • Browse
  • Compilations
  • Subscriptions
Log in
0
Accessibility Options

Base text size -

This is a sample piece of body text
Larger
Smaller
  • Shopping basket (0)
  • Accessibility options
  • Return to previous
Description: Book cover
Field Demonstration of Electro-Scan Defect Location Technology for Condition Assessment of Wastewater Collection Systems

Field Demonstration of Electro-Scan Defect Location Technology for Condition Assessment of Wastewater Collection Systems

Field Demonstration of Electro-Scan Defect Location Technology for Condition Assessment of Wastewater Collection Systems

  • New
  • View
  • Details
  • Reader
  • Default
  • Share
  • Email
  • Facebook
  • Twitter
  • LinkedIn
  • New
  • View
  • Default view
  • Reader view
  • Data view
  • Details

This page cannot be printed from here

Please use the dedicated print option from the 'view' drop down menu located in the blue ribbon in the top, right section of the publication.

screenshot of print menu option

Description: Book cover
Field Demonstration of Electro-Scan Defect Location Technology for Condition Assessment of Wastewater Collection Systems
Abstract
A USEPA-sponsored field demonstration program was conducted to gather technically reliable cost and performance information on the electro-scan (FELL-41) pipeline condition assessment technology. Electro-scan technology can be used to estimate the magnitude and location of potential leaks along a pipeline, helping utilities better understand and control sources of infiltration/exfiltration. It directly measures leak potential, independent of external conditions that are temporal in nature (e.g., seasonal, wet weather). Its use of direct measurements provides a quantitative analysis of leak potential without relying on visual observation.The field demonstration was conducted in Kansas City, MO in August 2010 in areas of the collection system with known operational issues due to root intrusion and inflow/infiltration (I/I). The project was part of a USEPA research program “Innovation and Research for Water Infrastructure for the 21st Century.” The program was implemented by the USEPA Office of Research and Development to generate science and engineering knowledge to help utilities reduce the cost and improve the effectiveness of operation, maintenance, and replacement of aging drinking water and wastewater treatment and conveyance systems.This paper provides an overview of field demonstration results for the electro-scan (FELL-41) technology and compares them to observations obtained using traditional in-line closed-circuit television (CCTV) inspection. Electro-scan technology uses the variation of electric current flow through the pipe wall to identify pipe defects that are potential leaks. The standard practice is fully described in the ASTM standard F2550-06. It can be used in non-conductive (i.e., non-ferrous) gravity sanitary and combined sewer mains, and service laterals. The field demonstration was carried out in an area with small diameter (8-in. and 10-in.) vitrified clay pipe. Electro-scanning was performed under fully surcharged conditions, which was accomplished by using a sliding pipe plug in conjunction with a jet truck. Technology performance was measured in terms of versatility, accuracy, repeatability, and inspection time/production rate. Results were compared to a baseline condition assessment completed using traditional in-line CCTV inspection. The evaluation of the total cost included factors such as planning, mobilization, field inspection, and reporting.Electro-scanning identified an average of 17 defects per pipe segment, although most were determined to be small defects (defined as anomalies with an amplitude of 1 to 4). It identified more leakage-related defects than CCTV and in some cases, detected different defects than CCTV. Electro-scanning technology did not detect all line breaks identified by CCTV, some of which may be stressed areas that may progress toward leakage. Electro-scanning can provide information on leak potential that is complementary to CCTV observations. While CCTV provided visual identification of pipe features, electro-scanning results were used to interpret defect severity and to better understand whether a defect poses a serious infiltration or exfiltration problem.
A USEPA-sponsored field demonstration program was conducted to gather technically reliable cost and performance information on the electro-scan (FELL-41) pipeline condition assessment technology. Electro-scan technology can be used to estimate the magnitude and location of potential leaks along a pipeline, helping utilities better understand and control sources of infiltration/exfiltration. It...
Author(s)
Mary Ellen TuccilloCharles WilmutChristopher FeeneyKathy MartelAriamalar Selvakumar
SourceProceedings of the Water Environment Federation
SubjectSession 3: EPA Research
Document typeConference Paper
PublisherWater Environment Federation
Print publication date Jan, 2011
ISSN1938-6478
SICI1938-6478(20110101)2011:5L.265;1-
DOI10.2175/193864711802837309
Volume / Issue2011 / 5
Content sourceCollection Systems Conference
First / last page(s)265 - 281
Copyright2011
Word count457
Subject keywordsCondition assessmentasset managementinspectionsewer rehabilitationdemonstration

Purchase price $11.50

Get access
Log in Purchase content Purchase subscription
You may already have access to this content if you have previously purchased this content or have a subscription.
Need to create an account?

You can purchase access to this content but you might want to consider a subscription for a wide variety of items at a substantial discount!

Purchase access to 'Field Demonstration of Electro-Scan Defect Location Technology for Condition Assessment of Wastewater Collection Systems'

Add to cart
Purchase a subscription to gain access to 18,000+ Proceeding Papers, 25+ Fact Sheets, 20+ Technical Reports, 50+ magazine articles and select Technical Publications' chapters.
Loading items
There are no items to display at the moment.
Something went wrong trying to load these items.
Description: Book cover
Field Demonstration of Electro-Scan Defect Location Technology for Condition Assessment of Wastewater Collection Systems
Pricing
Non-member price: $11.50
Member price:
-298960
Get access
-298960
Log in Purchase content Purchase subscription
You may already have access to this content if you have previously purchased this content or have a subscription.
Need to create an account?

You can purchase access to this content but you might want to consider a subscription for a wide variety of items at a substantial discount!

Purchase access to 'Field Demonstration of Electro-Scan Defect Location Technology for Condition Assessment of Wastewater Collection Systems'

Add to cart
Purchase a subscription to gain access to 18,000+ Proceeding Papers, 25+ Fact Sheets, 20+ Technical Reports, 50+ magazine articles and select Technical Publications' chapters.

Details

Description: Book cover
Field Demonstration of Electro-Scan Defect Location Technology for Condition Assessment of Wastewater Collection Systems
Abstract
A USEPA-sponsored field demonstration program was conducted to gather technically reliable cost and performance information on the electro-scan (FELL-41) pipeline condition assessment technology. Electro-scan technology can be used to estimate the magnitude and location of potential leaks along a pipeline, helping utilities better understand and control sources of infiltration/exfiltration. It directly measures leak potential, independent of external conditions that are temporal in nature (e.g., seasonal, wet weather). Its use of direct measurements provides a quantitative analysis of leak potential without relying on visual observation.The field demonstration was conducted in Kansas City, MO in August 2010 in areas of the collection system with known operational issues due to root intrusion and inflow/infiltration (I/I). The project was part of a USEPA research program “Innovation and Research for Water Infrastructure for the 21st Century.” The program was implemented by the USEPA Office of Research and Development to generate science and engineering knowledge to help utilities reduce the cost and improve the effectiveness of operation, maintenance, and replacement of aging drinking water and wastewater treatment and conveyance systems.This paper provides an overview of field demonstration results for the electro-scan (FELL-41) technology and compares them to observations obtained using traditional in-line closed-circuit television (CCTV) inspection. Electro-scan technology uses the variation of electric current flow through the pipe wall to identify pipe defects that are potential leaks. The standard practice is fully described in the ASTM standard F2550-06. It can be used in non-conductive (i.e., non-ferrous) gravity sanitary and combined sewer mains, and service laterals. The field demonstration was carried out in an area with small diameter (8-in. and 10-in.) vitrified clay pipe. Electro-scanning was performed under fully surcharged conditions, which was accomplished by using a sliding pipe plug in conjunction with a jet truck. Technology performance was measured in terms of versatility, accuracy, repeatability, and inspection time/production rate. Results were compared to a baseline condition assessment completed using traditional in-line CCTV inspection. The evaluation of the total cost included factors such as planning, mobilization, field inspection, and reporting.Electro-scanning identified an average of 17 defects per pipe segment, although most were determined to be small defects (defined as anomalies with an amplitude of 1 to 4). It identified more leakage-related defects than CCTV and in some cases, detected different defects than CCTV. Electro-scanning technology did not detect all line breaks identified by CCTV, some of which may be stressed areas that may progress toward leakage. Electro-scanning can provide information on leak potential that is complementary to CCTV observations. While CCTV provided visual identification of pipe features, electro-scanning results were used to interpret defect severity and to better understand whether a defect poses a serious infiltration or exfiltration problem.
A USEPA-sponsored field demonstration program was conducted to gather technically reliable cost and performance information on the electro-scan (FELL-41) pipeline condition assessment technology. Electro-scan technology can be used to estimate the magnitude and location of potential leaks along a pipeline, helping utilities better understand and control sources of infiltration/exfiltration. It...
Author(s)
Mary Ellen TuccilloCharles WilmutChristopher FeeneyKathy MartelAriamalar Selvakumar
SourceProceedings of the Water Environment Federation
SubjectSession 3: EPA Research
Document typeConference Paper
PublisherWater Environment Federation
Print publication date Jan, 2011
ISSN1938-6478
SICI1938-6478(20110101)2011:5L.265;1-
DOI10.2175/193864711802837309
Volume / Issue2011 / 5
Content sourceCollection Systems Conference
First / last page(s)265 - 281
Copyright2011
Word count457
Subject keywordsCondition assessmentasset managementinspectionsewer rehabilitationdemonstration

Actions, changes & tasks

Outstanding Actions

Add action for paragraph

Current Changes

Add signficant change

Current Tasks

Add risk task

Connect with us

Follow us on Facebook
Follow us on Twitter
Connect to us on LinkedIn
Subscribe on YouTube
Powered by Librios Ltd
Powered by Librios Ltd
Authors
Terms of Use
Policies
Help
Accessibility
Contact us
Copyright © 2024 by the Water Environment Federation
Loading items
There are no items to display at the moment.
Something went wrong trying to load these items.
Description: WWTF Digital Boot 180x150
WWTF Digital (180x150)
Created on Jul 02
Websitehttps:/­/­www.wef.org/­wwtf?utm_medium=WWTF&utm_source=AccessWater&utm_campaign=WWTF
180x150
Mary Ellen Tuccillo# Charles Wilmut# Christopher Feeney# Kathy Martel# Ariamalar Selvakumar. Field Demonstration of Electro-Scan Defect Location Technology for Condition Assessment of Wastewater Collection Systems. Alexandria, VA 22314-1994, USA: Water Environment Federation, 2018. Web. 6 Jun. 2025. <https://www.accesswater.org?id=-298960CITANCHOR>.
Mary Ellen Tuccillo# Charles Wilmut# Christopher Feeney# Kathy Martel# Ariamalar Selvakumar. Field Demonstration of Electro-Scan Defect Location Technology for Condition Assessment of Wastewater Collection Systems. Alexandria, VA 22314-1994, USA: Water Environment Federation, 2018. Accessed June 6, 2025. https://www.accesswater.org/?id=-298960CITANCHOR.
Mary Ellen Tuccillo# Charles Wilmut# Christopher Feeney# Kathy Martel# Ariamalar Selvakumar
Field Demonstration of Electro-Scan Defect Location Technology for Condition Assessment of Wastewater Collection Systems
Access Water
Water Environment Federation
December 22, 2018
June 6, 2025
https://www.accesswater.org/?id=-298960CITANCHOR