lastID = -290853
Skip to main content Skip to top navigation Skip to site search
Top of page
  • My citations options
    Web Back (from Web)
    Chicago Back (from Chicago)
    MLA Back (from MLA)
Close action menu

You need to login to use this feature.

Please wait a moment…
Please wait while we update your results...
Please wait a moment...
Description: Access Water
Context Menu
Description: Book cover
ODOR MODELING: CASE STUDY SHOWS COST SAVINGS AND FIELD VERIFIED RESULTS
  • Browse
  • Compilations
    • Compilations list
  • Subscriptions
Tools

Related contents

Loading related content

Workflow

No linked records yet

X
  • Current: 2022-05-06 11:17:19 Adam Phillips
  • 2022-05-06 11:17:18 Adam Phillips
  • 2020-02-01 02:17:33 Administrator
  • 2020-02-01 02:17:32 Administrator
Description: Access Water
  • Browse
  • Compilations
  • Subscriptions
Log in
0
Accessibility Options

Base text size -

This is a sample piece of body text
Larger
Smaller
  • Shopping basket (0)
  • Accessibility options
  • Return to previous
Description: Book cover
ODOR MODELING: CASE STUDY SHOWS COST SAVINGS AND FIELD VERIFIED RESULTS

ODOR MODELING: CASE STUDY SHOWS COST SAVINGS AND FIELD VERIFIED RESULTS

ODOR MODELING: CASE STUDY SHOWS COST SAVINGS AND FIELD VERIFIED RESULTS

  • New
  • View
  • Details
  • Reader
  • Default
  • Share
  • Email
  • Facebook
  • Twitter
  • LinkedIn
  • New
  • View
  • Default view
  • Reader view
  • Data view
  • Details

This page cannot be printed from here

Please use the dedicated print option from the 'view' drop down menu located in the blue ribbon in the top, right section of the publication.

screenshot of print menu option

Description: Book cover
ODOR MODELING: CASE STUDY SHOWS COST SAVINGS AND FIELD VERIFIED RESULTS
Abstract
Project Overview In response to odor complaints received from residents near the 19.5 million gallon per day (MGD) West County Wastewater Treatment Plant (WCWTP), the Louisville and Jefferson County Metropolitan Sewer District (MSD) initiated a program to cost effectively control odors at this plant. The program included air dispersion modeling to predict the impacts of potential odor control improvements, and an extensive community participation program to involve the affected residents in the problem identification, model evaluation, and selection of the control approach. Using air dispersion models calibrated by field observations, MSD identified a 2- phased approach to resolving odor issues. Field verification after completion of the first phase of improvements validated the model predictions, confirming that off-site odors were virtually eliminated with the Phase 1 improvements. This phased approach was successful in resolving community concerns regarding off-site odors and saved MSD nearly 4 million in the process, by eliminating the need for the second phase of improvements. This project is unique in its use of air dispersion modeling to select the odor control system and to verify the results afterwards with performance testing and community odor surveys. Goals and Objectives The goals established for the project were based on MSD's Facilities Buffer Zone Policy, which requires MSD to evaluate reasonable technical approaches to minimize detrimental off-site impacts of their facilities. The specific objectives of this project were to identify all the odor sources and to select the minimum-cost odor control systems that could reliably eliminate offensive off-site odors. To help ensure community acceptance, the project also included extensive public participation in the process, particularly in the area of identifying the problem through community odor surveys and plant tours. Identifying the Problem A comprehensive sampling and testing program was conducted to determine odor emission rates for the plant. In addition, community odor surveys (with residents' participation) were conducted to record odor character, to measure intensity and to identify the source of the odor. Odor testing revealed that the influent screen building (80%) and the activated sludge process (10%) were the highest sources of odor emissions from the plant site. The original intent, therefore, was to cover all the aeration tanks and treat all the air from the plant processes, at a cost of about 6 million. It was then decided to perform atmospheric dispersion odor modeling to predict the downwind odor concentrations measured in dilutions-to-threshold (D/T) from controlled and uncontrolled odor sources. The investigation of the alternative odor control strategies also included an examination of the frequency of any odor concentration greater than the established odor detection threshold DT of 7. Contour plots were prepared to view the number of times during the year the odors are above the 7 DT for short time periods. The Solution A modified 2-phased plan was prepared for odor control, which included covering the aerated influent channels to the activated sludge process and treating this air in a modular synthetic media biofilter and converting the aeration basins to fine bubble diffusers (which was already in the budget for energy saving reasons). The influent channels were found to be the most likely source of activated sludge odors detected off-site due to the mixing of raw sewage and return activated sludge. Other improvements included the installation of a 14,000 cfm carbon adsorber for the influent screen room, covers on the grit tanks and use of activated sludge diffusion to treat the collected air. The modeling results showed that with this modified plan the closest neighbors might occasionally notice a faint odor (between 7 and 24 DT), as compared to previous conditions when the model predicted as many as 500 occurrences per year with DT's as high as 80. On this basis, MSD decided to pursue this phased approach and test the odor control systems and conduct additional community surveys after the first phase was completed to see if the odor control systems then in-place were sufficient or if further odor control was required. The Benefits All the odor control systems were tested after start-up and the results showed an 87% reduction in overall odor emissions from the plant and a 97% reduction in hydrogen sulfide emissions. Treatment plant odors were never detected in the community surveys conducted following the odor control system startup and residents commented that they no longer detected the odor from the plant. The paper presents the odor levels tested prior to odor control, the odor levels assumed for the modeling and the odor levels actually tested in the performance testing of the equipment. The project clearly demonstrates the value of odor testing and modeling and the importance of follow up testing and monitoring to verify that the investment resulted in effective odor control. In this case, MSD saved 4 million and developed community acceptance with this approach.
Project Overview In response to odor complaints received from residents near the 19.5 million gallon per day (MGD) West County Wastewater Treatment Plant (WCWTP), the Louisville and Jefferson County Metropolitan Sewer District (MSD) initiated a program to cost effectively control odors at this plant. The program included air dispersion modeling to predict the impacts of potential odor control...
Author(s)
N. WebsterS. WorleyG. SwansonA. HoggeW. Desing
SourceProceedings of the Water Environment Federation
SubjectSession 34: Biotechnology for Controlling Odor and VOCs
Document typeConference Paper
PublisherWater Environment Federation
Print publication date Jan, 2004
ISSN1938-6478
SICI1938-6478(20040101)2004:13L.231;1-
DOI10.2175/193864704784138043
Volume / Issue2004 / 13
Content sourceWEFTEC
First / last page(s)231 - 241
Copyright2004
Word count807

Purchase price $11.50

Get access
Log in Purchase content Purchase subscription
You may already have access to this content if you have previously purchased this content or have a subscription.
Need to create an account?

You can purchase access to this content but you might want to consider a subscription for a wide variety of items at a substantial discount!

Purchase access to 'ODOR MODELING: CASE STUDY SHOWS COST SAVINGS AND FIELD VERIFIED RESULTS'

Add to cart
Purchase a subscription to gain access to 18,000+ Proceeding Papers, 25+ Fact Sheets, 20+ Technical Reports, 50+ magazine articles and select Technical Publications' chapters.
Loading items
There are no items to display at the moment.
Something went wrong trying to load these items.
Description: Book cover
ODOR MODELING: CASE STUDY SHOWS COST SAVINGS AND FIELD VERIFIED RESULTS
Pricing
Non-member price: $11.50
Member price:
-290853
Get access
-290853
Log in Purchase content Purchase subscription
You may already have access to this content if you have previously purchased this content or have a subscription.
Need to create an account?

You can purchase access to this content but you might want to consider a subscription for a wide variety of items at a substantial discount!

Purchase access to 'ODOR MODELING: CASE STUDY SHOWS COST SAVINGS AND FIELD VERIFIED RESULTS'

Add to cart
Purchase a subscription to gain access to 18,000+ Proceeding Papers, 25+ Fact Sheets, 20+ Technical Reports, 50+ magazine articles and select Technical Publications' chapters.

Details

Description: Book cover
ODOR MODELING: CASE STUDY SHOWS COST SAVINGS AND FIELD VERIFIED RESULTS
Abstract
Project Overview In response to odor complaints received from residents near the 19.5 million gallon per day (MGD) West County Wastewater Treatment Plant (WCWTP), the Louisville and Jefferson County Metropolitan Sewer District (MSD) initiated a program to cost effectively control odors at this plant. The program included air dispersion modeling to predict the impacts of potential odor control improvements, and an extensive community participation program to involve the affected residents in the problem identification, model evaluation, and selection of the control approach. Using air dispersion models calibrated by field observations, MSD identified a 2- phased approach to resolving odor issues. Field verification after completion of the first phase of improvements validated the model predictions, confirming that off-site odors were virtually eliminated with the Phase 1 improvements. This phased approach was successful in resolving community concerns regarding off-site odors and saved MSD nearly 4 million in the process, by eliminating the need for the second phase of improvements. This project is unique in its use of air dispersion modeling to select the odor control system and to verify the results afterwards with performance testing and community odor surveys. Goals and Objectives The goals established for the project were based on MSD's Facilities Buffer Zone Policy, which requires MSD to evaluate reasonable technical approaches to minimize detrimental off-site impacts of their facilities. The specific objectives of this project were to identify all the odor sources and to select the minimum-cost odor control systems that could reliably eliminate offensive off-site odors. To help ensure community acceptance, the project also included extensive public participation in the process, particularly in the area of identifying the problem through community odor surveys and plant tours. Identifying the Problem A comprehensive sampling and testing program was conducted to determine odor emission rates for the plant. In addition, community odor surveys (with residents' participation) were conducted to record odor character, to measure intensity and to identify the source of the odor. Odor testing revealed that the influent screen building (80%) and the activated sludge process (10%) were the highest sources of odor emissions from the plant site. The original intent, therefore, was to cover all the aeration tanks and treat all the air from the plant processes, at a cost of about 6 million. It was then decided to perform atmospheric dispersion odor modeling to predict the downwind odor concentrations measured in dilutions-to-threshold (D/T) from controlled and uncontrolled odor sources. The investigation of the alternative odor control strategies also included an examination of the frequency of any odor concentration greater than the established odor detection threshold DT of 7. Contour plots were prepared to view the number of times during the year the odors are above the 7 DT for short time periods. The Solution A modified 2-phased plan was prepared for odor control, which included covering the aerated influent channels to the activated sludge process and treating this air in a modular synthetic media biofilter and converting the aeration basins to fine bubble diffusers (which was already in the budget for energy saving reasons). The influent channels were found to be the most likely source of activated sludge odors detected off-site due to the mixing of raw sewage and return activated sludge. Other improvements included the installation of a 14,000 cfm carbon adsorber for the influent screen room, covers on the grit tanks and use of activated sludge diffusion to treat the collected air. The modeling results showed that with this modified plan the closest neighbors might occasionally notice a faint odor (between 7 and 24 DT), as compared to previous conditions when the model predicted as many as 500 occurrences per year with DT's as high as 80. On this basis, MSD decided to pursue this phased approach and test the odor control systems and conduct additional community surveys after the first phase was completed to see if the odor control systems then in-place were sufficient or if further odor control was required. The Benefits All the odor control systems were tested after start-up and the results showed an 87% reduction in overall odor emissions from the plant and a 97% reduction in hydrogen sulfide emissions. Treatment plant odors were never detected in the community surveys conducted following the odor control system startup and residents commented that they no longer detected the odor from the plant. The paper presents the odor levels tested prior to odor control, the odor levels assumed for the modeling and the odor levels actually tested in the performance testing of the equipment. The project clearly demonstrates the value of odor testing and modeling and the importance of follow up testing and monitoring to verify that the investment resulted in effective odor control. In this case, MSD saved 4 million and developed community acceptance with this approach.
Project Overview In response to odor complaints received from residents near the 19.5 million gallon per day (MGD) West County Wastewater Treatment Plant (WCWTP), the Louisville and Jefferson County Metropolitan Sewer District (MSD) initiated a program to cost effectively control odors at this plant. The program included air dispersion modeling to predict the impacts of potential odor control...
Author(s)
N. WebsterS. WorleyG. SwansonA. HoggeW. Desing
SourceProceedings of the Water Environment Federation
SubjectSession 34: Biotechnology for Controlling Odor and VOCs
Document typeConference Paper
PublisherWater Environment Federation
Print publication date Jan, 2004
ISSN1938-6478
SICI1938-6478(20040101)2004:13L.231;1-
DOI10.2175/193864704784138043
Volume / Issue2004 / 13
Content sourceWEFTEC
First / last page(s)231 - 241
Copyright2004
Word count807

Actions, changes & tasks

Outstanding Actions

Add action for paragraph

Current Changes

Add signficant change

Current Tasks

Add risk task

Connect with us

Follow us on Facebook
Follow us on Twitter
Connect to us on LinkedIn
Subscribe on YouTube
Powered by Librios Ltd
Powered by Librios Ltd
Authors
Terms of Use
Policies
Help
Accessibility
Contact us
Copyright © 2024 by the Water Environment Federation
Loading items
There are no items to display at the moment.
Something went wrong trying to load these items.
Description: WWTF Digital Boot 180x150
WWTF Digital (180x150)
Created on Jul 02
Websitehttps:/­/­www.wef.org/­wwtf?utm_medium=WWTF&utm_source=AccessWater&utm_campaign=WWTF
180x150
N. Webster# S. Worley# G. Swanson# A. Hogge# W. Desing. ODOR MODELING: CASE STUDY SHOWS COST SAVINGS AND FIELD VERIFIED RESULTS. Alexandria, VA 22314-1994, USA: Water Environment Federation, 2018. Web. 9 Oct. 2025. <https://www.accesswater.org?id=-290853CITANCHOR>.
N. Webster# S. Worley# G. Swanson# A. Hogge# W. Desing. ODOR MODELING: CASE STUDY SHOWS COST SAVINGS AND FIELD VERIFIED RESULTS. Alexandria, VA 22314-1994, USA: Water Environment Federation, 2018. Accessed October 9, 2025. https://www.accesswater.org/?id=-290853CITANCHOR.
N. Webster# S. Worley# G. Swanson# A. Hogge# W. Desing
ODOR MODELING: CASE STUDY SHOWS COST SAVINGS AND FIELD VERIFIED RESULTS
Access Water
Water Environment Federation
December 22, 2018
October 9, 2025
https://www.accesswater.org/?id=-290853CITANCHOR