Access Water | Practical Guidance for Biogas Leak Detection at Wastewater Facilities
lastID = -10128282
Skip to main content Skip to top navigation Skip to site search
Top of page
  • My citations options
    Web Back (from Web)
    Chicago Back (from Chicago)
    MLA Back (from MLA)
Close action menu

You need to login to use this feature.

Please wait a moment…
Please wait while we update your results...
Please wait a moment...
Loading icon
Description: Access Water
Context Menu
Description: Practical Guidance for Biogas Leak Detection at Wastewater Facilities
Practical Guidance for Biogas Leak Detection at Wastewater Facilities
  • Browse
  • Compilations
    • Compilations list
  • Subscriptions
Tools

Related contents

Loading related content

Workflow

No linked records yet

X
  • Current: 2026-09-25 14:56:42 Chris Lewis Continuous release
  • 2026-09-11 10:01:14 Adam Phillips
Description: Access Water
  • Browse
  • Compilations
  • Subscriptions
Log in
0
Accessibility Options

Base text size -

This is a sample piece of body text
Larger
Smaller
  • Shopping basket (0)
  • Accessibility options
  • Return to previous
Description: Practical Guidance for Biogas Leak Detection at Wastewater Facilities
Practical Guidance for Biogas Leak Detection at Wastewater Facilities

Practical Guidance for Biogas Leak Detection at Wastewater Facilities

Practical Guidance for Biogas Leak Detection at Wastewater Facilities

  • New
  • View
  • Details
  • Reader
  • Default
  • Share
  • Email
  • Facebook
  • Twitter
  • LinkedIn
  • New
  • View
  • Default view
  • Reader view
  • Data view
  • Details

This page cannot be printed from here

Please use the dedicated print option from the 'view' drop down menu located in the blue ribbon in the top, right section of the publication.

screenshot of print menu option

Description: Practical Guidance for Biogas Leak Detection at Wastewater Facilities
Practical Guidance for Biogas Leak Detection at Wastewater Facilities
Abstract
Anaerobic digesters and the biogas they produce have allowed wastewater resource recovery facilities (WRRFs) to transform into power plants. Through the refinement and collection of biogas, renewable natural gas (RNG) can be produced, which is able to be injected into local gas distribution grids or used on-site to offset grid natural gas usage. However, these advancements in waste-to-energy infrastructure provide new challenges for WRRFs. Just like any other type of pressurized gas system, these systems can leak. Biogas/RNG leaks are a direct loss of product, present a health and safety hazard for workers and additionally is a potent greenhouse gas. It is therefore important for plant managers to reduce or eliminate these leaks where possible. To assist in this challenge, the wastewater industry has begun to use tools established in the oil and gas industry, such as optical gas imaging cameras (OGI cameras) that use infrared radiation to visualize methane in air, and portable methane analyzers that use lasers to accurately measure across a range of methane concentrations (these tools are shown in Figure 1). Although these and many other types of methane measurement devices are being tested at wastewater facilities, what is missing is an overarching approach to how to appropriately conduct biogas leak surveys. This presentation will discuss a practical framework for conducting biogas leak finding campaigns at WRRFs as well as case studies utilizing this framework in the hopes of contributing towards our sector's eventual development of best practices. A framework was developed to assist WRRFs in creating effective and efficient leak detection programs following a plan-do-check-act structure for continuous improvement (Figure 1). In general, the planning stage should create a leak finding plan that considers the risk of equipment leaking biogas (age of equipment, leak history, pressure of system, etc.) as well as equipment prioritization. Some facilities may have hundreds to thousands of individual locations that could leak, and it is not typically practical to assess them all in detail, which is why prioritizing equipment/areas is vital. The next step is to do the leak finding study using appropriate tools such as OGI cameras and portable methane analyzers. Once the data is collected, a detailed review of the information must be conducted to compare actual leaks/equipment conditions to the original plan. Finally, observed leaks are actioned, which can include issuing work orders for maintenance repair, longer-term capital repair or improvement, or do nothing (i.e. the leak is too impractical to address, or system operates as designed e.g. methane-laden condensate from biogas drip traps). FIGURE 1: FRAMEWORK FOR CONTINUOUS IMPROVEMENT OF LEAK DETECTION City of Toronto Case Study The City of Toronto's Humber Treatment Plant undertook a fugitive methane leak finding survey following the described framework. Key locations determined in the initial risk assessment were a floating roof digester, pressure relief valves on digesters, digester roofs, gas compressor equipment, and biogas-mixing piping. An OGI camera and portable methane analyzer were selected as suitable tools for the evaluation (Figure 2). The OGI camera used in this study was a FLIR Gx320 (shown in use in Figure 3). The camera visualizes methane and other hydrocarbons such as butane and propane, as black/dark smoke on the device's display (Figure 4). The camera was particularly effective in complex environments, such as around biogas piping, where visual confirmation amidst dense equipment was critical. FIGURE 2: DEVICES USED FIGURE 3: OGI CAMERA IN USE FIGURE 4: OGI CAMERA OUTPUT EXAMPLE WITH METHANE INDICATION CIRCLED IN RED The other device used was a SEM5000, which uses Tunable Diode Laser Absorption Spectroscopy to quantify methane concentrations. The device recorded methane concentrations in parts per million (ppm) at one-second intervals, pairing each reading with time and location data via an integrated GPS module. Several types of information were developed from the observation data, including videos, a map of methane concentrations (Figure 5), and a list of leaks that could be resolved through maintenance activities. A key finding was that almost all biogas piping and gas compressor piping were in good condition, and only a few leaks required addressing. The City of Toronto is currently considering future leak detection assessments at a frequency to be informed by this study. FIGURE 5: VISUALIZED PORTABLE METHANE ANALYZER DATA
This paper was presented at WEFTEC 2026 in New Orleans, Louisiana.
Presentation time
08:30:00
09:00:00
Session time
8:30:00
10:00:00
SessionDecarbonizing Water: Fugitive Methane
Session locationErnest N. Morial Convention Center
TopicAir Quality and Odor Management, Biosolids and Residuals, Facility Operations and Maintenance
TopicAir Quality and Odor Management, Biosolids and Residuals, Facility Operations and Maintenance
Author(s)
Beelen, Benjamin, sabzwari, Aby, Joseph, Kevin, Kraemer, Jeremy, Szonda, Vanessa
Author(s)B. Beelen1, A. sabzwari1, K. Joseph1, J. Kraemer1, V. Szonda2
Author affiliation(s)GHD Group Pty Ltd., 1GHD Group Pty Ltd., 1GHD Group Pty Ltd., 1GHD Group Pty Ltd., 1City of Toronto, 2
SourceProceedings of the Water Environment Federation
Document typeConference Paper
PublisherWater Environment Federation
Print publication date Sep 2026
DOI10.2175/193864718825160447
Volume / Issue
Content sourceWEFTEC
Copyright2026
Word count10

Purchase price $11.50

Get access
Log in Purchase content Purchase subscription
You may already have access to this content if you have previously purchased this content or have a subscription.
Need to create an account?

You can purchase access to this content but you might want to consider a subscription for a wide variety of items at a substantial discount!

Purchase access to 'Practical Guidance for Biogas Leak Detection at Wastewater Facilities'

Add to cart
Purchase a subscription to gain access to 18,000+ Proceeding Papers, 25+ Fact Sheets, 20+ Technical Reports, 50+ magazine articles and select Technical Publications' chapters.
Loading items
There are no items to display at the moment.
Something went wrong trying to load these items.
Description: Practical Guidance for Biogas Leak Detection at Wastewater Facilities
Practical Guidance for Biogas Leak Detection at Wastewater Facilities
Pricing
Non-member price: $11.50
Member price:
-10128282
Get access
-10128282
Log in Purchase content Purchase subscription
You may already have access to this content if you have previously purchased this content or have a subscription.
Need to create an account?

You can purchase access to this content but you might want to consider a subscription for a wide variety of items at a substantial discount!

Purchase access to 'Practical Guidance for Biogas Leak Detection at Wastewater Facilities'

Add to cart
Purchase a subscription to gain access to 18,000+ Proceeding Papers, 25+ Fact Sheets, 20+ Technical Reports, 50+ magazine articles and select Technical Publications' chapters.

Details

Description: Practical Guidance for Biogas Leak Detection at Wastewater Facilities
Practical Guidance for Biogas Leak Detection at Wastewater Facilities
Abstract
Anaerobic digesters and the biogas they produce have allowed wastewater resource recovery facilities (WRRFs) to transform into power plants. Through the refinement and collection of biogas, renewable natural gas (RNG) can be produced, which is able to be injected into local gas distribution grids or used on-site to offset grid natural gas usage. However, these advancements in waste-to-energy infrastructure provide new challenges for WRRFs. Just like any other type of pressurized gas system, these systems can leak. Biogas/RNG leaks are a direct loss of product, present a health and safety hazard for workers and additionally is a potent greenhouse gas. It is therefore important for plant managers to reduce or eliminate these leaks where possible. To assist in this challenge, the wastewater industry has begun to use tools established in the oil and gas industry, such as optical gas imaging cameras (OGI cameras) that use infrared radiation to visualize methane in air, and portable methane analyzers that use lasers to accurately measure across a range of methane concentrations (these tools are shown in Figure 1). Although these and many other types of methane measurement devices are being tested at wastewater facilities, what is missing is an overarching approach to how to appropriately conduct biogas leak surveys. This presentation will discuss a practical framework for conducting biogas leak finding campaigns at WRRFs as well as case studies utilizing this framework in the hopes of contributing towards our sector's eventual development of best practices. A framework was developed to assist WRRFs in creating effective and efficient leak detection programs following a plan-do-check-act structure for continuous improvement (Figure 1). In general, the planning stage should create a leak finding plan that considers the risk of equipment leaking biogas (age of equipment, leak history, pressure of system, etc.) as well as equipment prioritization. Some facilities may have hundreds to thousands of individual locations that could leak, and it is not typically practical to assess them all in detail, which is why prioritizing equipment/areas is vital. The next step is to do the leak finding study using appropriate tools such as OGI cameras and portable methane analyzers. Once the data is collected, a detailed review of the information must be conducted to compare actual leaks/equipment conditions to the original plan. Finally, observed leaks are actioned, which can include issuing work orders for maintenance repair, longer-term capital repair or improvement, or do nothing (i.e. the leak is too impractical to address, or system operates as designed e.g. methane-laden condensate from biogas drip traps). FIGURE 1: FRAMEWORK FOR CONTINUOUS IMPROVEMENT OF LEAK DETECTION City of Toronto Case Study The City of Toronto's Humber Treatment Plant undertook a fugitive methane leak finding survey following the described framework. Key locations determined in the initial risk assessment were a floating roof digester, pressure relief valves on digesters, digester roofs, gas compressor equipment, and biogas-mixing piping. An OGI camera and portable methane analyzer were selected as suitable tools for the evaluation (Figure 2). The OGI camera used in this study was a FLIR Gx320 (shown in use in Figure 3). The camera visualizes methane and other hydrocarbons such as butane and propane, as black/dark smoke on the device's display (Figure 4). The camera was particularly effective in complex environments, such as around biogas piping, where visual confirmation amidst dense equipment was critical. FIGURE 2: DEVICES USED FIGURE 3: OGI CAMERA IN USE FIGURE 4: OGI CAMERA OUTPUT EXAMPLE WITH METHANE INDICATION CIRCLED IN RED The other device used was a SEM5000, which uses Tunable Diode Laser Absorption Spectroscopy to quantify methane concentrations. The device recorded methane concentrations in parts per million (ppm) at one-second intervals, pairing each reading with time and location data via an integrated GPS module. Several types of information were developed from the observation data, including videos, a map of methane concentrations (Figure 5), and a list of leaks that could be resolved through maintenance activities. A key finding was that almost all biogas piping and gas compressor piping were in good condition, and only a few leaks required addressing. The City of Toronto is currently considering future leak detection assessments at a frequency to be informed by this study. FIGURE 5: VISUALIZED PORTABLE METHANE ANALYZER DATA
This paper was presented at WEFTEC 2026 in New Orleans, Louisiana.
Presentation time
08:30:00
09:00:00
Session time
8:30:00
10:00:00
SessionDecarbonizing Water: Fugitive Methane
Session locationErnest N. Morial Convention Center
TopicAir Quality and Odor Management, Biosolids and Residuals, Facility Operations and Maintenance
TopicAir Quality and Odor Management, Biosolids and Residuals, Facility Operations and Maintenance
Author(s)
Beelen, Benjamin, sabzwari, Aby, Joseph, Kevin, Kraemer, Jeremy, Szonda, Vanessa
Author(s)B. Beelen1, A. sabzwari1, K. Joseph1, J. Kraemer1, V. Szonda2
Author affiliation(s)GHD Group Pty Ltd., 1GHD Group Pty Ltd., 1GHD Group Pty Ltd., 1GHD Group Pty Ltd., 1City of Toronto, 2
SourceProceedings of the Water Environment Federation
Document typeConference Paper
PublisherWater Environment Federation
Print publication date Sep 2026
DOI10.2175/193864718825160447
Volume / Issue
Content sourceWEFTEC
Copyright2026
Word count10

Actions, changes & tasks

Outstanding Actions

Add action for paragraph

Current Changes

Add signficant change

Current Tasks

Add risk task

Connect with us

Follow us on Facebook
Follow us on Twitter
Connect to us on LinkedIn
Subscribe on YouTube
Powered by Librios Ltd
Powered by Librios Ltd
Authors
Terms of Use
Policies
Help
Accessibility
Contact us
Copyright © 2026 by the Water Environment Federation
Loading items
There are no items to display at the moment.
Something went wrong trying to load these items.
Description: WWTF Digital Boot 180x150
WWTF Digital (180x150)
Created on Jul 02
Websitehttps:/­/­www.wef.org/­wwtf?utm_medium=WWTF&utm_source=AccessWater&utm_campaign=WWTF
180x150
Beelen, Benjamin. Practical Guidance for Biogas Leak Detection at Wastewater Facilities. Water Environment Federation, 2026. Web. 10 Nov. 2026. <https://www.accesswater.org?id=-10128282CITANCHOR>.
Beelen, Benjamin. Practical Guidance for Biogas Leak Detection at Wastewater Facilities. Water Environment Federation, 2026. Accessed November 10, 2026. https://www.accesswater.org/?id=-10128282CITANCHOR.
Beelen, Benjamin
Practical Guidance for Biogas Leak Detection at Wastewater Facilities
Access Water
Water Environment Federation
September 30, 2026
November 10, 2026
https://www.accesswater.org/?id=-10128282CITANCHOR