Access Water | Three Decades of Experience with Ammonia-Based Aeration Control
lastID = -10128244
Skip to main content Skip to top navigation Skip to site search
Top of page
  • My citations options
    Web Back (from Web)
    Chicago Back (from Chicago)
    MLA Back (from MLA)
Close action menu

You need to login to use this feature.

Please wait a moment…
Please wait while we update your results...
Please wait a moment...
Loading icon
Description: Access Water
Context Menu
Description: Three Decades of Experience with Ammonia-Based Aeration Control
Three Decades of Experience with Ammonia-Based Aeration Control
  • Browse
  • Compilations
    • Compilations list
  • Subscriptions
Tools

Related contents

Loading related content

Workflow

No linked records yet

X
  • Current: 2026-09-25 14:57:43 Chris Lewis Continuous release
  • 2026-09-11 10:00:53 Adam Phillips
Description: Access Water
  • Browse
  • Compilations
  • Subscriptions
Log in
0
Accessibility Options

Base text size -

This is a sample piece of body text
Larger
Smaller
  • Shopping basket (0)
  • Accessibility options
  • Return to previous
Description: Three Decades of Experience with Ammonia-Based Aeration Control
Three Decades of Experience with Ammonia-Based Aeration Control

Three Decades of Experience with Ammonia-Based Aeration Control

Three Decades of Experience with Ammonia-Based Aeration Control

  • New
  • View
  • Details
  • Reader
  • Default
  • Share
  • Email
  • Facebook
  • Twitter
  • LinkedIn
  • New
  • View
  • Default view
  • Reader view
  • Data view
  • Details

This page cannot be printed from here

Please use the dedicated print option from the 'view' drop down menu located in the blue ribbon in the top, right section of the publication.

screenshot of print menu option

Description: Three Decades of Experience with Ammonia-Based Aeration Control
Three Decades of Experience with Ammonia-Based Aeration Control
Abstract
[b]BACKGROUND[/b] Ammonia based aeration control (ABAC) has become a cornerstone for improving energy efficiency in activated sludge systems while maintaining effluent ammonia compliance. Over the past decades, advances in online sensing, automation, and control logic have enabled widespread implementation of ABAC at full scale. Nevertheless, many facilities report unstable controller behavior, recurring ammonia breakthrough events, or energy savings that fall short of expectations. These shortcomings are often attributed to instrumentation or tuning issues, while the underlying bio-chemical processes, equipment, and control logic constraints governing ABAC performance remain insufficiently recognized. This paper synthesizes three decades of operational experience with ABAC design, commissioning, troubleshooting, and long-term operation across municipal wastewater treatment facilities, with particular emphasis on nitrification fundamentals, control authority, and aeration system architecture. [b]NITRIFICATION FUNDAMENTALS[/b] A review of nitrification fundamentals shows that nitrifier mass, governed by average ammonia loading and aerobic solids retention time (SRT), is the primary determinant of process capacity. Dissolved oxygen (DO) related kinetic limitation occurs at relatively low concentrations; however, at DO levels near 2 mg/L, ammonia oxidation rates commonly reach approximately 80% of their maximum values (Figure 1). Beyond this range, additional aeration yields diminishing ammonia removal benefits while disproportionately increasing energy demand. As a result, most short-term effluent ammonia excursions observed in fully aerated plants are not caused by insufficient oxygen supply, but by transient imbalances between influent ammonia loads and the available mass of nitrifying biomass. The slow dynamics of nitrifier growth further limit the ability of aeration control to compensate for short term load increases, underscoring the inherently one sided control authority of aeration systems: Reducing the DO in reactors allows for completely stopping nitrification whereas DO concentrations above say 2 mg/L have very limited impact on ammonia removal (Figure 2). [b]PROBLEM STATEMENT[/b] Full scale observations demonstrate that equivalent effluent ammonia targets can be achieved using multiple combinations of DO concentration and aerobic SRT (Figure 3), illustrating the operational space available to operators. Failure to explicitly define which operating point best aligns with plant objectives, such as energy minimization, stabilization of effluent ammonia peaks, or support of simultaneous nitrification-denitrification, can result in aggressive or oscillatory controller behavior. This effect is particularly pronounced under low SRT conditions, where ABAC may exhibit on–off cycling that cannot be resolved through increased aeration intensity alone. In such cases, biological limitations dominate the system response, and controller action must be interpreted within that context. High-SRT conditions often cause the ammonia controllers to calculate low DO setpoints causing the resulting airflows to hit lower limits for mixing or airflow per diffuser. If these lower controller bounds are hit, the DO setpoints cannot be maintained, impacting the whole aeration system in a ripple effect. [b]ABAC SOLUTIONS[/b] The paper presents proven ABA control solutions, including cascade and parallel cascade configurations for the air distribution portion integrating ammonia, DO, and airflow control loops (Figures 4 & 5). Special attention is given to most-open-valve (MOV) selectors and controllers as MOV coordinates between air supply and air distribution controls but may cause insufficient performance if not properly designed (Figure 6). The air supply controls require sufficient blower capacity but for ABAC, turn down limits are typically of higher importance. Case examples highlight the importance of correctly defining manipulated variable bounds, preventing primary and secondary integral windup (Carlsson et al., 2017), avoiding external manipulation of controller outputs, and ensuring that the control logic reflects the intended cascade structure rather than isolated process logic embedded in PLC code. Additional lessons address the impacts of diffuser density, oversimplified pressure control strategies, and inadequate blower scheduling on overall ABAC performance. [b]TAKE HOME MESSAGE[/b] Successful ABAC implementation requires early definition of operational objectives, a detailed understanding of process, mechanical, and control constraints, and coordinated involvement of domain experts throughout design, implementation, and commissioning. Comprehensive documentation, SCADA visualization, and dedicated operator training on control concepts and performance monitoring are essential to long-term operational robustness. When implemented in alignment with process, mechanical, and control fundamentals, ABAC can consistently reduce energy consumption, limit effluent ammonia peaks, enhance process stability, and provide a flexible platform for future control advancements.
This paper was presented at WEFTEC 2026 in New Orleans, Louisiana.
Presentation time
13:30:00
13:45:00
Session time
13:30:00
15:00:00
SessionAmmonia-Based Aeration Control in Practice – Lessons Learned  
Session locationErnest N. Morial Convention Center
TopicFacility Operations and Maintenance, Municipal Wastewater Treatment Design
TopicFacility Operations and Maintenance, Municipal Wastewater Treatment Design
Author(s)
Rieger, Leiv, Schraa, Oliver
Author(s)L. Rieger1, O. Schraa1
Author affiliation(s)Jacobs Solutions Inc., 1Jacobs, 1
SourceProceedings of the Water Environment Federation
Document typeConference Paper
PublisherWater Environment Federation
Print publication date Sep 2026
DOI10.2175/193864718825160409
Volume / Issue
Content sourceWEFTEC
Copyright2026
Word count9

Purchase price $11.50

Get access
Log in Purchase content Purchase subscription
You may already have access to this content if you have previously purchased this content or have a subscription.
Need to create an account?

You can purchase access to this content but you might want to consider a subscription for a wide variety of items at a substantial discount!

Purchase access to 'Three Decades of Experience with Ammonia-Based Aeration Control'

Add to cart
Purchase a subscription to gain access to 18,000+ Proceeding Papers, 25+ Fact Sheets, 20+ Technical Reports, 50+ magazine articles and select Technical Publications' chapters.
Loading items
There are no items to display at the moment.
Something went wrong trying to load these items.
Description: Three Decades of Experience with Ammonia-Based Aeration Control
Three Decades of Experience with Ammonia-Based Aeration Control
Pricing
Non-member price: $11.50
Member price:
-10128244
Get access
-10128244
Log in Purchase content Purchase subscription
You may already have access to this content if you have previously purchased this content or have a subscription.
Need to create an account?

You can purchase access to this content but you might want to consider a subscription for a wide variety of items at a substantial discount!

Purchase access to 'Three Decades of Experience with Ammonia-Based Aeration Control'

Add to cart
Purchase a subscription to gain access to 18,000+ Proceeding Papers, 25+ Fact Sheets, 20+ Technical Reports, 50+ magazine articles and select Technical Publications' chapters.

Details

Description: Three Decades of Experience with Ammonia-Based Aeration Control
Three Decades of Experience with Ammonia-Based Aeration Control
Abstract
[b]BACKGROUND[/b] Ammonia based aeration control (ABAC) has become a cornerstone for improving energy efficiency in activated sludge systems while maintaining effluent ammonia compliance. Over the past decades, advances in online sensing, automation, and control logic have enabled widespread implementation of ABAC at full scale. Nevertheless, many facilities report unstable controller behavior, recurring ammonia breakthrough events, or energy savings that fall short of expectations. These shortcomings are often attributed to instrumentation or tuning issues, while the underlying bio-chemical processes, equipment, and control logic constraints governing ABAC performance remain insufficiently recognized. This paper synthesizes three decades of operational experience with ABAC design, commissioning, troubleshooting, and long-term operation across municipal wastewater treatment facilities, with particular emphasis on nitrification fundamentals, control authority, and aeration system architecture. [b]NITRIFICATION FUNDAMENTALS[/b] A review of nitrification fundamentals shows that nitrifier mass, governed by average ammonia loading and aerobic solids retention time (SRT), is the primary determinant of process capacity. Dissolved oxygen (DO) related kinetic limitation occurs at relatively low concentrations; however, at DO levels near 2 mg/L, ammonia oxidation rates commonly reach approximately 80% of their maximum values (Figure 1). Beyond this range, additional aeration yields diminishing ammonia removal benefits while disproportionately increasing energy demand. As a result, most short-term effluent ammonia excursions observed in fully aerated plants are not caused by insufficient oxygen supply, but by transient imbalances between influent ammonia loads and the available mass of nitrifying biomass. The slow dynamics of nitrifier growth further limit the ability of aeration control to compensate for short term load increases, underscoring the inherently one sided control authority of aeration systems: Reducing the DO in reactors allows for completely stopping nitrification whereas DO concentrations above say 2 mg/L have very limited impact on ammonia removal (Figure 2). [b]PROBLEM STATEMENT[/b] Full scale observations demonstrate that equivalent effluent ammonia targets can be achieved using multiple combinations of DO concentration and aerobic SRT (Figure 3), illustrating the operational space available to operators. Failure to explicitly define which operating point best aligns with plant objectives, such as energy minimization, stabilization of effluent ammonia peaks, or support of simultaneous nitrification-denitrification, can result in aggressive or oscillatory controller behavior. This effect is particularly pronounced under low SRT conditions, where ABAC may exhibit on–off cycling that cannot be resolved through increased aeration intensity alone. In such cases, biological limitations dominate the system response, and controller action must be interpreted within that context. High-SRT conditions often cause the ammonia controllers to calculate low DO setpoints causing the resulting airflows to hit lower limits for mixing or airflow per diffuser. If these lower controller bounds are hit, the DO setpoints cannot be maintained, impacting the whole aeration system in a ripple effect. [b]ABAC SOLUTIONS[/b] The paper presents proven ABA control solutions, including cascade and parallel cascade configurations for the air distribution portion integrating ammonia, DO, and airflow control loops (Figures 4 & 5). Special attention is given to most-open-valve (MOV) selectors and controllers as MOV coordinates between air supply and air distribution controls but may cause insufficient performance if not properly designed (Figure 6). The air supply controls require sufficient blower capacity but for ABAC, turn down limits are typically of higher importance. Case examples highlight the importance of correctly defining manipulated variable bounds, preventing primary and secondary integral windup (Carlsson et al., 2017), avoiding external manipulation of controller outputs, and ensuring that the control logic reflects the intended cascade structure rather than isolated process logic embedded in PLC code. Additional lessons address the impacts of diffuser density, oversimplified pressure control strategies, and inadequate blower scheduling on overall ABAC performance. [b]TAKE HOME MESSAGE[/b] Successful ABAC implementation requires early definition of operational objectives, a detailed understanding of process, mechanical, and control constraints, and coordinated involvement of domain experts throughout design, implementation, and commissioning. Comprehensive documentation, SCADA visualization, and dedicated operator training on control concepts and performance monitoring are essential to long-term operational robustness. When implemented in alignment with process, mechanical, and control fundamentals, ABAC can consistently reduce energy consumption, limit effluent ammonia peaks, enhance process stability, and provide a flexible platform for future control advancements.
This paper was presented at WEFTEC 2026 in New Orleans, Louisiana.
Presentation time
13:30:00
13:45:00
Session time
13:30:00
15:00:00
SessionAmmonia-Based Aeration Control in Practice – Lessons Learned  
Session locationErnest N. Morial Convention Center
TopicFacility Operations and Maintenance, Municipal Wastewater Treatment Design
TopicFacility Operations and Maintenance, Municipal Wastewater Treatment Design
Author(s)
Rieger, Leiv, Schraa, Oliver
Author(s)L. Rieger1, O. Schraa1
Author affiliation(s)Jacobs Solutions Inc., 1Jacobs, 1
SourceProceedings of the Water Environment Federation
Document typeConference Paper
PublisherWater Environment Federation
Print publication date Sep 2026
DOI10.2175/193864718825160409
Volume / Issue
Content sourceWEFTEC
Copyright2026
Word count9

Actions, changes & tasks

Outstanding Actions

Add action for paragraph

Current Changes

Add signficant change

Current Tasks

Add risk task

Connect with us

Follow us on Facebook
Follow us on Twitter
Connect to us on LinkedIn
Subscribe on YouTube
Powered by Librios Ltd
Powered by Librios Ltd
Authors
Terms of Use
Policies
Help
Accessibility
Contact us
Copyright © 2026 by the Water Environment Federation
Loading items
There are no items to display at the moment.
Something went wrong trying to load these items.
Description: WWTF Digital Boot 180x150
WWTF Digital (180x150)
Created on Jul 02
Websitehttps:/­/­www.wef.org/­wwtf?utm_medium=WWTF&utm_source=AccessWater&utm_campaign=WWTF
180x150
Rieger, Leiv. Three Decades of Experience with Ammonia-Based Aeration Control. Water Environment Federation, 2026. Web. 25 Nov. 2026. <https://www.accesswater.org?id=-10128244CITANCHOR>.
Rieger, Leiv. Three Decades of Experience with Ammonia-Based Aeration Control. Water Environment Federation, 2026. Accessed November 25, 2026. https://www.accesswater.org/?id=-10128244CITANCHOR.
Rieger, Leiv
Three Decades of Experience with Ammonia-Based Aeration Control
Access Water
Water Environment Federation
September 29, 2026
November 25, 2026
https://www.accesswater.org/?id=-10128244CITANCHOR