lastID = -294747
Skip to main content Skip to top navigation Skip to site search
Top of page
  • My citations options
    Web Back (from Web)
    Chicago Back (from Chicago)
    MLA Back (from MLA)
Close action menu

You need to login to use this feature.

Please wait a moment…
Please wait while we update your results...
Please wait a moment...
Description: Access Water
Context Menu
Description: Book cover
Coupling CFD with the Bioassay a Cost-Effective Method for In-Vessel UV Reactor Certification and Design
  • Browse
  • Compilations
    • Compilations list
  • Subscriptions
Tools

Related contents

Loading related content

Workflow

No linked records yet

X
  • Current: 2020-01-31 21:31:58 Administrator
  • 2020-01-31 21:31:57 Administrator
Description: Access Water
  • Browse
  • Compilations
  • Subscriptions
Log in
0
Accessibility Options

Base text size -

This is a sample piece of body text
Larger
Smaller
  • Shopping basket (0)
  • Accessibility options
  • Return to previous
Description: Book cover
Coupling CFD with the Bioassay a Cost-Effective Method for In-Vessel UV Reactor Certification and Design

Coupling CFD with the Bioassay a Cost-Effective Method for In-Vessel UV Reactor Certification and Design

Coupling CFD with the Bioassay a Cost-Effective Method for In-Vessel UV Reactor Certification and Design

  • New
  • View
  • Details
  • Reader
  • Default
  • Share
  • Email
  • Facebook
  • Twitter
  • LinkedIn
  • New
  • View
  • Default view
  • Reader view
  • Data view
  • Details

This page cannot be printed from here

Please use the dedicated print option from the 'view' drop down menu located in the blue ribbon in the top, right section of the publication.

screenshot of print menu option

Description: Book cover
Coupling CFD with the Bioassay a Cost-Effective Method for In-Vessel UV Reactor Certification and Design
Abstract
For reclaimed water disinfection, each ultraviolet (UV) light reactor (lamp type, spacing, orientation) must undergo independent third-party performance certification under the UV Guidelines for Drinking Water and Water Reuse, published by the National Water Research Institute and the American Water Works Association Research Foundation (2003), hereafter called the 2003 UV Guidelines. Detailed reactor tests must be run to document the UV reactor performance over a range of hydraulic conditions (flow), water quality (UV transmittance [UVT]), and lamp intensity. The certification effort is costly, commonly ranging from $50,000 to greater than $120,000 for a single reactor. For open channel reactors with a common lamp and lamp spacing, it is possible to certify one small reactor and utilize the data set for the design and operation of much larger reactors, thus open channel systems require a reasonable certification effort that allows for wide ranging applications. This is not equally true for in-vessel UV reactors.Commercially available in-vessel UV reactors for wastewater applications are not standardized with one lamp type and lamp spacing. One UV manufacturer may, for example, have one reactor diameter, lamp type (intensity per length of lamp) and lamp density for one application and another completely different reactor (different diameter, lamp intensity, and lamp density) for another application based on varying flow and water quality conditions such as UVT. Thus test results for one reactor are obviously not valid for the second reactor. Aquionics Inc. (Aquionics), for further illustration, currently markets 7 entirely different UV reactors for various reclaimed water disinfection applications. Certification of all 7 reactors is cost prohibitive, with an estimated cost of greater than $700,000, which does not include the substantial costs of pilot construction.Carollo, working with Aquionics and the California Department of Health Services (CDHS) has found a solution to costly in-vessel UV reactor certification and design uncertainty, the coupling of detailed computational fluid dynamics (CFD) with the bioassay. As part of the project, detailed CFD models have been prepared for each of the 7 UV reactors, with flow capacities ranging from 5.0 mgd per reactor. To best calibrate the CFD results, 3 of the 7 reactors were rigorously bioassayed, with the bioassayed reactors spanning the lamp reactor diameter, lamp density, and lamp intensity range of the 7 reclaimed water reactors.This paper will detail the CFD modeling approach, the method of CFD model calibration with the bioassay, and the accuracy of the CFD when compared to the three bioassays. This paper will then conclude with an example of how to properly utilize the CFD/bioassay results for the proper design of an in-vessel reclaimed water UV system.
For reclaimed water disinfection, each ultraviolet (UV) light reactor (lamp type, spacing, orientation) must undergo independent third-party performance certification under the UV Guidelines for Drinking Water and Water Reuse, published by the National Water Research Institute and the American Water Works Association Research Foundation (2003), hereafter called the 2003 UV Guidelines. Detailed...
Author(s)
Tavy WadeAndrew SalvesonJon McCleanPatrick BollmanBree GradyLeon Janssen
SourceProceedings of the Water Environment Federation
SubjectSession 115: UV Efficiency, Effectiveness and Applications
Document typeConference Paper
PublisherWater Environment Federation
Print publication date Oct, 2007
ISSN1938-6478
SICI1938-6478(20071001)2007:8L.8983;1-
DOI10.2175/193864707787780954
Volume / Issue2007 / 8
Content sourceWEFTEC
First / last page(s)8983 - 8992
Copyright2007
Word count445
Subject keywordsULTRAVIOLET LIGHTUVCOMPUTATIONAL FLUID DYNAMICSCFDBIOASSAY

Purchase price $11.50

Get access
Log in Purchase content Purchase subscription
You may already have access to this content if you have previously purchased this content or have a subscription.
Need to create an account?

You can purchase access to this content but you might want to consider a subscription for a wide variety of items at a substantial discount!

Purchase access to 'Coupling CFD with the Bioassay a Cost-Effective Method for In-Vessel UV Reactor Certification and Design'

Add to cart
Purchase a subscription to gain access to 18,000+ Proceeding Papers, 25+ Fact Sheets, 20+ Technical Reports, 50+ magazine articles and select Technical Publications' chapters.
Loading items
There are no items to display at the moment.
Something went wrong trying to load these items.
Description: Book cover
Coupling CFD with the Bioassay a Cost-Effective Method for In-Vessel UV Reactor Certification and Design
Pricing
Non-member price: $11.50
Member price:
-294747
Get access
-294747
Log in Purchase content Purchase subscription
You may already have access to this content if you have previously purchased this content or have a subscription.
Need to create an account?

You can purchase access to this content but you might want to consider a subscription for a wide variety of items at a substantial discount!

Purchase access to 'Coupling CFD with the Bioassay a Cost-Effective Method for In-Vessel UV Reactor Certification and Design'

Add to cart
Purchase a subscription to gain access to 18,000+ Proceeding Papers, 25+ Fact Sheets, 20+ Technical Reports, 50+ magazine articles and select Technical Publications' chapters.

Details

Description: Book cover
Coupling CFD with the Bioassay a Cost-Effective Method for In-Vessel UV Reactor Certification and Design
Abstract
For reclaimed water disinfection, each ultraviolet (UV) light reactor (lamp type, spacing, orientation) must undergo independent third-party performance certification under the UV Guidelines for Drinking Water and Water Reuse, published by the National Water Research Institute and the American Water Works Association Research Foundation (2003), hereafter called the 2003 UV Guidelines. Detailed reactor tests must be run to document the UV reactor performance over a range of hydraulic conditions (flow), water quality (UV transmittance [UVT]), and lamp intensity. The certification effort is costly, commonly ranging from $50,000 to greater than $120,000 for a single reactor. For open channel reactors with a common lamp and lamp spacing, it is possible to certify one small reactor and utilize the data set for the design and operation of much larger reactors, thus open channel systems require a reasonable certification effort that allows for wide ranging applications. This is not equally true for in-vessel UV reactors.Commercially available in-vessel UV reactors for wastewater applications are not standardized with one lamp type and lamp spacing. One UV manufacturer may, for example, have one reactor diameter, lamp type (intensity per length of lamp) and lamp density for one application and another completely different reactor (different diameter, lamp intensity, and lamp density) for another application based on varying flow and water quality conditions such as UVT. Thus test results for one reactor are obviously not valid for the second reactor. Aquionics Inc. (Aquionics), for further illustration, currently markets 7 entirely different UV reactors for various reclaimed water disinfection applications. Certification of all 7 reactors is cost prohibitive, with an estimated cost of greater than $700,000, which does not include the substantial costs of pilot construction.Carollo, working with Aquionics and the California Department of Health Services (CDHS) has found a solution to costly in-vessel UV reactor certification and design uncertainty, the coupling of detailed computational fluid dynamics (CFD) with the bioassay. As part of the project, detailed CFD models have been prepared for each of the 7 UV reactors, with flow capacities ranging from 5.0 mgd per reactor. To best calibrate the CFD results, 3 of the 7 reactors were rigorously bioassayed, with the bioassayed reactors spanning the lamp reactor diameter, lamp density, and lamp intensity range of the 7 reclaimed water reactors.This paper will detail the CFD modeling approach, the method of CFD model calibration with the bioassay, and the accuracy of the CFD when compared to the three bioassays. This paper will then conclude with an example of how to properly utilize the CFD/bioassay results for the proper design of an in-vessel reclaimed water UV system.
For reclaimed water disinfection, each ultraviolet (UV) light reactor (lamp type, spacing, orientation) must undergo independent third-party performance certification under the UV Guidelines for Drinking Water and Water Reuse, published by the National Water Research Institute and the American Water Works Association Research Foundation (2003), hereafter called the 2003 UV Guidelines. Detailed...
Author(s)
Tavy WadeAndrew SalvesonJon McCleanPatrick BollmanBree GradyLeon Janssen
SourceProceedings of the Water Environment Federation
SubjectSession 115: UV Efficiency, Effectiveness and Applications
Document typeConference Paper
PublisherWater Environment Federation
Print publication date Oct, 2007
ISSN1938-6478
SICI1938-6478(20071001)2007:8L.8983;1-
DOI10.2175/193864707787780954
Volume / Issue2007 / 8
Content sourceWEFTEC
First / last page(s)8983 - 8992
Copyright2007
Word count445
Subject keywordsULTRAVIOLET LIGHTUVCOMPUTATIONAL FLUID DYNAMICSCFDBIOASSAY

Actions, changes & tasks

Outstanding Actions

Add action for paragraph

Current Changes

Add signficant change

Current Tasks

Add risk task

Connect with us

Follow us on Facebook
Follow us on Twitter
Connect to us on LinkedIn
Subscribe on YouTube
Powered by Librios Ltd
Powered by Librios Ltd
Authors
Terms of Use
Policies
Help
Accessibility
Contact us
Copyright © 2024 by the Water Environment Federation
Loading items
There are no items to display at the moment.
Something went wrong trying to load these items.
Description: WWTF Digital Boot 180x150
WWTF Digital (180x150)
Created on Jul 02
Websitehttps:/­/­www.wef.org/­wwtf?utm_medium=WWTF&utm_source=AccessWater&utm_campaign=WWTF
180x150
Tavy Wade# Andrew Salveson# Jon McClean# Patrick Bollman# Bree Grady# Leon Janssen. Coupling CFD with the Bioassay a Cost-Effective Method for In-Vessel UV Reactor Certification and Design. Water Environment Federation, 2018. Web. 30 Jun. 2025. <https://www.accesswater.org?id=-294747CITANCHOR>.
Tavy Wade# Andrew Salveson# Jon McClean# Patrick Bollman# Bree Grady# Leon Janssen. Coupling CFD with the Bioassay a Cost-Effective Method for In-Vessel UV Reactor Certification and Design. Water Environment Federation, 2018. Accessed June 30, 2025. https://www.accesswater.org/?id=-294747CITANCHOR.
Tavy Wade# Andrew Salveson# Jon McClean# Patrick Bollman# Bree Grady# Leon Janssen
Coupling CFD with the Bioassay a Cost-Effective Method for In-Vessel UV Reactor Certification and Design
Access Water
Water Environment Federation
December 22, 2018
June 30, 2025
https://www.accesswater.org/?id=-294747CITANCHOR