lastID = -10102360
Skip to main content Skip to top navigation Skip to site search
Top of page
  • My citations options
    Web Back (from Web)
    Chicago Back (from Chicago)
    MLA Back (from MLA)
Close action menu

You need to login to use this feature.

Please wait a moment…
Please wait while we update your results...
Please wait a moment...
Description: Access Water
Context Menu
Description: How to use condition assessment data to improve force main and lift station design...
How to use condition assessment data to improve force main and lift station design and operation
  • Browse
  • Compilations
    • Compilations list
  • Subscriptions
Tools

Related contents

Loading related content

Workflow

No linked records yet

X
  • Current: 2024-04-09 07:27:13 Adam Phillips
  • 2024-04-08 22:01:18 Adam Phillips Release
  • 2024-04-08 21:38:53 Adam Phillips
  • 2024-04-08 21:08:02 Adam Phillips
  • 2024-04-08 20:49:54 Adam Phillips
  • 2024-04-08 16:40:57 Adam Phillips
  • 2024-04-08 15:32:09 Adam Phillips
  • 2024-04-08 14:42:42 Adam Phillips
Description: Access Water
  • Browse
  • Compilations
  • Subscriptions
Log in
0
Accessibility Options

Base text size -

This is a sample piece of body text
Larger
Smaller
  • Shopping basket (0)
  • Accessibility options
  • Return to previous
Description: How to use condition assessment data to improve force main and lift station design...
How to use condition assessment data to improve force main and lift station design and operation

How to use condition assessment data to improve force main and lift station design and operation

How to use condition assessment data to improve force main and lift station design and operation

  • New
  • View
  • Details
  • Reader
  • Default
  • Share
  • Email
  • Facebook
  • Twitter
  • LinkedIn
  • New
  • View
  • Default view
  • Reader view
  • Data view
  • Details

This page cannot be printed from here

Please use the dedicated print option from the 'view' drop down menu located in the blue ribbon in the top, right section of the publication.

screenshot of print menu option

Description: How to use condition assessment data to improve force main and lift station design...
How to use condition assessment data to improve force main and lift station design and operation
Abstract
Purpose: Lift stations and force mains are essential to any wastewater collection system. Lift stations and associated force mains operate in a highly corrosive environment, typically subjected to widely fluctuating flows and pressure surges that affect force main integrity. Lift station and force main design seeks to avoid common damage modes, including H2S-induced corrosion and solids accumulation, but rarely benefits from the physical assessment of the installed and operating system to evaluate design robustness. The current study outlines the design and operational enhancements of lift stations and force mains as identified during the condition assessment of Lift Station 43 (LS 43) in the City of Phoenix (City). The City owns and operates 28 lift stations and approximately 72 miles of force mains, including approximately 62 miles of 12-inch and larger force mains. A comprehensive condition assessment of the LS 43 force main was performed as part of the city's ongoing efforts to understand and minimize the risk associated with buried infrastructure. The LS 43 force main conveys wastewater approximately 1.5 miles from LS 43 on 75th Avenue south of Southern Avenue along 75th Avenue to Broadway. The force main has three barrels constructed of 24-inch diameter ductile iron pipe referred to as Barrels 1, 2, and 3 and experienced two breaks associated with air accumulation. A comprehensive assessment was completed, including hydraulic modeling, CCTV, and electromagnetic (EM) inspection. The study's results can be adopted to improve the service life of not just LS 43 but any future lift station and force main. Benefits: The LS 43 assessment identified best practices to improve lift station and force main hydraulics and service life. By utilizing hydraulic modeling with different pump states, the assessment identified the areas of negative pressure and gas buildup. The results of hydraulic modeling were confirmed via CCTV assessment, which showed the presence of a miscellaneous waterline in the force main. This revealed that incorrect ARV placement obstructed the efficient functioning of the lift station and force main. This presentation will benefit that industry by outlining the factors contributing to air accumulation and remedial measures to address the concern. The presentation will also discuss design modifications such as the location and elevation of air release valves (ARVs) and the type of ARVs the industry should adopt to improve the life of the force mains. Additionally, EM assessment determined internal corrosion below the springline caused by solids accumulation, an infrequently considered damage mode for ductile iron pipe in force main service. Suspended solids in wastewater can settle in the force main and develop areas of microbially induced concrete corrosion (MICC). Efforts to allow for maximum future capacity in the initial design had resulted in low velocities and solids accumulation. Cleaning tools are regularly employed to dislodge accumulated solids, but the lift station and force main designs rarely allow for easy launch and retrieval of a cleaning tool. Additionally, there is no clear guideline on the cleaning frequency to improve the system's service life and reduce operational costs. The study aims to discuss the velocities needed to prevent solid accumulation, as well as the frequency and essential design modifications necessary to support regular cleaning. The recommendations presented in this study can be applied universally to any lift station and help the industry develop designs with cleaning and maintenance requirements in mind. Status of Completion: The investigation work to address ongoing air accumulation and internal corrosion issues is 100% complete. Results indicated the flow velocities and cleaning methodologies the City should utilize to prevent further internal corrosion and location for ARVs installation to prevent air accumulation. The City is in the process of procuring a consultant to design the recommended improvements. Conclusion: The City will now be able to allocate necessary funds for regular force main cleaning, identify locations of concerns, conduct regular maintenance, improve lift station efficiency, and improve service life. In conclusion, the study has identified best practices to improve lift station and force main hydraulics and service life. These best practices can be used to improve future force main designs.
This paper was presented at the WEF Collection Systems and Stormwater Conference, April 9-12, 2024.
SpeakerCarpenetti, Edward
Presentation time
14:00:00
14:30:00
Session time
13:30:00
15:00:00
SessionPumping Operations
Session number06
Session locationConnecticut Convention Center, Hartford, Connecticut
TopicAsset Management, Bypass pumping, Collection Systems, Combined Sewer Overflow, Deep Sewer Tunnel, Flow control, Hydrogen Sulfide, Odor and Corrosion Control, Operations And Maintenance, Pump station, forcemain
TopicAsset Management, Bypass pumping, Collection Systems, Combined Sewer Overflow, Deep Sewer Tunnel, Flow control, Hydrogen Sulfide, Odor and Corrosion Control, Operations And Maintenance, Pump station, forcemain
Author(s)
Carpenetti, Edward
Author(s)E. Carpenetti1, S. Hada1, B. McDonald2
Author affiliation(s)Black & Veatch 1; HDR 2
SourceProceedings of the Water Environment Federation
Document typeConference Paper
PublisherWater Environment Federation
Print publication date Apr 2024
DOI10.2175/193864718825159355
Volume / Issue
Content sourceCollection Systems and Stormwater Conference
Copyright2024
Word count17

Purchase price $11.50

Get access
Log in Purchase content Purchase subscription
You may already have access to this content if you have previously purchased this content or have a subscription.
Need to create an account?

You can purchase access to this content but you might want to consider a subscription for a wide variety of items at a substantial discount!

Purchase access to 'How to use condition assessment data to improve force main and lift station design and operation'

Add to cart
Purchase a subscription to gain access to 18,000+ Proceeding Papers, 25+ Fact Sheets, 20+ Technical Reports, 50+ magazine articles and select Technical Publications' chapters.
Loading items
There are no items to display at the moment.
Something went wrong trying to load these items.
Description: How to use condition assessment data to improve force main and lift station design...
How to use condition assessment data to improve force main and lift station design and operation
Pricing
Non-member price: $11.50
Member price:
-10102360
Get access
-10102360
Log in Purchase content Purchase subscription
You may already have access to this content if you have previously purchased this content or have a subscription.
Need to create an account?

You can purchase access to this content but you might want to consider a subscription for a wide variety of items at a substantial discount!

Purchase access to 'How to use condition assessment data to improve force main and lift station design and operation'

Add to cart
Purchase a subscription to gain access to 18,000+ Proceeding Papers, 25+ Fact Sheets, 20+ Technical Reports, 50+ magazine articles and select Technical Publications' chapters.

Details

Description: How to use condition assessment data to improve force main and lift station design...
How to use condition assessment data to improve force main and lift station design and operation
Abstract
Purpose: Lift stations and force mains are essential to any wastewater collection system. Lift stations and associated force mains operate in a highly corrosive environment, typically subjected to widely fluctuating flows and pressure surges that affect force main integrity. Lift station and force main design seeks to avoid common damage modes, including H2S-induced corrosion and solids accumulation, but rarely benefits from the physical assessment of the installed and operating system to evaluate design robustness. The current study outlines the design and operational enhancements of lift stations and force mains as identified during the condition assessment of Lift Station 43 (LS 43) in the City of Phoenix (City). The City owns and operates 28 lift stations and approximately 72 miles of force mains, including approximately 62 miles of 12-inch and larger force mains. A comprehensive condition assessment of the LS 43 force main was performed as part of the city's ongoing efforts to understand and minimize the risk associated with buried infrastructure. The LS 43 force main conveys wastewater approximately 1.5 miles from LS 43 on 75th Avenue south of Southern Avenue along 75th Avenue to Broadway. The force main has three barrels constructed of 24-inch diameter ductile iron pipe referred to as Barrels 1, 2, and 3 and experienced two breaks associated with air accumulation. A comprehensive assessment was completed, including hydraulic modeling, CCTV, and electromagnetic (EM) inspection. The study's results can be adopted to improve the service life of not just LS 43 but any future lift station and force main. Benefits: The LS 43 assessment identified best practices to improve lift station and force main hydraulics and service life. By utilizing hydraulic modeling with different pump states, the assessment identified the areas of negative pressure and gas buildup. The results of hydraulic modeling were confirmed via CCTV assessment, which showed the presence of a miscellaneous waterline in the force main. This revealed that incorrect ARV placement obstructed the efficient functioning of the lift station and force main. This presentation will benefit that industry by outlining the factors contributing to air accumulation and remedial measures to address the concern. The presentation will also discuss design modifications such as the location and elevation of air release valves (ARVs) and the type of ARVs the industry should adopt to improve the life of the force mains. Additionally, EM assessment determined internal corrosion below the springline caused by solids accumulation, an infrequently considered damage mode for ductile iron pipe in force main service. Suspended solids in wastewater can settle in the force main and develop areas of microbially induced concrete corrosion (MICC). Efforts to allow for maximum future capacity in the initial design had resulted in low velocities and solids accumulation. Cleaning tools are regularly employed to dislodge accumulated solids, but the lift station and force main designs rarely allow for easy launch and retrieval of a cleaning tool. Additionally, there is no clear guideline on the cleaning frequency to improve the system's service life and reduce operational costs. The study aims to discuss the velocities needed to prevent solid accumulation, as well as the frequency and essential design modifications necessary to support regular cleaning. The recommendations presented in this study can be applied universally to any lift station and help the industry develop designs with cleaning and maintenance requirements in mind. Status of Completion: The investigation work to address ongoing air accumulation and internal corrosion issues is 100% complete. Results indicated the flow velocities and cleaning methodologies the City should utilize to prevent further internal corrosion and location for ARVs installation to prevent air accumulation. The City is in the process of procuring a consultant to design the recommended improvements. Conclusion: The City will now be able to allocate necessary funds for regular force main cleaning, identify locations of concerns, conduct regular maintenance, improve lift station efficiency, and improve service life. In conclusion, the study has identified best practices to improve lift station and force main hydraulics and service life. These best practices can be used to improve future force main designs.
This paper was presented at the WEF Collection Systems and Stormwater Conference, April 9-12, 2024.
SpeakerCarpenetti, Edward
Presentation time
14:00:00
14:30:00
Session time
13:30:00
15:00:00
SessionPumping Operations
Session number06
Session locationConnecticut Convention Center, Hartford, Connecticut
TopicAsset Management, Bypass pumping, Collection Systems, Combined Sewer Overflow, Deep Sewer Tunnel, Flow control, Hydrogen Sulfide, Odor and Corrosion Control, Operations And Maintenance, Pump station, forcemain
TopicAsset Management, Bypass pumping, Collection Systems, Combined Sewer Overflow, Deep Sewer Tunnel, Flow control, Hydrogen Sulfide, Odor and Corrosion Control, Operations And Maintenance, Pump station, forcemain
Author(s)
Carpenetti, Edward
Author(s)E. Carpenetti1, S. Hada1, B. McDonald2
Author affiliation(s)Black & Veatch 1; HDR 2
SourceProceedings of the Water Environment Federation
Document typeConference Paper
PublisherWater Environment Federation
Print publication date Apr 2024
DOI10.2175/193864718825159355
Volume / Issue
Content sourceCollection Systems and Stormwater Conference
Copyright2024
Word count17

Actions, changes & tasks

Outstanding Actions

Add action for paragraph

Current Changes

Add signficant change

Current Tasks

Add risk task

Connect with us

Follow us on Facebook
Follow us on Twitter
Connect to us on LinkedIn
Subscribe on YouTube
Powered by Librios Ltd
Powered by Librios Ltd
Authors
Terms of Use
Policies
Help
Accessibility
Contact us
Copyright © 2024 by the Water Environment Federation
Loading items
There are no items to display at the moment.
Something went wrong trying to load these items.
Description: WWTF Digital Boot 180x150
WWTF Digital (180x150)
Created on Jul 02
Websitehttps:/­/­www.wef.org/­wwtf?utm_medium=WWTF&utm_source=AccessWater&utm_campaign=WWTF
180x150
Carpenetti, Edward. How to use condition assessment data to improve force main and lift station design and operation. Water Environment Federation, 2024. Web. 17 Jun. 2025. <https://www.accesswater.org?id=-10102360CITANCHOR>.
Carpenetti, Edward. How to use condition assessment data to improve force main and lift station design and operation. Water Environment Federation, 2024. Accessed June 17, 2025. https://www.accesswater.org/?id=-10102360CITANCHOR.
Carpenetti, Edward
How to use condition assessment data to improve force main and lift station design and operation
Access Water
Water Environment Federation
April 10, 2024
June 17, 2025
https://www.accesswater.org/?id=-10102360CITANCHOR