Access Water | Retrofitting MABRs in existing treatment infrastructure: What you need to...
lastID = -10128143
Skip to main content Skip to top navigation Skip to site search
Top of page
  • My citations options
    Web Back (from Web)
    Chicago Back (from Chicago)
    MLA Back (from MLA)
Close action menu

You need to login to use this feature.

Please wait a moment…
Please wait while we update your results...
Please wait a moment...
Loading icon
Description: Access Water
Context Menu
Description: Retrofitting MABRs in existing treatment infrastructure: What you need to know
Retrofitting MABRs in existing treatment infrastructure: What you need to know
  • Browse
  • Compilations
    • Compilations list
  • Subscriptions
Tools

Related contents

Loading related content

Workflow

No linked records yet

X
  • Current: 2026-09-25 14:57:05 Chris Lewis Continuous release
  • 2026-09-11 09:59:56 Adam Phillips
Description: Access Water
  • Browse
  • Compilations
  • Subscriptions
Log in
0
Accessibility Options

Base text size -

This is a sample piece of body text
Larger
Smaller
  • Shopping basket (0)
  • Accessibility options
  • Return to previous
Description: Retrofitting MABRs in existing treatment infrastructure: What you need to know
Retrofitting MABRs in existing treatment infrastructure: What you need to know

Retrofitting MABRs in existing treatment infrastructure: What you need to know

Retrofitting MABRs in existing treatment infrastructure: What you need to know

  • New
  • View
  • Details
  • Reader
  • Default
  • Share
  • Email
  • Facebook
  • Twitter
  • LinkedIn
  • New
  • View
  • Default view
  • Reader view
  • Data view
  • Details

This page cannot be printed from here

Please use the dedicated print option from the 'view' drop down menu located in the blue ribbon in the top, right section of the publication.

screenshot of print menu option

Description: Retrofitting MABRs in existing treatment infrastructure: What you need to know
Retrofitting MABRs in existing treatment infrastructure: What you need to know
Abstract
[b]Background[/b] Membrane aerated biofilm reactors (MABRs) are bubbleless aeration systems where oxygen is supplied through gas-permeable membranes that also serve as biofilm media. MABRs offer several benefits such as higher oxygen transfer efficiency, reduced energy use, improved winter nitrification, simultaneous nitrification-denitrification, mitigated N₂O emissions, quick installation, and smaller footprint.¹˒² These advantages make MABRs a leading intensification technology with growing full-scale adoption worldwide. MABRs are often retrofitted into existing treatment trains to boost capacity with minimal expansion. Because every plant has unique characteristics, site specific considerations are critical for successful MABR installation. Drawing on our experience from multiple MABR projects, this abstract consolidates the key lessons learned. With two full-scale plants that were the first Canadian and first Australian MABR installations as case studies, this paper provides practical design and operational insights that can help utilities make informed decisions. [b]Study Sites[/b] The study sites are full-scale MABR facilities at Hespeler WRRF (Canada) and Elanora STP (Australia). Table 1 and Figure 1 present the site details and process flowsheets. Hespeler's upgrade was completed in Aug 2022, supported by long-term monitoring (Jan 2020–Apr 2024) to benchmark plant performance before and after the upgrade. Elanora's commissioning is scheduled for 2026 with a following performance testing. [b]Study findings[/b] Existing vs. new tanks: Retrofitting existing reactors can pose challenges. MABR cassette dimensions may create unused volume in deep tanks. At Elanora, a high clarifier-to-bioreactor ratio required a large aerobic fraction, limiting anoxic volume and cassette count. At Hespeler, existing aeration tank walls could not support cassettes, so a new 637 m³ anoxic tank was built. Despite new construction, the upgrade cost was about half that of aeration tank expansion due to MABR's compact footprint. Mixing design: MABR tank mixing needs due considerations to avoid solids settling. At Hespeler, initial jet mixers and intermittent air sparging were insufficient, causing sludge accumulation and ammonia release. Adding intermittently aerated coarse bubble diffusers resolved the issue. Elanora adopted this approach upfront. CFD modeling during design is recommended to ensure proper mixing. Biofilm thickness management: At Hespeler, an increased N loading did not boost nitrification as expected. Increasing wastewater loading also increased the carbon supply and grew thick biofilms that restricted ammonia diffusion. Thus, managing biofilm thickness appropriate scouring intensity under dynamic loading conditions is critical for optimal MABR operations. There can be spatial variations with MABR cassettes in a plug flow tank showing a longitudinal increase in biofilm thickness (Figure 3). Cassettes at the front the receives the higher carbon loading develop a thicker biofilm. This can be detrimental because the front cassettes have the highest NH4 gradient to drive the nitrification rate which is dampened by thick biofilms. Thicker biofilms could also support sulfur reducing organisms which compete with denitrification for carbon and can cause odor. Designing for higher scouring at the front could alleviate these issues. Monitoring biofilm through direct sampling or pressure decay tests can inform operations, though these methods are costly. Emerging data-driven techniques using effluent NH₃ and exhaust O₂ may offer practical alternatives.³˒⁴ Seeding effect in SRT design: MABR biofilms act as 'nitrifier nurseries' for the whole plant, reducing aerobic SRT (aSRT) required for downstream nitrification. Figure 5 shows the critical role of the MABR NH₃ removal fraction and biofilm SRT (sloughing rate) in maximizing the nitrifier seeding effect. At Elanora, these factors guided the design of MABR surface area and decreased the post-upgrade aSRT from 10 to 6 d. At Hespeler, because of the seeding effect, winter effluent NH₄ remained <10 mg/L at 4–5 d SRT and 10–12°C.² Moreover, the average NH4 removal efficiency in the downstream aeration tank increased from 52% to 71% with an increase in MABR scouring intensity (Figure 4). Hence, the overall SRT design should consider the operational airflows and scouring intensity in determining safety factor. Downstream aeration impacts: MABRs influence more than nitrification in the downstream processes. At Hespeler, MABRs removed over half the TKN and significant carbon through denitrification that the aeration tank airflow was halved (Figure 6). Even at minimum blower settings, the post upgrade DO in the aeration tank remained uniformly high (>2 mg/L) throughout as opposed to a longitudinal increasing trend before upgrade (Figure 6). These findings indicate that, i) MABR reduced the operational cost related to process air by half, ii) MABRs can offer additional aeration capacity for any increase in future loading, and iii) having appropriately variable speed blowers can help realize additional electricity savings. In conclusion, this study consolidates real-world lessons on design trade-offs, operational strategies, and site-specific considerations for retrofitting MABRs. The full paper will include additional factors to consider when integrating other intensification technologies such as MBR and hydrocyclones.
This paper was presented at WEFTEC 2026 in New Orleans, Louisiana.
Presentation time
13:30:00
14:00:00
Session time
13:30:00
15:00:00
SessionCharting the Future of MABR Technology 
Session locationErnest N. Morial Convention Center
TopicFacility Operations and Maintenance, Municipal Wastewater Treatment Design, Nutrients
TopicFacility Operations and Maintenance, Municipal Wastewater Treatment Design, Nutrients
Author(s)
Lakshminarasimman, Narasimman, Astrand, Niclas, Gloag, Graham, Staib, Cameron
Author(s)N. Lakshminarasimman1, N. Astrand1, G. Gloag1, C. Staib2
Author affiliation(s)Stantec Inc., 1Stantec Inc., 1Stantec, 1
SourceProceedings of the Water Environment Federation
Document typeConference Paper
PublisherWater Environment Federation
Print publication date Sep 2026
DOI10.2175/193864718825160308
Volume / Issue
Content sourceWEFTEC
Copyright2026
Word count12

Purchase price $11.50

Get access
Log in Purchase content Purchase subscription
You may already have access to this content if you have previously purchased this content or have a subscription.
Need to create an account?

You can purchase access to this content but you might want to consider a subscription for a wide variety of items at a substantial discount!

Purchase access to 'Retrofitting MABRs in existing treatment infrastructure: What you need to know'

Add to cart
Purchase a subscription to gain access to 18,000+ Proceeding Papers, 25+ Fact Sheets, 20+ Technical Reports, 50+ magazine articles and select Technical Publications' chapters.
Loading items
There are no items to display at the moment.
Something went wrong trying to load these items.
Description: Retrofitting MABRs in existing treatment infrastructure: What you need to know
Retrofitting MABRs in existing treatment infrastructure: What you need to know
Pricing
Non-member price: $11.50
Member price:
-10128143
Get access
-10128143
Log in Purchase content Purchase subscription
You may already have access to this content if you have previously purchased this content or have a subscription.
Need to create an account?

You can purchase access to this content but you might want to consider a subscription for a wide variety of items at a substantial discount!

Purchase access to 'Retrofitting MABRs in existing treatment infrastructure: What you need to know'

Add to cart
Purchase a subscription to gain access to 18,000+ Proceeding Papers, 25+ Fact Sheets, 20+ Technical Reports, 50+ magazine articles and select Technical Publications' chapters.

Details

Description: Retrofitting MABRs in existing treatment infrastructure: What you need to know
Retrofitting MABRs in existing treatment infrastructure: What you need to know
Abstract
[b]Background[/b] Membrane aerated biofilm reactors (MABRs) are bubbleless aeration systems where oxygen is supplied through gas-permeable membranes that also serve as biofilm media. MABRs offer several benefits such as higher oxygen transfer efficiency, reduced energy use, improved winter nitrification, simultaneous nitrification-denitrification, mitigated N₂O emissions, quick installation, and smaller footprint.¹˒² These advantages make MABRs a leading intensification technology with growing full-scale adoption worldwide. MABRs are often retrofitted into existing treatment trains to boost capacity with minimal expansion. Because every plant has unique characteristics, site specific considerations are critical for successful MABR installation. Drawing on our experience from multiple MABR projects, this abstract consolidates the key lessons learned. With two full-scale plants that were the first Canadian and first Australian MABR installations as case studies, this paper provides practical design and operational insights that can help utilities make informed decisions. [b]Study Sites[/b] The study sites are full-scale MABR facilities at Hespeler WRRF (Canada) and Elanora STP (Australia). Table 1 and Figure 1 present the site details and process flowsheets. Hespeler's upgrade was completed in Aug 2022, supported by long-term monitoring (Jan 2020–Apr 2024) to benchmark plant performance before and after the upgrade. Elanora's commissioning is scheduled for 2026 with a following performance testing. [b]Study findings[/b] Existing vs. new tanks: Retrofitting existing reactors can pose challenges. MABR cassette dimensions may create unused volume in deep tanks. At Elanora, a high clarifier-to-bioreactor ratio required a large aerobic fraction, limiting anoxic volume and cassette count. At Hespeler, existing aeration tank walls could not support cassettes, so a new 637 m³ anoxic tank was built. Despite new construction, the upgrade cost was about half that of aeration tank expansion due to MABR's compact footprint. Mixing design: MABR tank mixing needs due considerations to avoid solids settling. At Hespeler, initial jet mixers and intermittent air sparging were insufficient, causing sludge accumulation and ammonia release. Adding intermittently aerated coarse bubble diffusers resolved the issue. Elanora adopted this approach upfront. CFD modeling during design is recommended to ensure proper mixing. Biofilm thickness management: At Hespeler, an increased N loading did not boost nitrification as expected. Increasing wastewater loading also increased the carbon supply and grew thick biofilms that restricted ammonia diffusion. Thus, managing biofilm thickness appropriate scouring intensity under dynamic loading conditions is critical for optimal MABR operations. There can be spatial variations with MABR cassettes in a plug flow tank showing a longitudinal increase in biofilm thickness (Figure 3). Cassettes at the front the receives the higher carbon loading develop a thicker biofilm. This can be detrimental because the front cassettes have the highest NH4 gradient to drive the nitrification rate which is dampened by thick biofilms. Thicker biofilms could also support sulfur reducing organisms which compete with denitrification for carbon and can cause odor. Designing for higher scouring at the front could alleviate these issues. Monitoring biofilm through direct sampling or pressure decay tests can inform operations, though these methods are costly. Emerging data-driven techniques using effluent NH₃ and exhaust O₂ may offer practical alternatives.³˒⁴ Seeding effect in SRT design: MABR biofilms act as 'nitrifier nurseries' for the whole plant, reducing aerobic SRT (aSRT) required for downstream nitrification. Figure 5 shows the critical role of the MABR NH₃ removal fraction and biofilm SRT (sloughing rate) in maximizing the nitrifier seeding effect. At Elanora, these factors guided the design of MABR surface area and decreased the post-upgrade aSRT from 10 to 6 d. At Hespeler, because of the seeding effect, winter effluent NH₄ remained <10 mg/L at 4–5 d SRT and 10–12°C.² Moreover, the average NH4 removal efficiency in the downstream aeration tank increased from 52% to 71% with an increase in MABR scouring intensity (Figure 4). Hence, the overall SRT design should consider the operational airflows and scouring intensity in determining safety factor. Downstream aeration impacts: MABRs influence more than nitrification in the downstream processes. At Hespeler, MABRs removed over half the TKN and significant carbon through denitrification that the aeration tank airflow was halved (Figure 6). Even at minimum blower settings, the post upgrade DO in the aeration tank remained uniformly high (>2 mg/L) throughout as opposed to a longitudinal increasing trend before upgrade (Figure 6). These findings indicate that, i) MABR reduced the operational cost related to process air by half, ii) MABRs can offer additional aeration capacity for any increase in future loading, and iii) having appropriately variable speed blowers can help realize additional electricity savings. In conclusion, this study consolidates real-world lessons on design trade-offs, operational strategies, and site-specific considerations for retrofitting MABRs. The full paper will include additional factors to consider when integrating other intensification technologies such as MBR and hydrocyclones.
This paper was presented at WEFTEC 2026 in New Orleans, Louisiana.
Presentation time
13:30:00
14:00:00
Session time
13:30:00
15:00:00
SessionCharting the Future of MABR Technology 
Session locationErnest N. Morial Convention Center
TopicFacility Operations and Maintenance, Municipal Wastewater Treatment Design, Nutrients
TopicFacility Operations and Maintenance, Municipal Wastewater Treatment Design, Nutrients
Author(s)
Lakshminarasimman, Narasimman, Astrand, Niclas, Gloag, Graham, Staib, Cameron
Author(s)N. Lakshminarasimman1, N. Astrand1, G. Gloag1, C. Staib2
Author affiliation(s)Stantec Inc., 1Stantec Inc., 1Stantec, 1
SourceProceedings of the Water Environment Federation
Document typeConference Paper
PublisherWater Environment Federation
Print publication date Sep 2026
DOI10.2175/193864718825160308
Volume / Issue
Content sourceWEFTEC
Copyright2026
Word count12

Actions, changes & tasks

Outstanding Actions

Add action for paragraph

Current Changes

Add signficant change

Current Tasks

Add risk task

Connect with us

Follow us on Facebook
Follow us on Twitter
Connect to us on LinkedIn
Subscribe on YouTube
Powered by Librios Ltd
Powered by Librios Ltd
Authors
Terms of Use
Policies
Help
Accessibility
Contact us
Copyright © 2026 by the Water Environment Federation
Loading items
There are no items to display at the moment.
Something went wrong trying to load these items.
Description: WWTF Digital Boot 180x150
WWTF Digital (180x150)
Created on Jul 02
Websitehttps:/­/­www.wef.org/­wwtf?utm_medium=WWTF&utm_source=AccessWater&utm_campaign=WWTF
180x150
Lakshminarasimman, Narasimman. Retrofitting MABRs in existing treatment infrastructure: What you need to know. Water Environment Federation, 2026. Web. 24 Nov. 2026. <https://www.accesswater.org?id=-10128143CITANCHOR>.
Lakshminarasimman, Narasimman. Retrofitting MABRs in existing treatment infrastructure: What you need to know. Water Environment Federation, 2026. Accessed November 24, 2026. https://www.accesswater.org/?id=-10128143CITANCHOR.
Lakshminarasimman, Narasimman
Retrofitting MABRs in existing treatment infrastructure: What you need to know
Access Water
Water Environment Federation
September 30, 2026
November 24, 2026
https://www.accesswater.org/?id=-10128143CITANCHOR