lastID = -10108638
Skip to main content Skip to top navigation Skip to site search
Top of page
  • My citations options
    Web Back (from Web)
    Chicago Back (from Chicago)
    MLA Back (from MLA)
Close action menu

You need to login to use this feature.

Please wait a moment…
Please wait while we update your results...
Please wait a moment...
Description: Access Water
Context Menu
Description: Phosphorus Sequestration in Biosolids, Nuisance Struvite Control via PAD and...
Phosphorus Sequestration in Biosolids, Nuisance Struvite Control via PAD and Chemical Addition to TH-AD Digestate, and Downstream Effects
  • Browse
  • Compilations
    • Compilations list
  • Subscriptions
Tools

Related contents

Loading related content

Workflow

No linked records yet

X
  • Current: 2024-06-17 15:52:04 Adam Phillips Release
  • 2024-06-17 15:09:48 Adam Phillips
  • 2024-06-17 14:46:38 Adam Phillips
  • 2024-06-17 11:14:35 Adam Phillips
Description: Access Water
  • Browse
  • Compilations
  • Subscriptions
Log in
0
Accessibility Options

Base text size -

This is a sample piece of body text
Larger
Smaller
  • Shopping basket (0)
  • Accessibility options
  • Return to previous
Description: Phosphorus Sequestration in Biosolids, Nuisance Struvite Control via PAD and...
Phosphorus Sequestration in Biosolids, Nuisance Struvite Control via PAD and Chemical Addition to TH-AD Digestate, and Downstream Effects

Phosphorus Sequestration in Biosolids, Nuisance Struvite Control via PAD and Chemical Addition to TH-AD Digestate, and Downstream Effects

Phosphorus Sequestration in Biosolids, Nuisance Struvite Control via PAD and Chemical Addition to TH-AD Digestate, and Downstream Effects

  • New
  • View
  • Details
  • Reader
  • Default
  • Share
  • Email
  • Facebook
  • Twitter
  • LinkedIn
  • New
  • View
  • Default view
  • Reader view
  • Data view
  • Details

This page cannot be printed from here

Please use the dedicated print option from the 'view' drop down menu located in the blue ribbon in the top, right section of the publication.

screenshot of print menu option

Description: Phosphorus Sequestration in Biosolids, Nuisance Struvite Control via PAD and...
Phosphorus Sequestration in Biosolids, Nuisance Struvite Control via PAD and Chemical Addition to TH-AD Digestate, and Downstream Effects
Abstract
Purpose: Struvite and other common precipitates have long posed persistent maintenance and operational challenges at wastewater treatment plants. These precipitates can be enhanced at plants that utilize biological phosphorus removal and can precipitate within anaerobic digesters and on final dewatering equipment which causes damage and decreases treatment efficiency. Struvite can be sequestered as nutrient rich biosolids if properly controlled to remain in the cake. In a digested solids storage tank (DSST) that is in between anaerobic digestion and final dewatering, precipitation can be controlled by manipulating variables such as mixing, aeration of digestate to achieve a shorter solids retention time (SRT) version of post aerobic digestion (PAD) and by chemical addition. Optimizing this via batch and pilot testing can control nuisance struvite and other crystal formation, enhance downstream effects such as increasing phosphorus in the cake, improve biosolids odor profile and cake dryness, reducing polymer demand, and achieve additional volatile solids reduction (VSR).
This research will review findings from batch and pilot scale tests and discuss the nature of these precipitates. Objectives include determining the mechanism that provides optimal phosphorus removal, odor control, cake characteristics, and analyzing the precipitated solids of interest. The presentation will discuss results across batch, pilot, and full-scales and examine the lessons learned of each.

Motivation and Background: The Atlantic Treatment Plant (ATP) in Virginia Beach, VA, operated by the Hampton Roads Sanitation District's (HRSD) is a high-rate facility with an A/O process configuration. In solids handling, a Cambi Thermal Hydrolysis Process (THP) is utilized prior to anaerobic digestion, leading to the formation of scaling precipitates and nuisance struvite. ATP is actively engaged in efforts to control these issues for optimal operational efficiency.
Precipitate formation is determined predominantly by the solids solubility product (Ksp) and the saturation in solution and can be controlled by pH [1]. Manipulation of pH via CO2 stripping from agitation and aeration has successfully been shown to control solubility reactions [2, 3]. Increasing the saturation index via chemical addition can also control precipitation reactions, decrease polymer demand, and improve cake dryness with an SRT of a few hours [4]. Likewise, PAD has been shown to achieve ammonia removal, additional VSR, and break down odor compounds formed in anaerobic digestion at a 5-6 day SRT [5]. Based on these findings, a pilot scale set up (Figure 1) will run at an SRT of 3 days to provide benefits from PAD, but with a longer reaction time that may be more beneficial for phosphorus sequestration. Various mixing, aeration rates, and chemical addition will be manipulated to determine the optimal operation conditions on phosphorus sequestration, cake characteristics, VSR and odors.

Pilot Design and Preliminary Operation: The pilot set up at ATP consists of four tanks. Each tank is 11 feet tall with a volume of about 63 gallons. Simulating the DSST, the tanks are operated as daily batch fed continuously stirred tank reactors (CSTRs) maintained by pump recirculation with a 3-day SRT. The tanks are aerated with fine bubble diffuser membranes which can be operated at constant or intermittent air flow rates, or via Dissolved Oxygen (DO) or pH set points. Preliminary operation has included mixing and aerating tank 1 at a constant airflow rate of 5 L/min, while recording online measurements of temperature, DO, and pH (Figure 2). At this operation, about 50% OP removal across the pilot has been measured with minimal NH3 removal due to lack of pH increase at this airflow rate. Future plans include tracking COD across the pilot, increasing aeration, and the addition of Ca(OH)2 or Mg(OH)2 at various dosages. Batch Testing Results: Prior to running pilot scale tests, some objectives can be mechanistically answered by preliminary batch testing. Chemical Addition: The following test was conducted on a Phipps and Bird PB-900 series Jar Tester at a continuous mixing speed of 300 rpm. Five jars of digestate consisting of a control with no chemical addition, two jars dosed with a carbide lime slurry at Ca2+ + Mg2+/P ratios of 0.5:1 and 1:1, and two jars dosed with thioguard, similarly, at Ca2+ + Mg2+/P ratios of 0.5:1 and 1:1. Chemical dose was injected as a spike at time zero of the test. Analytical measurement of OP-P and pH were determined daily via spectrophotometry (Phosphorus HACH TNTplus Vial Test UHR 2-20 mg-PO4-P/L) and pH bench meter, respectively) (Figure 3).
The pH of the digestate sample was about 7.4 and increased up to a maximum of 8.7 within 24 hours likely due to CO2 stripping from the mixing intensity. OP removal in the control condition with no chemical addition was measured as 68%. The addition of chemical helped to increase OP removal as high as 95%. The digestate pH increasing towards alkaline within the first test day showed the greatest impact on OP removal rate. The higher Ca2+ + Mg2+/P molar ratio tested of 1:1 for both the carbide lime slurry and thioguard had higher OP removal rates than those dosed at lower ratios of 0.5:1. Thioguard compared to the carbide lime slurry overall had a slightly more significant effect on OP removal. The pH decrease that is measured after 24 hours may be due to struvite's production of hydrogen ions in the formation reaction, however, future plans of repeat experiments as well as X-Ray Diffraction for precipitate analysis will further determine this.

Cake Characteristics: A separate test was completed to look at aeration effects on cake characteristics. A sample from the DSST was conditioned, dewatered, and analyzed to evaluate polymer demand and cake solids. Polymer was tested on two buckets of digestate - a gently mixed control bucket and a bucket aerated at about 5 L/min. After 72 hours, polymer was used to condition each digestate. After polymer was added to the solids, it was mixed, and a capillary suction time (CST) instrument was used to find the optimal dose of polymer. The solutions with the lowest CSTs were identified to be the optimal dose of polymer needed and were then dewatered by the centrifuge cup method and measured for cake solids and solids capture, per the Higgins method [6]. In Table 1, the Aerated bucket had a higher polymer optimal dose, TS simulated cake value, and TSS simulated filtrate value compared to the Control bucket while the Control bucket had a higher VS simulated cake value. From these results, the aerated digestate had poorer solids capture when dewatered with the polymer compared to the Control bucket. In addition to cake dryness, improving cake odors will be researched in the future by the characterization of odor profiles and gas sampling the reactor head space using Chromatography Mass Spectrometry solid phase microextraction and Gastec Tubes.

Conclusion: This paper will present the challenges that ATP faces as well as batch and pilot research conducted to combat these issues. Optimization learned on this scale will advance the discussion on similar issues shared by wastewater treatment plants across the country. Further advancements have the possibility to improve plant efficiency and save plant capital costs.
This paper was presented at the WEF Residuals and Biosolids Conference, June 18-21, 2024.
SpeakerHarris, Caitlyn
Presentation time
13:30:00
14:00:00
Session time
13:30:00
15:00:00
SessionNutrient Considerations and Digestion
Session number16
Session locationOklahoma City Convention Center, Oklahoma City, Oklahoma
TopicAnaerobic Digestion, Pilot Scale, Struvite
TopicAnaerobic Digestion, Pilot Scale, Struvite
Author(s)
Harris, Caitlyn
Author(s)C. Harris1, M. Garcia1, D. Gonzalez2, A. Williamson1, B. Ward3, J. Nicholson1, H. Matel1, C. Bott1, C. Wilson1
Author affiliation(s)HRSD 1; HRSD 1; Carollo Engineers 2; HRSD 1; HDR 3; Hampton Roads Sanitation District 1; Hampton Roads Sanitation District (HRSD) 1; HRSD 1; HRSD 1;
SourceProceedings of the Water Environment Federation
Document typeConference Paper
PublisherWater Environment Federation
Print publication date Jun 2024
DOI10.2175/193864718825159414
Volume / Issue
Content sourceResiduals and Biosolids Conference
Copyright2024
Word count19

Purchase price $11.50

Get access
Log in Purchase content Purchase subscription
You may already have access to this content if you have previously purchased this content or have a subscription.
Need to create an account?

You can purchase access to this content but you might want to consider a subscription for a wide variety of items at a substantial discount!

Purchase access to 'Phosphorus Sequestration in Biosolids, Nuisance Struvite Control via PAD and Chemical Addition to TH-AD Digestate, and Downstream Effects'

Add to cart
Purchase a subscription to gain access to 18,000+ Proceeding Papers, 25+ Fact Sheets, 20+ Technical Reports, 50+ magazine articles and select Technical Publications' chapters.
Loading items
There are no items to display at the moment.
Something went wrong trying to load these items.
Description: Phosphorus Sequestration in Biosolids, Nuisance Struvite Control via PAD and...
Phosphorus Sequestration in Biosolids, Nuisance Struvite Control via PAD and Chemical Addition to TH-AD Digestate, and Downstream Effects
Pricing
Non-member price: $11.50
Member price:
-10108638
Get access
-10108638
Log in Purchase content Purchase subscription
You may already have access to this content if you have previously purchased this content or have a subscription.
Need to create an account?

You can purchase access to this content but you might want to consider a subscription for a wide variety of items at a substantial discount!

Purchase access to 'Phosphorus Sequestration in Biosolids, Nuisance Struvite Control via PAD and Chemical Addition to TH-AD Digestate, and Downstream Effects'

Add to cart
Purchase a subscription to gain access to 18,000+ Proceeding Papers, 25+ Fact Sheets, 20+ Technical Reports, 50+ magazine articles and select Technical Publications' chapters.

Details

Description: Phosphorus Sequestration in Biosolids, Nuisance Struvite Control via PAD and...
Phosphorus Sequestration in Biosolids, Nuisance Struvite Control via PAD and Chemical Addition to TH-AD Digestate, and Downstream Effects
Abstract
Purpose: Struvite and other common precipitates have long posed persistent maintenance and operational challenges at wastewater treatment plants. These precipitates can be enhanced at plants that utilize biological phosphorus removal and can precipitate within anaerobic digesters and on final dewatering equipment which causes damage and decreases treatment efficiency. Struvite can be sequestered as nutrient rich biosolids if properly controlled to remain in the cake. In a digested solids storage tank (DSST) that is in between anaerobic digestion and final dewatering, precipitation can be controlled by manipulating variables such as mixing, aeration of digestate to achieve a shorter solids retention time (SRT) version of post aerobic digestion (PAD) and by chemical addition. Optimizing this via batch and pilot testing can control nuisance struvite and other crystal formation, enhance downstream effects such as increasing phosphorus in the cake, improve biosolids odor profile and cake dryness, reducing polymer demand, and achieve additional volatile solids reduction (VSR).
This research will review findings from batch and pilot scale tests and discuss the nature of these precipitates. Objectives include determining the mechanism that provides optimal phosphorus removal, odor control, cake characteristics, and analyzing the precipitated solids of interest. The presentation will discuss results across batch, pilot, and full-scales and examine the lessons learned of each.

Motivation and Background: The Atlantic Treatment Plant (ATP) in Virginia Beach, VA, operated by the Hampton Roads Sanitation District's (HRSD) is a high-rate facility with an A/O process configuration. In solids handling, a Cambi Thermal Hydrolysis Process (THP) is utilized prior to anaerobic digestion, leading to the formation of scaling precipitates and nuisance struvite. ATP is actively engaged in efforts to control these issues for optimal operational efficiency.
Precipitate formation is determined predominantly by the solids solubility product (Ksp) and the saturation in solution and can be controlled by pH [1]. Manipulation of pH via CO2 stripping from agitation and aeration has successfully been shown to control solubility reactions [2, 3]. Increasing the saturation index via chemical addition can also control precipitation reactions, decrease polymer demand, and improve cake dryness with an SRT of a few hours [4]. Likewise, PAD has been shown to achieve ammonia removal, additional VSR, and break down odor compounds formed in anaerobic digestion at a 5-6 day SRT [5]. Based on these findings, a pilot scale set up (Figure 1) will run at an SRT of 3 days to provide benefits from PAD, but with a longer reaction time that may be more beneficial for phosphorus sequestration. Various mixing, aeration rates, and chemical addition will be manipulated to determine the optimal operation conditions on phosphorus sequestration, cake characteristics, VSR and odors.

Pilot Design and Preliminary Operation: The pilot set up at ATP consists of four tanks. Each tank is 11 feet tall with a volume of about 63 gallons. Simulating the DSST, the tanks are operated as daily batch fed continuously stirred tank reactors (CSTRs) maintained by pump recirculation with a 3-day SRT. The tanks are aerated with fine bubble diffuser membranes which can be operated at constant or intermittent air flow rates, or via Dissolved Oxygen (DO) or pH set points. Preliminary operation has included mixing and aerating tank 1 at a constant airflow rate of 5 L/min, while recording online measurements of temperature, DO, and pH (Figure 2). At this operation, about 50% OP removal across the pilot has been measured with minimal NH3 removal due to lack of pH increase at this airflow rate. Future plans include tracking COD across the pilot, increasing aeration, and the addition of Ca(OH)2 or Mg(OH)2 at various dosages. Batch Testing Results: Prior to running pilot scale tests, some objectives can be mechanistically answered by preliminary batch testing. Chemical Addition: The following test was conducted on a Phipps and Bird PB-900 series Jar Tester at a continuous mixing speed of 300 rpm. Five jars of digestate consisting of a control with no chemical addition, two jars dosed with a carbide lime slurry at Ca2+ + Mg2+/P ratios of 0.5:1 and 1:1, and two jars dosed with thioguard, similarly, at Ca2+ + Mg2+/P ratios of 0.5:1 and 1:1. Chemical dose was injected as a spike at time zero of the test. Analytical measurement of OP-P and pH were determined daily via spectrophotometry (Phosphorus HACH TNTplus Vial Test UHR 2-20 mg-PO4-P/L) and pH bench meter, respectively) (Figure 3).
The pH of the digestate sample was about 7.4 and increased up to a maximum of 8.7 within 24 hours likely due to CO2 stripping from the mixing intensity. OP removal in the control condition with no chemical addition was measured as 68%. The addition of chemical helped to increase OP removal as high as 95%. The digestate pH increasing towards alkaline within the first test day showed the greatest impact on OP removal rate. The higher Ca2+ + Mg2+/P molar ratio tested of 1:1 for both the carbide lime slurry and thioguard had higher OP removal rates than those dosed at lower ratios of 0.5:1. Thioguard compared to the carbide lime slurry overall had a slightly more significant effect on OP removal. The pH decrease that is measured after 24 hours may be due to struvite's production of hydrogen ions in the formation reaction, however, future plans of repeat experiments as well as X-Ray Diffraction for precipitate analysis will further determine this.

Cake Characteristics: A separate test was completed to look at aeration effects on cake characteristics. A sample from the DSST was conditioned, dewatered, and analyzed to evaluate polymer demand and cake solids. Polymer was tested on two buckets of digestate - a gently mixed control bucket and a bucket aerated at about 5 L/min. After 72 hours, polymer was used to condition each digestate. After polymer was added to the solids, it was mixed, and a capillary suction time (CST) instrument was used to find the optimal dose of polymer. The solutions with the lowest CSTs were identified to be the optimal dose of polymer needed and were then dewatered by the centrifuge cup method and measured for cake solids and solids capture, per the Higgins method [6]. In Table 1, the Aerated bucket had a higher polymer optimal dose, TS simulated cake value, and TSS simulated filtrate value compared to the Control bucket while the Control bucket had a higher VS simulated cake value. From these results, the aerated digestate had poorer solids capture when dewatered with the polymer compared to the Control bucket. In addition to cake dryness, improving cake odors will be researched in the future by the characterization of odor profiles and gas sampling the reactor head space using Chromatography Mass Spectrometry solid phase microextraction and Gastec Tubes.

Conclusion: This paper will present the challenges that ATP faces as well as batch and pilot research conducted to combat these issues. Optimization learned on this scale will advance the discussion on similar issues shared by wastewater treatment plants across the country. Further advancements have the possibility to improve plant efficiency and save plant capital costs.
This paper was presented at the WEF Residuals and Biosolids Conference, June 18-21, 2024.
SpeakerHarris, Caitlyn
Presentation time
13:30:00
14:00:00
Session time
13:30:00
15:00:00
SessionNutrient Considerations and Digestion
Session number16
Session locationOklahoma City Convention Center, Oklahoma City, Oklahoma
TopicAnaerobic Digestion, Pilot Scale, Struvite
TopicAnaerobic Digestion, Pilot Scale, Struvite
Author(s)
Harris, Caitlyn
Author(s)C. Harris1, M. Garcia1, D. Gonzalez2, A. Williamson1, B. Ward3, J. Nicholson1, H. Matel1, C. Bott1, C. Wilson1
Author affiliation(s)HRSD 1; HRSD 1; Carollo Engineers 2; HRSD 1; HDR 3; Hampton Roads Sanitation District 1; Hampton Roads Sanitation District (HRSD) 1; HRSD 1; HRSD 1;
SourceProceedings of the Water Environment Federation
Document typeConference Paper
PublisherWater Environment Federation
Print publication date Jun 2024
DOI10.2175/193864718825159414
Volume / Issue
Content sourceResiduals and Biosolids Conference
Copyright2024
Word count19

Actions, changes & tasks

Outstanding Actions

Add action for paragraph

Current Changes

Add signficant change

Current Tasks

Add risk task

Connect with us

Follow us on Facebook
Follow us on Twitter
Connect to us on LinkedIn
Subscribe on YouTube
Powered by Librios Ltd
Powered by Librios Ltd
Authors
Terms of Use
Policies
Help
Accessibility
Contact us
Copyright © 2024 by the Water Environment Federation
Loading items
There are no items to display at the moment.
Something went wrong trying to load these items.
Description: WWTF Digital Boot 180x150
WWTF Digital (180x150)
Created on Jul 02
Websitehttps:/­/­www.wef.org/­wwtf?utm_medium=WWTF&utm_source=AccessWater&utm_campaign=WWTF
180x150
Harris, Caitlyn. Phosphorus Sequestration in Biosolids, Nuisance Struvite Control via PAD and Chemical Addition to TH-AD Digestate, and Downstream Effects. Water Environment Federation, 2024. Web. 16 Jun. 2025. <https://www.accesswater.org?id=-10108638CITANCHOR>.
Harris, Caitlyn. Phosphorus Sequestration in Biosolids, Nuisance Struvite Control via PAD and Chemical Addition to TH-AD Digestate, and Downstream Effects. Water Environment Federation, 2024. Accessed June 16, 2025. https://www.accesswater.org/?id=-10108638CITANCHOR.
Harris, Caitlyn
Phosphorus Sequestration in Biosolids, Nuisance Struvite Control via PAD and Chemical Addition to TH-AD Digestate, and Downstream Effects
Access Water
Water Environment Federation
June 20, 2024
June 16, 2025
https://www.accesswater.org/?id=-10108638CITANCHOR