lastID = -280829
Skip to main content Skip to top navigation Skip to site search
Top of page
  • My citations options
    Web Back (from Web)
    Chicago Back (from Chicago)
    MLA Back (from MLA)
Close action menu

You need to login to use this feature.

Please wait a moment…
Please wait while we update your results...
Please wait a moment...
Description: Access Water
Context Menu
Description: Control of Odor Emissions from a CSO Storage Tunnel in Providence, R.I.
Control of Odor Emissions from a CSO Storage Tunnel in Providence, R.I.
  • Browse
  • Compilations
    • Compilations list
  • Subscriptions
Tools

Related contents

Loading related content

Workflow

No linked records yet

X
  • Current: 2022-06-14 20:25:51 Adam Phillips
  • 2022-06-14 20:25:50 Adam Phillips
  • 2020-03-30 23:14:56 Adam Phillips
  • 2020-03-30 23:14:55 Adam Phillips
  • 2020-03-30 20:46:20 Adam Phillips
  • 2020-03-30 20:46:19 Adam Phillips
  • 2020-03-27 16:02:09 Katherine Saltzman
  • 2020-03-27 16:02:08 Katherine Saltzman
  • 2020-03-27 00:11:20 Adam Phillips
  • 2020-01-31 21:25:50 Administrator
  • 2020-01-31 21:25:49 Administrator
Description: Access Water
  • Browse
  • Compilations
  • Subscriptions
Log in
0
Accessibility Options

Base text size -

This is a sample piece of body text
Larger
Smaller
  • Shopping basket (0)
  • Accessibility options
  • Return to previous
Description: Control of Odor Emissions from a CSO Storage Tunnel in Providence, R.I.
Control of Odor Emissions from a CSO Storage Tunnel in Providence, R.I.

Control of Odor Emissions from a CSO Storage Tunnel in Providence, R.I.

Control of Odor Emissions from a CSO Storage Tunnel in Providence, R.I.

  • New
  • View
  • Details
  • Reader
  • Default
  • Share
  • Email
  • Facebook
  • Twitter
  • LinkedIn
  • New
  • View
  • Default view
  • Reader view
  • Data view
  • Details

This page cannot be printed from here

Please use the dedicated print option from the 'view' drop down menu located in the blue ribbon in the top, right section of the publication.

screenshot of print menu option

Description: Control of Odor Emissions from a CSO Storage Tunnel in Providence, R.I.
Control of Odor Emissions from a CSO Storage Tunnel in Providence, R.I.
Abstract
The Narragansett Bay Commission operates a large combined sewer overflow (CSO) storage facility in Providence, RI. The facility consists of a 26-ft diameter, 16,250-ft long tunnel having a wastewater storage capacity of over 65 million gallons. The system includes seven drop shafts and two 26-ft diameter ventilation shafts at the upstream end (Foundry Shaft) and at the downstream end, where there is a pumping station. When the facility came on-line in late 2008, odor complaints were received from residents living near the upper Foundry Shaft.Observations and data collected by Narragansett Bay Commission and Louis Berger Group showed the emissions to be worst during cold ambient temperatures due to natural convection, and during CSO tunnel filling events that displaced the odorous air. Air flow measurements during the winter indicated natural ventilation rates from the Foundry vent shaft up to 50,000 cfm with the potential to approach 100,000 cfm. The air was mildly odorous, with a musty sewage character and low hydrogen sulfide levels of 0 to 50 ppb, with spikes up to 150 ppb.Bowker & Associates was retained to evaluate control strategies to treat this air. Pressure monitoring was conducted to better understand the air flow dynamics in the tunnel ventilation shafts, but the results were inconclusive. Both biofilters and activated carbon adsorbers were evaluated. Due to the high air flow rates, the space requirements for the biofilter were prohibitive. Two 30,000 cfm radial flow activated carbon adsorbers were recommended, which would provide sufficient capacity to treat the vast majority of the air during worst-case conditions. The fans were to be equipped with VFD's to achieve maximum flexibility and minimize power consumption. The proposed carbon media was a lignite-based, high H2S-capacity media with a high tolerance for moisture that was expected in the humid air stream. The conceptual design included grease/mist eliminators upstream of each fan.A request for proposals was prepared for a design-build project and in September of 2009, a contract was awarded to the team of Hart Construction and Wright-Pierce Engineers. Construction began in March, 2010, and was completed in in the fall of 2010.The system has achieved its objectives in controlling odors from the CSO storage tunnel. Performance testing showed H2S and odor reductions of 99 percent, and odor complaints have been nearly eliminated. On some occasions in the winter, the natural ventilation rate of the tunnel exceeds the 60,000 cfm capacity of the carbon systems, and “fugitive odors” can be detected near the vent shaft. However, even in such cases, the volume of untreated odorous air being discharged is reduced by at least 80 percent, minimizing impacts on the community. Activated carbon adsorption is an excellent choice for the control of odors from CSO storage facilities that typically have low odor loadings and intermittent use.
The Narragansett Bay Commission operates a large combined sewer overflow (CSO) storage facility in Providence, RI. The facility consists of a 26-ft diameter, 16,250-ft long tunnel having a wastewater storage capacity of over 65 million gallons. The system includes seven drop shafts and two 26-ft diameter ventilation shafts at the upstream end (Foundry Shaft) and at the downstream end, where there...
Author(s)
Robert P. G. BowkerPhilip H. AlbertAnthony DalmazziJoseph PrattDavid C. Bowen
SourceProceedings of the Water Environment Federation
Document typeConference Paper
PublisherWater Environment Federation
Print publication date Apr, 2012
ISSN1938-6478
DOI10.2175/193864712811700228
Volume / Issue2012 / 3
Content sourceOdors and Air Pollutants Conference
Copyright2012
Word count474

Purchase price $11.50

Get access
Log in Purchase content Purchase subscription
You may already have access to this content if you have previously purchased this content or have a subscription.
Need to create an account?

You can purchase access to this content but you might want to consider a subscription for a wide variety of items at a substantial discount!

Purchase access to 'Control of Odor Emissions from a CSO Storage Tunnel in Providence, R.I.'

Add to cart
Purchase a subscription to gain access to 18,000+ Proceeding Papers, 25+ Fact Sheets, 20+ Technical Reports, 50+ magazine articles and select Technical Publications' chapters.
Loading items
There are no items to display at the moment.
Something went wrong trying to load these items.
Description: Control of Odor Emissions from a CSO Storage Tunnel in Providence, R.I.
Control of Odor Emissions from a CSO Storage Tunnel in Providence, R.I.
Pricing
Non-member price: $11.50
Member price:
-280829
Get access
-280829
Log in Purchase content Purchase subscription
You may already have access to this content if you have previously purchased this content or have a subscription.
Need to create an account?

You can purchase access to this content but you might want to consider a subscription for a wide variety of items at a substantial discount!

Purchase access to 'Control of Odor Emissions from a CSO Storage Tunnel in Providence, R.I.'

Add to cart
Purchase a subscription to gain access to 18,000+ Proceeding Papers, 25+ Fact Sheets, 20+ Technical Reports, 50+ magazine articles and select Technical Publications' chapters.

Details

Description: Control of Odor Emissions from a CSO Storage Tunnel in Providence, R.I.
Control of Odor Emissions from a CSO Storage Tunnel in Providence, R.I.
Abstract
The Narragansett Bay Commission operates a large combined sewer overflow (CSO) storage facility in Providence, RI. The facility consists of a 26-ft diameter, 16,250-ft long tunnel having a wastewater storage capacity of over 65 million gallons. The system includes seven drop shafts and two 26-ft diameter ventilation shafts at the upstream end (Foundry Shaft) and at the downstream end, where there is a pumping station. When the facility came on-line in late 2008, odor complaints were received from residents living near the upper Foundry Shaft.Observations and data collected by Narragansett Bay Commission and Louis Berger Group showed the emissions to be worst during cold ambient temperatures due to natural convection, and during CSO tunnel filling events that displaced the odorous air. Air flow measurements during the winter indicated natural ventilation rates from the Foundry vent shaft up to 50,000 cfm with the potential to approach 100,000 cfm. The air was mildly odorous, with a musty sewage character and low hydrogen sulfide levels of 0 to 50 ppb, with spikes up to 150 ppb.Bowker & Associates was retained to evaluate control strategies to treat this air. Pressure monitoring was conducted to better understand the air flow dynamics in the tunnel ventilation shafts, but the results were inconclusive. Both biofilters and activated carbon adsorbers were evaluated. Due to the high air flow rates, the space requirements for the biofilter were prohibitive. Two 30,000 cfm radial flow activated carbon adsorbers were recommended, which would provide sufficient capacity to treat the vast majority of the air during worst-case conditions. The fans were to be equipped with VFD's to achieve maximum flexibility and minimize power consumption. The proposed carbon media was a lignite-based, high H2S-capacity media with a high tolerance for moisture that was expected in the humid air stream. The conceptual design included grease/mist eliminators upstream of each fan.A request for proposals was prepared for a design-build project and in September of 2009, a contract was awarded to the team of Hart Construction and Wright-Pierce Engineers. Construction began in March, 2010, and was completed in in the fall of 2010.The system has achieved its objectives in controlling odors from the CSO storage tunnel. Performance testing showed H2S and odor reductions of 99 percent, and odor complaints have been nearly eliminated. On some occasions in the winter, the natural ventilation rate of the tunnel exceeds the 60,000 cfm capacity of the carbon systems, and “fugitive odors” can be detected near the vent shaft. However, even in such cases, the volume of untreated odorous air being discharged is reduced by at least 80 percent, minimizing impacts on the community. Activated carbon adsorption is an excellent choice for the control of odors from CSO storage facilities that typically have low odor loadings and intermittent use.
The Narragansett Bay Commission operates a large combined sewer overflow (CSO) storage facility in Providence, RI. The facility consists of a 26-ft diameter, 16,250-ft long tunnel having a wastewater storage capacity of over 65 million gallons. The system includes seven drop shafts and two 26-ft diameter ventilation shafts at the upstream end (Foundry Shaft) and at the downstream end, where there...
Author(s)
Robert P. G. BowkerPhilip H. AlbertAnthony DalmazziJoseph PrattDavid C. Bowen
SourceProceedings of the Water Environment Federation
Document typeConference Paper
PublisherWater Environment Federation
Print publication date Apr, 2012
ISSN1938-6478
DOI10.2175/193864712811700228
Volume / Issue2012 / 3
Content sourceOdors and Air Pollutants Conference
Copyright2012
Word count474

Actions, changes & tasks

Outstanding Actions

Add action for paragraph

Current Changes

Add signficant change

Current Tasks

Add risk task

Connect with us

Follow us on Facebook
Follow us on Twitter
Connect to us on LinkedIn
Subscribe on YouTube
Powered by Librios Ltd
Powered by Librios Ltd
Authors
Terms of Use
Policies
Help
Accessibility
Contact us
Copyright © 2024 by the Water Environment Federation
Loading items
There are no items to display at the moment.
Something went wrong trying to load these items.
Description: WWTF Digital Boot 180x150
WWTF Digital (180x150)
Created on Jul 02
Websitehttps:/­/­www.wef.org/­wwtf?utm_medium=WWTF&utm_source=AccessWater&utm_campaign=WWTF
180x150
Robert P. G. Bowker# Philip H. Albert# Anthony Dalmazzi# Joseph Pratt# David C. Bowen. Control of Odor Emissions from a CSO Storage Tunnel in Providence, R.I. Alexandria, VA 22314-1994, USA: Water Environment Federation, 2018. Web. 7 Jun. 2025. <https://www.accesswater.org?id=-280829CITANCHOR>.
Robert P. G. Bowker# Philip H. Albert# Anthony Dalmazzi# Joseph Pratt# David C. Bowen. Control of Odor Emissions from a CSO Storage Tunnel in Providence, R.I. Alexandria, VA 22314-1994, USA: Water Environment Federation, 2018. Accessed June 7, 2025. https://www.accesswater.org/?id=-280829CITANCHOR.
Robert P. G. Bowker# Philip H. Albert# Anthony Dalmazzi# Joseph Pratt# David C. Bowen
Control of Odor Emissions from a CSO Storage Tunnel in Providence, R.I.
Access Water
Water Environment Federation
December 22, 2018
June 7, 2025
https://www.accesswater.org/?id=-280829CITANCHOR