lastID = -290653
Skip to main content Skip to top navigation Skip to site search
Top of page
  • My citations options
    Web Back (from Web)
    Chicago Back (from Chicago)
    MLA Back (from MLA)
Close action menu

You need to login to use this feature.

Please wait a moment…
Please wait while we update your results...
Please wait a moment...
Description: Access Water
Context Menu
Description: Book cover
New Surface Aerators Reduced Yuba City's Oxygen Dissolution Power Draw by 33%
  • Browse
  • Compilations
    • Compilations list
  • Subscriptions
Tools

Related contents

Loading related content

Workflow

No linked records yet

X
  • Current: 2020-02-01 01:56:30 Administrator
  • 2020-02-01 01:56:29 Administrator
Description: Access Water
  • Browse
  • Compilations
  • Subscriptions
Log in
0
Accessibility Options

Base text size -

This is a sample piece of body text
Larger
Smaller
  • Shopping basket (0)
  • Accessibility options
  • Return to previous
Description: Book cover
New Surface Aerators Reduced Yuba City's Oxygen Dissolution Power Draw by 33%

New Surface Aerators Reduced Yuba City's Oxygen Dissolution Power Draw by 33%

New Surface Aerators Reduced Yuba City's Oxygen Dissolution Power Draw by 33%

  • New
  • View
  • Details
  • Reader
  • Default
  • Share
  • Email
  • Facebook
  • Twitter
  • LinkedIn
  • New
  • View
  • Default view
  • Reader view
  • Data view
  • Details

This page cannot be printed from here

Please use the dedicated print option from the 'view' drop down menu located in the blue ribbon in the top, right section of the publication.

screenshot of print menu option

Description: Book cover
New Surface Aerators Reduced Yuba City's Oxygen Dissolution Power Draw by 33%
Abstract
The secondary treatment system at the Yuba City, California Wastewater Treatment Facility is a high purity oxygen UNOX System. Yuba City was the first high purity oxygen wastewater facility in California. The system consists of 3 aeration trains, each train containing 4 stages. Each stage is equipped with a surface aerator. Oxygen is supplied from a single 21 ton per day (TPD) pressure swing adsorption (PSA) oxygen generator.Current dry weather influent flows average 6.0 mgd. During the summer, when power costs and demand charges are high, the temperature of the influent wastewater increases to approximately 29.4°C The only reliable way to handle the mass transfer requirements at these elevated temperatures has been to operate two UNOX System trains, even though hydraulically one train would be sufficient.In early 2002, Yuba City had fabricated 4 new high efficiency surface aerator turbines under a special demonstration program agreement with the turbine's manufacturer. These turbines were then tested in the WTF's tanks using ASCE standard tap water test procedures. The testing indicated that these turbines, called the HI-FLO Surface Aeration System, had approximately 17% higher mass transfer efficiencies than the units that were originally installed in the WTF.When retrofit on the WTF's existing, 25 year old gearboxes and shafts, the more efficient turbines increased the oxygen dissolution capacity of this equipment sufficiently so that single train operation was possible during the summer of 2002. Once installed, the new aeration system reduced oxygen dissolution power consumption by 33%, from 205 Hp. to 137 Hp. with no detrimental effects on biological performance. Similar savings may be available to wastewater facilities that have hydraulic capacity, but require increased oxygen dissolution capability.
The secondary treatment system at the Yuba City, California Wastewater Treatment Facility is a high purity oxygen UNOX System. Yuba City was the first high purity oxygen wastewater facility in California. The system consists of 3 aeration trains, each train containing 4 stages. Each stage is equipped with a surface aerator. Oxygen is supplied from a single 21 ton per day (TPD) pressure swing...
Author(s)
William P. LewisDaniel W. Gay
SourceProceedings of the Water Environment Federation
SubjectSession 37 Plant Operations and Maintenance and Lab Practices: Power and Energy Efficiency
Document typeConference Paper
PublisherWater Environment Federation
Print publication date Jan, 2003
ISSN1938-6478
SICI1938-6478(20030101)2003:9L.392;1-
DOI10.2175/193864703784639642
Volume / Issue2003 / 9
Content sourceWEFTEC
First / last page(s)392 - 401
Copyright2003
Word count286

Purchase price $11.50

Get access
Log in Purchase content Purchase subscription
You may already have access to this content if you have previously purchased this content or have a subscription.
Need to create an account?

You can purchase access to this content but you might want to consider a subscription for a wide variety of items at a substantial discount!

Purchase access to 'New Surface Aerators Reduced Yuba City's Oxygen Dissolution Power Draw by 33%'

Add to cart
Purchase a subscription to gain access to 18,000+ Proceeding Papers, 25+ Fact Sheets, 20+ Technical Reports, 50+ magazine articles and select Technical Publications' chapters.
Loading items
There are no items to display at the moment.
Something went wrong trying to load these items.
Description: Book cover
New Surface Aerators Reduced Yuba City's Oxygen Dissolution Power Draw by 33%
Pricing
Non-member price: $11.50
Member price:
-290653
Get access
-290653
Log in Purchase content Purchase subscription
You may already have access to this content if you have previously purchased this content or have a subscription.
Need to create an account?

You can purchase access to this content but you might want to consider a subscription for a wide variety of items at a substantial discount!

Purchase access to 'New Surface Aerators Reduced Yuba City's Oxygen Dissolution Power Draw by 33%'

Add to cart
Purchase a subscription to gain access to 18,000+ Proceeding Papers, 25+ Fact Sheets, 20+ Technical Reports, 50+ magazine articles and select Technical Publications' chapters.

Details

Description: Book cover
New Surface Aerators Reduced Yuba City's Oxygen Dissolution Power Draw by 33%
Abstract
The secondary treatment system at the Yuba City, California Wastewater Treatment Facility is a high purity oxygen UNOX System. Yuba City was the first high purity oxygen wastewater facility in California. The system consists of 3 aeration trains, each train containing 4 stages. Each stage is equipped with a surface aerator. Oxygen is supplied from a single 21 ton per day (TPD) pressure swing adsorption (PSA) oxygen generator.Current dry weather influent flows average 6.0 mgd. During the summer, when power costs and demand charges are high, the temperature of the influent wastewater increases to approximately 29.4°C The only reliable way to handle the mass transfer requirements at these elevated temperatures has been to operate two UNOX System trains, even though hydraulically one train would be sufficient.In early 2002, Yuba City had fabricated 4 new high efficiency surface aerator turbines under a special demonstration program agreement with the turbine's manufacturer. These turbines were then tested in the WTF's tanks using ASCE standard tap water test procedures. The testing indicated that these turbines, called the HI-FLO Surface Aeration System, had approximately 17% higher mass transfer efficiencies than the units that were originally installed in the WTF.When retrofit on the WTF's existing, 25 year old gearboxes and shafts, the more efficient turbines increased the oxygen dissolution capacity of this equipment sufficiently so that single train operation was possible during the summer of 2002. Once installed, the new aeration system reduced oxygen dissolution power consumption by 33%, from 205 Hp. to 137 Hp. with no detrimental effects on biological performance. Similar savings may be available to wastewater facilities that have hydraulic capacity, but require increased oxygen dissolution capability.
The secondary treatment system at the Yuba City, California Wastewater Treatment Facility is a high purity oxygen UNOX System. Yuba City was the first high purity oxygen wastewater facility in California. The system consists of 3 aeration trains, each train containing 4 stages. Each stage is equipped with a surface aerator. Oxygen is supplied from a single 21 ton per day (TPD) pressure swing...
Author(s)
William P. LewisDaniel W. Gay
SourceProceedings of the Water Environment Federation
SubjectSession 37 Plant Operations and Maintenance and Lab Practices: Power and Energy Efficiency
Document typeConference Paper
PublisherWater Environment Federation
Print publication date Jan, 2003
ISSN1938-6478
SICI1938-6478(20030101)2003:9L.392;1-
DOI10.2175/193864703784639642
Volume / Issue2003 / 9
Content sourceWEFTEC
First / last page(s)392 - 401
Copyright2003
Word count286

Actions, changes & tasks

Outstanding Actions

Add action for paragraph

Current Changes

Add signficant change

Current Tasks

Add risk task

Connect with us

Follow us on Facebook
Follow us on Twitter
Connect to us on LinkedIn
Subscribe on YouTube
Powered by Librios Ltd
Powered by Librios Ltd
Authors
Terms of Use
Policies
Help
Accessibility
Contact us
Copyright © 2024 by the Water Environment Federation
Loading items
There are no items to display at the moment.
Something went wrong trying to load these items.
Description: WWTF Digital Boot 180x150
WWTF Digital (180x150)
Created on Jul 02
Websitehttps:/­/­www.wef.org/­wwtf?utm_medium=WWTF&utm_source=AccessWater&utm_campaign=WWTF
180x150
William P. Lewis# Daniel W. Gay. New Surface Aerators Reduced Yuba City's Oxygen Dissolution Power Draw by 33%. Alexandria, VA 22314-1994, USA: Water Environment Federation, 2018. Web. 29 Jun. 2025. <https://www.accesswater.org?id=-290653CITANCHOR>.
William P. Lewis# Daniel W. Gay. New Surface Aerators Reduced Yuba City's Oxygen Dissolution Power Draw by 33%. Alexandria, VA 22314-1994, USA: Water Environment Federation, 2018. Accessed June 29, 2025. https://www.accesswater.org/?id=-290653CITANCHOR.
William P. Lewis# Daniel W. Gay
New Surface Aerators Reduced Yuba City's Oxygen Dissolution Power Draw by 33%
Access Water
Water Environment Federation
December 22, 2018
June 29, 2025
https://www.accesswater.org/?id=-290653CITANCHOR