lastID = -292353
Skip to main content Skip to top navigation Skip to site search
Top of page
  • My citations options
    Web Back (from Web)
    Chicago Back (from Chicago)
    MLA Back (from MLA)
Close action menu

You need to login to use this feature.

Please wait a moment…
Please wait while we update your results...
Please wait a moment...
Description: Access Water
Context Menu
Description: Book cover
DEVELOPMENT OF SITE-SPECIFIC DISSOLVED OXYGEN STANDARDS IN SURFACE WATERS AT DENVER INTERNATIONAL AIRPORT
  • Browse
  • Compilations
    • Compilations list
  • Subscriptions
Tools

Related contents

Loading related content

Workflow

No linked records yet

X
  • Current: 2022-05-06 16:36:24 Adam Phillips
  • 2022-05-06 16:36:23 Adam Phillips
  • 2020-03-27 01:38:10 Adam Phillips
  • 2020-03-27 01:38:04 Adam Phillips
  • 2020-01-31 22:02:49 Administrator
  • 2020-01-31 22:02:48 Administrator
Description: Access Water
  • Browse
  • Compilations
  • Subscriptions
Log in
0
Accessibility Options

Base text size -

This is a sample piece of body text
Larger
Smaller
  • Shopping basket (0)
  • Accessibility options
  • Return to previous
Description: Book cover
DEVELOPMENT OF SITE-SPECIFIC DISSOLVED OXYGEN STANDARDS IN SURFACE WATERS AT DENVER INTERNATIONAL AIRPORT

DEVELOPMENT OF SITE-SPECIFIC DISSOLVED OXYGEN STANDARDS IN SURFACE WATERS AT DENVER INTERNATIONAL AIRPORT

DEVELOPMENT OF SITE-SPECIFIC DISSOLVED OXYGEN STANDARDS IN SURFACE WATERS AT DENVER INTERNATIONAL AIRPORT

  • New
  • View
  • Details
  • Reader
  • Default
  • Share
  • Email
  • Facebook
  • Twitter
  • LinkedIn
  • New
  • View
  • Default view
  • Reader view
  • Data view
  • Details

This page cannot be printed from here

Please use the dedicated print option from the 'view' drop down menu located in the blue ribbon in the top, right section of the publication.

screenshot of print menu option

Description: Book cover
DEVELOPMENT OF SITE-SPECIFIC DISSOLVED OXYGEN STANDARDS IN SURFACE WATERS AT DENVER INTERNATIONAL AIRPORT
Abstract
Denver International Airport (DIA) seasonally utilizes chemicals for aircraft deicing to enhance air travel safety. According to the State of Colorado, DIA has a state of the art aircraft deicing fluid (ADF) collection system and has implemented all best practical, available and economically achievable technology for the control of ADF. However, even with these systems in place, the open air application of deicing chemicals to aircraft creates a potential for migration of fugitive ADF to the storm sewer and thus to the local receiving waters.Concerns regarding the impact of ADF on airport receiving waters resulted in the implementation of a Receiving Water Study to assess potential impacts on surface waters, including potential effects on dissolved oxygen levels. Working with state and federal regulators, DIA conducted studies for more than three years to characterize ambient dissolved oxygen conditions and assess the aquatic communities in airport receiving waters. Five streams, which receive stormwater runoff from the airport property, were studied. A range of hydrological, biological and potential impact conditions were represented: (1) Second Creek, a highly intermittent stream; (2) Third Creek, an intermittent stream with enhanced flows resulting from airport stormwater discharge; (3) Box Elder Creek, a hydrologically variable stream, which received little or no impact from ADF; and (4) two ephemeral streams that only rarely receive stormwater runoff. A site on Second Creek upstream of airport development served as the study reference site because it represented natural conditions without airport impact.The Receiving Water Study demonstrated that DIA's receiving waters, regardless of the presence of ADF, routinely experience dissolved oxygen concentrations below the 5.0 mg/L standard adopted by Colorado to protect warmwater aquatic life. Moreover, the results of the biological assessment indicated the presence of a healthy aquatic community, that was most limited by habitat constraints rather than impacts from airport operations. Based on these findings, it was recommended that DIA develop site-specific dissolved oxygen standards for the airport's receiving waters.The State of Colorado water quality standards regulations authorize various approaches for establishing water quality criteria, including both toxicological and ambient-based methods. To facilitate the development of site-specific dissolved oxygen standards, DIA established a broadbased stakeholder group to provide both technical and policy guidance throughout the process. Using Colorado regulations as a guide, several approaches for developing standards were evaluated with stakeholders. Ultimately, it was recommended that DIA use an ambient-based approach to establish site-specific standards because the data indicated that the aquatic life use was attained at existing dissolved oxygen concentrations.Following the recommendations of the stakeholder group, ambient-based dissolved oxygen criteria were established for Second, Third and Box Elder Creeks by calculating the 15th percentile of continuous dissolved oxygen measurements from the daytime hours between 6:30 am and 6:30 pm. Accordingly, the following standards were recommended: Second Creek (3.3 mg/L), Third Creek (4.0 mg/L), and Box Elder Creek (4.7 mg/L). For the two ephemeral waterbodies insufficient data existed to calculate a numeric ambient-based dissolved oxygen standards. As a consequence, a narrative dissolved oxygen standard was developed for these waters.DIA submitted the proposed site-specific numeric and narrative dissolved oxygen standards to the Colorado Water Quality Control Commission (WQCC) for consideration in the South Platte River Basin triennial review of water quality standards. On July 13, 2004, the WQCC unanimously moved to adopt the DIA proposal. The standards were approved by EPA and became effective on January 20, 2005.
Denver International Airport (DIA) seasonally utilizes chemicals for aircraft deicing to enhance air travel safety. According to the State of Colorado, DIA has a state of the art aircraft deicing fluid (ADF) collection system and has implemented all best practical, available and economically achievable technology for the control of ADF. However, even with these systems in place, the open air...
Author(s)
Richard MeyerhoffJanell Barrilleaux
SourceProceedings of the Water Environment Federation
SubjectSession 10: Water Quality Criteria and Designated Uses I
Document typeConference Paper
PublisherWater Environment Federation
Print publication date Jan, 2005
ISSN1938-6478
SICI1938-6478(20050101)2005:3L.1002;1-
DOI10.2175/193864705783967566
Volume / Issue2005 / 3
Content sourceTMDLS Conference
First / last page(s)1002 - 1026
Copyright2005
Word count570

Purchase price $11.50

Get access
Log in Purchase content Purchase subscription
You may already have access to this content if you have previously purchased this content or have a subscription.
Need to create an account?

You can purchase access to this content but you might want to consider a subscription for a wide variety of items at a substantial discount!

Purchase access to 'DEVELOPMENT OF SITE-SPECIFIC DISSOLVED OXYGEN STANDARDS IN SURFACE WATERS AT DENVER INTERNATIONAL AIRPORT'

Add to cart
Purchase a subscription to gain access to 18,000+ Proceeding Papers, 25+ Fact Sheets, 20+ Technical Reports, 50+ magazine articles and select Technical Publications' chapters.
Loading items
There are no items to display at the moment.
Something went wrong trying to load these items.
Description: Book cover
DEVELOPMENT OF SITE-SPECIFIC DISSOLVED OXYGEN STANDARDS IN SURFACE WATERS AT DENVER INTERNATIONAL AIRPORT
Pricing
Non-member price: $11.50
Member price:
-292353
Get access
-292353
Log in Purchase content Purchase subscription
You may already have access to this content if you have previously purchased this content or have a subscription.
Need to create an account?

You can purchase access to this content but you might want to consider a subscription for a wide variety of items at a substantial discount!

Purchase access to 'DEVELOPMENT OF SITE-SPECIFIC DISSOLVED OXYGEN STANDARDS IN SURFACE WATERS AT DENVER INTERNATIONAL AIRPORT'

Add to cart
Purchase a subscription to gain access to 18,000+ Proceeding Papers, 25+ Fact Sheets, 20+ Technical Reports, 50+ magazine articles and select Technical Publications' chapters.

Details

Description: Book cover
DEVELOPMENT OF SITE-SPECIFIC DISSOLVED OXYGEN STANDARDS IN SURFACE WATERS AT DENVER INTERNATIONAL AIRPORT
Abstract
Denver International Airport (DIA) seasonally utilizes chemicals for aircraft deicing to enhance air travel safety. According to the State of Colorado, DIA has a state of the art aircraft deicing fluid (ADF) collection system and has implemented all best practical, available and economically achievable technology for the control of ADF. However, even with these systems in place, the open air application of deicing chemicals to aircraft creates a potential for migration of fugitive ADF to the storm sewer and thus to the local receiving waters.Concerns regarding the impact of ADF on airport receiving waters resulted in the implementation of a Receiving Water Study to assess potential impacts on surface waters, including potential effects on dissolved oxygen levels. Working with state and federal regulators, DIA conducted studies for more than three years to characterize ambient dissolved oxygen conditions and assess the aquatic communities in airport receiving waters. Five streams, which receive stormwater runoff from the airport property, were studied. A range of hydrological, biological and potential impact conditions were represented: (1) Second Creek, a highly intermittent stream; (2) Third Creek, an intermittent stream with enhanced flows resulting from airport stormwater discharge; (3) Box Elder Creek, a hydrologically variable stream, which received little or no impact from ADF; and (4) two ephemeral streams that only rarely receive stormwater runoff. A site on Second Creek upstream of airport development served as the study reference site because it represented natural conditions without airport impact.The Receiving Water Study demonstrated that DIA's receiving waters, regardless of the presence of ADF, routinely experience dissolved oxygen concentrations below the 5.0 mg/L standard adopted by Colorado to protect warmwater aquatic life. Moreover, the results of the biological assessment indicated the presence of a healthy aquatic community, that was most limited by habitat constraints rather than impacts from airport operations. Based on these findings, it was recommended that DIA develop site-specific dissolved oxygen standards for the airport's receiving waters.The State of Colorado water quality standards regulations authorize various approaches for establishing water quality criteria, including both toxicological and ambient-based methods. To facilitate the development of site-specific dissolved oxygen standards, DIA established a broadbased stakeholder group to provide both technical and policy guidance throughout the process. Using Colorado regulations as a guide, several approaches for developing standards were evaluated with stakeholders. Ultimately, it was recommended that DIA use an ambient-based approach to establish site-specific standards because the data indicated that the aquatic life use was attained at existing dissolved oxygen concentrations.Following the recommendations of the stakeholder group, ambient-based dissolved oxygen criteria were established for Second, Third and Box Elder Creeks by calculating the 15th percentile of continuous dissolved oxygen measurements from the daytime hours between 6:30 am and 6:30 pm. Accordingly, the following standards were recommended: Second Creek (3.3 mg/L), Third Creek (4.0 mg/L), and Box Elder Creek (4.7 mg/L). For the two ephemeral waterbodies insufficient data existed to calculate a numeric ambient-based dissolved oxygen standards. As a consequence, a narrative dissolved oxygen standard was developed for these waters.DIA submitted the proposed site-specific numeric and narrative dissolved oxygen standards to the Colorado Water Quality Control Commission (WQCC) for consideration in the South Platte River Basin triennial review of water quality standards. On July 13, 2004, the WQCC unanimously moved to adopt the DIA proposal. The standards were approved by EPA and became effective on January 20, 2005.
Denver International Airport (DIA) seasonally utilizes chemicals for aircraft deicing to enhance air travel safety. According to the State of Colorado, DIA has a state of the art aircraft deicing fluid (ADF) collection system and has implemented all best practical, available and economically achievable technology for the control of ADF. However, even with these systems in place, the open air...
Author(s)
Richard MeyerhoffJanell Barrilleaux
SourceProceedings of the Water Environment Federation
SubjectSession 10: Water Quality Criteria and Designated Uses I
Document typeConference Paper
PublisherWater Environment Federation
Print publication date Jan, 2005
ISSN1938-6478
SICI1938-6478(20050101)2005:3L.1002;1-
DOI10.2175/193864705783967566
Volume / Issue2005 / 3
Content sourceTMDLS Conference
First / last page(s)1002 - 1026
Copyright2005
Word count570

Actions, changes & tasks

Outstanding Actions

Add action for paragraph

Current Changes

Add signficant change

Current Tasks

Add risk task

Connect with us

Follow us on Facebook
Follow us on Twitter
Connect to us on LinkedIn
Subscribe on YouTube
Powered by Librios Ltd
Powered by Librios Ltd
Authors
Terms of Use
Policies
Help
Accessibility
Contact us
Copyright © 2024 by the Water Environment Federation
Loading items
There are no items to display at the moment.
Something went wrong trying to load these items.
Description: WWTF Digital Boot 180x150
WWTF Digital (180x150)
Created on Jul 02
Websitehttps:/­/­www.wef.org/­wwtf?utm_medium=WWTF&utm_source=AccessWater&utm_campaign=WWTF
180x150
Richard Meyerhoff# Janell Barrilleaux. DEVELOPMENT OF SITE-SPECIFIC DISSOLVED OXYGEN STANDARDS IN SURFACE WATERS AT DENVER INTERNATIONAL AIRPORT. Alexandria, VA 22314-1994, USA: Water Environment Federation, 2018. Web. 7 Jun. 2025. <https://www.accesswater.org?id=-292353CITANCHOR>.
Richard Meyerhoff# Janell Barrilleaux. DEVELOPMENT OF SITE-SPECIFIC DISSOLVED OXYGEN STANDARDS IN SURFACE WATERS AT DENVER INTERNATIONAL AIRPORT. Alexandria, VA 22314-1994, USA: Water Environment Federation, 2018. Accessed June 7, 2025. https://www.accesswater.org/?id=-292353CITANCHOR.
Richard Meyerhoff# Janell Barrilleaux
DEVELOPMENT OF SITE-SPECIFIC DISSOLVED OXYGEN STANDARDS IN SURFACE WATERS AT DENVER INTERNATIONAL AIRPORT
Access Water
Water Environment Federation
December 22, 2018
June 7, 2025
https://www.accesswater.org/?id=-292353CITANCHOR